PREMIER MOUNTS P2642F Low-Profile Mount for Flat-Panels Installation Guide
- June 4, 2024
- PREMIER MOUNTS
Table of Contents
- PREMIER MOUNTS P2642F Low-Profile Mount for Flat-Panels
- Included Components
- Introduction
- Concrete Installation
- Selecting the Mounting Hardware
- Universal Washer Installation
- Lock-it™ Security Barrel Installation (Optional)
- Mounting Bracket Adjustment
- Ultilizing the Security Barrel
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PREMIER MOUNTS P2642F Low-Profile Mount for Flat-Panels
Weight Limit
Maximum Flat Panel Weight:
130 lbs.
Warning Statements
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST
BE READ AND COMPLETELY UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN
EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.
PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE
FOLLOWED, AS OUTLINED IN THESE INSTALLATION INSTRUCTIONS. FAILURE TO DO SO
COULD RESULT IN PROPERTY DAMAGE, SERIOUS PERSONAL INJURY, OR EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS
PRODUCT. USE PROPER SAFETY EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO
PREVENT PERSONAL INJURY.
PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY
PREMIER MOUNTS PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED
OR DAMAGE CAUSED BY UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT
RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS, ACTIONS OR CAUSES OF
ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER
RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.
At least two qualified people should perform the assembly procedure. Personal
injury and/or property damage can result from dropping or mishandling the flat
panel.
If mounting to wall studs or ceiling studs, make sure that the mounting screws
are anchored into the center of the wall studs or ceiling studs. Use of an
edge-to-edge stud finder is recommended.
It is recommended that a maximum of ⅝˝ plaster board be used when mounting to
wooden studs.
Be aware of the mounting environment. If drilling and/or cutting into the
mounting surface, always make sure that there
are no electrical wires in wall. Cutting or drilling into an electrical line
may cause serious personal injury.
Make sure there are no water or natural gas lines inside the wall where the
mount is to be located. Cutting or drilling into a water or gas line may cause
severe property damage or personal injury.
This product is intended for indoor use only. Use of this product outdoors
could lead to product failure and/or serious personal injury.
Do not install near sources of high heat. Do not install on a structure that
is prone to vibration, movement or chance of impact.
Included Components
Required for installation
Introduction
Directional Mounting Arrow
The Directional Mounting Arrow stamped into the top of the P2642F wall
mount indicates which edge is the top.
Wood Stud Installation
- Minimum of 2 by 4 wood stud to be used
- You must secure the wall plate to two (2) wall studs with a minimum of four (4) lag bolts (2 lag bolts for each stud found).
-
Use a stud finder to determine the center of wall studs in the vicinity of the wall plate.
-
Use a pencil to mark the center of each of the wall studs.
-
Place the wall plate against the wall in the desired viewing location.
-
Use a pencil to mark the upper right mounting location along the center of the wall stud.
Drill a “pilot hole” in the center of the upper right mark using a 1/4” drill bit and power drill.
Only use a 1/4″ drill bit when drilling the pilot holes.
-
Place the wall plate against the wall and align it with the pilot hole.
-
Insert one (1) 5/16″ x 3″ lag bolt and one (1) 5/16″ washer into the up per right mounting hole and tighten using a socket wrench and 1/2” socket.
-
Level the wall plate.
-
Use a pencil to mark the remaining three (3) mounting locations along the Center of each wall stud.
Two people are recommended for this step; one person to level the wall plate and another person to drill the pilot holes.
Drill a “pilot hole” in the center of each of the marks with a power drill and a 1/4″ drill bit.
Only use 1/4″ drill bit when drilling the pilot holes.
- Insert one (1) 5/16” x 3” lag bolt and one (1) 5/16” washer into each pilot hole.
- Tighten all lag bolts using a socket wrench and 1/2” socket.
Do not overtighten the lag bolts when attaching the mount to the wall. Improper Installation may result in personal injury or property damage.
Concrete Installation
Two people are recommended for this step: one person to level the wall plate and another person to mark the mounting locations.
Drill four (4) pilot holes of each mark using a drill and 3/8” masonry drill bit. Drill 3 inches deep.
Only use a 3/8″ masonry drill bit when drilling pilot holes.
Insert the Finned Anchors into each pilot hole.
Lightly tap each Finned Anchors into place with a hammer.
- Insert one (1) 5/16” x 3” Lag Bolt and one (1) 5/16” washer into each pilot hole.
- Tighten all lag bolts using a socket wrench and 1/2” socket.
Do not overtighten the lag bolts when attaching the mount to the wall. Improper installation may result in personal injury or property damage.
Selecting the Mounting Hardware
-
Insert a small straw or toothpick into the threaded inserts found on the back of the flat-panel.
-
Use a pencil to mark the depth of the threaded insert on the small straw or toothpick.
-
Mark the straw or toothpick 1/8” above the depth of the threaded insert, as shown in Figure 1.
-
Insert the small straw or toothpick into the remaining threaded inserts to compare and verify their depth using the straw or toothpick’s 1/8” allowance mark.
-
Locate the correct diameter screw for the threaded insert.
