biamp ALC-404D Amplified Loudspeaker Controllers User Guide
- June 10, 2024
- biamp
Table of Contents
- biamp ALC-404D Amplified Loudspeaker Controllers
- Product Information
- Product Usage Instructions
- Packing List
- Common symbols and meanings
- EC Declaration of Conformity
- Preliminary operations
- Connections
- Networking
- ArmoníaPlus System Manager
- Location
- Cooling
- Exposing the Control Panel
- Dimensions
- Front Panel
- Rear Panel
- LED Charts
- Control Panel
- Warranty and Assistance
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
biamp ALC-404D Amplified Loudspeaker Controllers
Product Information
The Community Amplified Loudspeaker Controllers are designed to provide extraordinary audiovisual experiences. The product is available in different models including ALC-404D, ALC-1604D, ALC-3202D, ALC-404AN, ALC-1604AN, and ALC-3202AN. The packing list of the product includes Phoenix connectors, IEC power cord, and a safety guide. The product is compliant with all the applicable European directives as indicated by the CE-mark. The product is designed for indoor use only and should not be used at altitudes above 2000m or in tropical environments.
Product Usage Instructions
- Before using the product, ensure that the electrical power cord is not frayed or broken.
- Do not touch any exposed speaker wiring while the amplifier is operating to avoid electrical shock.
- Do not spill water or other liquids into or on the ALC.
- The device must be powered exclusively by earth-connected mains sockets in electrical networks compliant to the IEC 364 or similar rules.
- Disconnect the AC mains source before attempting to clean any part of the amplifier.
- Properly fit the AC mains plug to the amplifier inlet. Before powering this ALC, verify that the correct voltage rating is being used.
- Take care to lock the output terminal before switching the device on.
- Verify that your mains connection is capable of satisfying the power ratings of the device.
- Unplug the output connectors before proceeding with the self-check procedure.
- No open flame sources such as lighted candles should be placed on the amplifier.
- To prevent injury, this apparatus must be securely rack-mounted in accordance with the installation instructions.
MODELS
- ALC-404D
- ALC-1604D
- LC-3202D
- ALC-404AN
- ALC-1604AN
- ALC-3202AN
Packing List
The box contains the following: 1x ALC-3202 (D or AN model)
(Phoenix connectors plugged in)
-
1x Phoenix MC 1,5/4-ST-3,81 – 1803594 plug
3x Phoenix MC 1,5/6-ST-3,81 – 5447900 plug
1x Phoenix PC 5/4-STF1-7,62 – 177859 plug -
3x IEC power cord
1x Safety guide
OR
1x ALC-404 or ALC-1604 (D or AN model)
(Phoenix connectors plugged in)
1x Phoenix MC 1,5/4-ST-3,81 – 1803594 plug
3x Phoenix MC 1,5/12-ST-3,81 – 1803675 plug
1x Phoenix PC 5/8-STF1-7,62 – 177891 plug -
3x IEC power cord
-
1x Safety guide
In an effort to reduce the quantity of printed material while enhancing the
quality of content, we have decided to adopt a new approach for the production
of this quick guide. The safety and regulatory information is included in the
box along with a QR code directing the installer/user to this Installation and
Operation Guide pdf available on Biamp’s website.
Vital information descriptions have been condensed in two pages, and all
illustrations and tables follow. Each section’s color bar (ex. ) refers to the
outlined area on front or rear panel of the ALC image and the corresponding
information
tables. Call-out bubbles guide you to specific elements of those sections.
Please take time to read and understand all warnings and safety instructions
on the next few pages of this manual.
ArmoníaPlus is a trademarked control software product from Powersoft S.p.A.
Additional important information regarding ArmoníaPlus software and networking
setup is explained in this Cornerstone article.
Common symbols and meanings
- THE TRIANGLE WITH THE LIGHTNING BOLT IS USED TO ALERT THE USER TO THE RISK OF ELECTRIC SHOCK.
- THE TRIANGLE WITH THE EXCLAMATION POINT IS USED TO ALERT THE USER TO IMPORTANT OPERATING OR MAINTENANCE INSTRUCTIONS.
