PREMIER MOUNTS AM175 Swingout Mount Installation Guide

June 4, 2024
PREMIER MOUNTS

AM175

Installation Guide

PREMIER MOUNTS AM175 Swingout Mount

PREMIER MOUNTS logo n1

Weight Limit

Maximum Flat Panel Weight: 175 lbs.

THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING AT LEAST FOUR TIMES THE WEIGHT OF THE FLAT PANEL. IF NOT, THE WALL STRUCTURE MUST BE REINFORCED.

Warning Statements

AM175 - Warning Symbol 1PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND COMPLETELY UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.

AM175 - Warning Symbol 2PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED, AS OUTLINED IN THESE INSTALLATION INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS PERSONAL INJURY, OR EVEN DEATH.

AM175 - Warning Symbol 2SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE PROPER SAFETY EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.

AM175 - Warning Symbol 2PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.

At least two qualified people should perform the assembly procedure. Personal injury and/or property damage can result from dropping or mishandling the flat panel.

If mounting to wall studs or ceiling studs, make sure that the mounting screws are anchored into the center of the wall studs or ceiling studs. Use of an edge-to-edge stud finder is recommended.

    It is recommended that a maximum of 5/8″ plaster board be used when mounting to wooden studs.

Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there are no electrical wires in wall. Cutting or drilling into an electrical line may cause serious personal injury.

Make sure there are no water or natural gas lines inside the wall where the mount is to be located. Cutting or drilling into a water or gas line may cause severe property damage or personal injury.

This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious personal injury.

Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of impact.

Included components

AM175 - components 1 x1 x1 Pair x8

Swingout Mount            Mounting Bracket           Universal Spacers

x4 x8 x4

Griplate™ Washer           5/16″ Flat Washer         5/16″ x 3″ Lag Bolt

x4                     x4 x4

M4 x 16mm                  M4 x 25mm                 M4 x 30mm

x4                     x4                       x4

M6 x 16mm                 M6 x 25mm                 M6 x 30mm

x4                     x4 x4

M8x 16mm                 M8 x 25mm                 M8 x 30mm

x4 x1 x4

Finned Anchor     Thread Depth Indicator (Supplied)    Extension Adapter

  x4            AM175 - components 20 x6

M8 Nylon Nut                      Channel Covers

Required for installation

Level

M6 or 1/4″ Wood Drill bit     3/8″ Masonry Drill bit

13mm or 1/2″ Socket

Introduction

AM175 - Introduction

Directional Mounting Arrow
The Directional Mounting Arrow stamped into the AM175 Mount indicates which edge is the top.

Mounting Safety

**** Two people are recommended for this step

[1]

AM175 - Wood Installation 1

Wood Installation

**** Minimum of 2 x 4 wood stud to be used

****You must secure the mount to two (2) wall studs with a minimum of four (4) lag bolts (2 lag bolts for each stud found).

[2]

AM175 - Wood Installation 2

****Two people are recommended for this step; one person to level the Mount and another person to mark the wall stud location.

  1. Place the mount against the wall in the desired viewing location.
  2. Adjust the mount to align the mount slots in the wall plate with the center of the wall studs.
  3. Level the mount.
  4. Use a pencil to mark the upper right mounting location along the center of the wall stud.

[3]

AM175 - Wood Installation 3

Drill a “pilot hole” in the center of the upper right mark using a 1/4″ drill bit and power drill.

**** Only use a 1/4″ drill bit when drilling pilot holes.

[4]

AM175 - Wood Installation 4

  1. Place the Mount against the wall and align it with the pilot hole.
  2. Insert one (1) 5/16″x 3 lag bolt and one (1) 5/16″ washer into the upper right pilot hole.
  3. Use a socket wrench and a 1/2″ socket to tighten the lag bolt.

**** Do not overtighten the lag bolt.

[5]

AM175 - Wood Installation 5

  1. Level the Mount.
  2. Use a pencil to mark the remaining three (3) mounting locations along the center of each wall stud.

[6]

AM175 - Wood Installation 6

****Two people are recommended for this step; one person to level the Mount and another person to drill the pilot holes.

Drill a “pilot hole” in the center of each of the marks with a power drill and a 1/4″ drill bit.

