Oase 5300 12 Volt Aquarius Eco Expert Pump Instruction Manual
- June 10, 2024
- Oase
Table of Contents
12 Volt Aquarius Eco Expert Pump
Instruction Manual
Aquarius Eco Expert
Original operating manual. This operating manual belongs with the unit and
must always be handed over together with the unit.
WARNING
- Disconnect all electrical units in the water from the power supply before reaching into the water. Otherwise there is a risk of injuries or death by electrocution.
- This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.
Questions, problems, missing parts?
Before returning the unit to your dealer, call us at
330-274-8317, Monday-Friday, or email
us at customerservice@atlantic-oase.com.
Safety information
Electrical connection
-
Special regulations apply to electrical installation in outdoor areas. Only allow a qualified electrician to perform the electrical installation.
– The qualified electrician has the required professional training, knowledge and skills to perform electrical installations in outdoor areas. The qualified electrician can detect potential risks and adheres to regional and national standards, regulations and directives.
– For your own safety, please consult a qualified electrician. -
Only connect the unit if the electrical data of the unit and the power supply match.
-
Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
-
Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
-
Protect open plugs and sockets from moisture.
Safe operation
- Do not use the unit, if electrical lines or the housing are damaged.
- Dispose of the unit if its power connection cable is damaged. The power connection cable cannot be replaced.
- The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pacemakers or implantable cardioverter defibrillators (ICDs). Always keep a distance of at least 8 in (0.2 m) between the implant and the magnet.
- Do not carry or pull the unit by its power cable.
- Route lines so that they are protected from damage and nobody can trip over them.
- Never make technical modifications to the unit.
- Only carry out work on the unit that is described in this manual.
- Only use original spare parts and accessories.
- Should problems occur, please contact the authorized customer service or OASE.
WARNING
Serious injury or death due to dangerous electrical voltage is possible with
an electrical device in water operated with a voltage U > 12 V AC or U > 30 V
DC.
- Disconnect all electrical devices in the water from the power supply before reaching into the water.
- Disconnect the device from the power supply before starting work on the unit.
WARNING
In the event of improper connection of the unit grounding, there is a risk of
electric shock. The unit must be grounded in order for the electrical current
to be dissipated via the grounding and to reduce the risk of electric shock in
the event of a malfunction or failure.
Instructions for grounding:
- The unit is equipped with a mains cable with grounding conductor and a plug with grounding pin. The plug must be plugged into a suitable socket, which is installed and grounded according to local regulations and ordinances and is protected by a FI protection switch (GFCI).
- Do not modify the plug. Have a suitable socket installed by an electrician if the plug does no fit into the socket.
- Contact an electrician if you have any doubts as to whether the appliance is properly grounded.
Intended use
Only use the product described in this manual as follows:
- For pumping normal pond water for filter systems, waterfall systems and water course sys- tems.
- For use in swimming ponds if the national regulations for installers are met.
- Only operate with the original switching power pack.
- In compliance with the technical specifications. (→ Technical data)
- Only subject to adherence to the permissible water quality values. (→ Permissible water values)
The following restrictions apply to the unit:
- Never use the unit with fluids other than water.
- Never run the unit without water.
- Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
- Do not connect to the domestic water supply.
- Do not use for commercial or industrial purposes.
- According to EMC (Electromagnetic Compatibility), this is a class A unit. The unit may cause malfunctions in living environments. It is the user’s responsibility to take suitable countermeasures.
Product description
Overview
-
Inlet (suction side)
• With filter cage (3) for submerged installation.
• With hose sleeve for connecting a hose for dry installation. -
Outlet (pressure side)
• Connection of the return flow to the pond (e.g. via a water course). -
Filter cage
-
Foot
• With mounting holes for firm installation on the ground, if required. -
Switching power pack with power cable
• Pump power supply
• For further information on the power pack, please refer to the separate operating manual. -
Switch for switching on/off the dynamic function
• Different conveyed volumes are pre-programmed in the pump controls for a dynamic fountain pattern with changing heights and diameters. When the dynamic function is switched on, the pump is continuously controlled using these values. -
Control system connection
• The control unit OASE Eco Control (accessories) is required to operate the pump.
• Alternatively, the pump can be integrated in an OASE Control network.
• For information on OASE Control, visit www.atlantic-oase.com. -
Hose sleeve ∅ 2 in (50 mm)
-
Hose sleeve ∅ 1½ in (38 mm)
-
Hose clips for fastening hoses on the hose sleeves.
-
Pipe sleeve ∅ 2 in (50 mm)
• For glued connection
Symbols on the unit
| The unit is dust-proof and water-tight down to 13.1 ft (4 m).
---|---
| Possible hazard for persons wearing pace makers.
| Only operate the unit with a safety transformer.
| Protect the unit from direct sunlight.
| Never dispose of the unit with normal household waste.
| Read the operating instructions.
Installation variants
-
Variant (a): Submerged pump installation
– The pump is positioned in the pond.