- THE CE-MARK INDICATES THE COMPLIANCE OF THE PRODUCT TO ALL THE APPLICABLE EUROPEAN DIRECTIVES
- SYMBOL FOR EARTH/GROUND CONNECTION.
- SYMBOL INDICATING THAT THE EQUIPMENT IS FOR INDOOR USE ONLY.
- SYMBOL FOR CONFORMITY WITH DIRECTIVE 2012/19/EC OF THE EUROPEAN PARLIAMENT ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE).
Safety Warnings
-
OPERATING TEMPERATURE RANGE: 0°C TO +35°C – DERATING ABOVE 35°C.
-
STORAGE RELATIVE HUMIDITY RANGE: 10% TO 85% HUMIDITY (NON CONDENSING).
-
DO NOT USE THE UNIT AT ALTITUDES ABOVE 2000 M.
-
DO NOT USE THE UNIT IN TROPICAL ENVIRONMENT.
-
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT. NO USER- SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
-
CONNECTION TO THE MAINS SHALL BE DONE ONLY BY A ELECTROTECHNICAL SKILLED PERSON ACCORDING THE NATIONAL REQUIREMENTS OF THE COUNTRIES WHERE THE UNIT IS SOLD.
-
DO NOT USE THIS ALC IF THE ELECTRICAL POWER CORD IS FRAYED OR BROKEN.
-
TO AVOID ELECTRICAL SHOCK, DO NOT TOUCH ANY EXPOSED SPEAKER WIRING WHILE THE AMPLIFIER IS OPERATING.
-
DO NOT SPILL WATER OR OTHER LIQUIDS INTO OR ON THE ALC.
-
THIS DEVICE MUST BE POWERED EXCLUSIVELY BY EARTH CONNECTED MAINS SOCKETS IN ELECTRICAL NETWORKS COMPLIANT TO THE IEC 364 OR SIMILAR RULES
-
****DISCONNECT THE AC MAINS SOURCE BEFORE ATTEMPTING TO CLEAN ANY PART OF THE AMPLIFIER
BIAMP SUGGESTS PLUGGING THE AMPLIFIER TO A 16 A RATING, C OR D CURVE, 10 KA SECTIONING BREAKER. -
OUTPUT TERMINALS ARE HAZARDOUS: WIRING CONNECTION TO THESE TERMINALS REQUIRES INSTALLATION BY AN INSTRUCTED PERSON AND THE USE OF READY MADE LEADS.
-
PROPERLY FIT THE AC MAINS PLUG TO THE AMPLIFIER INLET.
BEFORE POWERING THIS ALC, VERIFY THAT THE CORRECT VOLTAGE RATING IS BEING USED. -
TAKE CARE TO LOCK THE OUTPUT TERMINAL BEFORE SWITCHING THE DEVICE ON.
-
VERIFY THAT YOUR MAINS CONNECTION IS CAPABLE OF SATISFYING THE POWER RATINGS OF THE DEVICE.
-
IT IS HIGHLY RECOMMENDED TO UNPLUG THE OUTPUT CONNECTORS BEFORE PROCEEDING WITH THE SELF CHECK PROCEDURE
-
NO OPEN FLAME SOURCES SUCH AS LIGHTED CANDLES SHOULD BE PLACED ON THE AMPLIFIER.
-
TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY RACK MOUNTED IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.
-
THIS EQUIPMENT SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 2 M
-
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED TO PERSONS, THINGS OR DATA DUE TO AN IMPROPER OR MISSING GROUND CONNECTION.
-
IT IS ABSOLUTELY NECESSARY TO VERIFY THESE FUNDAMENTAL REQUIREMENTS OF SAFETY AND, IN CASE OF DOUBT, REQUIRE AN ACCURATE CHECK BY QUALIFIED PERSONNEL.
-
IT IS HIGHLY RECOMMENDED TO UNPLUG THE OUTPUT CONNECTORS BEFORE PROCEEDING WITH THE SELF CHECK PROCEDURE
-
THE TESTING SIGNALS MIGHT CAUSE LOUDSPEAKER IMPAIRMENTS.
This unit has been engineered and manufactured to ensure your personal safety.
