makita HR007G XGT Cordless Combination Hammer Instruction Manual
- October 30, 2023
- Makita
Table of Contents
- HR007G XGT Cordless Combination Hammer
- SPECIFICATIONS
- SAFETY WARNINGS
- FUNCTIONAL DESCRIPTION
- ASSEMBLY
- OPERATION
- WIRELESS ACTIVATION FUNCTION
- Troubleshooting for wireless activation function
- MAINTENANCE
- OPTIONAL ACCESSORIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HR007G XGT Cordless Combination Hammer
Instruction Manual
HR007G XGT Cordless Combination Hammer
|
---|---
|
|
|
SPECIFICATIONS
Model: | HRONG |
---|---|
Capacities | Concrete |
Core bit | 54 mm |
Diamond core bit (dry type) | 65 mm |
Steel | 13 mm |
Wood | 32 mm |
No load speed | 0 – 980 min-1 |
Blows per minute | 0 – 5,000 min-1 |
Rated voltage | D.C. 36 V – 40 V max |
Overall length | with BL4025 |
with BL4040 | 473 mm |
Net weight | 3.8 – 4.8 kg |
Optional accessory
Model: | DX15 |
---|---|
Suction performance | 290 l/min |
Operating stroke | Up to 190 mm |
Suitable drill bit | Up to 260 mm |
Net weight | 1.3 kg |
- Due to our continuing program of research and development, the specifications herein are subject to change without notice.
- Specifications may differ from country to country.
- The weight may differ depending on the attachment(s), including the battery cartridge. The lightest and heaviest combinations, according to EPTA-Procedure 01/2014, are shown in the table.
Applicable battery cartridge and charger
Battery cartridge| BL4020 / BL4025 / BL4040* / BL4050F
-
: Recommended battery
---|---
Charger| DC40RA / DC40RB / DC40RC- Some of the battery cartridges and chargers listed above may not be available depending on your region of residence.
WARNING: Only use the battery cartridges and chargers listed above. Use of
any other battery cartridges and chargers may cause injury and/or fire.
Recommended cord connected power source
Portable power pack | PDC01 / PDC1200 |
---|
- The cord connected power source(s) listed above may not be available depending on your region of residence.
- Before using the cord connected power source, read instruction and cautionary markings on them.
Intended use
The tool is intended for hammer drilling and drilling in brick, concrete and
stone as well as for chiseling work.
It is also suitable for drilling without impact in wood, metal, ceramic and
plastic.
Noise
The typical A-weighted noise level determined according to EN62841-2-6:
Model HR007G
Sound pressure level (LpA): 91 dB (A)
Sound power level (LWA): 102 dB (A)
Uncertainty (K): 3 dB(A)
Model HR007G with DX15
Sound pressure level (LpA): 93 dB(A)
Sound power level (LWA): 104 dB (A)
Uncertainty (K) : 3 dB(A)
NOTE: The declared noise emission value(s) has been measured in
accordance with a standard test method and may be used for comparing one tool
with another.
NOTE: The declared noise emission value(s) may also be used in a
preliminary assessment of exposure.
WARNING: Wear ear protection.
WARNING: The noise emission during actual use of the power tool can differ
from the declared value(s) depending on the ways in which the tool is used
especially what kind of workpiece is processed.
WARNING: Be sure to identify safety measures to protect the operator that
are based on an estimation of exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as the times when the tool is
switched off and when it is running idle in addition to the trigger time).
Vibration
The following table shows the vibration total value (tri-axial vector sum)
determined according to applicable standard.
Work mode| Vibration emission| Uncertainty (K)| Applicable
standard/Test condition
---|---|---|---
Hammer drilling into concrete (ah, HD)| 10.4 m/s2| 1.5 m/s2| EN62841-2-6
9.2 m/s2| 1.5 m/s2| Recommended practical operation
Hammer drilling into concrete with DX15 (ah,HD)| 8.1 m/s2| 1.5 m/s2|
EN62841-2-6
6.7 m/s2| 1.5 m/s2| Recommended practical operation
Chiseling (ah, CHeq)| 9.7 m/s2| 1.5 m/s2| EN62841-2-6
9.1 m/s2| 1.5 m/s2| Recommended practical operation*
-
The test condition of recommended practical operation meets EN 62841-2-6, except for the following points:
- Feed force is applied to the switch handle (main handle) for working accuracy and efficiency.
- The side grip/handle (auxiliary handle) is held to keep balance of the tool.
NOTE: The declared vibration total value(s) has been measured in
accordance with a standard test method and may be used for comparing one tool
with another.
NOTE: The declared vibration total value(s) may also be used in a
preliminary assessment of exposure.
WARNING: The vibration emission during actual use of the power tool can
differ from the declared value(s) depending on the ways in which the tool is
used especially what kind of workpiece is processed.
WARNING: Be sure to identify safety measures to protect the operator that
are based on an estimation of exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as the times when the tool is
switched off and when it is running idle in addition to the trigger time).
EC Declaration of Conformity
For European countries only
The EC declaration of conformity is included as Annex A to this instruction
manual.
SAFETY WARNINGS
General power tool safety warnings
WARNING: Read all safety warnings, instructions, illustrations and
specifications provided with this power tool. Failure to follow all
instructions listed below may result in electric shock, fire and/or serious
injury.
Save all warnings and instructions for future reference.
The term “power tool” in the warnings refers to your mains-operated (corded)
power tool or battery-operated (cordless) power tool.
CORDLESS ROTARY HAMMER SAFETY WARNINGS
Safety instructions for all operations
- Wear ear protectors. Exposure to noise can cause hearing loss.
- Use auxiliary handle(s), if supplied with the tool. Loss of control can cause personal injury.
- Hold the power tool by insulated gripping surfaces, when performing an operation where the cutting accessory may contact hidden wiring. Cutting accessory contacting a “live” wire may make exposed metal parts of the power tool “live” and could give the operator an electric shock.
Safety instructions when using long drill bits with rotary hammers
- Always start drilling at low speed and with the bit tip in contact with the workpiece. At higher speeds, the bit is likely to bend if allowed to rotate freely without contacting the workpiece, resulting in personal injury.
- Apply pressure only in direct line with the bit and do not apply excessive pressure. Bits can bend, causing breakage or loss of control, resulting in personal injury.
