iS5 COMMUNICATIONS iSC2F Industrial Management Ethernet Switch User Manual
- June 10, 2024
- iS5 Communications
Table of Contents
iS5 COMMUNICATIONS iSC2F Industrial Management Ethernet Switch
COPYRIGHT NOTICE
© 2023 iS5 Communications Inc. All rights reserved.
No part of this publication may be reproduced in any form without the prior
written consent of iS5 Communications Inc. (iS5).
TRADEMARKS
iS5Com is a registered trademark of iS5. All other trademarks belong to their
respective owners.
REGULATORY COMPLIANCE STATEMENT
Product(s) associated with this publication complies/comply with all applicable regulations. For more details, refer to the Technical Specifications section.
WARRANTY
iS5 warrants that all products are free from defects in material and
workmanship for a specified warranty period from the invoice date (5 years for
most products). iS5 will repair or replace products found to be defective
within this warranty period including shipping costs. This warranty does not
cover product modifications or repairs done by persons other than iS5-approved
personnel, and this warranty does not apply to products that are misused,
abused, improperly installed, or damaged by accident.
Refer to the Technical Specifications section for the actual warranty
period(s) of the product(s) associated with this publication.
DISCLAIMER
Information in this publication is intended to be accurate. iS5 shall not be
responsible for its use or infringements on third-parties because of the use
of this publication. There may occasionally be unintentional errors on this
publication. iS5 reserves the right to revise the contents of this publication
without notice.
CONTACT INFORMATION
iS5 Communications Inc. 5895 Ambler Drive, Mississauga, ON, L4W 5B7
Tel : 1+ 905-670-0004
Website : www.iS5Com.com
Technical Support
E-mail: support@iS5Com.com
Sales Contact
E-mail: info@is5com.com
Alerts
- Equipment for use in locations where children are not likely to be present
- For equipment intended only for use in a restricted access area
- For installation by skilled person
- For protective earthing conductor
- For replaceable component or module
- For outdoor installations
Humidity and Dust Hazards
Do not store the switch in locations where it will be subject to excessive
dirt and dust and high humidity. Conformal coating is recommended for humid/
moist applications.
Caution: Laser
- This product contains a laser system and is classified as a CLASS 1 LASER PRODUCT. Use of controls and adjustments or performance od procedures other than those specified herein may result in hazardous radiation exposure
GETTING STARTED
Introduction
The iSC2F is a cost-effective single serial media converter solution for the
conversion between serial RS232/RS485/RS422 interfaces and optical fiber. The
iSC2F has been designed for power substation applications and rolling stock
applications and is fully compliant with the IEC 61850-3 and IEEE 1613
standards.
The iSC2F accepts a wide input voltage range from single input of 11-36VDC
(Opr), 24VDC (Nom); 36-75VDC (Opr), 48VDC (Nom); or single input 88-300VDC
(Opr), 100-240VDC (Nom); or 85-264VAC (Opr) 50/60Hz, 100-240VAC (Nom), which
makes it suitable for harsh operating environment. These features combined
with a wide operating temperature of -40°C to 85°C help protect mission-
critical applications from network interruptions or temporary malfunctions.
The iSC2F supports the following functions:
- Two-wire RS232 compliant (TX, RX)
- Two-wire RS485 half-duplex compliant (D+, D-)
- Four-wire RS485/422 full-duplex compliant (TX+, TX-, RX+, RX-)
- Switch selectable 120 terminations
- Up to 5 km multimode fiber
- Selectable Fiber Repeater Mode (fiber in -> fiber out)
- TX/RX LED indicators on RS232/485/422 Traffic
- Configurable RS485 half-duplex turn-around time
- 1200-115200 baud supported
The ISC2F is equipped to provide conversion from serial (RS232, RS485, or RS422) to fiber optics or between serial standards (RS232 to RS485 / RS422).
Serial to fiber optical conversion connections can be:
- Point-to-Point
- Fiber Repeater Mode
- Standard Serial Connection
By using the DIP switches, iSC2F can be used in the following operating modes.