But IMPROPER USE CAN RESULT IN POTENTIAL ELECTRICAL SHOCK OR FIRE HAZARD.
In order not to defeat the safeguards incorporated into this product, observe
the following basic rules for its installation, use and service. Please read
these “Important Safeguards” carefully before use.
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this equipment near water.
- Clean only with a dry cloth.
- Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
- Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
- Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Use only with the rack, cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
- Unplug this apparatus during lightning storms or when unused for long periods of time.
- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
- The apparatus shall be connected to a MAINS socket outlet with a protective earth grounding connection
- Where the MAINS plug or an appropriate coupler is used as the disconnect device, the disconnect device shall remain readily operable.
Contact the authorized service center for ordinary and extraordinary
maintenance.
IMPORTANT: Review all safety requirements and have qualified personnel
verify as necessary.
EC Declaration of Conformity
Biamp Systems, LLC
9300 S.W. Gemini Drive
Beaverton, OR 97008
USA
We declare that under our sole responsibility the products:
Model Names:
- ALC-404D
- ALC-1604D
- ALC-3202D
- ALC-404AN
- ALC-1604AN
- ALC-3202AN
Intended use: Professional Audio Amplifier
Are in conformity with the provisions of the following EC Directives,
including all amendments, and with national legislation implementing these
directives:
- 2014/35/EU Low Voltage Directive
- 2014/30/EU Electromagnetic Compatibility Directive
- 2011/65/EU RoHs Directive
The following harmonized standards are applied:
- EN 55032:2012,
- EN 55032:2012/AC:2013
- EN 55035:2017
- EN 61000-3-2:2014
- EN 61000-3-3:2013
- EN 61000-3-11:2000
- EN 62368-1:2014
- EN 62368-1:2014/AC:2015
Complies with:
- CAN/CSA-C22.2 No. 62368-1:14
- UL 62368-1 2nd Ed.”
Regulatory Compliance Statements
Europe
If the time arises to dispose of your product, please recycle all possible
components.
This symbol indicates that when the end-user wishes to discard this product,
it must be sent to separate collection facilities for recovery and recycling.
By separating this product from other household-type waste, the volume of
waste sent to incinerators or land-fills will be reduced and natural
resources will thus be conserved. The Waste Electrical and Electronic
Equipment Directive (WEEE Directive) aims to minimize the impact of electrical
and electronic goods on the environment. Biamp comply with the Directive
2012/19/EU of the European Parliament on waste electrical finance the cost of
treatment and recovery of electronic equipment (WEEE) in order to reduce the
amount of WEEE that is being disposed of in land-fill site. All of our
products are marked with the WEEE symbol; this indicates that this product
must NOT be disposed of with other waste. Instead it is the user’s
responsibility to dispose of their waste electrical and electronic equipment
by handing it over to an approved reprocessor, or by returning it to Biamp for
reprocessing. For more information about where you can send your waste
equipment for recycling, please contact Biamp or one of your local
distributors.
USA
FCC Supplier’s Declaration of Conformity
Responsible Party:
Biamp Systems, LLC
9300 S.W. Gemini Drive
Beaverton, OR 97008 USA
biamp.com
FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit
- Different from that to which the receiver is connected.
WARNING: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures
Canada
Canadian Caution
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s).
Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
WARNING: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures
ICES-003 Class A Notice – Avis NMB-003, Classe A
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du
Canada.
Radiation Exposure Statement
This equipment complies with RSS-102 radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator & your body.
Preliminary operations
Location
Install your Biamp Amplified Loudspeaker Controller (ALC) in well ventilated
rack cabinets.
Secure both front and rear brackets to the rack.
Connect the AC Mains connector to a circuit breaker.
Install the ALC far from EMF emitting devices.
Avoid placing the ALC close to heat generating sources.
Cooling
The ventilation openings must not be impeded by any item, keep a distance of
at least 19.7 in. (50 cm) from the front and rear ventilation openings of the
ALC.
Biamp ALCs implement a forced-air cooling system to maintain constant
operating temperatures. Air enters from the front panel, exiting at the back
of the unit.
The cooling system features variable-speed DC fans controlled by the heat sink
mounted sensors. This ensures that fan noise and internal dust accumulation
are kept to a minimum.
