PCE Instruments PCE-THB 38 Air Humidity Meter User Manual

June 10, 2024
PCE Instruments

PCE-Instruments logo

PCE Instruments PCE-THB 38 Air Humidity Meter

PCE-Instruments PCE-THB-38-Air-Humidity-Meter-product

Product Information

The PCE-THB 38 is a manual air humidity meter manufactured by PCE Instruments. The device is designed to measure relative humidity, temperature, and atmospheric pressure. The device comes with a large, easy-to-read LCD display and is equipped with a data hold function, as well as a MAX/MIN function. The device is powered by two 1.5V AAA batteries.

Product Usage Instructions

  1. Remove the device from its packaging.
  2. Insert two 1.5V AAA batteries into the battery compartment.
  3. Press the power button to turn on the device.
  4. Select the measurement unit for temperature and atmospheric pressure using the UNIT button.
  5. Hold the device in the desired location and wait for the readings to stabilize.
  6. Read the temperature, relative humidity, and atmospheric pressure values from the device’s LCD display.
  7. To freeze the current readings, press the HOLD button.
  8. To view the maximum and minimum values recorded since turning on the device, press the MAX/MIN button.
  9. To turn off the device, press and hold the power button until the display turns off.

Note : Keep the device away from direct sunlight, water, and extreme temperatures. Clean the device with a soft cloth and avoid using chemicals or solvents that may damage the device.

FEATURES

  • Barometer, Humidity, Temperature meter, three in one, professional.
  • Barometer unit : hPa, mmHg, inHg.
  • Humidity with Dew point measurement
  • Temperature measurement with °C, °F unit.
  • Fast response time for humidity measurement.
  • Barometer measurement with high accuracy.
  • Two displays can select the four modes (functions) :
    • Humidity/Temp., Humidity/Dew point, Barometer/Temp., Barometer/Humidity.
  • Bright LCD display.
  • Microprocessor circuit ensures high accuracy and provides special functions and features.
  • Records Maximum and Minimum readings with recall.
  • Auto power off saves battery life.
  • Operates from DC l.SV ( UM4/AAA) x 4 PCs batteries.
  • Durable, long-lasting components, enclosed in strong, compact ABS-plastic housing

SPECIFICATIONS

General SpecificationPCE-Instruments PCE-THB-38-Air-Humidity-Meter-fig-
7 PCE-Instruments PCE-THB-38-Air-Humidity-
Meter-fig- 8

Electrical Specifications

Humidity/ Dew point

  • Humidity
    Range| 10 % to 95 % R.H.
    ---|---
    Resolution| 0.1 % R.H.
    Accuracy| ….:70% RH
     | ± (3% reading+ 1% RH).
     | < 70% RH – 3%  RH.
     | ± 3% RH.
  • Dew Point
     | Rane| 0.01   F.
    ---|---|---
    Resolution
    ‘| .j”| Rane
     | Resolution
    Remark:

:J. Dew Point display value is calculated from the

Humidity/Temp. measurement automatically.

n,e Dew Point accuracy is sun1 accuracy value of

Humidi __ & Tem erature measuren1ent..

Barometer

Measurement Range Resolution Accuracy __a ff > ading
hPa 10.0 to 999.9 0.1 ±  1.5 11Pa
1000 to 1100 1 ± 2 hPa
mmHg 7.5 to 825.0 0.1 ± 1.2 mmHg
inHg. 0.29 to 32.48 0.01 ± 0.05 inHg

TemperaturePCE-Instruments PCE-THB-38-Air-Humidity-Meter-fig-
10

Above specification tests under the environment RF Field Strength less than 3 V/M & frequency less than JO MHz only.

FRONT PANEL DESCRIPTION

PCE-Instruments PCE-THB-38-Air-Humidity-Meter-
fig- \(1\)

  1. Probe head
  2. Humidity/Temp. Sensor
  3. Power Button
  4. Hold Button, Unit Button
  5. REC Button, Mode Button
  6. LCD Display
  7. Battery Compartment/ Cover

MEASURING PROCEDURE

Mode {Function} selection

  1. Turn on the meter by pressing the ” Power Button 11 ( 3-3, Fig. 1 ) momentarily.
    Pressing the “Power Button ” ( 3-31 Rg. 1 ) momentarily again will turn off the meter.

  2. The meter can select 4 kinds of modes (functions):

    • Humidity /Temp.
    • Humidity/Dew point
    • Barometer /Temp.
    • Barometer/ Humidity

Pressing the ” Mode Button ” ( 3-5, Fig. 1 ) continuously ( not releasing the button ), the Display will show the following 4 kinds of screens in sequence :

Humidity /Temp. measurement

  • The upper Display shows the Humidity value
  • Lower Display show Temp. value

Humidity/ Dew point measurement

  • The upper Display shows the Humidity value
  • Lower Display shows Dew point Temp. value

Barometer /Temp. measurement

  • The upper Display show the Barometer value
  • Lower Display show Temp. value

Barometer/Humidity measurement

  • Upper Display show Barometer value
  • Lower Display show Humidity value

Until the Display show the desired model ( Function ), just release the ” Mode Button ” ( 3-5, Fig. 1 ), the meter will execute this function with default.

