Holtek Preliminary BC3603 PER-Demo Instruction Manual
- October 30, 2023
- HOLTEK
Table of Contents
Holtek Preliminary BC3603 PER-Demo Instruction Manual
Hardware Introduction
Terminal of master is made up of BCE-GENTRX32-002 and BCT-3603-X01
Terminal of slaver is made up of BCE-GENTRX32-002 and BCT-3603-X01
Software
This operation manual is used with the following demo codes:
Power On Procedure
- At first, please select power supply mode from “Power Source”.
- Connect the power supply interface.(For example by using USB interface)
- Slide the main power switch.
Power-on State
After the demo board is powered on:
- The Power LED will be steady work.
- The LCM will display some parameter values, such as TX values, RX values and ERROR values.
Tx: count value of RF successfully transmit
Ls: count value of RF failed transmit
Rx: count value of RF successfully receive
Er: count value of RF failed receive
Rsii: count value of RF RSSI detected when RF receive
Operation procedure
-
Press any button (key1~4) on the slaver board to start PER-Slaver function. After the function startup is successful, LCM will display “ON” and the system will being stand-by to wait signal from PER-Master.
-
Press any button (key1~4) on the master board to start PER-Master function. After the function startup is successful, LCM will display “ON” and the system will send data by sub-1GHz RF module. LCM will update and display parameter values (TX,LS,RX,ER,PER). LED will blink to indicate TX or RX successful.