In the rare event of overheating, sensing circuits shut down all channels
until the ALC cools down to a safe operating temperature. Normal operation is
resumed automatically without the need for user intervention.
ALCs can be stacked one on top of the other, leave one rack unit empty every
four to guarantee adequate air flow.
Cleaning
Use a dry cloth for cleaning the chassis and the front panel. Air filter
cleaning should be scheduled in accordance with the dust levels in the ALC’s
operating environment.
In order to clean the vent filters remove the front cover by firmly gripping
the outermost black panels and pull them outwards
Use compressed air to remove the dust from filters, or wash them with clean
water (let the filter dry thoroughly before reinstalling them).
AC Mains Supply
ALCs implement an universal switching mode power supply with power factor
correction operating in the range from 100 VAC up to 240 VAC ±10%.
AC mains connection is in the rear panel through the IEC C20 inlet, the
approved power cord is provided.
Switching the ALC On and Off
Once properly powered (power cord inserted, sectioning breaker closed), the
system can be either ON or in STANDBY mode depending on its state at latest
power off.
In order to toggle the ALC between ON and STANDBY press and hold the power
button for 3 seconds. Please consider that the operating condition can be
modified by the REMOTE ON and REMOTE OFF configuration.
Energy Save
The Smart Rails Management technology implemented in the power supply unit
allows to reduce the power consumption when the input signal falls under a
defined threshold.
When On, Energy Save is active on each channel independently.
If the signal is missing for more than 30 minutes on all channels, the auto
standby is applied and the main PSU is turned off to further save energy (Time
out time is selectable via ArmoníaPlus). Normal operation is resumed in a
matter of milliseconds when an incoming signal is detected.
In order to activate the Energy Save feature, operate the NRG SAVE dip switch
on the rear panel.
Breaker Save
This feature may be activated when the power grid is unable to provide enough
current to continuously drive the loads, or when the number of ALCs connected
to the same outlet is such that one can reach the critical power absorption of
the line.
When activated, the Breaker Save halves the maximum continuous current
absorption from the mains. This slightly reflects on the overall performance
of the system, reducing the available output power.
In order to activate the Breaker Save feature, locate the BRK SAVE switch on
the rear panel.
Remote On/Off
Remote ON/OFF is available through the dedicated terminals on the rear panel.
Both terminals respond to the differential voltage between the contacts: a
voltage difference in the range 5 VDC – 24 VDC triggers the control. Any
voltage exceeding 28 VDC may damage the input circuitry.
The couple of terminals act depending on the actual state of the ALC, in
accordance with the following table.
REMOTE ON | REMOTE OFF | ALC STATE |
---|---|---|
Vdiff ≥ 5V | Any | Force Turn ON |
Vdiff < 3V | Vdiff ≥ 5V | Force Turn OFF |
Vdiff < 3V | Vdiff < 3V | No Change |
(Returns to last state set by front panel switch)
Gain selection
ALCs can operate with different gain applied to the input signal. This feature
is designed to match the voltage of the input signal.
A proper combination of the position of two GAIN switches on the rear panel
sets the operating gain of the amplifier
Connections
Signal Grounding
There is no ground switch or terminal on the ALCs. The unit’s signal grounding
system is automatic. In order to limit hum and/or interference entering the
signal path, use balanced input connections.
In the interests of safety, the unit MUST always operate with electrical
safety earth connected to the chassis via the dedicated Protective Earth wire.
Analog Audio Input Connections
Analog input connections are made via the Phoenix MC 1,5/6-ST-3,81 5447900
connector on the ALC-3202 (or via the Phoenix MC 1,5/12-ST-3,81 1803675
connector on the ALC-404 or ALC-1604).
Remote Level Adjustment
The level of each channel can be remotely adjusted by means of a linear 10 kΩ
potentiometer connected to the input LEVEL connector.
When the CH1 MSTR switch is in the OFF position the remote level
potentiometers work independently on each separate channel.
When the CH1 MSTR switch is in the ON position the remote level potentiometer
of channel 1 acts as a master level, controlling the volume of all channels.