**** Only use 1/4″ drill bit when drilling the pilot holes.

[7]

AM175 - Wood Installation 7

  1. Insert one (1) 5/16″ x 3″ lag bolt and one (1) 5/16″ washer into each pilot holes.
  2. Tighten all lag bolts using a socket wrench and 1/2″ socket.

****Do not overtighten the lag bolts when attaching the mount to the wall. Improper installation may result in personal injury or property damage.

[8]

AM175 - Wood Installation 8

Concrete Installation

****Two people are recommended for this step: one person to level the mount and another person to mark the mounting locations.

[9]

AM175 - Wood Installation 9

Drill four (4) pilot holes of each mark using a drill and 3/8″ masonary drill bit. Drill 3 inches deep.

**** Only use a 3/8″ masonary drill bit when drilling pilot holes.

[10]

AM175 - Wood Installation 10b

Insert a Finned Anchor into each hole. Lightly tap each Finned Anchors into place with a hammer.

x4

Finned Anchor

[11]

AM175 - Wood Installation 11

Insert the lag bolts and washers into the Finned anchors.Tighten all lag bolts using a socket wrench and 1/2 socket.

**** Do not over tighten the lag bolts.

x4                    x4

5/16″ Flat Washer          5/16″ x 3″ Lag Bolt

Selecting the Mounting Hardware

[12]

AM175 - Wood Installation 12a

AM175 - Wood Installation 12b AM175 - Wood
Installation 12c

  1. Insert a small straw or toothpick into the threaded inserts found on the back of the flat panel.
  2. Use a pencil to mark the depth of the threaded insert on the small straw or toothpick.
  3. Mark the straw or toothpick 1/8″ above the depth of the threaded insert, as shown in Figure 1.
  4. Insert the small straw or toothpick into the remaining threaded inserts to compare and verify their depth using the straw or toothpick’s 1/8″ allowance mark.
  5. Locate the correct diameter screw for the threaded insert.

****If the screw you selected is longer than the 1/8″ allowance mark on the small straw or toothpick, as shown in Figure 2 and Figure 3, do not use this screw. The screw length must not bypass the mark.

  1. Test each size of the screws provided.

****The correct screws should thread easily into the mounting point and not pull out when tension is applied.

Universal Spacer Installation (Optional)

[13]

AM175 - Wood Installation 13a

  1. Mounting Screw
  2. Universal Washer
  3. Mounting Bracket
  4. Flat Panel
  5. Universal Spacer
  6. Mount Point

Premier Mounts’ Universal Spacers allow you to attach the mounting bracket to flat-panels which have recessed or uneven mount points. Each Universal Spacer adds 1/4″ to the distance between the mounting bracket and your flatpanel.

****The Universal Spacers must be stacked and oriented as shown.

****The Universal Spacers must only be installed between the mounting bracket and your flat-panel.

If your flat panel has uneven mounting points, or recessed mounting points, please use the provided universal spacers.

Universal Washer Installation

[14]

AM175 - Wood Installation 14

  1. DIMPLES FACING UP
  2. DIMPLES FACING DOWN

Premier Mounts’ Universal Washers are designed to accommodate the various M4, M5, M6 and M8 hole sizes required by flat panels.

**** Do not place excessive pressure on the back of the flat panel, as this may damage your flat panel.

****The Universal Washer must be installed between the head of the mounting screw and the mounting bracket as shown.

Mounting Bracket Installation

[15]

AM175 - Wood Installation 15

  1. Mounting Hardware
  2. Mounting Bracket
  3. Griplate™
  4. Mounting Point
  5. Universal Spacer
  6. Flat
  1. Place your flat panel screen-side down on a soft, flat surface.
  2. Identify the number and location of the thread inserts on the back of your flat panel.
  3. Aligning the holes on each mounting bracket with the thread inserts on the back of your flat panel.
  4. Secure each mounting bracket to your flat panel by inserting a minimum of two (2) screws per bracket.

**** Do not overtighten the mounting hardware.

Adapter Plate Installation (Optional)

[16]

   The adapter plate can be used with mounting patterns from 200mm x 200mm x to 650mm x 840mm.

