UB20 Ramfan TurboForce Ventilators
Owner’s Manual
UB20/ UB30
Euramco Safety, Inc.
2746 Via Orange Way
Spring Valley, CA 91978 USA
USA 1.800.4.RAMFAN
Tel +1.619.670.9590
Fax +1.619.670.7345
theteam@euramcosafety.com
www.EuramcoSafety.com
Preface
Thank you for purchasing the RAMFAN® UB20 or UB30 utility blower
manufactured by Euramco Safety, Inc. For more than 30 years Euramco
Safety has been on the cutting edge of industrial, fire, and marine
ventilation products. Each and every one of our blower/exhausters, smoke
ejectors, PPV & LSV fans and accessories represent the finest
technologies available. Every product is constructed to demanding and
exact specifications for quality, performance, and reliability. When human
life depends on having a fan that can deliver clean, safe air, you
have only one choice you can trust:
RAMFAN. Explore our website and online catalog at
www.EuramcoSafety.com and discover how
RAMFAN can make a difference in the field!
This manual covers operation and maintenance procedures for the
RAMFAN UB20 and UB30 utility blower/exhausters.
All product information in the publication is based on the most
current information available at the time of printing. Euramco Safety,
Inc. reserves the right to make changes at any time without notice.
READ MANUAL BEFORE STARTING FAN FOR FIRST TIME!
Specifications/ Warnings
MODEL | UB20 | UB30 |
---|---|---|
Part Number | ED7002 | ED8002 |
Airflow | 980 cfm | 1392 m³/h |
Power | 115V, 50/60Hz | 230V, 50/60Hz |
Power input max. (Start / Run) | 9.5A / 2.5A | 4.8A / 1.3A |
Motor output max. | 1/3 Hp | 0.25 kW |
Protection class | IP55 | IP55 |
Height x Width x Length | 14 x 12 x 13 in | 36 x 31 x 33 cm |
51 x 39 x 31 cm
Weight| 17 lbs| 8 kg| 37 lbs| 17lbs
Sound level @ 3’ / 1 m| 74 dB(A)| 74 dB(A)| 90 db(A)| 90 db(A)
- Specifications are subject to change without notice. Some values are approximate.
CAUTION!
Thermally Protected for Indoor/Outdoor Use
To protect the user, this unit is equipped with thermal overload protection and automatic reset. Motor will restart without warning after protector trips. If motor thermal protection trips, disconnect unit nd determine cause.
Do NOT change make or model of fan or motor.
Features & Benefits
RAMFAN® combines high performance turbofan design with high strength
polymers to create a line of rugged, portable turbo blowers. The
UB-Line is ideal for general use, confined space ventilation and
delivers the highest airflow in its class. The double-wall,
polyethylene casing is light-weight, corrosion and chemical resistant
and handles the bumps and falls of any job site.
The 8″/20 cm UB20 turbo blower is at the heart of the RAMFAN
industrial ventilation systems that provide you with the complete
solution for common confined space ventilation applications. The
multi-purpose blower and exhauster delivers powerful airflow in a
compact and lightweight package.
- Compact & Lightweight
- Integrated Duct Adapter
- Cord Strap
- 15’/4.6 m Extended Reach Power Cable
- Ultra Quiet
- Easily attaches Quick-Couple™ Duct Canister for Exhaust/Suction
The 12″/30 cm UB30 takes design cues from the UB20 in a larger form. The larger blower/exhauster produces a higher airflow for use in larger confined spaces. The larger the area you are trying to ventilate the more airflow you’ll need. The RAMFAN® UB30 has unmatched performance for a fan its size.It is built with a durable housing to withstand industrial workspace environments.
- 2 Integrated Duct Adapters
- Dual Voltage/ Dual Frequency
- Stackable design feature
- Cord Strap
- 15’/4.6 m Extended Reach Power Cable
Safety Precautions
Before Operation
Before starting for the first time: DO NOT START fan if there
are any signs of shipping damage, particularly to blade, guards, or
housing. If ANY damage is suspected, STOP and call your dealer
immediately.
Keep children away: Do not allow children to play with or around
the unit, which could result in injury. Be sure the unit is
inaccessible to children when not attended.
Keep unit grounded: Always operate the unit with a grounding plug
and a grounded electrical outlet. A grounding plug is an essential
safety feature that helps reduce the risk of shock or fire. Always
ensure the switch is in the OFF position prior to connecting to
power.
Protect power cord from damage: Use cords of suitable size for
amperage load. Never operate a unit with a damaged power cord, as
this may lead to electrical or fire hazards.
Extension Cords: Extension cords must be grounded and able to
deliver the appropriate voltage to the unit.
Do not use speed control device: To reduce the risk of fire or
electric shock, do not use fans with a solid-state speed control
device.
Handle with care: Do not drop or throw the unit. Rough treatment
can damage the components or wiring and create a hazardous condition.
Run on stable surface: Start only if blower is sitting in a stable
and upright position. While on level surface and running at full
speed, the blower should not move around. If unit is moving, check
rubber feet for damage and replace if necessary.
Secure during transport: When transporting in a vehicle, secure the
unit to prevent sliding and possible injury to vehicle occupants.
During Operation
Airflow Direction: When using the blower, note the directional
airflow indicator on the external housing.
Keep out of water: Never operate the unit in pooled or standing
water, as this may create a risk of injury from electrical shock.
Do not store outdoors. If electrical wiring or components become
wet, thoroughly dry them before using the unit.
Safety: Proper ear and eye protection must be worn while blower is
running. Keep fingers and hands clear of blade. Do not move blower
while it is running.
Keep air intakes clear: Do not clog or block air intakes, this may
occur if operated to close to loose lightweight objects such as
clothing or leaves. This can cause the unit to overheat and result
in a fire or electrical hazard.
