PCE Instruments PCE-DFG N series PC Software User Manual
- June 10, 2024
- PCE Instruments
Table of Contents
- PCE Instruments PCE-DFG N series PC Software
- Product Information
- Product Usage Instructions
- Requirements
- Installation
- Screen description
- Meaning of the individual icons on the tool bar
- Preparing the measurement
- Make a measurement
- After the measurement – evaluation
- Alerts
- Contact
- Disposal
- PCE Instruments contact information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PCE Instruments PCE-DFG N series PC Software
Product Information
The PCE-DFG N series / PCE-DFG NF series is a PC software designed to establish a connection with the PCE-DFG N/NF force gauge and perform force measurements. It allows the user to start and stop a measurement, load and save measurement series, remove and import measurement series from the software, and export measurement data. It also has features such as zooming and restoring the original graph, changing the background and representation of the graphic, and making zero point adjustment on PCE-DFG N/NF.
Product Usage Instructions
- Install the PC software by executing Setup PCE-DFG N/NF.exe and following the instructions of the setup.
- Establish a connection with the PCE-DFG N/NF by clicking on the “Establish connection with the PCE-DFG N/NF” icon on the tool bar.
- Select unit of measurement and sampling speed via the Settings window for dynamic device data which is shown when you click on the relevant icon (Show settings window for dynamic device data) in the “Settings group”.
- Start the measurement using one of the three available methods: Start Trigger, Continuous, or Single.
- After the measurement, analyze and evaluate the results using the numerical display or graphical representation. The original graph can be restored by clicking on the “Restore original graphic” icon.
- Other features such as zooming, moving the enlarged graph, changing the background and representation of the graphic, and making zero point adjustment on PCE-DFG N/NF can be accessed via the corresponding icons on the tool bar.
- To save or load measurement series, use the “Load series of measurements from a file” and “Save series of measurements in a file” icons respectively.
- To remove or import measurement series from the software, use the “Remove series of measurements from the software” and “Import series of measurements from the PCE-DFG N/NF” icons respectively.
- To export measurement data, use the “Export measurement data” icon.
User manuals in various languages
product search on: www.pce-instruments.com
Requirements
- A PC with Windows operating system: Windows XP SP3 or above, with connected mouse, keyboard, screen and free USB interface (2.0 or higher)
- Installed .NET framework 4.0
- Minimum resolution of 800 x 600
- 4 GB RAM recommended
- Graphic card
Installation
Execute “Setup PCE-DFG N/NF.exe” and follow the instructions of the setup.
Screen description
The main screen consists of several sections:
Below the title bar, there is a tool bar with icons that can be selected by a
mouse click. These icons are grouped according to their functions.
Below this bar, you can find an area where the measuring points are displayed
graphically (“Graphical evaluation”).
To the left of the graphic, all series of measurements that can currently be
loaded into the software are listed.
The next section below the graphic shows a chart with the measuring points
determined on the right and an area with statistical data on the left-hand
side.
The lower edge of the main window shows two status bars containing important
information, directly above each other.
The lower bar shows the statistical settings of the program that can be
defined in the settings screen.
The upper status bar shows the dynamic settings or data of the PCE-DFG N/NF
which are directly taken from the connected device. These include the serial
number of the device, the selected unit, the sampling speed and – relevant if
pressure unit has been selected – the reference surface set in the device.
Meaning of the individual icons on the tool bar
Icon | Description |
---|---|
Establish connection with the PCE-DFG N/NF | |
Disconnect from the PCE-DFG N/NF | |
Start measurement | |
Stop measurement | |
Load series of measurements from a file | |
Save series of measurements in a file | |
Remove series of measurements from the software | |
Import series of measurements from the PCE-DFG N/NF | |
Export measurement data | |
Enlarge (“zoom“) graphics area or move enlarged graphic | |
Restore original graphic | |
Change background and representation of the graphic | |
Print currently displayed graphic | |
Make zero point adjustment on PCE-DFG N/NF | |
Show settings window for static device data | |
Show settings window for dynamic device data | |
Select a language supported by the system | |
Show information window | |
Close program |
Preparing the measurement
Introductory information
The language selected by the user when installing the software is also offered
by the software as the standard language.
If you want to use a language different from the one selected when installing
the software, you can select it via the relevant icon (“selection of a
language supported by the system”) on the tool bar.
Before the PCE-DFG N/NF works in combination with the software, you must set
the assigned COM port as well as the baud rate in the device as well as in the
software. This has to be done only once.
