BMGI EGA-04 Control Board Instruction Manual
- June 10, 2024
- BMGI
Table of Contents
Installation &
User Manual
EGA-04 Controller Scan the QR Codes
below for further assistance
EGA-04 Control Board
| |
---|---|---
https://bmgi.com.au/converting-d1-board-to-ega- board
|
https://bmgi.com.au/product-manuals
|
https://bmgi.com.au/en-au/ega-control-board-videos
IMPORTANT
If you are converting your D1 control board to the EGA control board Please
visit the link below for wiring instructions or scan the QR code above
https://bmgi.com.au/converting-d1-board-to-ega-board
Copyright © 2023 BMGi. All Rights Reserved.
Setting Up Your Control Board
After installing the actuator arm/s and completing the wiring, have the gate/s
in the open position.
If your unit is an ELECTRIC kit with a TRANSFORMER, turn your transformer on
now. The control board will make a “BEEP” sound and then run through a start-
up sequence which you will see on the digital display labelled MENU.
Wait 10 seconds for the control board to finalise this step.
If your unit is a SOLAR POWERED kit, connect the SOLAR PANEL to your regulator
and connect the battery up to the power cables. The control board will make a
“BEEP” sound and then run through a start-up sequence which you will see on
the digital display labelled MENU. Wait 10 seconds for the control board to
finalise this step.
If your control board came to you with compatible remotes, then they will
already be tuned in.
If converting from the D1 board to the EGA then you will have wired in your
existing receiver with the black remote and red/green buttons. Below will not
relate to you.
Compatible remotes for the EGA control board For a dual swing gate, your
remote buttons will be:
Button A Controls Dual gate open / close
Button B Spare button, not in use.
Button C Party mode, this feature overrides auto close.
Auto close is turned off, you will need to turn this on yourself if you would like this feature.
Refer to Menu settings to set this up.
Button D Spare button, not in use.
For a single swing gate, your remote buttons will be:
Button A Controls Single gate open / close
Button B Spare button, not in use.
Button C Party mode, this feature overrides auto close.
Auto close is turned off, you will need to turn this on yourself if you would like this feature.
Refer to Menu settings to set this up.
Button D Spare button, not in use.
Auto Travel Function
IMPORTANT – Dual swing AUTO TRAVEL procedure:
ENSURE THE GATE WAY ENTRANCE IS CLEAR OR ANY OBSTRUCTIONS.
https://bmgi.com.au/en-au/ega-control-board-videos
To perform the ‘AUTO TRAVEL’ function, you will need to activate your gate
opener with a remote. Press Remote Button (or the remote you are using for
this system) for 2 seconds or until the small LED light on the remote
flickers, now release your remote button. You should observe “OP” appearing on
the Digital Display “MENU”.
For a dual swing gate, the display “MENU” will show OP to say the control
board has put Motor 1 gate into an OPEN position, the “MENU” will then show SP
to say the control board has turned Motor 1 off. The display “MENU” will
repeat this sequence for Motor 2.
With the control board now knowing your gates are in the open position, you
will need to press the DEC and INC buttons at the same time for 5 seconds or
until one gate starts to close, now release INC and DEC buttons (you must
press and hold in both buttons at the same time for this to work, pressing the
buttons individually first will not allow the control board to run its ‘AUTO
TRAVEL’ function).
The gate connected to Motor 1 will close first, the “MENU” will display CL
(Close), after Motor 1 has closed the gate, the “MENU” willdisplay SP (Stop).
Motor 2 will now close with the “MENU” displaying CL (Close), after Motor 2
has closed the gate, the “MENU” will display SP (Stop). 1 second after Motor
2 has closed the gate it will activate again with the “MENU displaying OP
(Open), after Motor 2 has opened the gate, the “MENU” will display SP (Stop).
Motor 1 will now open the gate with the “MENU” displaying OP (Open), once the
gate is open the “MENU” will display SP (Stop). Wait 10 seconds before
operating the gate opener.
Travel function completed. Press the remote trigger button on your remote for
2 seconds or until the LED light starts to flicker and then release the
button.
Check that your gates operate correctly. Check if your force settings need to
be adjusted. If they require adjusting, please refer to the MENU settings to
adjust P1 through to P4 as well as P5 and P6.
IMPORTANT – Single swing AUTO TRAVEL procedure: ENSURE THE GATE WAY
ENTRANCE IS CLEAR OR ANY OBSTRUCTIONS.
https://bmgi.com.au/en-au/ega-control-board-videos
To perform the ‘AUTO TRAVEL’ function, you will need to activate your gate
opener with a remote. Press Remote Button (or the remote you are using for
this system) for 2 seconds or until the small LED light on the remote
flickers, now release your remote button. You should observe “OP” appearing on
the Digital Display “MENU”.
For a Single swing gate, the display “MENU” will show OP to say the control
board has put Motor 2 gate into an OPEN position, the “MENU” will then show SP
to say the control board has turned Motor 2 off.
With the control board now knowing your gate is in the open position, you will
need to press the DEC and INC buttons at the same time for 5 seconds or until
one gate starts to close, now release INC and DEC buttons (you must press and
hold in both buttons at the same time for this to work, pressing the buttons
individually first will not allow the control board to run its ‘AUTO TRAVEL’
function).
