BODYMED BDMOXMTRBLK Finger Pulse Oximeter User Manual
- June 10, 2024
- BODYMED
Table of Contents
- BDMOXMTRBLK Finger Pulse Oximeter
- Product Information
- Product Usage Instructions
- Safety
- Definitions and Symbols
- Intended Use and Introduction
- Installation, Setup, and Operation
- Turn Off the Pulse Oximeter
- Maintenance
- Troubleshooting
- Specification
- Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BDMOXMTRBLK Finger Pulse Oximeter
Product Information
The product is a pulse oximeter that measures the oxygen saturation level (SpO2) and pulse rate (PR) of an individual. The device has an LED panel that displays the measured data and a bar graph. It is powered by two AAA 1.5V alkaline batteries that have a normal power consumption of smaller than 30mA. The device has a working temperature range and a storage temperature range. It is labeled as Type BF equipment and has a serial number for identification.
Product Usage Instructions
To use the pulse oximeter, follow these steps:
- Insert two AAA 1.5V alkaline batteries into the battery compartment located at the back of the device.
- Press the power button to turn on the device.
- Place your finger on the sensor and ensure it is inserted deeply enough into the unit.
- Wait for the LED panel to display the SpO2 and PR data along with the bar graph.
- If the device cannot measure the SpO2 or PR, try reinserting your finger or remain calm and move as little as possible.
- If the device still cannot measure the SpO2 or PR after several tries, seek medical attention for an exact diagnosis.
- To turn off the device, press and hold the power button until the LED panel turns off.
Note: When disposing of the product, do not place it in regular trash. Instead, send it to a collection facility for appropriate recovery or recycling.
Safety
- Instructions for the Safe Operation and Use of the Pulse Oximeter
- Do not attempt to service the pulse oximeter. Only qualified service personnel should attempt any needed internal servicing.
- Do not use the oximeter in situations where alarms are required.
- Prolonged use or the user’s condition may require changing the sensor site periodically. Change sensor site and check skin integrity, circulatory status, and correct alignment at least every 2 hours.
- SpO2 measurements may be adversely affected by the presence of high ambient light. Shield the sensor area as needed (with a surgical towel or similar item).
The following factors will cause interference:
- High-frequency electrosurgical.
- Placement of a sensor on an extremity with a blood pressure cuff, arterial catheter, or intravascular line.
- The user has hypotension, severe vasoconstriction, severe anemia, or hypothermia.
- The user is in cardiac arrest or is in shock.
- Fingernail polish or false fingernails may cause inaccurate SpO2 readings.
WARNING: EXPLOSION HAZARD – Do not use the pulse oximeter in a flammable
atmosphere where concentrations of flammable anesthetics or other materials
may occur.
WARNING: Do not throw batteries in a fire; they may explode.
- Do not use the pulse oximeter in an MRI or CT environment.
CAUTION:
- Keep the operating environment free of dust, vibrations, corrosive or flammable materials, and extremes of temperature and humidity.
- Do not operate the unit if it is damp or wet from condensation or spills. Avoid using the equipment immediately after moving it from a cold environment to a warm, humid location.
WARNING : Do not attempt to recharge normal dry-cell batteries; they may leak, cause a fire, or even explode.
CAUTION
- Never use sharp or pointed objects to operate the front-panel switches.
- The battery must be removed from the battery compartment if the device will not be used for a long time.
- The device should only be used with the battery cover closed.
- When no longer usable, the battery should be disposed of properly according to local regulation.
Definitions and Symbols
Intended Use and Introduction
Intended Use
This product is solely for use with sporting and aviation activities. It is
not intended for medical use.
Brief Device Description
Sp02 (Functional oxygen saturation) is the amount of oxy-hemoglobin
expressed as a percentage of the Functioning Hemoglobin. Functioning
Hemoglobin is capable of carrying oxygen and includes oxygenated hemoglobin
(HbO2) and deoxygenated hemoglobin (Hb). PR(Pulse Rate), measured in beats per
minute (bpm), is the frequency of heart beats.
ThePulseOximeter , based on all digital technology, is intended for noninvasive spot-check measurement of functional oxygen saturation of arterial hemoglobin (SpO2). Advanced DSP algorithm can reduce the influence of motion artifact and improve measurement accuracy of low perfusion.
Contraindication
It is not for intensive care and person whose finger is injured.
Installation, Setup, and Operation
Description of the Front Pane
Display
After switch-on, the LED display shows:
Operation
Install the batteries. Install two AAA batteries in the correct direction
in the battery compartment and put the cover back on. Warning: Do not
attempt to recharge normal alkaline batteries; they may leak and may cause a
fire or even explode
Turn the Pulse Oximeter on
- Put one of finger into the rubber hole of the pulse oximeter (as much area as possible) with nail facing upward (as FIG.4), then releasing the clamp.
- Press the key, pulse oximeter will go into the working state.
- Keep the tested hand still during measurement
- If no finger is inserted, the pulse oximeter will automatically go into standby mode or go to sleep after 8 seconds.
Read the data from the display screen.
The LED display interface is shown below:
Note: When battery power is at the lowest level, the battery capacity indicates the symbol of C8:I on the display to remind users to replace the batteries
Turn Off the Pulse Oximeter
The pulse oximeter will turn off automatically after 16 seconds after removing the finger out of the device.