Note:
It is important that the baud rate is the same in the PCE-DFG N/NF and in the
software. The COM port and the baud rate for the software can be set in the
Settings window for static device data.
In addition to the connection data, further settings like the date and time format and the number of decimal places shown can be set in this window.
Establish connection to the PCE-DFG N/NF
The connection to the PCE-DFG N/NF can be established by clicking on the
relevant icon („Connect with the PCE-DFG N/NF“).
Select unit of measurement and sampling speed
After successful connection to the PCE-DFG N/NF, you can now set the unit and
the sampling speed for future force measurements.
You can do this via the Settings window for dynamic device data which is shown
when you click on the relevant icon (“Show settings window for dynamic device
data“) in the „Settings“ group.
Note:
This window can only be shown if a connection to the PCE-DFG N/NF is active.
One pressure unit and three force units are available:
“pascal” (pressure unit), “newton”, “pounds” and “kilograms”.
Depending on the version, the following three picklists will be available:
“Pa”, “mN”, “mlb”, “g”(pascal, millinewton, millipound, gram)
or
“kPa”, “N”, “lb”, “kg”(kilopascal, newton, pound, kilogram)
or
“MPa”, “kN”, “klb”, “t”(megapascal, kilonewton, kilopound, ton)
The picklist for the sampling speed depends on the baud rate: the higher the
baud rate selected, the higher the sampling speed can be.
High sampling speeds are superfluous when the baud rate is too low as the many
values measured cannot be transferred, which has a negative effect on the
speed of communication to the PCE-DFG N/NF.
Note:
If at least one of the two settings has been changed (unit or sampling speed),
the setting of the PCE-DFG N/NF will be changed via the software. This can
cause short interruptions of the communication. However, the communication
will recover after a short time.
Make a measurement
When there is an active connection to the PCE-DFG N/NF, a new measurement can
be started.
You can make a zero point adjustment by clicking on the relevant icon (“Carry
out zero point adjustment on the PCE-DFG N/NF“).
After clicking on the relevant icon (“Start measurement“) in the tool bar, a
name for the series of measurements must be specified first.
When this has been done, a new dialog will appear. This dialog can be used to set further options relevant for the measurement to be made.
Duration of measurement
A measurement always takes the time previously set. The duration can be
entered in minutes or seconds.
The selected duration of a series of measurements must be at least 5 seconds.
The maximum possible duration is determined dynamically by the selected
sampling rate so that the overall number of measured values does not exceed
the maximum number of 1500000. The possible duration of measurement is limited
to a maximum of 120 minutes.
If you set a duration outside that range, the start of the measurement will be
disabled.
(“Please correct your entries.“)
Note:
Of course, an ongoing measurement can always be stopped manually. To stop the
measurement, click on the icon on the tool bar (“Stop measurement”).
Start trigger
The measurement can be started in three different ways:
-
“Immediately”
The measurement will start immediately after the window has been closed by clicking on “Apply“. -
“Change of value”
The measurement (and thus the lapse of time) will not start before the measurement value changes. -
“Threshold value”
In an additional box, you can enter a value which is then used as a reference value, in combination with the previously set unit. The measurement will start when this value is measured by the connected sensor of the PCE-DFG N/NF.
Alarm monitoring
You can set an upper limit and a lower limit for the measurement. When these
are exceeded / fallen below, a “silent alarm” will be triggered. This means
that the alarm is recorded but does not cause early termination of the
measurement.
If alarms occur during a measurement, these can be listed after completion of
the measurement. More information can be found under “Alarms“.
You have the following options:
“deactivated”:
No monitoring is active.
“fracture”:
Monitoring for material overload
Here, you must define an upper limit and a stage value in per cent. If the
upper limit is reached or exceeded during a measurement, this will be recorded
as an alarm. If from this time on the measured value drops to or below the
percentage set as the stage value, an alarm will be recorded every time this
occurs.
“within” / “beyond”:
For these two types of monitoring, an upper and a lower limit must be defined.
Depending on the selected type of alarm, an alarm will be triggered when the
measured value is „within“ or „beyond“ the selected range.
Graphical representation
Here, you can choose whether you want the graphic to be shown during or after
the measurement.
Make a measurement
Ongoing measurement
During an ongoing measurement, the current measurement value will be shown in
the lower left area (“Results“) of the display in large letters.
Moreover, in a small area above the status bars, a green level display can be
found.
