Hansgrohe 15840180 PURAVIDA RainBrain Instruction Manual
- October 30, 2023
- hansgrohe
Table of Contents
Hansgrohe 15840180 PURAVIDA RainBrain
Product Information
The product is referred to as RainBrain 15840180 and comes with installation instructions in several languages, including German, French, English, Italian, Spanish, Dutch, Polish, Chinese, Russian, Japanese, and Arabic. The product is an electronic device that requires installation and mounting on a wall. The technical specifications of the product include:
- Maximum operating pressure: 1 MPa
- Recommended operating pressure: 0.1 – 0.5 MPa
- Maximum flow rate at 0.3 MPa: 42.5 l/min
- Pressure rating: 1.6 MPa
- Free flow rate at 0.3 MPa: 42.5 l/min
Product Usage Instructions
Before using the product, it needs to be installed and mounted on a wall using the appropriate tools and following the installation sequence provided in the manual. The product should only be installed by qualified personnel or individuals authorized by the manufacturer.
The product can be used to control water flow and temperature in a shower system with up to five consumers, including a head shower, hand shower, and side shower. To use the product, follow these steps:
- Connect the water supply to the cold and hot water inlets of the product.
- Turn on the water supply and adjust the pressure to the recommended range of 0.1 – 0.5 MPa.
- Select the desired consumer(s) by pressing the corresponding button(s) on the device.
- Adjust the water temperature by turning the temperature knob to the desired level.
- Enjoy your shower!
Note that the product comes with a CD-ROM containing all the documentation and installation instructions. If you prefer printed instructions, contact the manufacturer for assistance.
symbols
- Warning – hazardous electrical voltage
- CAUTION! Must be adhered to!
- NOTE Indicates information, whose content is important and must be observed.
- Electrical fitter
- Installation tool/installation sequence
- Dimensions Installation dimensions
- Specifications
- Installation plans
Note: Read the operating instructions before you begin the installation. They contain information regarding the safe and proper installation.
Installation
- All work on the RainBrain may only be carried out in a de-energized state!
- All components must remain accessible.
- Wear safety clothes during the installation.
Risk of fire – installation box
- There must not be any flammable materials present in the immediate vicinity.
- The ambient temperature must not exceed 50 °C.
- The terminal block must be installed in protection area 2.
- When calculating the accumulator size and the drain, you must consider that up to 42.5 liters/min may be required for 0.3 MPa mixing water – depending on which showers will be combined.
Technical Dates
- Operating pressure: max. 1 MPa
- Recommended operating pressure: 0.1 – 0.5 MPa
- Test pressure: 1.6 MPa (1 MPa = 10 bar = 147 PSI)
- Hot water temperature: max. 80° C
- Recommended hot water temperature: 65° C
- Fitting dimensions: G ¾
- Fittings: cold on the right and warm on the left
- Free discharge at 0.3 MPa: 42.5 l/min
Note: The terminal block must be installed horizontally (Hansgrohe scribe must be legible). Supply lines from below.
Electrical fitter
All installation and inspection procedures must be carried out by an approved
electrician and in accordance with VDE 0100 Part 701 and IEC 60364-7-701.
Electrical connection
Mains supply 230V/N/PE/50Hz (3×1.5mm² length 0.5m). For electrical
installation, all applicable VDE, country-specifi c, and EVU regulations in
their respective valid versions must be observed. Potential equalization is
required at the site (4mm², cable length 1m).
Leakage current protection device
The fusing must be conducted via a leakage current protection device (RCD/FI)
with a measuringdiff essential power of 30 mA.
Installation zones electrical systems in accordance with VDE0100 part 701
- Arrangement and cable installation.
Fasteners
- Only use the proper fasteners! The included screws and dowels are only suitable for concrete.
For cleaning see, illustration 5
Drain capacity
The draining capacity must be at least 50 l/min.
Installation of the basic set display
-
Plaster in the basic set display, or install a wall covering if installed in front of the wall.
-
After the plastered wall surface has dried, spray the seam between the wall and the plastic casing with silicone (free of acetic acid!).
-
Coat the wall with PCI-Lastogum or a comparable sealing compound as instructed by the manufacturer.
-
Place the sealing collar over the plastic casing and press it into the glue and the silicone.
-
The sealing sleeve (F page 24) must not be heat-sealed
Repair
- Only by Hansgrohe qualified personnel or persons or companies designated by Hansgrohe.
Installation diagrams by Hansgrohe recommended
- A: Head shower 3-fold
- B: Head shower 2-fold
- C: Head shower 1-fold
Installation dimensions
- D = Basic installation
- E = Comfort installation with audio amplifier and light relay (part no. 27189000) All dimensions in mm.
Explanation of symbols
- Warning regarding hazardous electrical voltage
- Potential equalisation
- Audio amplifier (not available from Hansgrohe)
- Light relay box, part no. 27189000(available as an option)
- Illuminant (max. 500 Watt)
- Empty conduit EN20 /EN25
- Empty conduit speaker EN20
- Empty conduit lighting EN20
- Water connection / warm water
- Terminal box
- max = 10 bar / 1 MPa
- Water connection / cold water
- Head shower
- Hand shower
- Side shower
- No connection
- Silicone (free of acetic acid)
- Tefl on tape/hemp Fermit
INSTALLATION INSTRUCTIONS
Hansgrohe · Postfach 1145 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282 · Telefax +49 (0) 7836/511440 E-Mail: info@hansgrohe.com · Internet: www.hansgrohe.com.