Additional safety warnings
- Wear a hard hat (safety helmet), safety glasses and/or face shield. Ordinary eye or sun glasses are NOT safety glasses. It is also highly recommended that you wear a dust mask and thickly padded gloves.
- Be sure the bit is secured in place before operation.
- Under normal operation, the tool is designed to produce vibration. The screws can come loose easily, causing a breakdown or accident. Check tightness of screws carefully before operation.
- In cold weather or when the tool has not been used for a long time, let the tool warm up for a while by operating it under no load. This will loosen up the lubrication. Without proper warm-up, hammering operation is difficult.
- Always be sure you have a firm footing. Be sure no one is below when using the tool in high locations.
- Hold the tool firmly with both hands. .
- Keep hands away from moving parts.
- Do not leave the tool running. Operate the tool only when hand-held.
- Do not point the tool at any one in the area when operating. The bit could fly out and injure someone seriously.
- Do not touch the bit, parts close to the bit, or workpiece immediately after operation; they may be extremely hot and could burn your skin.
- Some material contains chemicals which may be toxic. Take caution to prevent dust inhalation and skin contact. Follow material supplier safety data.
- Always be sure that the tool is switched off and the battery cartridge and the bit are removed before handing the tool to other person.
- Before operation, make sure that there is no buried object such as electric pipe, water pipe or gas pipe in the working area. Otherwise, the drill bit/chisel may touch them, resulting an electric shock, electrical leakage or gas leak.
- Do not operate the tool at no-load unnecessarily.
SAVE THESE INSTRUCTIONS.
WARNING: DO NOT let comfort or familiarity with product (gained from
repeated use) replace strict adherence to safety rules for the subject
product. MISUSE or failure to follow the safety rules stated in this
instruction manual may cause serious personal injury.
Important safety instructions for battery cartridge
-
Before using battery cartridge, read all instructions and cautionary markings on (1) battery charger, (2) battery, and (3) product using battery.
-
Do not disassemble or tamper with the battery cartridge. It may result in a fire, excessive heat, or explosion.
-
If operating time has become excessively shorter, stop operating immediately. It may result in a risk of overheating, possible burns and even an explosion.
-
If electrolyte gets into your eyes, rinse them out with clear water and seek medical attention right away. It may result in loss of your eyesight.
-
Do not short the battery cartridge:
(1) Do not touch the terminals with any conductive material.
(2) Avoid storing battery cartridge in a container with other metal objects such as nails, coins, etc.
(3) Do not expose battery cartridge to water or rain. A battery short can cause a large current flow, overheating, possible burns and even a breakdown. -
Do not store and use the tool and battery cartridge in locations where the temperature may reach or exceed 50 °C (122 °F).
-
Do not incinerate the battery cartridge even if it is severely damaged or is completely worn out. The battery cartridge can explode in a fire.
-
Do not nail, cut, crush, throw, drop the battery cartridge, or hit against a hard object to the battery cartridge. Such conduct may result in a fire, excessive heat, or explosion.
-
Do not use a damaged battery.
-
The contained lithium-ion batteries are subject to the Dangerous Goods Legislation requirements. For commercial transports e.g. by third parties, forwarding agents, special requirement on packaging and labeling must be observed. For preparation of the item being shipped, consulting an expert for hazardous material is required. Please also observe possibly more detailed national regulations. Tape or mask off open contacts and pack up the battery in such a manner that it cannot move around in the packaging.
-
When disposing the battery cartridge, remove it from the tool and dispose of it in a safe place. Follow your local regulations relating to disposal of battery.
-
Use the batteries only with the products specified by Makita. Installing the batteries to non-compliant products may result in a fire, excessive heat, explosion, or leak of electrolyte.
-
If the tool is not used for a long period of time,the battery must be removed from the tool.
-
During and after use, the battery cartridge may take on heat which can cause burns or low temperature burns. Pay attention to the handling of hot battery cartridges.
-
Do not touch the terminal of the tool immediately after use as it may get hot enough to cause burns.
-
Do not allow chips, dust, or soil stuck into the terminals, holes, and grooves of the battery cartridge. It may cause heating, catching fire, burst and malfunction of the tool or battery cartridge, resulting in burns or personal injury.
-
Unless the tool supports the use near high-voltage electrical power lines, do not use the battery cartridge near a high-voltage electrical power lines. It may result in a malfunction or breakdown of the tool or battery cartridge.
-
Keep the battery away from children.
SAVE THESE INSTRUCTIONS.
CAUTION: Only use genuine Makita batteries. Use of non-genuine Makita batteries, or batteries that have been altered, may result in the battery bursting causing fires, personal injury and damage. It will also void the Makita warranty for the Makita tool and charger.
Tips for maintaining maximum battery life
- Charge the battery cartridge before completely discharged. Always stop tool operation and charge the battery cartridge when you notice less tool power.
- Never recharge a fully charged battery cartridge. Overcharging shortens the battery service life.
- Charge the battery cartridge with room temperature at 10 °C – 40 °C (50 °F – 104 °F). Let a hot battery cartridge cool down before charging it.
- When not using the battery cartridge, remove it from the tool or the charger. 5. Charge the battery cartridge if you do not use it for a long period (more than six months).
Important safety instructions for wireless unit
- Do not disassemble or tamper with the wireless unit.
- Keep the wireless unit away from young children. If accidentally swallowed, seek medicalattention immediately.
- Use the wireless unit only with Makita tools.
- Do not expose the wireless unit to rain or wetconditions.
- Do not use the wireless unit in places where the temperature exceeds 50 °C (122 °F).
- Do not operate the wireless unit in places where medical instruments, such as heart pace makers are nearby.
- Do not operate the wireless unit in places where automated devices are nearby. If operated, automated devices may develop malfunction or error.
- Do not operate the wireless unit in places under high temperature or places where static electricity or electrical noise could be generated.
- The wireless unit can produce electromagnetic fields (EMF) but they are not harmful to the user.
- The wireless unit is an accurate instrument. Be careful not to drop or strike the wireless unit.
- Avoid touching the terminal of the wireless unit with bare hands or metallic materials.
- Always remove the battery on the product when installing the wireless unit into it.
- When opening the lid of the slot, avoid the place where dust and water may come into the slot. Always keep the inlet of the slot clean.
- Always insert the wireless unit in the correct direction.
- Do not press the wireless activation button on the wireless unit too hard and/or press the button with an object with a sharp edge.
- Always close the lid of the slot when operating.