Note:
As very high sampling rates can mean huge amounts of readings, not all
readings are displayed during a measurement dynamically. This applies to
graphics as well as to charts.
The actual number of readings will only be displayed when the measurement is
completed. This becomes apparent when the graphic or chart changes directly
after completion of a measurement.
The actual number of readings shown during a measurement depends directly on
the sampling speed selected:
Sampling speed | No. of readings in the preview |
---|---|
6 | Every reading |
12 | Every reading |
25 | Every reading |
50 | One in 3 readings |
100 | One in 6 readings |
200 | One in 12 readings |
400 | One in 25 readings |
800 | One in 50 readings |
After the measurement – evaluation
After completion of a measurement, all recorded measurement data are available. There are various sections in the main window to view these data.
Numerical display
In the lower right area of the main window, all readings are shown in a chart.
The individual readings are listed as: date, time, duration and reading in
numerical terms incl. unit.
The chart can be sorted by columns when you click on the header of the
respective column (“Date”, “Time”, “Duration [s]”, “Measurement value […]”).
Statistical data (“Results”)
In this area, the following data are shown in numerical terms: start date of the measurement, start and end time, duration of the measurement in seconds, number of recorded readings, minimum and maximum value, average of all readings.
Graphical evaluation
In the graphical evaluation area, the selected unit (force or pressure) is shown on the y axis and the time lapse is shown on the x axis. When moving the cursor over a dot on the displayed line, a small information box will appear after a short time, showing the data (time and unit) of the currently selected measurement value. This value can be selected from the chart by double- clicking on it.
The displayed graphic can also be shown in enlarged form in any other area.
To change this, the relevant icon in the tool bar (“Enlarge / zoom graphic
area or move enlarged graphic“) must be a magnifier.
When you press and hold the mouse key, you can draw a rectangle over the
graphic area. When you release the mouse key, the selected area will appear as
a new graphic.
When you have zoomed / enlarged at least once, zoom mode can be changed into
move mode by clicking on the icon (“Enlarge / zoom graphic area or move
enlarged graphic“) with the magnifier.
In this mode, the magnifier icon turns into a hand icon.
By moving the mouse over the graphic area and then pressing and holding the
left mouse key, the displayed segment can be moved.
When you click on the hand icon again, zoom mode will be re-activated. The
icon will turn into a magnifier again.
The original graphic can be restored at any time by clicking on the icon
(“Restore original graphic“) next to the magnifier / hand icon.
The icon to the right (“Change background and graphical representation“) can
be used to change the background of the graphic and the way it is displayed.
You can change this by clicking on the icon:
A single click will change the background to have more lines and the graphic
to have some additional dots. Another click on the icon will change back to
standard view.
The currently displayed graphic can be printed.
You can open the “Print“ window by clicking on the relevant icon (“Print
currently visible graphic”).
Load and save series of measurements
Via the relevant icon in the tool bar (“Load series of measurements from a
file” or “Save series of measurements in a file”), you can load and save a
series of measurements.
Export measurement results
A series of measurements cam be exported. Via the corresponding icon in the
tool bar (“Export measurement data”), the complete data content from a series
of measurements can be exported in csv format, separated by a semicolon.
Note:
If the number of lines exceeds the limit of 1048576 (220), they will
automatically be divided into several export files as some spreadsheet
programs have their limitations.
Import series of measurements from the device
By clicking on the relevant button, all series of measurements saved to the
meter can be imported from the meter into the software.
This can take a few minutes, depending on the number and the size of the
series of measurements as well as on the selected transmission rate.
The data will first be read completely before they are imported.
After successful transmission, each saved series of measurements will be
listed at the left-hand edge of the main window. A series of measurements can
be displayed in the software by left-clicking it.
It is recommended to save the recently imported series of measurements in
order to avoid losing them.
Note:
Only the newer versions of the meter are able to interpret the measurement
series to be imported. If the data are not compatible, for instance because
you have an older version of the meter, an error message will pop up.
Note:
The two-digit number within square brackets at the end of the message is a
code for more information on the reason of the error:
- [01]: No header data found for the saved series of measurements.
- [02]: No end marker found in the saved series of measurements.
- [03]: The saved series of measurements do not contain any data.
- [04]: The version of the data is not correct.
Alerts
If the pre-set values have been exceeded or fallen below during a measurement,
the status bar for dynamic data will indicate this after the measurement.
