Rack Solutions HyperShelf Series High Density PC Mounting for Hyperscale Data Centers Instruction Manual

October 30, 2023
Rack Solutions

Rack Solutions HyperShelf Series High Density PC Mounting for Hyperscale

Data Centers

Rack-Solutions-HyperShelf-Series-High-Density-PC-Mounting-for-Hyperscale-
Data-Centers-PRODUCT

Kit Contents

  • (1) HyperShelf
  • (1) Cable Management Bar

Mounting Hardware:

(6) 8-32 x .500 Truss Head Screw

Installation Instructions

  1. Remove the Outer Rails : Remove the outer rails by sliding them back, and pulling the inner white clip. To ensure that the rails will smoothly slide out, do not apply excessive forceRack-Solutions-HyperShelf-Series-High-Density-PC-Mounting-for-Hyperscale-Data-Centers-FIG-1
  2. Attach the Outer Rails : Attach the outer rails to the rack by hooking the top of the Outer Rail Bracket into the top hole of the “U” space. Secure the rails by installing (1) Truss Head Screw per side into the Outer Rail Brackets. Install the rst set of rails loosely and the second set of rails tightly.Rack-Solutions-HyperShelf-Series-High-Density-PC-Mounting-for-Hyperscale-Data-Centers-FIG-2
  3. Secure the Rear Outer Rails : Secure the rear of the outer rails by installing the (1) Truss Head Screw into the left Outer Rail Bracket, and install the (2) Truss Head Screws through the Cable Management Bracket and into the right Outer Rail Bracket.Rack-Solutions-HyperShelf-Series-High-Density-PC-Mounting-for-Hyperscale-Data-Centers-FIG-3
  4. Install the HyperShelf: Slide the shelf into the Outer Rails. Pull the blue tab on the inner rail to slide all the way in. Screw in the Thumb Screws to secure in place. Tighten loose rails to ensure that the HyperShelf slides into both rails at the same time. Two people are recommended for installationRack-Solutions-HyperShelf-Series-High-Density-PC-Mounting-for-Hyperscale-Data-Centers-FIG-4
  5. Install the Cable Management Arm : Attach the Cable Management Arm to the HyperShelf by putting the Cotter Pins through the Cable Management Brackets attached to the shelf and to the Outer Rail. For detailed information on installing the Cable Management Arm, follow the instructions included in the Cable Management Arm box.Rack-Solutions-HyperShelf-Series-High-Density-PC-Mounting-for-Hyperscale-Data-Centers-FIG-5

Disclaimer : Load HyperShelf with devices and cabling only once shelf is properly installed in rack. Devices should only be loaded once shelf is fully installed.

Side Panel Removal Instructions

  1. Remove the Side Panels (Captive Screw): To remove the side panels, unscrew the captive flat head screw with a flat head screwdriver, then pull up on the side panel to disengage the rear hooksRack-Solutions-HyperShelf-Series-High-Density-PC-Mounting-for-Hyperscale-Data-Centers-FIG-6
  2. Remove the Side Panels (Thumb Screw): For side panels with thumb screws, unscrew the thumb screws with a screwdriver, then pull up on the side panel to disengage the rear hooks. Rack-Solutions-HyperShelf-Series-High-Density-PC-Mounting-for-Hyperscale-Data-Centers-FIG-7

Warranty Statement

Innovation First, Inc. warrants our products against defects in material and workmanship for a period of one (1) year from the date of purchase. Innovation First, Inc. liability shall be limited to repairing or replacing, at our option, any defective product

RackSolutions.com If we can’t mount it, no one can.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>