The gate Motor 2 will now close with the display “MENU” displaying CL (Close),
after Motor 2 has closed the gate, the “MENU” will display SP (Stop). 1
second after Motor 2 has closed the gate it will activate again with the “MENU
displaying OP (Open), after Motor 2 has opened the gate, the “MENU” will
display SP (Stop). Wait 10 seconds before operating the gate opener.
Travel function now completed.
Press remote trigger button on your remote for 2 seconds or until the LED
light starts to flicker, then release the button.
Check that your gate operates correctly. Check if your force settings need to
be adjusted.
If they require adjusting, please refer to the MENU settings to adjust P3, P4
and P6.
Majority of gates won’t require any adjustments.
Remotes
Remote Learning – compatible remotes with A, B, C, D buttons with the Orange
LED light – similar remotes with different colour light may not work.
To learn new remotes to your control board.
Press the Learn button for 1 seconds and then release. The STATE red LED light
will go out. Now press button A on your remote once for 2 seconds or until LED
light begins to flash, the control board will “BEEP” once and display the
remote number you just learnt.
Remote 1 will show 01, remote 5 will show 05 etc.
The STATE red LED light will come back on solid.
Your remote is now tuned in.
Button A and C will automatically be assigned functions.
These functions cannot be altered or removed.
Button A | Full open / close for Dual swing gates and Single swing gates |
---|---|
Button B | Empty |
Button C | Party mode function. Party mode is used to override auto close. It |
will override P9 auto close functions. You must be within 1 metre of the
gate to ensure you are within working range for the remote.
Button D| Empty
Button C Party mode, this feature overrides auto close.
Auto close is turned off when you receive the kit, you will need to turn this
on yourself if you would like this feature. Refer to Menu settings to set this
up. To disable auto close, press button A on your remote to open your gate,
once the gate has reached the full open position, wait 2 seconds, now press
button C on your remote for 2 seconds or until the orange LED light comes on
for your remote.
You should be within 1 metre of the control box when activating this function
to ensure the signal has been picked up by the control board. Now wait for the
auto close time to pass to ensure you have successfully bypassed the auto
close function.
When you are ready to close the gate, press Button A on you remote or any
triggering devices you might have e.g. push button or keypad. Your auto close
function will be reactivated for the next time the gate is opened.
Remotes
Erasing Remotes
Press and hold the Learn button for 8 seconds, the buzzer will beep and the
digital display will read 00. At this time, all the information stored in the
on board receiver has been deleted, release the Learn button.
Remote distance – up to 30 metres. This distance will vary greatly due to site
interference that may not be visible to the eye. Some sites will allow for
greater range than 30 metres, some sites might only achieve 5 metres.
Remote frequency – Rolling code 433mhz
*Only genuine remotes will operate with the on board receiver. To ensure your remote is a genuine remote, you will notice the small LED light will flicker an ORANGE colour when you press one of the 4 buttons on your remote for 2 seconds or until the light starts to flicker.
Remote Storage – The on board receiver can store up to 120 remotes.
Menu Settings
To enter the Menu settings, the gate/s must be in either the full Open or full
Close position, the control board will not allow you to enter the Menu
settings while the gate opener is operating.
Press and hold “FUN” button for 2 seconds or until the Digital Display shows
P0. From here use “DEC” or “INC” buttons to go down or up the menu list, once
you are on the menu setting you need, press “FUN” button once to enter
the setting. Now use “DEC” or “INC” to decrease or increase the parameter
number, once you have selected the parameter number you require, press the
“FUN” button to confirm the new setting.
To exit the menu setting, press the “Learn” button once. Now test your
adjusted settings.
Menu 1| Main Feature| I Parameter| I Parameter I Feature|
Detailed Description
---|---|---|---|---
PO| Activates Single swing or Dual Swing mode| 0| Double Swing gate| BMG will
have the system set to match your unit when purchased with a gate opener kit.
1| Single Swing gate
(Default setting)| BMG will have the system set to match your unit when
purchased with a gate opener kit.
P1| Motor 1 open gate obstacle sensitivity| 1| 1 (Most Sensitive)| Adjust from
1 to 12, the higher the number, the greater force required to stop the
gate. For heavy gates or long gates, you may need to adjust this setting to a
higher number. The lower the number the easier it is to stop the gate. For
light weight gates or short gates, you may need to adjust this setting to a
lower number.
The current of the motor running in the 12V system is relatively large, it is
recommend-ed to set the value between 5-12 levels.