Configuring the Device
The ISC2F can be configured using the Mode DIP switch located on the right
side off the enclosure. Use the DIP switch to change the operating mode of the
ISC2F.
The configuration settings are as follows:
Switch| ON| OFF|
---|---|---|---
1| RS232 to fiber| RS485/422 to fiber
2| RS232-to-RS485/422
conversion enabled
| RS232-to-RS485/422
conversion disabled
3| Full-duplex| Half-duplex (RS485 only)
4| 120 Ω terminations
enabled
| No 120Ω termination
5| Fiber repeater enabled| Fiber repeater disabled
6| 1200 – 2400 baud| n/a
7| 4800 – 9600 baud| n/a
8| 14400 – 19200 baud| n/a
9| 28800 – 38400 baud| n/a
10| 57600 – 115200
baud
| n/a
Serial-to-Fiber Conversion—Point-to-Point
- RS232 device
- iSC2F
- RS485 Device/ Network
Note that the distance between the two ISC2F devices should be less than 5 km (3.1 mi).
RS232 Device
Position | State | Notes |
---|---|---|
1 | ON | RS232 to fiber |
2 | OFF | RS232-to-RS485/422 conversion |
3 | ON/OFF | Full-duplex (485-4W or 485-2W) |
4 | OFF | No 120 W termination |
5 | OFF | Fiber repeater |
Note : Position 3 applies to RS485 only.
RS422/RS485 Device
Position | State | Notes |
---|---|---|
1 | OFF | RS232 to fiber |
2 | OFF | RS232-to-RS485/422 conversion |
3 | ON | Full-duplex |
4 | OFF | No 120 W termination |
5 | OFF | Fiber repeater |
In this mode, serial data is converted directly into light signal and transmitted over multi-mode fiber optics. The serial standard is selected by Position 1 of the DIP switches: OFF (default) is for RS485/RS422, and ON is for RS232. Position 2 should be OFF for serial to fiber conversion. Position 6-10 should be configured if RS485 communications are used, to have the appropriate turn-around timer shown below selected. Positions 6-10 do not impact communications in full-duplex mode.
Baud Rate (bps) | DIP6 | DIP7 | DIP8 | DIP9 | DIP10 |
---|---|---|---|---|---|
1200 – 2400 | ON | OFF | OFF | OFF | OFF |
4800 – 9600 | OFF | ON | OFF | OFF | OFF |
14400 – 19200 | OFF | OFF | ON | OFF | OFF |
28800 – 38400 | OFF | OFF | OFF | ON | OFF |
57600 – 115200 | OFF | OFF | OFF | OFF | ON |
Fiber Repeater Mode
When a distance that is more than 5 km (3.1 mi) has to be supported, iSC2F must be used in Fiber Repeater mode. This mode supports extended distance between serial devices.
- RS232 device
- iSC2F
- RS485 Device/ Network
Position | State | Notes |
---|---|---|
1 | OFF | RS232 to fiber |
2 | OFF | RS232-to-RS485/422 conversion |
3 | OFF | Full-duplex |
4 | OFF | No 120 Ohm termination |
5 | ON | Fiber repeater |
6 | OFF | 1200 – 2400 baud |
7 | OFF | 4800 – 9600 baud |
8 | OFF | 14400 – 19200 baud |
9 | OFF | 28800 – 38400 baud |
10 | OFF | 57600 – 115200 baud |
The repeat function will optically re-transmit any data received on the
optical receiver, in addition to any connected serial devices. As a result,
any data transmitted from the master, will be re-transmitted optically to the
slave. In this case, the distance between master and slave can be extended
over the 5 km (3.1 mi).
This topology can be used for RS232, RS485 or RS422. In all cases, all
repeater devices should have the repeat function—DIP position 5 ON.