The remote level controls are in series with the level adjustment knobs in the
front panel.
Ethernet Connection
The port labeled Ethernet is designed to remotely control the ALC via an
Ethernet connection through a personal computer and Powersoft ArmoníaPlus
System Manager software.
Powersoft recommends the use of Ethernet Cat5 straight through patch cables
with pin/pair assignments TIA/EIA-568-B, i.e. T568B.
Digital Audio Input Connection
ONLY AVAILABLE ON “D” MODELS. ALC “D” models accept two/four input streams
from the Dante® connection through the Dante® port. Cabling must comply to
TIA/EIA-568-B and adopt the T568B scheme pinout.
In order to implement a Dante® network, a computer running Dante® Controller
have to be used. Dante® Controller is a software application that manages
devices on the network. ALC-Ds are automatically discovered and displayed in
Dante® Controller with the default identifier: MODELNAME-SERIAL (e.g.ALC-
3202D-71520).
Output Connections
Output connections are made via the Phoenix PC 5/4-STF1-7,62 177859 port (or
PC 5/8-STF1-7,62 177891 port ALC-404/1604).
Any mixed configuration of low and high impedance output loads can be made: in
order to set the load configuration, each channel is provided with four DIP
switches.
Hi-Z 70V/100V Operations
Any channel can drive 70V/100V (Hi-Z) distributed line loudspeakers. To
connect any channel’s output to a 70V/100V line, set the rear panel DIP switch
corresponding to the channel.
When using Biamp ALC’s with factory-authored loudspeaker presets, it is not
necessary to use the built-in HPF (High Pass Filter) DIP switches on the rear
of the amplifier. While these switches can select a HPF of 35Hz or 70Hz, each
Biamp 70V / 100V loudspeaker preset already includes a HPF appropriate for the
selected loudspeaker model.
Low-Z 2Ω Load Operation
The 2Ω switch allows activation of all output channels set to match the low
impedance operating condition (i.e. in Low-Z configuration) optimizing the
performance with very low loads, by limiting the maximum output voltage to 85
Vpeak per channel.
When using ALC’s with Biamp-authored loudspeaker presets this switch becomes
redundant and can be ignored. Each loudspeaker preset already includes
limiters preset to values that will limit voltages to safe operating levels.
If using an ALC without a Biamp-authored loudspeaker preset, use this switch
as intended for 2Ω loads. Never connect loads lower than 2Ω to any output
channel on any ALC under any circumstances.
Diagnostics – GPO – Alarms
ALCs provide a pair of paralleled general purpose output connections per
channel: one Normally Open NO and one Normally Closed
NC.
The connections are available on the back panel via the 6-pin (ALC-3202) or
12-pin (ALC-404/1604) Phoenix connectors.
When the amplifier is in normal operating condition the NO contacts are
closed, while the NC contacts are open, and vice-versa.
These contacts are used to report potentially dangerous faults or generally
unsafe operation conditions by toggling alarm switches relative to the
following events, and any fault preventing the normal operation of an output
channel:
No AC mains (i.e. system shutdown)
Thermal stress (the system temperature is too high and the thermal protection
is engaged)
Short circuit in output wiring (either the loudspeaker or the line is in
short)
ALC is in Standby
All ALCs feature further monitoring on pilot tone and output load through
ArmoníaPlus System Manager.
Self Check
The self check procedure tests the ALC status and reports the user in case of
failures.
After few minutes, at the end of the self check procedure, a combination of
lit LED in the LED panel provides information about the amplifier status.
In order to exit the self check test and resume normal operations,
press the self check push button once 6 .
If self check cannot be started because of a fault, the check LED will blink
fast, while a reassuring slow blink is an indication of a completed self check
procedure.
Pilot Tone Monitoring
The detection of a mismatch in the input pilot tone parameters (frequency and
voltage level) can be used to trigger the backup policy and activate an alert
through the general purpose output switch.
The output pilot tone detection relies on an external signal passing through
the ALC or the internal post DSP pilot tone generator; in both cases any
mismatch between the detected signal and the set thresholds triggers the
general purpose output switches.
Networking
ALCs support star network topology via the Ethernet port and Dante® networking via the Dante® port.
