PHENYX PRO PTM-10A UHF Stereo Wireless in Ear Monitor System Owner’s Manual

October 30, 2023
PHENYX PRO

PHENYX PRO LOGO PTM-1 OA
PTM-1 OB

Phenyx Pro PTM-10 Professional UHF Wireless
In Ear Monitoring System
-89 Selectable Frequency
-Ideal for Stage and Studio Use OWNER’S MANUAL

Thank you for purchasing the Phenyx Pro PTM-10 Wireless In Ear Monitoring System. For the best results and the utmost satisfaction for your new unit, please read this manual carefully to ensure proper operation, and keep it for future reference.For more information, please visit our store: www.phenyxpro.com.

System Description

Box Contents
– UHF wireless transmitter with balanced input x 1
– Antenna x 1
– 13 – 15V DC adapter, 500mA x 1
– Metal rackmount kit (extension cord and adapter) x 1
– Carrying case x 1
– User’s manual x 1
PTM-10A:
– Bodypack receiver x 1
– Earbud x 1
– 1.5V AA Battery x 2
PTM-10B:
– Bodypack receiver x 3
– Earbud x 3
– 1.5V AA Battery x 6
System overview
Phenyx Pro Professional UHF Wireless In-ear Monitor System is a practical solution to block out excess stage noise and provide consistent sound whe- never you go on stage, enabling uncluttered set designs, increasing freedom of movement, and enhancing sound performance.This system uses advan-ced circuit design to make the system’s receiving signal steady and improve the anti- interference function to show the perfect original sound again.
System features

  • UHF band frequencies
  • Mono mode or stereo mode, two selections
  • Integrated antenna for effective RF output and high transmission quality
  • Low battery indicator on the receiver
  • Lock feature to lock system in specific group/channel
  • Metal rackmount kit included to provide professional option
  • Black PVC carrying case to protect system while in transit
  • Clear, pure, distortion free sound performance

Transmitters
Front Panel
PHENYX PRO PTM-10A UHF Stereo Wireless in Ear Monitor System - fig
1

  1. 1/4-inch PHONE JACK (STEREO)
  2. EARPHONE VOLUME ADJUSTMENT KNOB Raise or lower the level of the audio signal to the earphones
  3. INPUT VOLUME ADJUSTMENT KNOB Control the monitor voiume level
  4. LCD DISPLAY Please see ‘Setup” section
  5. FREQUENCY SETUP BUTTION
  6. CHANNEL SELECTION BUTTION (‘UP’) Press to increase the wireless channel number
  7. CHANNEL SELECTION BUTTION (‘DOWN) Press to decrease the wireless charnel number
  8. POWER ON/OFF BUTTON
  9. IR window

Back Panel

PHENYX PRO PTM-10A UHF Stereo Wireless in Ear Monitor System - fig
2

  1. 13-1SV DC INPUT  Connect AC/DC adapter to receiver
  2. BALANCED/UNBALANCED AUDIO INPUT JACK (LEFT) Balantedilmbalance0 combo audio input jack for left channel
  3. BALANCED/UNBALANCEDAUDIO INPUT JACK (‘RIGHT) BalancedAinbalanced combo audio input jack for right channel
  4. PAD SWITCH Adjust output gain. To cut gain, set to (-I 2dB) The default setting of OdB will have no effect on gain
  5. ANTENNA JACK

Receiver
Good quality earphone for PTM-10 s stemPHENYX PRO PTM-10A UHF Stereo
Wireless in Ear Monitor System - fig 6 BodypackPHENYX PRO PTM-10A UHF Stereo Wireless in Ear
Monitor System - fig 7

  1. ON/OFF power switch
  2. Volume Control
  3. Earphone Jack
  4. Belt Clip
  5. IR Window
  6. LCD display
  7. SET Button — Confirm or select menu
  8. ADD Button — Select menu
  9. Antenna

Operation Instructions

Transmitter Setup And LCD Display PHENYX PRO PTM-10A UHF Stereo
Wireless in Ear Monitor System - fig 8

  1. GROUP SELECTION
    Press “SET” button until “Group” selection0flashes. Press Up or Down menu to select suitable frequency group number.