If the screw you selected is longer than the 1/8” allowance mark on the small straw or toothpick, as shown in Figure 2 and Figure 3, do not use this screw. The screw length must not bypass the mark. -
Test each size of the screws provided.
The correct screws should thread easily into themounting point and not pull out when tension is applied.
Universal Washer Installation
Premier Mounts’ Universal Washers are designed to accommodate the various M4, M5, M6 and M8 hole sizes required by flat panels.
Do not place excessive pressure on the back of the flat panel, as this may
damage your flat panel.
The Universal Washer must be installed between the head of the mounting screw
and the mounting bracket as shown.
Does your flat panel have:
- Recessed mount points?
- Uneven mount points?
- A curved back?
- Any obstruction near the mount point?
If Yes, you must install Universal Spacers. Remove the mounting brackets,
Universal Washers, and mounting screws from the back of the flat panel.
Proceed to the “Universal Spacer Installation” section.
If No, skip to the “Leveling and Locking Screw Installation” section.
Universal Spacer Installation
Premier Mounts’ Universal Spacers allow you to attach the mounting bracket to
flat panels which have recessed or uneven mount points. Each Universal Spacer
adds ¼˝ to the distance between the mounting bracket and your flat panel.
The Universal Spacers must be stacked and oriented as shown.
The Universal Spacers must only be installed between the mounting bracket and your flat panel.
The Universal Spacers will fit M4, M5, M6 and M8 screw sizes. Proceed to the “Locking and Leveling Screw Installation” section.
Locking and Leveling Screw Installation
Leveling Screw Installation
You must install the leveling screws before you attach the mounting bracket to the back of the flat panel. The leveling screws consists of two (2) M6 x 75mm screws.
Thread one (1) leveling screw into the top mounting hole on each of the mounting brackets. Make sure the leveling screw is securely threaded into the mounting tab before proceeding.
Do not thread the leveling screw any further once it is even with the mounting tab. Threading the leveling screw any further will prevent you from safely attaching the flat panel to the wall plate.
Locking Screw Installation
You must install the locking screws before you attach the mounting bracket to the back of the flat panel. The locking screws consists of two (2) M6 x 75mm screws.
Thread one (1) locking screw into the bottom mounting hole on each of the mounting brackets. Make sure the locking screw is securely threaded into the mounting tab before proceeding.
Do not thread the locking screw any further once it is even with the mounting tab. Threading the locking screw any further will prevent you from safely attaching the flat panel to the wall plate.
Lock-it™ Security Barrel Installation (Optional)
Optional security configurations include:
- PCB-CSL1 (sold separately)
- Padlock (Combination or Keyed; commercially available)
Please read the following directions to install the security barrel:
- Remove the locking screw from the mounting bracket.
- Place the locking screw into and through the security barrel (see illustration below).
- Re-insert the locking screw and security barrel into the mounting bracket.
- Tighten the locking screw and security barrel until seated in the mounting tab.
Do not thread the locking screw any further once it is even with the mounting tab (see illustration to the right). Threading the locking screw any further will prevent you from safely attaching the flat panel to the wall plate.
Proceed to the “Attaching the Mounting Bracket to the Flat Panel” section.
Attaching the Mounting Bracket to the Flat Panel
This section presumes that you have read and understood these sections:
- Selecting the Proper Mounting Hardware
- Universal Washer Installation
- Universal Spacer Installation
- Place your flat panel screen-side down on a soft, flat surface.
- Identify the number and location of the thread inserts on the back of your flat panel.
- Aligning the holes on each mounting bracket with the thread inserts on the back of our flat panel.
- Secure each mounting bracket to your flat panel by inserting a minimum of two (2) screw per bracket.
Do not overtighten the mounting hardware.
Proceed to the “Attaching the Flat Panel to the Wall Plate” section.
Attaching the Flat Panel to the Wall Plate
This section requires two people.
Do not release your flat panel until you are certain that top and bottom hooks of both mounting brackets are securely seated on the upper and lower mounting rails of the wall panel.
- Raise the flat panel past the top and bottom mounting rails on the wall panel.
- Slide the flat panel down slowly, keeping it close to the wall.
- Engage the top and bottom mounting brackets to the rails of the wall plate.
Proceed to the “Mounting Bracket Adjustments” section.
Mounting Bracket Adjustment
Leveling Screw Adjustment
If your flat panel is tilted too far to one side, the leveling screws will
allow you compensate for this tilt by simply adjusting the screws with a
screwdriver.
- Loosen both locking screws.
- Adjust the tilt of your flat panel.
- Tighten both locking screws.
Caution!
It is possible to dislodge your flat panel while you level your flat panel.
Use extreme caution until you tighten the locking screws.
Locking Screw Adjustment
After you have finished leveling your flat panel, be sure to tighten the two
(2) M6 x 75mm locking screws.
Do not overtighten the locking screws.
Ultilizing the Security Barrel
Your P2642F Mount includes one (1) Security Barrel which can provide
additional theft deterrence for your flat panel.
PCB-CSL1 Security Cable –
- Thread the cable through the hole on the security barrel.
- Attach the PCB-CSL1 locking mechansim and secure it using the supplied key.
Padlock
- Place the locking hook through the hole of the security barrel.
- Snap lock and locking hook together.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>