In the event that you’re flat panel has recessed or uneven mounting surface, universal spacers may be stacked to achieve proper spacing. Select the amount of universal spacer (s) that is closest in depth to keep your adapter plate as close to the flat panel as possible. The universal spacer must be secured between the flat panel and the adapter plates.

**** Do NOT over tighten the screws.

Step 1. Determine if your flat panel will need the adapter plates.
Step 2. Locate the mounting points on the back of the flat panel.
Step 3. Using a screwdriver, insert and tighten the mounting hardware and adapter plates to the back of the flat panel. Do not over tighten the screws.

AM175 - Wood Installation 16a

  1. Adapter Plate
  2. Griplate
  3. Mounting Hardware
  4. Flat Panel

AM175 - Wood Installation 16b

  1. Adapter Plate
  2. Socket Wrench
  3. Nylon Nut
  4. Flat Washer
  5. Universal Mounting Bracket

Step 4. Place the universal mounting brackets over the threaded mounting studs that are on the adapter plate.
Step 5. Place one (1) 5 / 16″ flat washer onto each threaded mounting stud.
Step 6. Thread one (1) M8 Nylon nut onto each threaded mounting stud.

Before tightening the nylon nut, be sure that both universal mounting bracket are level and aligned with each other. If they are not aligned and level, the flat panel will not sit properly when mounted to the AM175.

Step 7. Once the universal mounting brackets are level, use a 1/2″ socket and socket wrench to tighten the M8 nylon nuts. Do not over tighten the screws.

Attaching the Flat Panel to the Wall Plate

[17]

AM175 - Wood Installation 17a    Two people are required for this step.

****Do not release the flat panel until verifying the connection between the universal mounting brackets and the upper and lower mounting bars.

 AM175 - Wood Installation 17b

  1. Upper Mounting Bar
  2. Lower Mounting Bar
  3. Flat Panel

Step 1. Place the universal brackets and the flat panel over and onto the upper and lower mounting bars of the AM175 and lower it down. Do not release the flat panel until the flat panel is resting securely on the upper and lower mounting bars.

Securing the Leveling the Flat Panel

[18]

In the event that the flat panel is tilted too far to one side, the leveling screws will allow you to compensate for this tilt by simply adjusting the screws with a screwdriver (see illustration to the right for a clearer view).

Step 1. Use a screwdriver to adjust the two (2) M6 x 30 leveling screws, located on the top of the mounting brackets.
Step 2. Once the flat panel panel is level, ues a screwdriver to tighten the two (2) M6 x 30 locking screws, located on the bottom of the mounting brackets. Do not over tighten these screws.

AM175 - Wood Installation 18

  1. Screwdriver
  2. Leveling Screw (Pre-installed)
  3. Locking Screw (Pre-installed)
Adjusting the Flat Panel Tilt

[19]

TO ADJUST THE TILT TENSION OF THE AM175, LOOSEN THE TENSION BOLTS LOCATED ON THE BOTTOM RIGHT AND LEFT SIDE OF THE MAIN ARM ASSEMBLY. RE-TIGHTEN THESE BOLTS TO ACHIEVE YOUR DESIRED TENSION.

AM175 - Wood Installation 19

  1. Tension Bolt

Adjusting the Flat Panel Down

Step 1. Place one hand at the center top edge of the flat panel.
Step 2. Place the other hand on the center bottom edge of the flat panel.
Step 3. Using the upper hand, gently pull the top of the flat panel away from the wall while the lower hand gently pushes the bottom of the flat panel towards the wall.

Adjusting the Flat Panel Down

Step 1. Place one hand at the center top edge of the flat panel.
Step 2. Place the other hand on the center bottom edge of the flat panel.
Step 3. Using the upper hand, gently push the top of the flat panel towards the wall while the lower hand gently pulls the bottom of the flat panel towards the wall.

Plastic Channel Cover Installation

[20]

Step 1. Place the plastic channel covers over the Mounting plate (2 side covers and 1 center cover).
Step 2. Gently push each cover into place, covering the mounting slots of the mounting place.

Repeats steps 1 and 2 for the installation for of the lower plastic channel covers.

AM175 - Wood Installation 20

  1. Side Cover (Long)
  2. Center Cover (Short)

PREMIER MOUNTS logo n1

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PREMIER MOUNTS User Manuals

Related Manuals