  2. CHANNEL SELECTION
    Press “SET” until “Channel” selection Oflashes. Press Up or Down menu to select suitable channel.

  3. MODE SELECTION
    Hold and press “SET” button until “Mode” selection 3flashes. Press Up menu to select Stereo7or Mono6operating mode. When the stereo function is enabled, the transmitted audio signal is ste-reophonic. When the mono function is enabled, the transmitted audio signal is in mono.

  4. LOCK FUNCTION
    Hold and press “SET” button until “Lock” flashes. Press Up menu to select Lock or Unlock. If the frequency is locked, you cannot change the frequency no matter what button you press.

  5. EXIT
    Hold and press “SET” button until “Exit” flashes, exit the setting operation.

  6. MONO MODE

  7. STEREO MODE

  8. CHANNEL DISPLAY

  9. GROUP DISPLAY

Receiver Setup And LCD Display

1. Ll Function: Limiter function. When long press SET, you can enter the funct-ion menu. Li means limiter function, which prevents the sound to be distorted when you turn up the volume to be very high. However, it changes the music dynamic and might affect the trueness of the sound.
2. Press ADD button and you can select ON/OFF for the Ll function.PHENYX
PRO PTM-10A UHF Stereo Wireless in Ear Monitor System - fig
91. FO Function: Stereo/mono selection. When long press SET, you can enter the function menu. FO means stereo/mono selection, while OFF means stereo mode and ON means mono mode for the receiver. ‘The stereo/mono mode need to match the mode selection on the transmitter (base unit).
2. Press ADD button and you can select ON/OFF for the FO function.PHENYX
PRO PTM-10A UHF Stereo Wireless in Ear Monitor System - fig
101. Frequency Display: Press SET button on transmitter (base unit) to enter GR-OUP and CHANNEL selection menu to select desired frequency, then press SET until “IR ” shown on the LCD screen. Aim the IR window of the receiver to the IR window of the transmitter, and the pair up will be finished within seco-nds. Frequency will display on the LCD screen of the receiver (bodypack) as well.
2. RF Indicator: Show the strength of signal.
3. AF Indicator: Show the strength of audio output.
4. Low Battery Indicator: Please install fresh batteries when the battery is low
PHENYX PRO PTM-10A UHF Stereo Wireless in Ear Monitor System - fig
11
Receiver Setup And LCD Display
1. BAL Function: Balance function. When the receiver is in frequency display status, short press SET button to enter balance function menu, which can adjust the volume of left/right channel.
2. Left/right channel volume display: Press SET button to increase left channel and press ADD button to increase right channel. 1. LO Function: Lock function. Lock the selected frequency on the receiver.
2. Press ADD button to select ON/OFF 1. Function: Equalizer function. Adjust the tone/pitch of the music sound.
2. Press ADD button to select ON/OFF. When it is in OFF mode, the receiver is in normal mode and would not adjust the tone/pitch of the music sound regardless of the strength of volume. When it is in ON mode, the receiver is in “increase tone/pitch” mode. Operation
A – Remove packing material
B – Set up the PTM-10 receiver

  1. 0pen the battery cover of the bodypack receiver and place two 1.5V M batteries into the battery housing with the batteries polarity orientations as indicated.
  2. Plug the supplied earphones into the earphone output jack on the body-pack receiver.
  3. Turn on the power of the bodypack receiver. The LCD display will display the current state of the receiver.

C – Set up the PTM-10 transmitter

  1. Place the transmitter at least 3.5ft (1 meter) away from the ground and all walls. Also, keep the transmitter as far away as possible fro any ele-ctromagnetic noise sources.
  2. Mount the antenna onto the antenna jack.
  3. Plug the AC/DC adapter to the transmitter’s DC input, and then plug the AC input of the adapter to a 120V AC outlet (North America).
  4. Turn on the transmitter and use SET button to enter menu and select desired frequency and operating mode.