- Do not remove the wireless unit from the slot while the power is being supplied to the tool. Doing so may cause a malfunction of the wireless unit.
- Do not remove the sticker on the wireless unit.
- Do not put any sticker on the wireless unit.
- Do not leave the wireless unit in a place where static electricity or electrical noise could be generated.
- Do not leave the wireless unit in a place subject to high heat, such as a car sitting in the sun.
- Do not leave the wireless unit in a dusty or powdery place or in a place corrosive gas could be generated.
- Sudden change of the temperature may bedew the wireless unit. Do not use the wireless unit until the dew is completely dried.
- When cleaning the wireless unit, gently wipe with a dry soft cloth. Do not use benzine, thinner, conductive grease or the like.
- When storing the wireless unit, keep it in the supplied case or a static-free container.
- Do not insert any devices other than Makita wireless unit into the slot on the tool.
- Do not use the tool with the lid of the slot damaged. Water, dust, and dirt come into the slot may cause malfunction.
- Do not pull and/or twist the lid of the slot more than necessary. Restore the lid if it comes off from the tool.
- Replace the lid of the slot if it is lost or damaged.
SAVE THESE INSTRUCTIONS.
FUNCTIONAL DESCRIPTION
CAUTION: Always be sure that the tool is switched off and the battery
cartridge is removed before adjusting or checking function on the tool.
Installing or removing battery cartridge
CAUTION: Always switch off the tool before installing or removing of the
battery cartridge.
CAUTION: Hold the tool and the battery cartridge firmly when installing
or removing battery cartridge. Failure to hold the tool and the battery
cartridge firmly may cause them to slip off your hands and result in damage to
the tool and battery cartridge and a personal injury.
► Fig.1: 1. Red indicator 2. Button 3. Battery cartridge
To remove the battery cartridge, slide it from the tool while sliding the
button on the front of the cartridge.
To install the battery cartridge, align the tongue on the battery cartridge
with the groove in the housing and slipit into place. Insert it all the way
until it locks in place with a little click. If you can see the red indicator
as shown in the figure, it is not locked completely.
CAUTION: Always install the battery cartridge fully until the red
indicator cannot be seen. If not, it may accidentally fall out of the tool,
causing injury to you or someone around you.
CAUTION: Do not install the battery cartridge forcibly. If the cartridge
does not slide in easily, it is not being inserted correctly.
Indicating the remaining battery capacity
Press the check button on the battery cartridge to indicate the remaining
battery capacity. The indicator lamps light up for a few seconds.
► Fig.2: 1. Indicator lamps 2. Check button
Indicator lamps | Remaining capacity |
---|---|
Lighted | Off |
75% to 100% | |
50% to 75% | |
25% to 50% | |
0% to 25% | |
Charge thebattery. | |
The battery may have malfunctioned. |
NOTE: Depending on the conditions of use and the ambient temperature, the
indication may differ slightly from the actual capacity.
NOTE: The first (far left) indicator lamp will blink when the battery
protection system works.
Tool / battery protection system
The tool is equipped with a tool/battery protection system. This system
automatically cuts off power to the motor to extend tool and battery life. The
tool will automatically stop during operation if the tool or battery is placed
under one of the following conditions:
Overload protection
When the battery is operated in a manner that causes it to draw an abnormally
high current, the tool automatically stops without any indication. In this
situation, turn the tool off and stop the application that caused the tool to
become overloaded. Then turn the tool on to restart.
Overheat protection
When the tool or battery is overheated, the tool stops automatically. In this
case, let the tool and battery cool before turning the tool on again.
NOTE: When the tool is overheated, the lamp blinks.
Overdischarge protection
When the battery capacity is not enough, the tool stops automatically. In this
case, remove the battery from the tool and charge the battery.
Protections against other causes
Protection system is also designed for other causes that could damage the tool
and allows the tool to stop automatically. Take all the following steps to
clear the causes, when the tool has been brought to a temporary halt or stop
in operation.
- Turn the tool off, and then turn it on again to restart.
- Charge the battery(ies) or replace it/them with recharged battery(ies).
- Let the tool and battery(ies) cool down.
If no improvement can be found by restoring protection system, then contact your local Makita Service Center.
Switch action
WARNING: Before installing the battery car-tridge into the tool, always
check to see that the switch trigger actuates properly and returns to the
“OFF” position when released.
► Fig.3: 1. Switch trigger
To start the tool, simply pull the switch trigger. Tool speed is increased by
increasing pressure on the switch trigger. Release the switch trigger to stop.
Lighting up the front lamp
► Fig.4: 1. Lamp
CAUTION: Do not look in the light or see the source of light directly.
Pull the switch trigger to light up the lamp. The lamp keeps on lighting while
the switch trigger is being pulled. The lamp goes out approximately 10 seconds
after releasing the switch trigger.
CAUTION: If the lamp goes off after blinking for a few seconds, the
active feedback sensing technology is not working properly. Ask your local
Makita Service Center for repair.
NOTE: Use a dry cloth to wipe the dirt off the lens of the lamp. Be
careful not to scratch the lens of lamp, or it may lower the illumination.
NOTE: The front lamp cannot be used while the dust collection system
(optional accessory) is installed in the tool.
Reversing switch action
► Fig.5: 1. Reversing switch lever
CAUTION: Always check the direction of rotation before operation.
CAUTION: Use the reversing switch only afterthe tool comes to a complete
stop. Changing the direction of rotation before the tool stops may damage the
tool.
CAUTION: When not operating the tool, always set the reversing switch
lever to the neutral position.
This tool has a reversing switch to change the direction of rotation. Depress
the reversing switch lever from the A side for clockwise rotation or from the
B side for counterclockwise rotation. When the reversing switch lever is in
the neutral position, the switch trigger cannot be pulled.
Selecting the action mode
NOTICE: Do not rotate the action mode changing knob when the tool is
running. The tool will be damaged.
NOTICE: To avoid rapid wear on the mode change mechanism, be sure that
the action mode changing knob is always positively located in one of the three
action mode positions.
Rotation with hammering
For drilling in concrete, masonry, etc., turn the action mode changing knob to
the symbol while pressing the release button on the knob. Use a
tungstencarbide tipped bit (optional accessory).
► Fig.6: 1. Rotation with hammering 2. Action mode changing knob 3. Release
button
Rotation only
For drilling in wood, metal or plastic materials, turn the action mode
changing knob to the symbol while pressing the release button on the knob. Use
a twist drill bit or wood drill bit.
