Anolis Lighting Divine 160 Multichip Optical System Delivers Superb Light Instruction Manual
- June 10, 2024
- Anolis Lighting
Table of Contents
Divine 160 Multichip Optical System Delivers Superb Light
Product Information: Divine 160
The Divine 160 is a lighting unit that requires installation by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. It falls under class one and must be grounded.
The unit has inlets for power and data from the bottom or side of the luminaire, with a junction box located on the bottom side of the luminaire. It requires a 5-cored cable Flamar Li9YC11Y for connection to mains and a DMX controller, with three colors serving for the power supply and two shielded cores intended for DMX connection. The unit has a control menu that can be set inside or outside the junction box.
The Divine 160 can be installed using a surface mount adaptor, a set of rubber feet, or a C-clamp adaptor. The unit also has various accessories available, including an optical demo set, half top hat, top hat, wire guard/anti-glare, and barndoor module.
Product Usage Instructions: Divine 160
- Install the Divine 160 with a qualified electrician in accordance with all national and local electrical and construction codes and regulations. Ensure that the unit falls under class one and is grounded.
- Choose the appropriate cable gland for bottom or side connection and install it accordingly.
- Strip the appropriate lengths for cable connections for power and data connections, with control menu inside or outside junction box.
- Connect the Divine 160 to mains and a DMX controller using a 5-cored cable Flamar Li9YC11Y. The three colors serve for the power supply and two shielded cores are intended for DMX connection.
- Set the control menu inside or outside the junction box.
- Close the junction box.
- Install cable gland individually using wrench size 24 for cable gland M20x1.5 or wrench size 16 for cable gland M12x1.5. Before applying the torque, ensure that the thread is clean and functional.
- Choose the appropriate installation option: surface mount adaptor, set of rubber feet, or C-clamp adaptor. Follow the corresponding installation instructions.
- Adjust the head position as needed.
INSTALLATION INSTRUCTIONS DIVINE 160
The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. This device falls under class one and must be grounded!
For bottom connection
STEP 1
CABLE GLAND
Inlets for power and data from bottom side of the luminaire.
For side connection
Inlets for power and data from side of the luminaire.
STEP 2
UNCOVER JUNCTION BOX
Uncover junction box located on the bottom side of luminaire.
STEP 3 CONNECTION
Strip these lenghts for cable connections
Power Connection | 9mm |
---|---|
Data Connection | 7mm |
Connection – colour coding
To connect the Divine 160 to mains and a DMX controller, use a 5-cored cable
Flamar Li9YC11Y. The 3 colors serve for the power supply and 2 shielded cores
are intended for DMX connection.
Power and Data Connection
WIRE | POWER CONNECTION | WIRE | DATA CONNECTION |
---|---|---|---|
Brown | L | White | Data – (D-) |
Blue | N | Red | Data + (D+) |
Yellow/Green | Ground | Shielding | Data Ground (0V) |
Wiring connection (control menu inside)Wiring connection (control menu outside)
STEP 4 CONTROL MENU
-
Control menu inside
Set control menu inside junction box.
Control menu outside -
Set control menu.
STEP 5
CLOSE JUNCTION BOX
Before applying the torque, make sure the thread is clean and functional.
STEP 5
CLOSE JUNCTION BOX
Before applying the torque, make sure the thread is clean and functional.
STEP 6
CABLE GLAND INSTALLATION
Use wrench size 24 for cable gland M20x1.5 Use wrench size 16 for cable gland
M12x1.5
Install Cable glands individually!
We recommend to apply an adequate layer of the paste LOCTITE 5331 on the
plastic holder of the cable gland before inserting in into the body of the
gland and an adequate layer of the paste LOCTITE 577 on the thread of the
gland body.
Failure to properly install cable glands will result in failure of the water
tight seal!
STEP 7.A
INSTALLATION WITH SURFACE MOUNT ADAPTOR
Mount the adaptor using 6 mounting screws.
Use fasteners that are appropriate for use with your mounting surface.
Drill holes to the surface according to holes spacing. Mount Divine via mounting holes on the surface.
STEP 7.B
INSTALLATION WITH SET OF RUBBER FEET
Mount pair of rubber feet using 4 screws.
STEP 7.C
INSTALLATION WITH C-CLAMP ADAPTOR
Mount the adaptor using 5 screws.
TYPE OF ACCESSORIES
STEP 8
INSTALLATION OF ACCESSORIES
Unscrew two screws and split accessory to two parts. Place each part onto the luminaire´s head and screw them together.
Secure accessory by 4 screws with spring washer at the back side of luminaire´s head.
STEP 9
HEAD POSITION ADJUSTMENT
Release locking screw on each sides. Angle fixture to desired position and tighten locking screw on each sides.
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com VERSION 1.0 / 05_2022
Read User Manual Online (PDF format)