Hyfire TAU-MC-01 Taurus Multi Sensor Detector User Guide
- October 30, 2023
- Hyfire
Table of Contents
TAU-MC-01 Taurus Multi Sensor Detector
User Guide
TAU-MC-01 Taurus Multi Sensor Detector
THE BOX
Available also in black plastic: TAU- MC-01-BL
INSIDE THE BOX
- 1 Multi-Sensor Detectowith mounting base
- 2 CR123A batteries
- 1 Quick start guide
- 1 QR code
IMPORTANT TO CONSIDER
When mounting a wireless device a comprehensive radio survey should have been
carried out to establish the location that provides the best coverage and
optimum reach. Taking into consideration the building structure and materials,
the survey identifies the wireless infrastructure required and product
locations for optimum performance, identifying any factor that could prevent
radio integrity.
Avoid fixing or mounting the unit close to the following:
- Equipment that utilised large electrical currents
- Large metal objects or structures
- Fluorescent lighting fittings
- Metal ceiling structures
- IT cabling.
Keep 2 meters minimum spacing between other wireless equipment in the area to
avoid signal interference.
EN54 approved environmental temperature range is -10°C to +55°C
UNBOXING
- When unboxing the detector you will find the unit and its mounting base.
- This comes with pre-formed mounting holes to mount the detector base and a securing screw on the base to ensure there is no unwanted removal.
MOUNTING STEPS
Proceed as follows to complete the device installation.
|
---|---
• Remove the detector’s dust cover, intended to protect the unit during
shipping.
• Remove the detector from the base twisting anticlockwise| • Locate the
mounting holes and mark them using a pencil on the desired surface you are
drilling.
• Using a suitable-sized drill bit (6 mm) drill the marked screw points on
your chosen surface.
• Ensure you use the correct fixings for the type of surface you are mounting
to.
|
• A plastic pop out tag is removable from the base to enable you to label the
address of the detector, prior to fixing to the ceiling: pop out the device
label tag from the base and insert it into the side.
• Screw the base to the ceiling using all fixing holes and appropriate-sized
screws.| Remove the battery compartment cover on the base on the detector.
|
Ensure the programming switch in the base of the detector is in position ON.|
Remove the batteries’ insulating tab ensuring the batteries are kept in their
lodgments.
|
The detector’s LED will signal 4 times red.| • Move the switch in the base of
the detector to position 1.
• The detector’s LED will blink few seconds green and then signal
alternatively green / red 4 times.
|
• Ensure you replace the battery cover as this forms part of the detectors
anti tamper protection and refit the detector locating it into the base
twisting clockwise.| • Secure the screw on the base to ensure there is no
unwanted removal using a M3 allen key.
• Ensure you put the QR code you found in the box either on the system map or
on the dedicated pages at the end of translator or expander manual.
For more information, please refer to the complete product manual.
Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV8 1NP
T: +44 (0)1926 485282,
E: info@hyfirewireless.co.uk
W: www.hyfirewireless.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>