► Fig.7: 1. Rotation only
Hammering only
For chipping, scaling or demolition operations, turn the action mode changing
knob to the symbol while pressing the release button on the knob. Use a bull
point, cold chisel, scaling chisel, etc.
► Fig.8: 1. Hammering only
Hook
Optional accessory
CAUTION: Always remove the battery when hanging the tool with the hook.
CAUTION: Never hook the tool at high location or on potentially unstable
surface.
The hook is convenient for temporarily hanging the tool. Before installing the
hook, remove the rubber cap from the screw holes in the mounting bracket.
Insert the plate washers under the bracket, and then tighten the hook with
screws in place.
► Fig.9: 1. Rubber cap 2. Mounting bracket 3. Plate washers 4. Hook 5. Screws
For use, lift up the arm of the hook until it snaps into the open position.
When not in use, be sure that the hook is folded back in the closed position.
► Fig.10: 1. Hook 2. Open position 3. Closed position
► Fig.11
Connecting lanyard (tether strap) to the hook
CAUTION: Do not use damaged hook and screws. Before use, always check for
damages, cracks or deformations, and make sure that the screws are tightened.
CAUTION: Make sure that the hook is securely installed with the screws.
CAUTION: Do not install or remove any accessory while hanging the tool.
The tool may fall if the screws are not tightened.
CAUTION: Always use a locking carabiner (multi-action and screw gate
type) and be sure to attach the lanyard (tether strap) to the double looped
portion of the hook. Improper attachment may cause tool drop from the hook and
result in personal injury.
The hook is also used for connecting the lanyard (tether strap). Be sure to
connect the lanyard (tether strap) to the double looped portion of the hook.
► Fig.12: 1. Double looped portion of the hook 2. Lanyard (tether strap) 3.
Locking carabiner (multi-action and screw gate type)
Safety warnings about connecting lanyard (tether strap) to the hook
Safety warnings specific for use at height
Read all safety warnings and instructions. Failure to followthe warnings and
instructions may result in serious injury.
- Always keep the tool tethered when working “at height”. Maximum lanyard length is 2 m. The maximum permissible fall height for lanyard (tether strap) must not exceed 2 m.
- Use only with lanyards appropriate for this tool type and rated for at least 8.0 kg.
- Do not anchor the tool lanyard to anything on your body or on movable components. Anchor the tool lanyard to a rigid structure that can withstand the forces of a dropped tool.
- Make sure the lanyard is properly secured at each end prior to use.
- Inspect the tool and lanyard before each use for damage and proper function (including fabric and stitching). Do not use if damaged or not functioning properly.
- Do not wrap lanyards around or allow them to come in contact with sharp or rough edges.
- Fasten the other end of the lanyard outside the working area so that a falling tool is held securely.
- Attach the lanyard so that the tool will move away from the operator if it falls. Dropped tools will swing on the lanyard, which could cause injury or loss of balance.
- Do not use near moving parts or running machinery. Failure to do so may result in a crush or entanglement hazard.
- Do not carry the tool by the attachment device or the lanyard.
- Only transfer the tool between your hands while you are properly balanced.
- Do not attach lanyards to the tool in a way that keeps switches or trigger-lock (if supplied) from operating properly.
- Avoid getting tangled in the lanyard.
- Keep lanyard away from the drilling area of the tool.
- Use a locking carabiner (multi-action and screw gate type). Do not use single action spring clip carabiners.
- In the event the tool is dropped, it must be tagged and removed from service, and should be inspected by a Makita Factory or Authorized Service Center.
Torque limiter
NOTICE: As soon as the torque limiter actuates, switch off the tool
immediately. This will help prevent premature wear of the tool.
NOTICE: Drill bits such as hole saw, which tend to pinch or catch easily
in the hole, are not appropriate for this tool. This is because they will
cause the torque limiter to actuate too frequently.
The torque limiter will actuate when a certain torque level is reached. The
motor will disengage from the output shaft. When this happens, the drill bit
will stop turning.
Electronic function
The tool is equipped with the electronic functions for easy operation.
-
Electric brake
This tool is equipped with an electric brake. If the tool consistently fails to quickly cease to function after the switch trigger is released, have the tool serviced at a Makita service center. -
Constant speed control
The speed control function provides the constant rotation speed regardless of load conditions. -
Active Feedback sensing Technology
If the tool is swung at the predetermined acceleration during operation, the motor is forcibly stopped to reduce the burden on the wrist.
NOTE: This function does not work if the acceleration does not reach the
predetermined one when the tool is swung.
NOTE: If the bit is swung at the predetermined acceleration during
chipping, scaling, or demolishing, the motor is forcibly stopped. In this
case, release the switch trigger, and then pull the switch trigger to restart
the tool.
ASSEMBLY
CAUTION: Always be sure that the tool is switched off and the battery
cartridge is removed before carrying out any work on the tool.
Side grip (auxiliary handle)
CAUTION: Always use the side grip to ensure safe operation.
CAUTION: After installing or adjusting the side grip, make sure that the
side grip is firmly secured with its retaining projections fully engaged by
the positioning recesses on the gear housing.
To install the side grip, follow the steps below.
-
Loosen the thumb screw on the side grip. Then install the side grip over the barrel neck of the gear housing.
► Fig.13: 1. Side grip 2. Thumb screw 3. Barrel neck of the gear housing 4. Retaining projection 5. Positioning recess
The attachment ring can be enlarged by pressing the thumb screw down so that the ring is easily and securely engaged over the barrel neck of the gear housing.
► Fig.14: 1. Thumb screw 2. Attachment ring -
Tighten the thumb screw to secure the grip at your desired angle.
Grease
Optional accessory
Coat the shank end of the drill bit beforehand with a small amount of grease
(about 0.5 – 1 g).
This chuck lubrication assures smooth action and longer service life.
Clean the shank end of the drill bit and apply grease before installing the
drill bit.
► Fig.15: 1. Shank end 2. Grease
Place the shank end of the drill bit into the chuck, and insert it further
into the chuck while hand-turning the drill bit so the shankend well fits into
the chuck slot and becomes fully engaged. Having installed the drill bit, try
pulling it back to ensureit is securely held in place.
► Fig.16: 1. Drill bit 2. Chuck
To remove the drill bit, push the chuck cover down allthe way and pull the
drill bit out.
