Euramco Safety UB20 Ramfan TurboForce Ventilators Owner’s Manual

October 30, 2023
Euramco Safety

Euramco Safety logo UB20 Ramfan TurboForce Ventilators
Owner’s Manual
Euramco Safety UB20 Ramfan TurboForce Ventilators UB20/ UB30
Euramco   Safety,   Inc.
2746 Via Orange Way
Spring  Valley, CA 91978 USA
USA  1.800.4.RAMFAN
Tel   +1.619.670.9590
Fax   +1.619.670.7345
[email protected]  
www.EuramcoSafety.com

Preface

Thank  you  for  purchasing  the  RAMFAN®  UB20  or  UB30  utility  blower manufactured  by  Euramco  Safety,  Inc. For  more  than  30  years  Euramco Safety has been on the cutting  edge  of  industrial,  fire,  and  marine ventilation products. Each and  every  one  of  our  blower/exhausters,  smoke ejectors,  PPV  &  LSV  fans  and  accessories  represent   the  finest technologies  available. Every  product is constructed to demanding  and exact specifications  for quality, performance,  and reliability. When  human life  depends  on  having  a  fan  that  can  deliver  clean,  safe  air,  you have  only  one  choice  you  can  trust:
RAMFAN.   Explore  our  website  and  online  catalog  at www.EuramcoSafety.com  and  discover  how RAMFAN  can  make  a difference  in  the  field!
This  manual  covers  operation  and  maintenance  procedures  for  the RAMFAN  UB20  and  UB30  utility  blower/exhausters.
All  product  information  in  the  publication  is  based  on  the  most current  information  available  at  the  time  of printing.  Euramco  Safety, Inc.  reserves  the  right  to  make  changes  at  any  time  without  notice.
READ  MANUAL  BEFORE  STARTING  FAN  FOR  FIRST  TIME!

Specifications/ Warnings

MODEL UB20 UB30
Part Number ED7002 ED8002
Airflow 980 cfm 1392 m³/h
Power 115V, 50/60Hz 230V, 50/60Hz
Power input max. (Start / Run) 9.5A / 2.5A 4.8A / 1.3A
Motor output max. 1/3 Hp 0.25 kW
Protection class IP55 IP55
Height x Width x Length 14 x 12 x 13 in 36 x 31 x 33 cm

51 x 39 x 31 cm
Weight| 17 lbs| 8 kg| 37 lbs| 17lbs
Sound level @ 3’ / 1 m| 74 dB(A)| 74 dB(A)| 90 db(A)| 90 db(A)

  •  Specifications  are  subject  to  change  without  notice.  Some  values  are  approximate.
    CAUTION!
    Thermally  Protected  for  Indoor/Outdoor  Use
    To  protect  the  user,  this  unit  is  equipped  with  thermal  overload protection  and  automatic  reset.  Motor  will  restart  without  warning after  protector  trips.  If  motor  thermal  protection trips, disconnect unit  nd determine cause.
    Do  NOT  change  make  or  model  of  fan  or  motor.

Features  &  Benefits

RAMFAN®  combines  high  performance  turbofan  design  with  high  strength polymers  to  create  a  line  of  rugged,  portable  turbo  blowers.  The UB-­Line  is  ideal  for  general  use,  confined  space  ventilation  and delivers  the  highest  airflow  in  its  class.  The  double-­wall, polyethylene  casing  is  light-­weight,  corrosion  and  chemical  resistant and handles  the  bumps  and  falls  of  any  job  site.
The  8″/20  cm  UB20  turbo  blower  is  at  the  heart  of  the  RAMFAN industrial  ventilation  systems  that  provide  you  with the  complete solution  for  common  confined  space  ventilation  applications.  The multi-­purpose  blower  and  exhauster delivers  powerful  airflow  in  a compact  and  lightweight  package.

  • Compact  &  Lightweight
  • Integrated  Duct  Adapter
  • Cord  Strap
  • 15’/4.6  m  Extended  Reach  Power  Cable
  • Ultra  Quiet
  • Easily  attaches  Quick-­Couple™  Duct  Canister  for  Exhaust/Suction

The  12″/30  cm  UB30  takes  design cues  from  the  UB20  in  a  larger form.  The  larger  blower/exhauster  produces  a higher  airflow  for  use in  larger  confined  spaces.  The  larger  the  area  you  are  trying  to ventilate  the  more  airflow  you’ll need.  The  RAMFAN®  UB30  has unmatched performance for  a  fan its  size.It  is built with  a durable housing  to withstand  industrial  workspace  environments.