D – Set up the PTM-10 In Ear Monitoring System

  1. Pair up the receiver to transmitter by aligning the IR window on the bod-ypack and the base unit.The frequency will synchronize within seconds.
  2. Refer to “Receiver Setup and LCD Display” section above to select de-sired operating mode and function.
  3. Enjoy reliable and beyond-expectation wireless sound monitoring perfo-rmance.

Troubleshooting Information

If you are receiving a system that is defective or you have any questions regarding operation or warranty cover, please contact us immediately for help and consultancy. You can reach us via email, official website, Facebook Messenger, or Amazon.
Email: [email protected]
Website: www.phenyxpro.com
Facebook Page: https://business.facebook.com/phenyxusa/
Specifications

  • Overall System
    Frequency range| 902-928MHz (Depends on local regulations)
    ---|---
    Transmitter Output Level| 10dBm
    Dynamic range| > 105dB
    Operation temperature| -10°C to +50 °C
    Frequency response| 60Hz – 16kHz
    Dynamic Range| >90dB A-weighted
    Stereo Separation| >40dB
    Working distance| 50M/164Ft
  • Transmitter
    Frequency range| +6dBV
    ---|---
    Gain Adjustment Range| 40dB
    Input Impedance| 6.8K0
    Dimensions| 44mm H 200mm W 96mm D
    Weight| 600g
    Power Requirement| DC 12 —18V, Current 300mA, External power adapter.
  • Bodypack Receiver
    Audio Input Level| 100mV
    ---|---
    Image Rejection| >65dB
    Dimensions| 90mm H 65mm W 24mm D
    Power requirement| 2 M size alkaline batteries
    Battery life| At least 8 hours with original batteries for each transmitter

Technical Support & Warranty Information

Our warranty to you: Phenyx Technology (“Phenyx”) warrants Phenyx products against eviden de-fects in material and workmanship for a period of one year from the date of original purchase for use.This warranty is valid exclusively in the US and applies only to the original owner. If you discover a defect covered by this warranty, Phenyx will repair or replace the product at our sole discretion using new or refurbished components. Performance of repairs or replacements under this Warranty is sub-ject to registration of your product at www.phenyxusa.com/registerproduct.
Product failures not covered by this warranty: This warranty covers defects in manufacturing that arise from the correct use of the device. It is limited to defects in materials or workmanship and does not cover electrical or mechanical damage resulting from abuse, misuse, unauthorized modification, lack of reasonable care, extreme heat, cold, damage due to natural forces,or corrosive environments. This warranty does not cover the normal wear and tear on covers, housing, connectors, and accessories.
Limits of liability: If your Phenyx product fails or does not perform as warranted, your sole recourse shall be to replace or repair it as described above. Phenyx will not be liable to you or anyone else for any damages that result from the failure of this product. These damages include, but are not limited to, the following: lost profi ts, lost savings, lost data, damage to other equipment, and incidental or consequential damages arising from the use of or inability to use this product. IN NO EVENT PHENYX SHALL BE LIABLE FOR MORE THAN THE AMOUNT OF YOUR PURCHASE PRICE, NOT TO EXCEED THE CURRENT LIST PRICE OF THE PRODUCT.
How to obtain service under this warranty: If you are receiving a system that is defective or you have any questions regarding operation or warranty cover, please contact us at [email protected] with any questions or concerns and a Phenyx Pro representative will contact you to provide assistance. You can also reach out to us through Facebook page: www.facebook.com/phenyxusa/ or our official website: www.phenyxpro.com

|
---|---
https://m.me/144158102956828?ref=w9443660| http://www.phenyxpro.com

PHENYX PRO LOGOwww.phenyxpro.com
Designed in U.S Made in China

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PHENYX PRO User Manuals

Related Manuals