► Fig.17: 1. Drill bit 2. Chuck cover
Chisel angle (when chipping, scaling or demolishing)
The chisel can be secured at the desired angle. Switch the action mode
changing knob to the O symbol, and then turn the chisel to your desired angle.
► Fig.18: 1. Action mode changing knob 2. O symbol
Switch the action mode changing knob to the symbol. Try hand-turning the
chisel to ensure it is securely held in place.
Depth gauge
The depth gauge is convenient for drilling holes of uniform depth. Press
and hold the lock button, and then insert the depth gauge into the hex hole.
Make sure that the toothed side of the depth gauge faces the toothed marking
on the hex hole.
► Fig.19: 1. Depth gauge 2. Lock button 3. Hex hole 4. Toothed side 5. Toothed
marking
Adjust the depth gauge by moving it back and forth while pressing the lock
button. After the adjustment, release the lock button to lock the depth gauge.
NOTE: Make sure that the depth gauge does not touch the main body of the
tool when attaching it.
Dust collection system
Optional accessory
Installation
-
Slide the air duct cap out of the motor housing while lifting the lock tab up to the unlocked position.
► Fig.20: 1. Air duct cap 2. Lock tab -
Mount the tool onto the dust collection system bysliding the guide grooves on bottom surface of the gearhousing over the guide rails on top surface of the dust collection system until it locks in place with a click.
► Fig.21: 1. Guide grooves 2. Guide rails 3. Dust collection system
Uninstallation
-
Dismount the tool from the dust collection system by sliding the tool away off while pressing the lock off button on the dust collection system.
► Fig.22: 1. Dust collection system 2. Lock off button -
Slide the air duct cap back along the guide grooves on gear housing until it locks in place with a click.
► Fig.23: 1. Air duct cap 2. Guide grooves
NOTICE: Make sure to place the air duct cap back over the air duct after detaching the dust collection system from the tool. Tool performance can be affected if it is operated without the air duct cap in place.
Adjusting nozzle position
Slide in and out the nozzle guide while pressing the guide adjustment button,
and then release the button at an exact position where the tip of the drill
bit sits just behind the front surface of the nozzle.
► Fig.24: 1. Nozzle guide 2. Guide adjustment button 3. Tip of drill bit 4.
Front surface of nozzle
NOTE: Before adjusting the nozzle position, press the guide adjustment
button to release the tension on the nozzle guide and set it free into a fully
extended position.
Adjusting drilling depths
Drilling depth can be adjusted by changing the lengths between the depth
adjustment button and rear end of the nozzle guide. Press and hold the depth
adjustment button and slide it to your desired position.
► Fig.25: 1. Depth adjustment button 2. Nozzle guide 3. Drilling depths
Storage
NOTICE: When not in use for a certain period of time, the nozzle guide
needs to be extended to approximately 100 mm from its fully shortened
position. Failing to do so may damage the duct hose pre-installed in the
nozzle guide.
► Fig.26: 1. Guide adjustment button 2. Approx. 100 mm
Dust cup
Optional accessory
Use the dust cup to prevent dust from falling over the tool and on yourself
when performing overhead drilling operations. Attach the dust cup to the bit
as shown in the figure. The size of bits which the dust cup can be attached to
is as follows.
Model | Bit diameter |
---|---|
Dust cup 5 | 6 mm – 14.5 mm |
Dust cup 9 | 12 mm – 16 mm |
► Fig.27: 1. Dust cup
Dust cup set
Optional accessory
CAUTION: Before installing and uninstalling the dust cup set, remove a
bit from the tool.
Installation
Installation Place the dust cup set onto the barrel neck of the gearhousing aligning the symbol on the dust cup with one of the grooves in the barrel. Then hold the attachment unit of the dust cup set and push it down onto thebarrel to secure it in place.
► Fig.28: 1. Dust cup set 2. Attachment unit 3. symbol 4. Groove
NOTE: If you connect a vacuum cleaner to the dust cup set, remove the
dust cap before connecting it.
► Fig.29: 1. Dust cap
Uninstallation
Push the chuck cover down all the way and pull a bit off.
► Fig.30: 1. Bit 2. Chuck cover
Hold the attachment unit of the dust cup set and pull it apart from the tool.
► Fig.31: 1. Attachment unit
NOTE: If the cap comes off from the dust cup set, place it back to the
original position.
-
Detach the bellows from the attachment unit of the dust cup set.
► Fig.32: 1. Bellows 2. Attachment unit -
Set the cap back in place with its printed side facing upwards.
► Fig.33: 1. Cap 2. Printed side 3. Grooves 4. Lips of upper opening 5. Attachment unit -
Be sure that the grooves around the cap well fit in the lips of the upper opening of the attachment unit.
► Fig.34
OPERATION
CAUTION: Always use the side grip (auxiliary handle) and firmly hold the
tool by both side grip and switch handle during operations.
CAUTION: Always make sure that the workpiece is secured before operation.
CAUTION: Do not pull the tool out forcibly even the bit gets stuck. Loss
of control may cause injury.
CAUTION: The dust collection system is intended for drilling in concrete
only. Do not use the dust collection system for drilling in metal or wood.
CAUTION: When using the tool with the dust collection system, be sure to
attach the filter to the dust collection system to prevent dust inhalation.
CAUTION: Before using the dust collection system, check that the filter
is not damaged. Failure to do so may cause dust inhalation.
CAUTION: The dust collection system collects the generated dust at a
considerable rate, but not all dust can be collected.
NOTICE: If the tool is operated continuously at low speed for a long
time, the motor will get overloaded, resulting in tool malfunction.
NOTICE: Do not use the dust collection system for core drilling or
chiseling.
NOTICE: Do not use the dust collection system for drilling in wet
concrete or use this system in wet environment. Failure to do so may cause
malfunction.
NOTE: If the battery cartridge is in low temperature, the tool’s
capability may not be fully obtained. In this case, warm up the battery
cartridge by using the tool with no load for a while to fully obtain the
tool’s capability.
► Fig.35
Hammer drilling operation
CAUTION: There is tremendous and sudden twisting force exerted on the
tool/drill bit at the time of hole break-through, when the hole becomes
clogged with chips and particles, or when striking reinforcing rods embedded
in the concrete. Always use the side grip (auxiliary handle) and firmly hold
the tool by both side grip and switch handle during operations. Failure to do
so may result in the loss of control of the tool and potentially severe
injury.
Set the action mode changing knob to the symbol. Position the drill bit at the
desired location for the hole, then pull the switch trigger.