Unit selection

  1. The Unit selection only available for the upper Display Barometer mode.
  2. Turn on the meter by pressing the II Power Button 11 ( 3-3, Fig. 1 ) momentarily.
  3. Under the Barometer mode, pressing the ” Unit Button 11 ( 3-4, Fig. 1 ) continuously ( not release the button ), the upper Display will show the following indicator in sequence:

hPa, mmHg, inHg.

Until the Display shows the desired unit, just release the II Unit Button ” ( 3-4, Fig. 1 ), the meter will execute this measuring unit with default.

Temp. Unit { ‘C, “F} selection

  1. Power off the meter.
  2. Use one finger to press ( not release ) the ” Hold Button ” ( 3-4, Fig. 1 ), turn on the meter by pressing the ” Power Button ” ( 3-3, Fig. 1 ) momentarily, until the temperature unit ( 0c, °F ) of Display is lit, then release the II Hold Button II will change the Temp. unit from °C to °F or °F to °C with default.

Humidit:y measurement

  1. Turn on the meter by pressing the II Power Button ” ( 3-3, Fig. 1 ) momentarily.

  2. For the above 4-1 mode ( function ) selection, please set to :

  3. Humidity /Temp.
    ( Upper display show humidity value , lower display show Temp. value )

  4. Barometer/Humidity
    ( Upper display show Barometer value , lower display show humidity value )

Barometer measurement

  1. Turn on the meter by pressing the II Power Button” ( 3-3, Fig. 1 ) momentarily.

  2. For the above 4-1 mode ( function ) selection, please set to :

  3. Barometer /Temp.
    ( Upper display show Barometer value , lower display show Temp. value)

  4. Barometer/ Humidity
    ( Upper display show Barometer value , lower display show humidity value )

Dew point measurement

  1. Turn on the meter by pressing the II Power Button 11 ( 3-3, Fig. 1 ) momentarily.
  2. For the above 4-1 mode ( function ) selection, please set to :
  3. Humidity/ Dew point
    ( Upper display show humidity value, tower display show dew point value )

Data Hold

  • During the measurement, press the ” Hold Button ” ( 3-4, Fig. 1 ) momentarily to hold the measured value. The LCD will show a II HOLD” symbol.
  • Press the11 Hold Button ” once again to· release the data hold function.

Data Record { Max., Min. reading}

  1. The data record function records the maximum and minimum readings. Press the II REC Button ” ( 3-5, Fig. 1 ) momentarily to start the Data Record function, shows II REC ” on the display.

  2. With the II REC II symbol on the display.

  3. Press the II REC Button ” ( 3-5, Fig. 1 ) momentarily, the ” REC MAX 11 symbol along with the maximum value will appear on the display.

  4. Press the” REC Button 11 ( 3-5, Fig. 1 ) momentarily again, the II REC MIN II symbol along with the minimum value will appear on the display
    When the display shows “REC MAX II or “REC MIN ‘; press the” Hold Button ” ( 3-4, Ag. 1) momentarily will delete the max. ( min. ) value/ the display will show the “REC “only and execute the memory function continuously.

  5. To exit the memory record function, press the ” REC ” button for 2 seconds at least. The display will revert to the current reading, not show ” REC “

Auto power off management

  1. The instrument has a built-in “Auto Power Shut-off” function in order to prolong battery life. The meter will switch off automatically if none of the buttons are pressed within 10 min ..
  2. To deactivate this feature, Select the memory record function during measurement, by pressing the ” REC Button ” ( 3-5, Fig. 1 ).

BATTERY REPLACEMENT

  • Replace the batteries when of the LCD displays the low battery icon ” “, using 4 fresh 1.5 V ( UM4, AAA ) batteries.
  • To change the batteries, open ( rotate clockwise direction ) the ” Battery Cover ” ( 3-7, Fig. 1 ) .
  • Make sure the II Battery cover” (3-7, Flg 1) is secured after changing the batteries.

OPTIONAL CARRYING CASE

  • Soft carrying case with sash.
  • Size : 210 x 80 x 50 mm
  • Model : CA-52

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA
From outside US : +1
Tel: 561-320-9162
Fax: 561-320-9176
info@pce-americas.com
PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way
Hampshire / Southampton United Kingdom, SO31 4RF
From outside UK : +44
Tel : (0) 2380 98703 0
Fax : (0) 2380 98703 9
info@pce-instruments.com
www.pce-instruments.com/english
www.pce-instruments.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PCE Instruments User Manuals

Related Manuals