Keep away dust and dirt: Do not allow dust, dirt, or other
particles to be drawn into the air intakes. Dirt in the motor can
cause it to overheat, resulting in a fire or electrical hazard. If
the motor gets dirty, clean it using an
air hose.
Allow repair only by qualified person: Immediately stop the unit
upon hearing excessive mechanical noise or vibration. Do not attempt
to disassemble or repair the unit if you are not qualified to do
so. You can perform regular maintenance
or troubleshooting, however complex problems need to be repaired by
an authorized service technician.
For information about authorized repair, call Euramco Safety Customer
Service at +1 (619) 670-9590.
Operation
- Read the Owner’s Manual completely before starting fan.
- Wear both eye and ear protection.
- Position the fan on a level surface.
- Plug in to a standard outlet with the correct voltage and amperage for the unit. Set the switch to ON. Check for proper operation before leaving the unit unattended. Do not move or carry the blower while it is running
Maintenance
LOCK-OUT / TAG-OUT : When performing any maintenance, always follow all
additional safety precautions that your company may have for lock-out / tag-
out procedures.
POWER OFF : Always turn the power OFF and unplug the unit before
performing maintenance procedures. All the service procedures below are to be
executed with the unit unplugged. Perform before each use or as needed.
DO NOT DISSASSEMBLE blower for maintenance reasons.
INSPECT ELECTRICAL SYSTEM: Inspect the electrical cord for damage at
regular intervals. Periodically, inspect internal wiring for bare wires,
insecure fasteners, and discoloration. Remove and repair any damaged wiring as
needed. Failure to do so may lead to electrical shock or a fire hazard.
CLEAN AIR INTAKES: Clean off any accumulated lint or other
materials from the finger guards. A build up will reduce the airflow
and may cause the motor to overheat and become a fire hazard.
NEVER operate fan with damaged or missing finger guards.
CLEAN EXTERIOR: Clean fan periodically to remove accumulated dust
or particles using a commercially available biodegradable cleaning
solution. DO NOT use solvents containing chlorinated hydrocarbons
(i.e. MEK, Acetone)
EXTERIOR INSPECTION: Evaluate exterior components and make sure
they are properly installed. Inspect the fan for loose fasteners at
least once every 6 months depending on frequency of use. Tighten
any loose fasteners immediately. DO NOT overtighten fasteners.
Listen to the unit for abnormal sounds. Check rubber feet for
excessive wear or breakage. Contact Euramco Safety for replacement
parts and installation instructions.
DO NOT WET MOTOR OR WIRING: To prevent damage to electrical
components, do not use a duct or pressure washer to clean a blower.
If electrical components do become wet, dry them immediately.
Troubleshooting
WARNING: Execute all the service procedures below with the
blower OFF and power cord unplugged.
“FS” or Field Solutions can be handled by the technician in the
field | “AST” or Authorized RAMFAN Service Technician
**PROBLEM**
| **CAUSE| See Above**|
**SOLUTION**
---|---|---|---
Motor won’t run| No power to machine
Switch not turned on
Blower impeller jammed
Intake or exhaust blocked
Thermal cut off has been tripped
Switch is broken
Loose wiring| FS
FS
FS
FS
FS
AST
AST| Plug in the unit;; check circuit breaker or fuse
Turn on the switch
Remove material jamming wheel
Turn machine off and allow to cool, then remove blockage
Allow blower to cool down and motor will restart automatically
Call distributor or Euramco for replacement switch
Check wiring and tighten as needed
Motor runs but impeller turns erratically or scrapes| Severe jolt has
caused motor mount to bend and impeller to rub
Severe jolt caused motor to slip out of mount and impeller to rub|
AST
AST
| Remove motor from housing, then replace or repair bent motor mount
Remove motor from housing, then re-install motor into mount
correctly
Unit vibrates excessively| Accumulation of soil on impeller
Blower impeller has lost balance
Blower impeller has been bent
Bent motor shaft| FS
AST
AST
AST
| Clean blower impeller
Balance or replace blower impeller
Replace blower impeller
Replace motor
Spare Parts
Contact factory for replacement parts and installation instructions.
Model UB20
Corresponding Bubble No.
| RAMFAN P/N|
Description
---|---|---
1| BL011| Impeller
2| ST010| Stator
4| ED4001| Intake Grill
8| EZP80783007| Retaining Clip
10| FZ-9540K46| Rubber Foot w/washer (4)
11| ED4003| Exhaust Grill
32a| ED0108| Junction Box complete with mounting parts and cable (115V)
32b| ED0208| Junction Box complete with mounting parts and cable (230V)
To order spare parts call Euramco Safety +1.619.670.9590 or email theteam@euramcosafety.com
Model UB30
Corresponding Bubble No.
| RAMFAN P/N|
Description
---|---|---
1| ST030| Stator
4| EJ4001| Housing
5| BL016| Impeller
10| EB4001| Intake/ Exhaust Grill
11| FZ-9540K58| Rubber Foot w/washer (4)
32a| ED0408| Junction Box complete with mounting parts and cable (115V)
32b| ED0508| Junction Box complete with mounting parts and cable (230V)
To order spare parts call Euramco Safety +1.619.670.9590 or email theteam@euramcosafety.com
UB20/UB30 Owner’s Manual
Euramco Safety, Inc. | SM-‐UB20 Rev A
Documents / Resources
|
Euramco Safety UB20 Ramfan TurboForce
Ventilators
[pdf] Owner's Manual
UB20, UB30, UB20 Ramfan TurboForce Ventilators, UB20, Ramfan TurboForce
Ventilators, TurboForce Ventilators, Ventilators
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>