  • 2  Integrated  Duct  Adapters
  • Dual  Voltage/  Dual  Frequency
  • Stackable  design  feature
  • Cord  Strap
  • 15’/4.6  m  Extended  Reach  Power  Cable

Safety  Precautions

Before  Operation
Before  starting  for  the  first  time:  DO  NOT  START  fan  if  there are  any  signs  of  shipping  damage,  particularly  to  blade,  guards,  or housing.  If  ANY  damage  is  suspected,  STOP  and  call  your  dealer immediately.
Keep  children  away:  Do  not  allow  children  to  play  with  or  around the  unit,  which  could  result  in  injury.  Be sure  the  unit  is inaccessible  to  children  when  not  attended.
Keep  unit  grounded:  Always  operate  the  unit  with  a  grounding  plug and  a  grounded  electrical  outlet.  A  grounding  plug  is  an  essential safety  feature  that  helps  reduce  the  risk  of  shock  or  fire.  Always ensure  the  switch  is  in  the  OFF  position  prior  to  connecting  to power.
Protect  power  cord  from  damage:  Use  cords  of  suitable  size  for amperage  load.  Never  operate  a  unit  with  a  damaged  power  cord,  as this  may  lead  to  electrical  or  fire  hazards.
Extension  Cords:  Extension  cords  must  be  grounded  and  able  to deliver  the  appropriate  voltage  to  the  unit.
Do  not  use  speed  control  device:  To  reduce  the  risk  of  fire  or electric  shock,  do  not  use  fans  with  a  solid-­state  speed  control device.
Handle  with  care:  Do  not  drop  or  throw  the  unit.  Rough  treatment can  damage  the  components  or  wiring  and create  a  hazardous  condition.
Run  on  stable  surface:  Start  only  if  blower  is  sitting  in  a  stable and  upright  position.  While  on  level  surface and  running  at  full speed,  the  blower  should  not  move  around.  If  unit  is  moving,  check rubber  feet  for  damage and  replace  if  necessary.
Secure  during  transport:  When  transporting  in  a  vehicle,  secure  the unit  to  prevent  sliding  and  possible injury  to  vehicle  occupants.
During  Operation
Airflow  Direction:  When  using  the  blower,  note  the  directional airflow  indicator  on  the  external  housing.
Keep  out  of  water:  Never  operate  the  unit  in  pooled  or  standing water,  as  this  may  create  a  risk  of  injury  from  electrical  shock. Do  not  store  outdoors.  If  electrical  wiring  or  components  become wet,  thoroughly  dry them  before  using  the unit.
Safety:  Proper  ear  and  eye  protection  must  be  worn  while  blower  is running.  Keep  fingers  and  hands  clear  of  blade.  Do  not  move  blower while  it  is  running.
Keep  air  intakes  clear:  Do  not  clog  or  block  air  intakes,  this  may occur  if  operated  to  close  to  loose  lightweight  objects  such  as clothing  or  leaves.  This  can  cause  the  unit  to  overheat  and  result in  a  fire  or  electrical  hazard.
Keep  away  dust  and  dirt:  Do  not  allow  dust,  dirt,  or  other particles  to  be  drawn  into  the  air  intakes.  Dirt  in  the  motor  can cause  it  to  overheat,  resulting  in  a  fire  or  electrical  hazard.  If the  motor  gets  dirty,  clean  it  using  an
air  hose.
Allow  repair  only  by  qualified  person:  Immediately  stop  the  unit upon  hearing  excessive  mechanical  noise  or  vibration.  Do  not  attempt to  disassemble  or  repair  the  unit  if  you  are  not  qualified  to  do so.  You  can  perform regular  maintenance
or  troubleshooting,  however  complex  problems  need  to  be  repaired  by an  authorized service  technician.
For  information  about  authorized  repair,  call  Euramco  Safety  Customer Service  at  +1  (619)  670-­9590.

Operation

  1. Read the Owner’s Manual completely before starting fan.
  2. Wear both eye and ear protection.
  3. Position the fan on a level surface.
  4. Plug in to a standard outlet with the correct voltage and amperage for the unit. Set the switch to ON. Check for proper operation before leaving the unit unattended. Do not move or carry the blower while it is running