IP Addressing
Factory default network settings are DHCP/AutoIP, in order for the ALC to
self-configure when connected to an existing LAN or PC. Fixed IP policy can
also be adopted and configured through ArmoníaPlus System Manager.
If a DHCP server is not active within the network, the ALC platform initiates
a stateless address auto-configuration (i.e. Zero-configuration networking
methodology). It self-assigns a local numeric network address (of the type
169.254.x.y – 172.31.. for the secondary network if present – with a subnet
mask 255.255.0.0) and automatically distributes and resolves the host names of
the networking devices.
Both ArmoníaPlus and the ALC must belong to the same subnet. If a DHCP server
is present on the network and an ALC is in AUTO IP, networking may become
unstable.
IMPORTANT: As a rule of thumb, turn the DHCP server ON before connecting
the ALCs.
IP addressing of an ALC is established during the bootstrap: when the
amplifier discovers a DHCP server on the network during the startup, it
negotiates the networking parameters. If the ALC does not reveal a DHCP server
on the network during the startup, it sets itself in AUTO IP mode.
ArmoníaPlus System Manager
ArmoníaPlus System Manager is the configuring interface that allows system setting and customization of the ALCs. ArmoníaPlus can be installed on a PC running Windows (7 and higher). Download ArmoníaPlus System Manager for free from the website: here.
Input Selection and Backup Policy
The “D” models allow two input signal sources per channel: analog and Dante®
streams, whereas the “AN” models have a single input to allow only analog
signals. ArmoníaPlus System Manager software provides an interface to select
the input source.
Dual input models only: ALCs implement a backup policy aimed to improve
reliability against signal fault. By assigning a bus priority to the different
input sources per channel, the system is able to automatically switch to a
reliable input connection in case of signal drop or pilot tone mismatch.
Output Load Monitoring
Through the ArmoníaPlus System Manager software it is possible to set the
thresholds on the load impedance, at given frequency, that trigger the general
purpose output of any channel in ALCs.
Location
Cooling
Exposing the Control Panel
Dimensions
Front Panel
Control Panel
1| OPERATING MODE LEDS (ON/STANDBY)
2| POWER PUSHBUTTON
3| ARMONÍAPLUS CALLBACK PUSHBUTTON
4| SOFT RESET PUSHBUTTON
5| HARD RESET PUSHBUTTON
6| SELF CHECK PUSHBUTTON
7| CH1, CH2 ATTENUATORS (+ CH3, CH4 – ALC-404D, ALC-1604D)
LED Panel
8| CHANNEL STATUS LED METERS
9| SYSTEM STATUS LEDS
Serial Port
RESERVED FOR SERVICE OPERATIONS.
Rear Panel
AC Mains Connector
IEC C19
Output section
10| OUTPUT CONNECTOR
Output section
- OUTPUT CONFIGURATION DIP SWITCHES
Low-Z | High-Z | 100V | 70V | HPF @ 35 Hz | HPF @ 70 Hz |
---|---|---|---|---|---|
A | __ | ||||
B | __ | __ | |||
C | __ | __ | __ | ||
D | __ | __ | |||
E | __ | __ | |||
F | __ | __ | __ | ||
G | __ | __ |
ALC “AN” models do not have a Dante Port
Input section
- REMOTE LEVEL CONNECTOR
- LINE INPUT CONNECTOR
Remote On/Off-Configuration dip switches
14| REMOTE ON/OFF CONNECTOR (PHOENIX MC 1,5/4-ST-3,81 1803594)
15| SYSTEM CONFIGURATION DIP SWITCHES
NOTE: ALC-404 and ALC-1604 models only. (ALC3202 does not need a dip switch setting for 2 Ω operation).
Ethernet and Dante ® ports
16| ETHERNET PORT (RJ45)
17| DANTE® PORT (RJ45) – ALC “D” MODELS ONLY NO PORT – ALC “AN” MODELS
LED Charts
LED Bars, signal metering
LED Bars, signal metering 8|
---|---
Color| Signal Metering| Warnings
Lighting| Description
| ORANGE| Clipping ALC User Limiter| —| —
| YELLOW| -6dB| SOLID ON| Thermal warning Thermal protection engaged
FLASHING| Auto Standby
| GREEN| -12dB| —| —
| GREEN| -24dB| —| —
|
GREEN
| ****
-60dB
| SOLID ON| Signal presence
BLINKING| Channel muted
| GREEN| —| SOLID ON| Channel ready
| RED| —| SOLID ON| Channel fault1
Red LED lights on in case of any kind of channel fault that prevents the normal channel operating.