Serial Standard Conversion
- RS232 device
- iSC2F
- RS485 Device/ Network
Position | State | Notes |
---|---|---|
1 | OFF | RS232 to fiber |
2 | ON | RS232-to-RS485/422 conversion |
3 | ON/OFF | Full-duplex |
4 | OFF | No 120 W termination |
5 | OFF | Fiber repeater |
6 | ON/OFF | 1200 – 2400 baud |
7 | ON/OFF | 4800 – 9600 baud |
8 | ON/OFF | 14400 – 19200 baud |
9 | ON/OFF | 28800 – 38400 baud |
10 | ON/OFF | 57600 – 115200 baud |
In this mode of operation, RS232 voltage levels are converted to the
appropriate RS485 or RS422 signaling levels depending on the DIP switch
configuration. In this mode of operation position 2 of the DIP switches must
be in the ON position when operation position of switch 1 is OFF.
Position 6 – 10 of the DIP switches must reflect the proper operating baud
rate.
NOTE
In this mode of operation, no isolation is provided between RS232 device and
the RS485/422
network– both devices share the same common terminal. It should be noted that
the common terminal on RS232 devices is connected to ground. In some instances
(i.e. when connecting to large RS485 networks), it may be preferential for the
user to leave the RS485/RS422 shield terminal unconnected to the ISC2F in this
mode.
Communication Ports
The iSC2F can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available in specification.
Fiber Optic Ports
Fiber optic ports are available with ST (Straight Tip) connectors. Make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link.
Laser Radiation – IEC 60825-1 Clause 7.2-7.7
Caution: Laser
This product contains a laser system and is classified as a CLASS 1 LASER PRODUCT. Use of controls and adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
General Fiber Optics Cables Handling Instruction
- Wear finger cots or gloves. Your hands may look clean, but dirt and oils on them can damage the fiber and contaminate connectors.
- Never use the fiber pigtail to pick up or support the weight of the device. Keep both the device and the optical connector together in your hand(s).
- The fiber is made of a very pure expensive glass. Treat it with the same care that would be used when handling expensive crystal glass.
- Do not allow kinks or knots to develop in the fiber. Do not pull on the fiber when kinks or knots are present. Pulling will only cause knots, kinks, and curls to tighten and exceed the minimum bend radius.
- Always use the correct tools for stripping and cleaving the fiber. It will save time and reduce breakage caused by scratches.
- Follow all ESD precautions.
Serial Terminal
The ISC2F is equipped with a seven-terminal Phoenix-style connector. This connector can accommodate one RS232 connection, and one RS485/422 connection. The following is the pin-out for the serial terminal:
Pin #| Signal|
---|---|---
1 (top)| RS232 RX
2| RS232 TX
3| Common
4| RS422 RX-
5| RS422 RX+
6| RS422 TX- / RS485 D-
7 (bottom)| RS422 TX+ / RS485 D+
HARDWARE OVERVIEW
Front Panel
The ISC2F features various ports, controls and indicator LEDs on the front
panel for configuring and troubleshooting the device.
Number | Description | Function |
---|---|---|
1 | Power Indicator LED | The power indicator LED illuminates when power |
is being supplied to the device.
2| Tx LED| Tx LED illuminates when traffic is transmitted to Serial
Interface.
3| RX LED| Rx LED illuminates when traffic is received from Serial
Interface.
4
|
Mode Selector Switch
| This switch sets the device in transparent, half- duplex (HDX), full-duplex (FDX) or reserved mode.
Power Supply Connections
The Phillips Screw Terminal Block, located on the bottom of the unit, has Phillips screws with compression plates, allowing either bare wire connections or crimped terminal lugs. The use of #6 size ring lugs is recommended to ensure secure and reliable connections under severe shock or vibration. The terminal block comes with a safety cover which must be removed before connecting any wires. This cover must be re-attached after wiring to ensure personnel safety.