Maintenance

LOCK-OUT / TAG-OUT : When performing any maintenance, always follow all additional safety precautions that your company may have for lock-out / tag- out procedures.
POWER OFF : Always turn the power OFF and unplug the unit before performing maintenance procedures. All the service procedures below are to be executed with the unit unplugged. Perform before each use or as needed.
DO NOT DISSASSEMBLE blower for maintenance reasons.
INSPECT ELECTRICAL SYSTEM: Inspect the electrical cord for damage at regular intervals. Periodically, inspect internal wiring for bare wires, insecure fasteners, and discoloration. Remove and repair any damaged wiring as needed. Failure to do so may lead to electrical shock or a fire hazard.
CLEAN  AIR  INTAKES:  Clean  off  any  accumulated  lint  or  other materials  from  the  finger  guards.  A  build  up  will reduce  the  airflow and  may  cause  the  motor  to  overheat  and  become  a  fire  hazard. NEVER  operate  fan  with damaged  or missing  finger  guards.
CLEAN  EXTERIOR:  Clean  fan  periodically  to  remove  accumulated  dust or  particles  using  a  commercially available  biodegradable  cleaning solution.  DO  NOT  use  solvents  containing  chlorinated  hydrocarbons (i.e. MEK,  Acetone)
EXTERIOR  INSPECTION:  Evaluate  exterior  components  and  make  sure they  are  properly  installed.  Inspect the  fan  for  loose  fasteners  at least  once  every  6  months  depending  on  frequency  of  use.  Tighten any  loose fasteners  immediately.  DO  NOT  overtighten  fasteners.
Listen  to  the  unit  for  abnormal  sounds.  Check  rubber  feet  for excessive  wear  or  breakage.  Contact  Euramco Safety  for  replacement parts  and  installation  instructions.
DO  NOT  WET  MOTOR  OR  WIRING: To  prevent  damage  to  electrical components,  do  not  use  a  duct  or pressure  washer  to  clean  a  blower. If  electrical  components  do  become  wet,  dry  them  immediately.

Troubleshooting

WARNING:  Execute  all  the  service  procedures  below  with  the blower  OFF  and  power  cord  unplugged.
“FS”  or  Field  Solutions  can  be  handled  by  the  technician  in  the field  |  “AST”  or  Authorized  RAMFAN  Service  Technician

**PROBLEM**

| **CAUSE| See Above**|

**SOLUTION**

---|---|---|---
Motor won’t run| No power to machine
Switch not turned on
Blower impeller jammed
Intake or exhaust blocked
Thermal cut off has been tripped
Switch is broken
Loose wiring| FS
FS
FS
FS
FS
AST
AST| Plug in the unit;; check circuit breaker or fuse
Turn on the switch
Remove material jamming wheel
Turn machine off and allow to cool, then remove blockage
Allow blower to cool down and motor will restart automatically
Call distributor or Euramco for replacement switch
Check wiring and tighten as needed
Motor runs but impeller turns erratically or scrapes| Severe jolt has caused motor mount to bend and impeller to rub
Severe jolt caused motor to slip out of mount and impeller to rub| AST

AST

| Remove motor from housing, then replace or repair bent motor mount
Remove motor from housing, then re-­install motor into mount correctly
Unit vibrates excessively| Accumulation of soil on impeller
Blower impeller has lost balance
Blower impeller has been bent
Bent motor shaft| FS
AST
AST

AST

| Clean blower impeller
Balance or replace blower impeller
Replace blower impeller
Replace motor

Spare Parts

Contact factory for replacement parts and installation instructions.
Euramco Safety UB20 Ramfan TurboForce Ventilators -
parts

Model UB20

Corresponding Bubble No.

| RAMFAN P/N|

Description

---|---|---
1| BL011| Impeller
2| ST010| Stator
4| ED4001| Intake Grill
8| EZP80783007| Retaining Clip
10| FZ-­9540K46| Rubber Foot w/washer (4)
11| ED4003| Exhaust Grill
32a| ED0108| Junction Box complete with mounting parts and cable (115V)
32b| ED0208| Junction Box complete with mounting parts and cable (230V)

To order spare parts call Euramco Safety +1.619.670.9590 or email [email protected] Euramco
Safety UB20 Ramfan TurboForce Ventilators - parts 1

Model UB30

Corresponding Bubble No.

| RAMFAN P/N|

Description

---|---|---
1| ST030| Stator
4| EJ4001| Housing
5| BL016| Impeller
10| EB4001| Intake/ Exhaust Grill
11| FZ-­9540K58| Rubber Foot w/washer (4)
32a| ED0408| Junction Box complete with mounting parts and cable (115V)
32b| ED0508| Junction Box complete with mounting parts and cable (230V)

To order spare parts call Euramco Safety +1.619.670.9590 or email [email protected]

Euramco Safety logoUB20/UB30 Owner’s Manual
Euramco Safety, Inc. | SM-­‐UB20 Rev A

Documents / Resources

| Euramco Safety UB20 Ramfan TurboForce Ventilators [pdf] Owner's Manual
UB20, UB30, UB20 Ramfan TurboForce Ventilators, UB20, Ramfan TurboForce Ventilators, TurboForce Ventilators, Ventilators
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Euramco Safety User Manuals