Apply feed force to the switch handle (main handle) for working accuracy and
efficiency, and hold the side grip (auxiliary handle) to keep balance of the
tool. Keep the tool in position and prevent it from slipping away from the
hole.
Do not apply more pressure when the hole becomes clogged with chips or
particles. Instead, run the tool at an idle, then remove the drill bit
partially from the hole. By repeating this several times, the hole will be
cleaned out and normal drilling may be resumed.
NOTE: Eccentricity in the drill bit rotation may occur while operating
the tool with no load. The tool automatically centers itself during operation.
This does not affect the drilling precision.
Chipping/Scaling/Demolition
Set the action mode changing knob to the symbol. Hold the tool firmly with
both hands. Turn the tool on. Apply feed force to the switch handle (main
handle) for working accuracy and efficiency, and hold the side grip (auxiliary
handle) to keep balance of the tool. Pressing very hard on the tool will not
increase the efficiency.
► Fig.36
Drilling in wood or metal
CAUTION: Hold the tool firmly and exert carewhen the drill bit begins to
break through the workpiece. There is a tremendous force exerted onthe
tool/drill bit at the time of hole break through.
CAUTION: A stuck drill bit can be removed simply by setting the reversing
switch to reverserotation in order to back out. However, the tool may back out
abruptly if you do not hold it firmly
CAUTION: Always secure workpieces in a vise or similar hold-down device.
NOTICE: Never use “rotation with hammering” when the drill chuck is
installed on the tool. The drill chuck may be damaged. Also, the drill chuck
will come off when reversing the tool.
NOTICE: Pressing excessively on the tool will not speed up the drilling.
In fact, this excessive pressure will only serve to damage the tip of your
drill bit, decrease the tool performance and shorten the service life of the
tool.
Set the action mode changing knob to the symbol.
Installing drill chuck set
Optional accessory
Attach the chuck adapter to a keyless drill chuck to which 1/2″-20 size screw
can be installed, and then install them to the tool. For details on how to
install the adapter into the chuck, refer to the instructions on installing
drill bit.
► Fig.37: 1. Keyless drill chuck 2. Chuck adapter
Diamond core drilling
NOTICE: If performing diamond core drilling operations using “rotation
with hammering” action, the diamond core bit may be damaged. When performing
diamond core drilling operations, always set the action mode changing knob to
the position to use “rotation only” action.
Beating dust on the filter
Optional accessory
CAUTION: Do not turn the dial on the dust case while the dust case is
removed from the dust collection system. Doing so may cause dust inhalation.
CAUTION: Always switch off the tool when turning the dial on the dust
case. Turning the dial while the tool is running may result in the loss of
control of the tool.
By beating the dust on the filter inside the dust case, you can keep the
vacuum efficiency and also reduce the number of times to dispose of the dust.
Turn the dial on the dust case three times after collecting every 50,000 mm³
of dust or when you feel the vacuum performance declined.
NOTE: 50,000 mm³ of dust equivalents to drilling 10 holes of ø10 mm and 65 mm
depth.
► Fig.38: 1. Dust case 2. Dial
Disposing of dust
Optional accessory
CAUTION: Always be sure that the tool is switched off and the battery
cartridge is removed before carrying out any work on the tool.
CAUTION: Be sure to wear dust mask when disposing of dust.
CAUTION: Empty the dust case regularly before the dust case becomes full.
Failure to do so may decrease the dust collection performance and cause dust
inhalation.
CAUTION: The performance of dust collection decreases if the filter in
the dust case become clogged. Replace the filter with new one after
approximately 200 times of dust fulfillment as a guide. Failure to do so may
cause dust inhalation.
-
Remove the dust case while pressing down the latch lever of the dust case.
► Fig.39: 1. Latch lever -
Lift the lock tab slightly outwards and open the dust case cover.
► Fig.40: 1. Dust case cover 2. Lock tab -
Dispose of the dust, and then clean the filter.
► Fig.41
NOTICE: When cleaning the filter, tap the case of the filter gently by
hand to remove dust. Do not tap the filter directly; touch the filter with
brush or similar; or blow compressed air on the filter. Doing so may damage
the filter.
Blow-out bulb
Optional accessory
After drilling the hole, use the blow-out bulb to clean the dust out of the
hole.
► Fig.42
Using dust cup set
Optional accessory
Fit the dust cup set against the ceiling when operating the tool.
► Fig.43
NOTICE: Do not use the dust cup set when drill-ing in metal or similar.
It may damage the dust cup set due to the heat produced by small metal dust or
similar.
NOTICE: Do not install or remove the dust cup set with the drill bit
installed in the tool. It may damage the dust cup set and cause dust leak.
WIRELESS ACTIVATION FUNCTION
What you can do with the wireless activation function
The wireless activation function enables clean and comfortable operation.
By connecting a supported vacuum cleaner to the tool, you can run the vacuum
cleaner automatically along with the switch operation of he tool.
► Fig.44
To use the wireless activation function, prepare following items:
- A wireless unit (optional accessory)
- A vacuum cleaner which supports the wireless activation function
The overview of the wireless activation function setting is as follows. Refer to each section for detail procedures.
- Installing the wireless unit
- Tool registration for the vacuum cleaner
- Starting the wireless activation function
Installing the wireless unit
Optional accessory
CAUTION: Place the tool on a flat and stable surface when installing
the wireless unit.
NOTICE: Clean the dust and dirt on the tool before installing the
wireless unit. Dust or dirt may cause malfunction if it comes into the slot of
the wireless unit.
NOTICE: To prevent the malfunction caused by static, touch a static
discharging material, such as a metal part of the tool, before picking up the
wireless unit.
NOTICE: When installing the wireless unit, always be sure that the
wireless unit is inserted in the correct direction and the lid is completely
closed.
-
Open the lid on the tool as shown in the figure.
► Fig.45: 1. Lid -
Insert the wireless unit to the slot and then close the lid.
When inserting the wireless unit, align the projections with the recessed portions on the slot.
► Fig.46: 1. Wireless unit 2. Projection 3. Lid 4. Recessed portion
When removing the wireless unit, open the lid slowly.
The hooks on the back of the lid will lift the wireless unit as you pull up
the lid.
► Fig.47: 1. Wireless unit 2. Hook 3. Lid
After removing the wireless unit, keep it in the supplied case or a static-
free container.
