NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual

June 10, 2024
NEPO

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User
Manual

DESCRIPTION OF UNIT AND PARTS

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - Description
of unit and parts

  1. control Buttons
  2. Air outlet and louvers
  3. LED Display
  4. Exhaust Connector
  5. Castor
  6. Handle
  7. universal plug fixing holes
  8. Wire winding pillar
  9. Filter
  10. Drain hole and cover
  11. Filter

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - Description
of unit and parts

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safotycf ethers are very important. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. We have provided many important safety messages in this manual and on tale appliance. Always read and follow all safely messages.

This is the safety alert symbols.

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - This is the
safety alert symbols

To reduce the risk of explosion, f ire, death, electric shock, scalding, or personal injury when using this appliance, please observe the following basic precautions:

INSTALLATION AND OPERATION

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - Installation
and Operation NEPO NPP-E514H 14,000 BTU Portable AC and Heater User
Manual - Installation and Operation

READ ALL INSTRUCTIONS BEFORE USE

ELECTRICAL SAFETY (High voltage appliance)
  • If the power cable is damaged, it must be replaced by the manufacturer or an authorized technical service center in order to avoid all risk.
    During the installing or moving the appliance, be careful not to pinch, crush , or damage the power cord.
    Do not damage, alter, excessively bend, twist, pull or heat the power cord.
    Do not modify or extend the power cor

  • Do not cover the power cord with a rug or carpeting.
    Do not rest hot or heavy objects on the appliance and power cable.

  • Always plug into a fixed 115V AC ground outlet.
    Push the power plug ail’ the way into the wall outlet so that it is not loose.
    Always grip the plug firmly and pull straight out from the outlet when taking it out.
    Never plug or unplug the appliance with wet hands.
    Never unplug the appliance by pulling on the power cord.
    Never use the appliance if the outlet is damaged or loose.

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - Always
plug

  • Do not use multiple-outlet power strip or extension cord with this appliance.
    Do not use an AC plug adapter with this appliance.
    Do not cut or remove the third (ground) prong from the power cord .

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - ELECTRICAL
SAFETY

• Always finish the test of LCDI plug before use air conditioner:

LCDI INTEGRATED CIRCUIT BREAKER

GROUNDING METHOD

Ensure proper ground exists before use.

  • Always unplug the unit from the outlet before cleaning or maintenance operations. Always unplug the unit if you will not use it for a long time.

INSTALLATION INSTRUCTIONS

SUGGESTED TOOLS FOR INSTALLATION
  • Screwdrivers (met1ium size)
  • Tape measure or ruler
  • Knife or scissors
  • Saw (In the event that the window kit needs to be cut down in size because the window is too narrow for direct installation)
SELECTION OF INSTALLATION LOCATION
  1. Place the unit near a window.
  2. For best performance, allow at least 20inch (51 cm) of air space on all sides of tl1e unit for good air circulation.
ATTACHING EXHAUST HOSE

Install the plastic hose with window bracket adapter and hose connector on bott1 sides. Ensure proper fit on both ends.
The supplied exl1aust hose can be extended to 58inch max.

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - ATTACHING
EXHAUST HOSE

Push the plastic hose into tl1e hose connector on !lie back of the unit. Keep gently and horizontal lo avoid getting stuck.

Note:
The length of the exhaust hose is specially designed for the unit. Do not replace or extend it with another hose as this could cause malfunction. Do not block airflow around the air conditioner. Tile exhaust hose should be free of any obstructions.
A bent hose will block exhaust air and cause the unit to malfunction or shut- off.NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - ATTACHING
EXHAUST HOSE

Windows kit installation

NOTE: Depending on the size of your window opening, use the main panel and one or both of the extension panels.
1. Open the window and place the main window panel into the window.
NOTE : The window assembly is designed to accommodate either a vertical slide or horizontal slide window.

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - WlNDOW KIT
lNSTALLATION

CONNECT HOSE TO WINDOW KIT

The air exhaust hose must be installed or removed from the portable airconditionerh in accordance with the way it is being used:

  1. Hold the main window panel so that the L-shaped edges of the panel are facing you.

  2. Align the exhaust nozzle with the slots in the opening, and then insert and slide the nozzle to access the hole from the the back of the main window panel.

  3. Turn the main window panel over, so that the nozzle is away from you. Insert a fiat screw through the hole to fasten the window panel to the adapter.

  4. Grasp both ends of the exhaust hose and gently pull to expand the hose.
    NOTE: Do not attach additional hoses to extend the length. This would decrease cooling efficiency and may damage the air conditioner.

