UBB 3020L Udd Series Motor Fan Evap Kits Instruction Manual
- June 1, 2024
- UBB
Table of Contents
UBB 3020L Udd Series Motor Fan Evap Kits
Installation
- Loosen the fixing screws of the evaporator cover and remove the evaporator cover.
- Loosen the fixing screws on the control panel, remove the control panel, and loosen the connection wire terminals of the fan motor.
- Loosen the fixing screws of the fan mounting plate.
- Remove the fan mounting plate kit (fan mounting plate+ fan motor/3020L + fan motor cover)
- Replace the new fan mounting plate kit (fan mounting plate + fan motor/M4Q045-CA27- VH/G01 + fan motor cover).
- Connect the fan terminals properly (if the terminals are incorrect, they can be replaced with spark-proof connections).
- Install the control panel and evaporator cover.