NOTICE: Always use the hooks on the back of the lid when removing the
wireless unit. If the hooks do not catch the wireless unit, close the lid
completely and open it slowly again.
Tool registration for the vacuum cleaner
NOTE: A Makita vacuum cleaner supporting the wireless activation function
is required for the tool registration.
NOTE: Finish installing the wireless unit to the tool before starting the
tool registration.
NOTE: During the tool registration, do not pull the switch trigger or
turn on the power switch on the vacuum cleaner.
NOTE: Refer to the instruction manual of the vacuum cleaner, too.
If you wish to activate the vacuum cleaner along with the switch operation of the tool, finish the tool registration beforehand.
-
Install the batteries to the vacuum cleaner and the tool.
-
Set the stand-by switch on the vacuum cleaner to “AUTO”.
► Fig.48: 1. Stand-by switch -
Press the wireless activation button on the vacuum cleaner for 3 seconds until the wireless activation lamp blinks in green. And then press the wireless activation button on the tool in the same way.
► Fig.49:
- Wireless activation button
- Wireless activation lamp
If the vacuum cleaner and the tool are linked successfully, the wireless
activation lamps will light up in green for 2 seconds and start blinking in
blue.
NOTE: The wireless activation lamps finish blinking in green after 20
seconds elapsed. Press the wireless activation button on the tool while the
wireless activation lamp on the cleaner is blinking. If the wireless
activation lamp does not blink in green, push the wireless activation button
briefly and hold it down again.
NOTE: When performing two or more tool registrations for one vacuum
cleaner, finish the tool registration one by one.
Starting the wireless activation function
NOTE: Finish the tool registration for the vacuum cleaner prior to the
wireless activation.
NOTE: Refer to the instruction manual of the vacuumcleaner, too.
After registering a tool to the vacuum cleaner, the vacuum cleaner will automatically runs along with the switch operation of the tool.
-
Install the wireless unit to the tool.
-
Connect the hose of the vacuum cleaner with the tool.
► Fig.50 -
Set the stand-by switch on the vacuum cleaner to “AUTO”.
► Fig.51: 1. Stand-by switch -
Push the wireless activation button on the tool briefly. The wireless activation lamp will blink in blue.
► Fig.52: 1. Wireless activation button 2. Wireless activation lamp -
Turn on the tool. Check if the vacuum cleaner runs while the tool is operating.
To stop the wireless activation of the vacuum cleaner, push the wireless activation button on the tool.
NOTE: The wireless activation lamp on the tool will stop blinking in blue
when there is no operation for 2 hours. In this case, set the stand-by switch
on the vacuum cleaner to “AUTO” and push the wireless activation button on the
tool again.
NOTE: The vacuum cleaner starts/stops with a delay. There is a time lag
when the vacuum cleaner detects a switch operation of the tool.
NOTE: The transmission distance of the wireless unit may vary depending
on the location and surrounding circumstances.
NOTE: When two or more tools are registered to one vacuum cleaner, the
vacuum cleaner may start running even if you do not turn on your tool because
another user is using the wireless activation function.
Description of the wireless activation lamp status
► Fig.53: 1. Wireless activation lamp
The wireless activation lamp shows the status of the wireless activation
function. Refer to the table below for the meaning of the lamp status.
Status | Wireless activation lamp | Description |
---|---|---|
Color | On | Blinking |
Standby | Blue |
available. The lamp will automatically turn off when no operation is performed
for 2 hours.
| When the tool
is running.| The wireless activation of the vacuum cleaner is available and
the tool is running.
Tool
registration| Green| | 20 seconds| Ready for the tool registration. Waiting
for the registration by the vacuum cleaner.
| 2 seconds| The tool registration has been finished. The wireless activation
lamp will start blinking in blue.
Cancelling
tool
registration| Red| | 20 seconds| Ready for the cancellation of the tool
registration. Waiting for the cancellation by the vacuum cleaner.
| 2 seconds| The cancellation of the tool registration has been finished. The
wireless activation lamp will start blinking in blue.
Others| Red| | 3 seconds| The power is supplied to the wireless unit and the
wireless activation function is starting up.
Off| –| –| The wireless activation of the vacuum cleaner is stopped.
Cancelling tool registration for the vacuum cleaner
Perform the following procedure when cancelling the tool registration for the vacuum cleaner.
-
Install the batteries to the vacuum cleaner and the tool.
-
Set the stand-by switch on the vacuum cleaner to “AUTO”.
► Fig.54: 1. Stand-by switch -
Press the wireless activation button on the vacuum cleaner for 6 seconds. The wireless activation lamp blinks in green and then become red. After that, press the wireless activation button on the tool in the same way.
► Fig.55:
1. Wireless activation button
2. Wireless activation lamp
If the cancellation is performed successfully, the wireless activation lamps
will light up in red for 2 second sand start blinking in blue.
NOTE: The wireless activation lamps finish blinking in red after 20
seconds elapsed. Press the wireless activation button on the tool while the
wireless activation lamp on the cleaner is blinking. If the wireless
activation lamp does not blink inred, push the wireless activation button
briefly and hold it down again.
Troubleshooting for wireless activation function
Before asking for repairs, conduct your own inspection first. If you find a problem that is not explained in the manual, do not attempt to dismantle the tool. Instead, ask Makita Authorized Service Centers, always using Makita replacement parts for repairs.
State of abnormality | Probable cause (malfunction) | Remedy |
---|---|---|
The wireless activation lamp does not light/blink. | The wireless unit is rot |
installed into the tool. The wireless unit is improperly installed into the
tool.| Install the wireless unit correctly.
The terminal of the wireless unit and/or the slot is dirty.| Gently wipe off
dust and dirt on the terminal of the wireless unit and clean the slot.
The wireless activation button on the tool has not been pushed.| Push the
wireless activation button on the tool briefly.
The stand-by switch on the vacuum cleaner is not set to ‘AUTO’.| Set the
stand-by switch on the vacuum cleaner to ‘AUTO.
No power supply| Supply the power to the tool and the vacuum cleaner.
Cannot finish tool registration I can-
ceiling tool registration successfully.| The wireless unit is rot installed
into the tool. The wireless unit is improperly installed into the tool.|
Install the wireless unit correctly.
The terminal of the wireless unit and/or the slot is dirty.| Gently wipe off
dust and dirt on the terminal of the wireless unit and dean the slot.