  5. Using a counterclokwise motion, attach the open end of the exhaust hose to the exhaust nozzle.

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - Using a
counterclokwise motion

Connect Exhaust Hose to the Air Conditioner

IMPORTANT: When connecting the hose, the air conditioner must be close enough to the window that you will not dislodge the window seal plate. Once the hose is connected, move the air conditioner 20″ (51 cm) from the wall.

  1. Extend the flexible exhaust hose to reach out to the unit.
  2. Aim the opening of the hose to the air exhaust outlet and push it hard straight into the outlet until it clicks.

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - Connect
Exhaust Hose to the Afr Conditioner

OPERATION

INSERTING BATTERIES IN THE REMOTE
  1. Press and glide the battery cover on the rear of the remote, remove the cover.
  2. Insert two new R03 ‘ AAA” 1.5V batteries into the battery compartment Make sure the polarity is correct.
  3. Battery is not included in t!1e package because of transportation safety.

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - INSERTING
BATTERIES IN THE REMOTE

NOTE:

  • Do not mix old and new /1atteries. Do not mix alkaline. sianclard (carbon-zinc) or rechargeable batteries.
  • If the remote control is not be used for a certain length of time, remove tile batteries (Battens may explode or leak).
  • If the remote control unit is replaced or discarded. the batteries must be removed and of in accordance with current legislation as they am harmful to the environment.
CONTROL PANEL AND LED DISPLAY

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - CONTROL PANEL
AND LED DISPLAY

A. Timer Button
Program a time from ( 1-hour to 24-hours) for the air conditioner to turn Off or On. When a Time Delay is programmed, the Timer indicator light will illuminate.

While the air conditioner is operating:

  1. Press the Timer button.
  2. Press the Up/Down arrow buttons to select the number of hours you want the air conditioner to continue to operate before turning Off.
    NOTE: Wait approximately 5 seconds for the Turn-Off time to be saved.

While the air conditioner is off:

  1. Press the Timer button.
  2. Press the Up/Down arrow buttons to select the number of hours you want the air conditioner to remain off before turning On.

NOTE: Wait approximately 5 seconds for the Turn-On time to be saved.
To cancel the timer:
• Press the Timer button once, the hours remaining will flash, press the timer button again and the timer will be canceled.
B. Fan Speed Button
The fan speed can be adjusted from Low speed to High speed when the air conditioner is either in Cool or Fan mode.
NOTE: The fan speed cannot be adjusted when the unit is in DEHUM mode.
• Press the Fan Speed button to toggle among the two speeds. The corresponding fan speed indicator will illuminate.
c. Up and Down Arrow Buttons
Adjusts the Temperature or Hours In Time Delay.

To Set the Temperature:
The temperature can be set between 62°F and 86° F (17°C and 30° C) when the air conditioner is in Cool mode.

  1. Press the Mode button until the Cool mode is selected.
  2. Press the Up Arrow or Down Arrow buttons to select the Temperature.
    NOTE: The temperature cannot be set when the air conditioner is in either Fan or Dry mode.

D. Mode Button
Press the Mode button to toggle among the operating options. The corresponding indicator will illuminate:
Cool – Coots the room to the set temperature
Heat (on some models) – Heats the room to the set temperature
Degum – Reduces the humidity in the room
Fan – Circulates the air in the room without cooling
E POWER BUTTON
Turns ON/OFF power to the air conditioner.
NOTE: Turning off power by pressing the Power button does NOT disconnect the appliance from the power supply.
•Press the Power button. The Power indicator will illuminate.
REMOTE CONTROL
1. Insert the two batteries (provided).
2. Aim the remote control at the signal receiver on the control panel to operate the air conditioner. A. Sleep Button
Increases the set temperature by 2°F (1°C) after 2-hours, and then increases the temperature by an additional 2°F (1°C) after another 2-hours.
NOTE: The fan will operate at Low speed and cannot be adjusted while in Sleep mode. Press the Sleep button to enter Sleep mode. The Sleep indicator will illuminate.

To Cancel Sleep Mode:
• Press the Sleep button or the Mode button !Cool, Fan or Dry) on the remote control.

WATER DRAINAGE

This portable air conditioner has a self-evaporative system. The condensed water will be recycled to the working compressor and evaporator. most of the water will be evaporated. This work procedure can not only improve cooling efficiency but also save energy for all customers.
Since most of the condensed water will be used to aid the compressor, there is no need of drain hose in general using environment.

If you use the portableoir conditioner for cooling or dehumidifying in a high humidity situc1tion (Relc1tive humidity >85%. like New Orleans, Louisiana, Jacksonville, Florida, Houston), the collected excess water will need to be drained through a drain plug in the bottom of the unit. With o full reservoir, the compressor will stop working.