– Water flow via the filter cage. -
Variant (b): Dry pump installation
– The pump is installed without the filter cage outside of the pond but lower than the water level.
– Water flow via a satellite filter or skimmer.
Installation and connection
The pump can be installed submerged (in water) or dry (outside the water).
The use of the pump is only permitted subject to adherence to the specified
water quality.(→ Permissible water values)
- Pool water or salt water can impair the appearance of the unit. Such impairments are excluded from the warranty.
WARNING
The power supply carries dangerous electrical voltage and must not be
placed directly near water. Otherwise, there is a risk of serious injury or
death from electric shock.
- Install the power supply in a flood-protected position at a distance of at least 6.6 ft(2 m) from the water.
CAUTION Rotating components in the area of the intake connection and the
pressure connection. Reaching into the connections can lead to injuries.
Please note in particular: If a unit has stopped due to overload, it can start
up unexpectedly!
- Do not reach into the opening of the inlet connection or outlet connection while the power plug is connected.
- If the connections are freely accessible, e.g. if no hoses are connected, secure the connections with a finger guard. The finger guard is available as an accessory.
NOTE
If the pump is used for conveying excessively muddy water, the impeller unit
will be subject to increased wear and will require earlier replacement.
- Thoroughly clean the pond or pool before installing the pump.
- Install the pump at a raised level above the bottom of the pond. This reduces intake of muddy water.
Avoid direct sunlight when the components of the unit are not immersed, as this can cause them to heat up considerably. Use a protective cover if necessary.
Connecting the control system
The control unit OASE Eco Control (accessories) is required to operate the pump.
Alternatively, the pump can be integrated in an OASE Control network. For information on this topic, visit www.atlantic-oase.com.
For further information refer to the manual for the accessories.
Connecting and disconnecting the OASE Control plug connection
NOTE
The unit will be destroyed if water penetrates the plug connector.
- Connect the plug connector or place the protective cap on the plug connector.
– Ensure that the rubber seal is clean and fits precisely. If the rubber seal is damaged, replaceit.
– Secure the plug connector or protective cap with the two screws.
Submerged installation of the unit
Connection
Do not plug the power plug into the outlet yet!
Installation
- Position the pump horizontally on a firm, mud-free surface.
- Ensure that the pump is securely positioned.
- Only operate the pump when it is fully submerged.
A pull rope allows you to simply pull the pump out of the water.
− Pull the pull rope through the round openings on the bottom pan of the filter and make a knot.
Dry installation of the unit
Connection
Hoses or pipes can be connected at the inlet and outlet. Recommendation:
- Up to 16.5 ft length: Use hoses
- From 16.5 ft length: Use pipes.
Do not plug the power plug into the outlet yet!
Installation
- Position the pump horizontally on a firm, mud-free surface.
- Ensure that the pump is securely positioned.
To ensure stability, it is possible to screw the unit to a suitable base.
Connecting the switching power pack to the pump
NOTE
If water penetrates the plug connectors, this will destroy the pump.
-
Never undo the union nuts on the plug connectors.
-
The stud on the plug connector of the pump must engage with the plug connector of the switching power pack.
Do not plug the power plug into the outlet yet!
Once the plug connectors of the filter pump and switching power pack have been inserted and have engaged, they can only be disconnected by means of a screw driver.
Commissioning/start-up
NOTE
Never connect the pump to a dimmer. This will destroy the pump
NOTE
Never allow the pump to run dry. Otherwise the pump will be destroyed.
- Only operate the pump when it is submerged or flooded.
A brand-new pump will only reach its maximum capacity after several hours of
operation.
Switching ON/OFF
-
Switching on: Plug the power plug into the outlet.
– The unit switches on immediately. -
Switching off: Pull the power plug from the outlet.
Environmental Function Control (EFC)
When started up, the pump automatically performs a pre-programmed self-test
(Environmental Function Control (EFC)). The pump detects if it is running dry
/ blocked or submerged. The pump switches off automatically after approx. 60
seconds if it runs dry/is blocked. In the event of a malfunction, disconnect
the power supply and “flood the pump” or remove the obstacle. Afterwards, the
unit can be restarted.
Dynamic Function
- Slide the switch.
– ON: The function is activated.
– OFF: The function is deactivated.
NOTE
When Dynamic Function is activated, the EFC (Environmental Function Control)
function is restricted.
- The unit is not protected from running dry.
Maintenance and cleaning
CAUTION
Risk of injury due to unforeseeable start-up. Internal monitoring functions
can shut down the unit and reactivate it automatically.
- Disconnect the power plug before carrying out any work on the unit.
NOTE Do not use aggressive cleaning agents or chemical solutions. These agents can damage the housing, impair the function of the device and harm animals, plants and the environment.
- Clean the unit with clean water and a soft brush or sponge wherever possible. Remove stubborn dirt with the aid of the recommended cleaning agents.
Cleaning the unit
-
Clean the unit as required, but at least twice a year.
− When cleaning the pump, pay particular attention to the imp housing. -
Recommended cleaning agent for removing stubborn limescale de– Vinegar- and chlorine-free household cleaning agent.