The stand-by switch on the vacuum cleaner is not set to ‘AUTO’.| Set the
stand-by switch on the vacuum cleaner to ‘AUTO.
No power supply| Supply the power to the tool and the vacuum cleaner.
Incorrect operation| Push the wireless activation button briefly and perform
the tool registration/cancellation procedures again.
The tool and vacuum cleaner are away from each other (out of the transmission
range).| Get the tool and vacuum cleaner closer to each other. The maximum
transmission distance is approximately 10 m however it may vary according to
the circumstances.
Before finshing the tool regstrabontancellaton: – the switch of the tool is
turned on or:
– the power button on the vacuum cleaner is turned on.| Push the wireless
activation button briefly and perform the tool registration/cancellation
procedures again.
The tool registration procedures for the tool or vacuum cleaner have not
finished.| Perform the tool registration procedures for both the tool and the
vacuum cleaner at the same timing.
Radio disturbance by other appliances which generate high-intensity radio
waves.| Keep the tool and vacuum cleaner away from the appliances such as Wi-
Fi devices and microwave ovens.
The vacuum cleaner does not run along with the switch operation of the tool.|
The wireless unit is not installed No the tool. The wireless unit is
improperly installed into the tool.| Install the wireless unit correctly.
The terminal of the wireless unit and/or the slot is dirty.| Gently wipe off
dust and dirt on the terminal of the wireless unit and dean the slot.
The wireless activation button on the tool has not been pushed.| Push the
wireless activation button briefly and make sure that the wireless activation
lamp is blinking in blue.
The stand-by switch on the vacuum cleaner is not set to AUTO’.| Set the
stand-by switch on the vacuum cleaner to AUTO*.
More than 10 tools are registered to the vacuum cleaner.| Perform the tool
registration again.
If more than 10 tools are registered to the vacuum cleaner, the tool
registered earliest will be cancelled automatically.
Thevecutrn cleaner erased all tool resistrabons.| Perform the tool
registration again.
No power supply| Supply the power to the tool and the vacuum cleaner.
The tool and vacuum cleaner are away from each other (out of the transmission
range).| Get the tool and vacuum cleaner closer each other. The maximum
transmission distance is approximatey 10 m however it may vary according to
the circumstances.
Radio disturbance by other appliances which generate high-intensity radio
waves.| Keep the tool and vacuum cleaner away from the appliances such as Wi-
Fi devices and microwave ovens.
The vacuum cleaner runs Mile the tool is not operating.| Other users are using
the wireless activation of the vacuum cleaner with their tools.| Turn off the
wireless activation button of the other tools or cancel the tool registration
of the other tools.
MAINTENANCE
CAUTION: Always be sure that the tool is switched off and the battery
cartridge is removed before attempting to perform inspection or maintenance.
NOTICE: Never use gasoline, benzine, thinner, alcohol or the like.
Discoloration, deformation or cracks may result.
To maintain product SAFETY and RELIABILITY, repairs, any other maintenance or
adjustment should be performed by Makita Authorized or Factory Service
Centers, always using Makita replacement parts.
Replacing filter of dust case
Optional accessory
-
Remove the dust case while pressing down the latch lever of the dust case.
► Fig.56: 1. Latch lever -
Lift the lock tab slightly outwards and open the dust case cover.
► Fig.57: 1. Dust case cover 2. Lock tab -
Insert a flat-blade screwdriver in between the filter case and dust case cover as shown in the figure. Press the side walls of the filter case inwards, and lift the filter case up off using the flat-blade screwdriver.
► Fig.58: 1. Flat-blade screwdriver 2. Filter case -
Dust case cover
-
Push the filter out of the filter case as shown in the figure.
► Fig.59: 1. Filter 2. Filter case -
Replace a new filter in the filter case. Set the filter case back onto the dust case aligning the guide projection on the filter case with the groove in the dust case.
► Fig.60:
1. Guide projection 2. Groove -
Close the dust case cover, and then reassemble the dust case to the dust collection system.
Replacing sealing cap
Optional accessory
Replace a sealing cap at regular intervals as a worn or damaged sealing cap
may affect the suction performance.
-
Insert a flat-blade screwdriver, with its flat surfaces vertical, into one of the release holes placed on the sides of the nozzle head. Tilt the flat-blade screwdriver at an angle to squeeze and pop the cube hook of the sealing cap out of the molded receptacle. Then peel therubber edges of the sealing cap away from the rims of the nozzle head opening.
► Fig.61: 1. Sealing cap 2. Cube hook 3. Release hole 4. Nozzle head -
Set one of cube hooks of a renewed sealing cap into the molded receptacle in the nozzle head with a recessed surface of the sealing cap facing forwards.
► Fig.62: 1. Cube hooks 2. Receptacles 3. Sealing cap 4. Recessed surface -
Place the other hook into the receptacle on the opposite side of the nozzle head, while repositioning the sealing cap to fit finely to the nozzle head.
► Fig.63: 1. Sealing cap 2. Cube hook 3. Receptacle 4. Nozzle head 5. Rims -
Gently lay the rubber edges of the sealing cap down over the rims of the nozzle head opening from bottom to top.
► Fig.64: 1. Rubber edges 2. Sealing cap 3. Nozzle head
OPTIONAL ACCESSORIES
CAUTION: These accessories or attachments are recommended for use with
your Makita tool specified in this manual. The use of any other accessories or
attachments might present a risk of injury to persons. Only use accessory or
attachment for its stated purpose.
If you need any assistance for more details regarding these accessories, ask
your local Makita Service Center.
- Carbide-tipped drill bits (SDS-Plus carbide-tipped bits)
- Core bit
- Bull point
- Diamond core bit
- Cold chisel
- Scaling chisel
- Grooving chisel
- Drill chuck set (chuck adapter / drill chuck)
- Bit grease
- Depth gauge
- Blow-out bulb
- Dust cup
- Dust cup set
- Hook set
- Dust case set
- Filter set
- Joint
- Dust collection system
- Wireless unit
- Safety goggles
- Makita genuine battery and charger
NOTE: Some items in the list may be included in the tool package as standard accessories. They may differ from country to country.
Makita Europe N.V.
Jan-Baptist Vinkstraat 2,
3070 Kortenberg, Belgium
Makita Corporation
3-11-8, Sumiyoshi-cho,
Anjo, Aichi 446-8502 Japan
885920A994
EN, FR, DE, IT, NL,
ES, PT, DA, EL, TR
20220520
www.makita.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>