…| Factory set 7
12| 12 (Less Sensitive)
P2| Motor 1 close gate obstacle sensitivity| 1| 1 (Most Sensitive)
| Factory set 7
12| 12 (Less Sensitive)
P3| Motor 2 open gate obstacle sensitivity| 1| 1 (Most Sensitive)
| Factory set 7
12| 12 (Less Sensitive)
P4| Motor 2 close gate obstacle sensitivity| 1| 1 (Most Sensitive)
…| Factory set 7
12| 12 (Less Sensitive)
P5| Motor 1 low speed obstruction sensitivity| 1| 1 (Most Sensitive)| Soft
stop force adjustment
| Factory set 8
12| 12 (slowest)
P6| Motor 2 low speed obstruction sensitivity| 1| 1 (Most Sensitive)| Soft
stop force adjustment
| Factory set 8
12
12 (slowest)
P7| Slow speed running time| 0| No slow speed| This adjusts the ramp down of
the gate. The slow speed can be adjusted (0 not recommended as this puts extra
stress on moving parts). For long gates we recommend the standard setting of
2.
1| Shortest
|
5| Longest
P8| Closing delay time| 0| No delay| This setting is for Dual Swing gates. You
can adjust the closing delay between the two motors. This is required if you
have an electric gate lock connected to the control board or if you require
Motor 1 to close first. You can set this from 0 seconds (open and close at the
same time) up to 8 seconds. Factory setting is 2 seconds and is recommended
even if a gate lock is not installed.
1| 1s
2| Factory Set 2s
…|
8| 8s
P9| Main Auto Closing| 0| Factory Set| Auto close setting can be set from 0
seconds (factory setting) up to 99 seconds.
1| 1s
—| ….
99| 99s
PA| Electric lock output mode| 0| Not output
(factory set)| This setting allows you to adjust the output to your optional
electric gate lock. Factory setting is 0 which is set for NO GATE LOCK. If you
install a gate lock, it is recommended you set PA to level 3 (3 seconds). This
may need to be adjusted depending on your gate setup.
If lock output is set 1 to 6, the lock will activate first for 1 second before
the gate starts, this is to allow time for the lock to activate.
1| 1s
—|
6| 6s
PB| Lamp output mode| 1| Mode 1
(factory set)| Set lamp work mode by menu PB , factory set mode 1
1:Lamp output on when motor operating, when motor stops lamp turns off
2:Lamp output flash when motor operating, when motor stops lamp turns off
3:Lamp output on when motor operating, after motor turns off 30 seconds later
the lamp output turns off
4:Lamp output flashing when motor operating, after motor turns off 30 seconds
later the lamp output turns off
2| Mode 2
3| Mode 3
4| Mode 4
PC| Electric lock auxiliary
function| 0| Open
(factory set)| Factory setting Motor 2 will activate after 1 second to allow
gate lock to release. Setting PC to 1 will make Motor 2 reverse (Close) for
0.5 seconds to help release pressure off the lock before allowing Motor 2 to
activate.
1| Close
Reverse first
PD| Infrared terminal set| 0| NO mode
(factory set)| If you run safety beams, you will need to set PD to 1. Factory
setting allows you to operate without safety beams.
1| NC mode
PE| Soft start time| 1| 1s (factory set)| You can adjust the soft start time
of your gate. This may need to be adjusted for longer gates and heavy gates
2| 2s
3| 3s
PF| Remote control mode| 0| One Gate Mode| If you have 2 gate opener kits on
the one property and are within 100 metres of each other, your control board
will be set to 01. This will have your remote set to:
Gate 1
Button A— Full open/close Button C — Party mode Gate 2
Button B — Full open/close Button D — Party mode
Factory set mode 01
1| Two Gates Mode
(factory set)
PP| System set| 0| Nothing| This setting will put your control board back to
factory settings and put your unit to Single swing gate. This would then need
to be adjusted to suit a double swing gate.
—-| —-
5| Factory reset
—-| —-
9| Nothing
Control Board Specifications and Details
Power Supply
Power Supply | AC12 V – AC16 V |
---|---|
Fuse | 10A |
External Accessory Power Supply | No more than 300mA |
Alarm Light Power Supply | No more than 500mA |
Electric Lock Power Supply | No more than 2.5A |
The EGA control board has been specifically designed for this kit and SHOULD
NOT be used for any other setup
CONTROL BOARD Tip:
Green connector blocks on the main control board can be removed to help with
wiring in cables
Control Board
Ant | Antenna for control board |
---|---|
2Side | Terminal for external device of controlling double gates |
Corn | Common for external device |
1Side | Terminal for external device of controlling single gate ( Motor2) |
Card | Terminal for external device for double gates OPEN ONLY |
Corn | Common for external device |
IR | Terminal for Photo beam sensor |
Corn | Common for Photo beam sensor |
12V+ | Power supply for external device |
Bat | Terminal for 12V Battery |
Lamp | Terminal for lamp |
Lock | Terminal for lock |
Accessory pins | Allows power through to the accessory terminals |
- Placing the jumper on the left 2 pins provides power from the transfomer
- Placing the jumper on the right 2 pins provides power from the battery
Instructions for Indicator
State Indicator| Steady on: Indicating that the system is working normally
Blinking at 1Hz: indicating that the system is in the mode of auto close or
travel learning.
Fast blinking: The system is error.
---|---
Terminal Indicator| On: The terminal is ON. Off: The terminal is OFF
Instructions for button
DEC | used for lowering values |
---|---|
FUNC | used for entering the menu and storing the settings |
INC | used for increasing values |
RF Learn | used for learning or removing remotes |
Installer & Owner Notes