The iSC2F supports a single power supply (PWR1) with 4 options:
- LV: Single Input 11-36VDC (Opr), 24VDC (Nom);
- MV: Single input 36-75VDC (Opr), 48VDC (Nom);
- HV: Single input 88-300VDC (Opr), 100-240VDC (Nom);
- HV: Single input 85-264VAC (Opr) 50/60Hz, 100-240VAC (Nom);
Terminal Block (for option 4)
Note:
Options 1,2, and 3 don’t include terminal blocks. The DV power connection
should be done based on the diagram of the supplied chassis.
- Always use Lexan cover over terminals protects from unintentional contact
- The input terminals are to be in a restricted access location and accessed only by skilled persons.
Terminal Block Safeguard
- This equipment is intended only for use in a restricted access area.
- Electrical hazard – above ES2 limits. To be accessible by Skilled Persons only
Power Supply Connection
- 100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be installed.
- Equipment must be installed according to the applicable country wiring codes.
- 110-370VDC rated equipment: A 370VDC appropriately rated circuit breaker must be installed.
- A circuit breaker is not required for DC power supply voltages of 9-48VDC.
- Equipment must be installed according to the applicable country wiring codes.
Chassis Ground Connection
The iSC2F chassis ground connection, located next to the terminal block, uses a #6-32 Screw. We recommend terminating the ground connection using a #6 ring lug, and a torque setting of 15 in.lbs (1.7Nm).
Reliable Earthing
The Earth ground connection must be verified by an electrical engineer or a service person skilled in electrical installation and grounding
Hardware Installation
The ISC2F is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a DIN rail.
DIN Rail Installation
For DIN rail installations, the ISC2F can be equipped with a DIN rail bracket pre-installed on the back of the chassis. The bracket allows the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
To mount the device to a DIN rail, perform the following:
- Align the slot in the bracket with the DIN rail.
- Pull the release on the bracket down and slide the device onto the DIN rail. If necessary, use a screw driver to unlock the release. Let go of the release to lock the device in position.
Dimensions
All dimensions are shown in inches.
SPECIFICATIONS
Model Number iSC2F
Physical Ports
10M Fiber port| 1
RS232/RS422/RS485| 1 (2 for RS232 to RS485 conversion)
Power
Input power
| Single input of 11-36VDC (Opr), 24VDC (Nom); 36-75VDC (Opr), 48VDC (Nom);
or single input 88-300VDC (Opr), 100-240VDC (Nom); or 85-264VAC (Opr) 50/60Hz,
100- 240VAC (Nom)
Power consumption (Typ.)| 5 Watts
Overload current
protection
| Present
Reverse polarity
protection
| Present on terminal block
Physical Characteristics
Enclosure| IP-40 Galvanized Steel
Dimension (W x D x H)| 76.2(W) x 92.8(D) x 148.3(H)mm (3.0 x 3.65 x
5.84 inches)
Weight (g)| ~1000 g
Environmental
Storage Temperature| -40 o C to +85 o C (-40 o
to 185 o F)
Operating Temperature| -40 o C to +85 o C (-40 o
to 185 o F)
Operating Humidity| 5% to 95% Non-condensing
Regulatory Approvals
EMI| FCC Part 15, CISPR (EN55022) class A, EN50155 (EN50121-3-2,
EN55011, EN50121-4)
EMS
| EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5
(Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
Shock| IEC60068-2- 27
Free Fall| IEC60068-2- 32
Vibration| IEC60068-2- 6
Safety| EN60950- 1
Warranty
Warranty| 5 Years
Documents / Resources
| iS5
COMMUNICATIONS iSC2F Industrial Management Ethernet
Switch
[pdf] User Manual
iSC2F Industrial Management Ethernet Switch, iSC2F, Industrial Management
Ethernet Switch, Management Ethernet Switch, Ethernet Switch, Switch
---|---
| iS5
Communications iSC2F Industrial Management Ethernet
Switch
[pdf] User Manual
iSC2F Industrial Management Ethernet Switch, iSC2F, Industrial Management
Ethernet Switch, Management Ethernet Switch, Ethernet Switch, Switch
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>