Maintenance
Cleaning
Switch “off” the power and take out the batteries before cleaning, Clean
exterior surface (screen included) of the unit with a dry and soft cloth. Use
isopropyl alcohol 75% to clean the surface. Use a small amount of alcohol on a
dry fabric to avoid alcohol from permeating into the device.
Disinfecting
Disinfect the machine after using if multiple users are using the machine.
Use isopropyl alcohol 75% to clean the surface in contact with the user.
CAUTION
- Don’t use strong solvent such as acetone.
- Never use an abrasive such as steel wool or metal polish.
- Do not allow any liquid into the product, and do not immerse any parts of the device into any liquids.
- Avoid pouring liquids on the device while cleaning.
- Don’t allow any cleaning solution to remain on the surface of the device.
Maintenance
- Replace the batteries promptly when battery indicator shows they are low.
- Clean the surface of the pulse oximeter before it is used.
- Remove the batteries inside the battery cassette if the pulse oximeter will not be used for a period of time.
- It is best to store the unit in a place where the ambient temperature remains between -4°F and 131°F.
- Regularly inspect the unit to make sure no obvious damage has occurred that would affect the safety and performance of the device.
- Do not use the unit near any flammable substance, in extreme temperatures, or in places with excessive humidity.
Troubleshooting
Problems | Possible Reason | Resolutions |
---|---|---|
Oxyhemoglobin or heart rate cannot be shown normally. | 1. Finger is not |
inserted deeply enough into the unit.
2. User perfusion is too low to be measured.
| 1. Try reinserting the finger.
2. If no result is achieved after several tries, and you can find no issue with the product, go to a hospital for an exact diagnosis.
Oxyhemoglobin or heart rate reading is unstable.| 1. Finger is not inserted deeply enough into the unit.
2. Finger is trembling or user is moving too much.
| 1. Try reinserting the finger.
2. Remain calm and move as little as possible.
The pulse oximeter doesn’t turn on and start working.| 1. Batteries may be missing or too low in power.
2. Batteries may be installed incorrectly.
3. The pulse oximeter may be damaged.
| 1. Replace the batteries.
2. Reinstall the batteries.
3. Contact the local customer service center.
The screen suddenly turns off.| 1. The product automatically goes into standby or sleep when no signal is detected longer than 8 seconds.
2. The batteries may be too low in power.
| 1. This is normal.
2. Replace the batteries.
Disposal To avoid contaminating or infecting users, the environment or, other equipment, make sure you disinfect or decontaminate the device appropriately before disposing of it in accordance with your country’s law for equipment containing electrical and electronic part
Specification
Physical Characteristics
- Dimensions: 2.25″ (L) x 1.2″ (W) x 1.2″ (D)
- Weight: approx: 2 oz. (including two AAA batteries)
Classification
- Anti-Electric Shock Type: Internally powered equipment
- Anti-Electric Shock Degree Type: BF equipment
- EMC Type: B class I
- Mode of Operation: Continuous operation
- Enclosure Degree of Ingress Protection: IP22
IP22 means the shell of this product can withstand the water dropping to the surface when the shell is angled 15 degrees from the horizontal surface.
Power
Internal | Two AAA 1.5v alkaline batteries |
---|---|
Power Consumption | Smaller than 30mA (normal) |
Environmental
Operating Temperature | 40°F to 100°F |
---|---|
Storage Temperature | -4°F to 131°F |
Relative Humidity | 15% to 85% non-condensing |
Electronics Parameters
Parameter | Value |
---|---|
Hemoglobin saturation Display |
35%-100%
Pulse Rate Display| 25 BPM-250 BPM
Resolution
| Hemoglobin Saturation|
1%
Pulse Rate| 1 BPM
Measure Accuracy
|
Hemoglobin Saturation
| 2% (80%-100%)
3% (70%-80%)
Unspecified (※70%)
Pulse rate| 2 BPM
Warranty
Your BodyMed” Fingertip Pulse Oximeter is warranted to be free from defects in
materials and workmanship occurring within one (1) year from date of purchase,
when used in strict accordance with the instructions provided with the
monitor. The sole remedy for a breach of this warranty is replacement of
defective materials or components. This warranty extends only to the original
purchase. The purchase receipt or other proof of date of original purchase is
required before full replacement will be provided.
Please contact BodyMed” at:
1-866-528-2152
BODYMED” MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ALL SUCH WARRANTIES BEING HEREBY EXPRESSLY EXCLUDED.
The warranty described above does not extend to the normal wear of the product and is void if the product housing has been removed or if the product fails to function properly as a result of an accident, misuse, abuse, neglect, mishandling, misapplication, defective batteries, faulty installation, set-up, adjustments, improper maintenance, alteration, maladjustment of controls, modification, power surges, commercial use of product, use of the product which differs from the suggested use set forth in the product instructions, service by anyone other than an authorized service center or acts beyond the control of the manufacturer.
BODYMED” SHALL NOT BE LIABLE FOR ANY INDIRECT, INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, WHETHER ARISING UNDER CONTRACT, TORT, STRICT LIABILITY, STATUTE OR OTHER FORM OF ACTION OR ANY DAMAGES IN EXCESS OF THE COST OF THE REPLACEMENT OF THE PRODUCT.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>