If alerts have occurred, just click on the box in the status bar to see some
more information on these alerts.
In the “alert overview“, all alerts occurred are listed in a chart.
This chart shows when the alert started, when it ended, what type of alert it
was and what reading triggered the alert.
Contact
You can read our Contact terms in our General Business Terms which you can find here: https://www.pce-instruments.com/english/terms.
Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the
European Parliament applies. Due to the contained pollutants, batteries must
not be disposed of as household waste. They must be given to collection points
designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back.
We either re-use them or give them to a recycling company which disposes of
the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in
accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
PCE Instruments contact information
Germany
PCE Deutschland GmbH
Im Langel 4
D-59872 Meschede
Deutschland
Tel.: +49 (0) 2903 976 99 0
Fax: +49 (0) 2903 976 99 29
info@pce-instruments.com
www.pce-instruments.com/deutsch
Germany
Produktions- und Entwicklungsgesellschaft mbH
Im Langel 26
D-59872 Meschede
Deutschland
Tel.: +49 (0) 2903 976 99 471
Fax: +49 (0) 2903 976 99 9971
info@pce-instruments.com
www.pce-instruments.com/deutsch
The Netherlands
PCE Brookhuis B.V.
Institutenweg 15
7521 PH Enschede
Nederland
Telefoon: +31 (0)53 737 01 92
Fax: +31 53 430 36 46
info@pcebenelux.nl
www.pce-instruments.com/dutch
United States of America
PCE Americas Inc.
711 Commerce Way suite 8 Jupiter / Palm Beach
33458 FL
USA
Tel: +1 561-320-9162
Fax: +1 561-320-9176
info@pce-americas.com
www.pce-instruments.com/us
France
PCE Instruments France EURL
23, rue de Strasbourg
67250 Soultz-Sous-Forets
France
Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18
info@pce-france.fr
www.pce-instruments.com/french
United Kingdom
PCE Instruments UK Ltd
Unit 11 Southpoint Business Park Ensign Way, Southampton Hampshire
United Kingdom, SO31 4RF
Tel: +44 (0) 2380 98703 0
Fax: +44 (0) 2380 98703 9
info@industrial-needs.com
www.pce-instruments.com/english
Chile
PCE Instruments Chile S.A.
RUT: 76.154.057-2
Calle Santos Dumont N° 738, Local 4 Comuna de Recoleta, Santiago
Tel. : +56 2 24053238
Fax: +56 2 2873 3777
info@pce-instruments.cl
www.pce-instruments.com/chile
Turkey
PCE Teknik Cihazları Ltd.Şti.
Halkalı Merkez Mah.
Pehlivan Sok. No.6/C
34303 Küçükçekmece – İstanbul Türkiye
Tel: 0212 471 11 47
Faks: 0212 705 53 93
info@pce-cihazlari.com.tr
www.pce-instruments.com/turkish
Spain
PCE Ibérica S.L.
Calle Mayor, 53
02500 Tobarra (Albacete)
España
Tel. : +34 967 543 548
Fax: +34 967 543 542
info@pce-iberica.es
www.pce-instruments.com/espanol
Italy
PCE Italia s.r.l.
Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano
Capannori (Lucca)
Italia
Telefono: +39 0583 975 114
Fax: +39 0583 974 824
info@pce-italia.it
www.pce-instruments.com/italiano
Hong Kong
PCE Instruments HK Ltd.
Unit J, 21/F., COS Centre
56 Tsun Yip Street
Kwun Tong
Kowloon, Hong Kong
Tel: +852-301-84912
jyi@pce-instruments.com
www.pce-instruments.cn
China
PCE (Beijing) Technology Co., Limited 1519 Room, 6 Building
Zhong Ang Times Plaza
No. 9 Mentougou Road, Tou Gou District 102300 Beijing
China
Tel: +86 (10) 8893 9660
info@pce-instruments.cn
www.pce-instruments.cn
References
- France.fr : Explore France and its wonders - Explore France
- iberica.es
- instruments.cn - The domain is available for purchase
- Computer Instruments | Home
- Discover Italy: Official Tourism Website - Italia.it
- N.E.E.D.S., (Nutritional Ecological Environmental Delivery System) specializes in providing products, information, and education
- PCE(北京)科技有é™å…¬å¸
- Improtek LTDA Distribuidor oficial de PCE Instruments | PCE Instruments
- PCE Teknik Cihazlar Paz. Tic. Ltd.Şti. | PCE Instruments
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>