Manual Drainage

  1. Unscrew the water stopper and unplug the rubber plug
  2. Put a tray below the water outlet at the back of the unit.

Continuous Drainage

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - Continuous
Drainage

  1. Unscrew the walker stopper and unplug the rubber plug

  2. Connect the drainage pipe to the walker container or drainage ditch to outdoor.
    The drainage pipe is purchased by users , pipe diameter is 13mm.

  3. This unit can be drained water from upper drain port and lower drain port.

PROTECTION FUNCTION OF PORTABLE AIR CONDITIONER
  1. Frost Protection Function:
    In a cold environment, if t!1e temperature of the EVA pipe sensor is too low. the machine will automatically enter protection status; if the temperature of the EVA pipe sensor rises to a certain temper turn ( 8 ‘ C), it can automatically revert to normal operation .

  2. Overflow Protection Function:
    When water in the water pan exceeds the warning level , the machine will automatically sound an alarm and stop working, and the W.F indicator will flash . At his time. you need to drain the water After the water is emptied, tl1e unit will work normal again.

  3. Protection Function of the Compressor:
    To increase the service life of the compressor, it has a 3-minute delay booting protection function after the compressor is turned off.

C.ARE AND CLEANING

Before cleaning or maintenance, turn the appliance off by pressing the button @ on the control panel or button@ on the remote control. Wait for 5-1 0minutes then unplug from the electrical outlet.

CLEANING THE CASE

You should clean the appliance with a slightly damp cloth then dry with a c/ry c/0/ll.

  • Never wash the air conditioner with water. It could l,e dangerous because of short circuit or fire.
  • Never use petrol, alcot1ol or solvents to clean tr1e appliance.
  • Never spray insecticide liquids or similar.
CLEANING THE FILTER

If the air filter is clogged with dust. the effectiveness of !he air conditioning will be reduced. To keep your air conditioner working efficiently, you should clean the evaporator filter every two weeks of operation.

  1. Unplug or disconnect power.

  2. Pull on the tabs to slide out the filters from the back of the air conditioner.
    NOTE: The secondary filters are accessible once the main filters are removed.

  3. Wash or vacuum the dust from the air filters.
    NOTE: If washed. gently shake the filter to remove the excess water and dust particles trapped in the filter.

  4. Reinstall the filters.

  5. Plug in or reconnect power.

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual - CLEANING THE
FILTER

START – END OF SEASON OPERATIONS

END OF SEASON OPERATIONS

  1. Remove the cap, run off all water left into the basin. When all the water has been drained, put Use cap back in place.
  2. Clean the filter and dry thoroughly before putting back.
  3. Remove the batteries from the remote.
  4. Store the unit in a cool, dry room, away from direct sunlight, extreme temperatures. and excessive dust. Keep it out of the reach of children .

START OF NEW SEASON CHECKS

  1. Make sure the power cable and plug are undamaged.
  2. Follow the installation instructions precisely, install the unit again.
  3. Place new batteri1Js into remote.

TROUBLESHOOTING

BEFORE YOU ASK FOR SERVICE
  • Check to make sure that the air conditioner is plugged in securely. lf it is not, remove the plug from the outlet, wait 10 seconds and plug it in again firmly.
  • Check the blown circuit fuse or the tripped main circuit breaker. If they work pro pearly, test the outlet with another appliance.

Troubleshoot your problem by using the chart below. This list includes common occurrences Uma am not the result of a defect in factory workmanship or materials. If the air conditioner still does not work properly. contact the customer service center. Customers must never troubleshoot internal components.

NEPO NPP-E514H 14,000 BTU Portable AC and Heater User Manual -
TROUBLESHOOTING

WARRANTY

PORTABLE AIR CONDITIONER LIMITED WARRANTY

Any repair. replacement, or warranty service, and all questions about this product should be directed to customer service center.

Tile warranty commences the day the product is purchased and covers up to a period of 1 year (12 months) for parts (manufacturing defects only).

Exclusions: This warranty does not apply to the below:

  • If the appearance or exterior of the product has been damaged or defaced, altered or modified in design or construction.
  • If there is damaged due to power line surge. user damage to the AC power cord or connection to an improper voltage source.
  • If the damage is due to general misuse, accidents.
  • Damages caused by unauthorized repair and using of non-genuine parts.
  • On products that have been purchased as refurbished, like new, second-hand.
  • Unit used in a commercial or rental setting.
  • Damages caused by improper installations.

Email: [email protected]; [email protected]
Website: www.nepousa.com; www.airemaxusa.com

All the technical and specific parameters, please refer to product nameplate.
Due to continuous improvement, we reserve the right to change some design without timely notice.

Electrician products should be properly disposed.
Please recycle wt1ern facilitiflS exist.
Ct1eck with your local authority or retailer for recycling.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NEPO User Manuals

Related Manuals