-
After cleaning, thoroughly rinse all parts in clean water.
Pump disassembly/cleaning
- Pull the power plug and remove all connections.
- Dismantle the unit as shown in the figure.
Cleaning/replacing the impeller unit
NOTE
The impeller unit is guided in the motor block by a bearing. This bearing is a
wear part and should be changed at the same time as the impeller unit.
- Changing the bearing requires specialist knowledge and tools. Have the bearing changed by the OASE specialist dealer or send the pump to OASE.
NOTE
The impeller unit contains strong magnets that attract magnetic particles
(e.g. iron filings). Any remaining particles can cause irreparable damage to
the impeller unit and motor block.
- Carefully remove all adhering particles from the impeller unit before installation.
- Dismantle the pump as shown in the figure.
- Clean the components with a brush under clear water.
- Check all components for damage. Replace damaged or worn components.
- Reassemble the pump in reverse order.
Storage/overwintering
The unit is frost-proof down to temperatures of -4 °F (-20 °C). If you wish to
store the unit outside of the pond, clean it thoroughly with a soft brush and
water, check it for damage, then store it submerged or filled with water. Do
not immerse the power plug in water!
Troubleshooting
Malfunction | Cause | Remedy |
---|---|---|
The pump does not start | No power supply | Check power supply |
Supply lines kinked | Route the supply lines without kinks | |
Supply lines clogged | Check/clean supply lines | |
The impeller unit is blocked | Remove block, check impeller unit for ease of |
movement
Pump does not transport liquid Insufficient conveyed volume| Filter casing
clogged| Clean filter pans
Excessive loss in the supply lines| Reduce hose lengths to the necessary
minimum, remove unnecessary connec- tion parts
Impeller unit is running slug- gishly| Check impeller unit for ease of
movement
Pump switches off after a short running period| Water is heavily soiled| Clean
pump
The impeller unit is blocked| Remove block, check impeller unit for ease of
movement
Pump has run dry| Check/clean supply lines
Water temperature too high| Adhere to the maximum permissible water
temperature. (→ Technical data)
Technical data
Aquarius Eco Expert | 5300 / 12 V | ||
---|---|---|---|
Associated power pack | 250 VA / 12 V DC | ||
Connection voltage | V DC | 12 | |
Max. current consumption | A | 20 | |
Power consumption | W | 30 … 240 | |
Max. delivery rate | gph | 5283 | |
l/h | 20000 | ||
Max. pumping head | ft | 21.7 | |
m | 6.6 | ||
Protection type | IP68 | ||
Max. immersion depth | ft | 13.1 | |
m | 4 | ||
Suction side | Thread | G2 | |
Hose connection | in | 2 | |
mm | 50 | ||
Pressure side | Thread | G2 | |
Hose connection | in | 1½, 2 | |
mm | 38, 50 | ||
Max. grain size of coarse dirt | in | 0.16 | |
mm | 4 | ||
Filter inlet area | in² | 155 | |
cm² | 1000 | ||
Water temperature (sub- merged installation) | During operation | (→ |
Permissible water values)
Outside of operation| °F| -4 … +95
°C| -20 … +35
Ambient temperature (dry installation)| During operation and convection| °F|
+39 … +95
°C| +4 … +30
During operation and forced cool- ing| °F| +39 … +104
°C| +4 … +40
Dimensions| Length| in| 19.3
mm| 490
Width| in| 8.5
mm| 215
Height| in| 9.3
mm| 235
Length of connection cable| | ft| 26.2
m| 8
Weight| | lbs| 25.1
kg| 11.4
Permissible water values
Type | Fresh water | Pool water | Salt water | |
---|---|---|---|---|
pH value | 6.8 … 8.5 | 7.2 … 8.3 | 7.5 … 8.5 | |
Hardness | DH | 8 … 15 | 8 … 15 | 20 … 30 |
Free chlorine | mg/l | <0.3 | <0.6 | <0.3 |
Chloride content | mg/l | <250 | <250 | <22000 |
Salt content | % | <0.4 | <0.4 | <4 |
Overall dry residue | mg/l | <50 | <50 | <50 |
Temperature | °C | +4 … +35 | +4 … +30 | +4 … +28 |
Wear parts
- Impeller unit
- Bearing in the motor block
Disposal
NOTE
Do not dispose of this unit with domestic waste.
- Dispose of the unit by using the return system provided for this purpose.
- Should you have questions, please contact your local disposal company. They will give you instructions on how to dispose of your unit properly.
- Disable the unit by cutting off the cables.
Pos. | Aquarius Eco I Expert 5300 /12 V |
---|---|
1 | 40510 |
2 | L 40509 |
3 | 43864 |
4 | 70464 |
5 | 35359 |
6 | 42411 |
7 | 85273 |
8 | 48671 |
9 | 32972 |
10 | 88786 |
OASE North America Inc.
330-274-8317
www.atlantic-oase.com
References
Read User Manual Online (PDF format)