Lighting | Timings | Description |
---|---|---|
FLASHING | 100 ms ON 900 ms OFF | |
BLINKING | 500 ms ON 500 ms OFF |
LED Bar, system status
Color | Name | Warnings |
---|---|---|
Lightning | Description | |
**** | ORANGE | LIMIT |
SOLID ON | Breaker Save limiting power draw | |
**** | YELLOW | TEMP |
**** | ORANGE | CHECK |
BLINKING | Self check completed | |
FAST BLINKING | Self Check Unavailable | |
**** | GREEN | REMOTE |
OFF | Not connected to ArmoníaPlus | |
**** | GREEN | POWER ON |
OFF | System off |
| GREEN| MAINS| SOLID ON| AC mains voltage within the operating range
OFF| Undervoltage
FLASHING| Over/Undervoltage Warning
FAST BLINKING| Overvoltage
BLINKING| Mains FUSES blown
****| RED| ALARM| SOLID ON| PSU fault1 OR Critical Faults
Red LED lights on in case of any kind of PSU fault that prevents normal operating.
Lighting | Timings | Description |
---|---|---|
FLASHING | 100 ms ON | |
400 ms OFF | ||
FAST BLINKING | 100 ms ON | |
100 ms OFF | ||
BLINKING | 500 ms ON | |
500 ms OFF |
Operating mode LEDs
Color | Name | Operating mode |
---|---|---|
Standby | Power On | |
GREEN | POWER ON | — |
ORANGE | STANDBY | SOLID ON |
ORANGE | AUTO STANDBY | BLINKING |
ORANGE | ERROR CODE | BLINK COUNTER |
Control Panel
Label | Label | Type | Action | Description |
---|---|---|---|---|
2 | POWER | Pushbutton | keep pressed for 3 seconds | Toggle system ready / |
standby mode
3| CALL| Pushbutton| press| Highlight the ALC in the ArmoníaPlus
workspace
4| SOFT RESET1| Pushbutton| keep pressed for 3 seconds| Reset network
parameters to factory default
5| HARD RESET1| Pushbutton| keep pressed for 3 seconds| Reboot the
system
6| CHECK| Pushbutton| keep pressed for 3 seconds| Start the self-
checking procedure3
7
| CH12| Potentiometer| turn counter-clockwise| Attenuate the output level of
the signal on channel 1
CH22| Potentiometer| turn counter-clockwise| Attenuate the output level of the
signal on channel 2
The push-buttons are disabled when connected to Armonía.
- Keep pressed both the SOFT RESET button and the HARD RESET button for at least 3 seconds to completely reset the ALC to its factory default configuration (any preset stored in the internal memory will be lost and replaced with a flat preset).
- The potentiometer is in series with the remote level control so it can be used to limit the output volume regardless of any remote adjustment.
- Press again to resume normal operations.
Self Check
-
SYSTEM OK.
-
POWER SUPPLY FAULT
-
AC MAINS VOLTAGE OUT OF RANGE (OVER/UNDER VOLTAGE)
-
PSU TEMPERATURE OUT OF RANGE
-
FAN ERROR
-
CHANNEL# OUTPUT WAVEFORM NON-CONFORMITY
-
CHANNEL# TEMPERATURE OUT OF RANGE
-
CHANNEL# OUTPUT CURRENT MEASUREMENT NON-CONFORMITY1
- An 8Ω dummy load is needed to measure the output current. If the dummy load is not applied the system reports a fault.
Warranty and Assistance
Biamp guarantees its manufactured products to be free from defective
components and factory workmanship for a period of time starting from the date
of purchase printed on Biamp’s (or any of its Authorized Dealer’s) invoice to
the end customer.
The standard warranty period is: 48 months for rack ALC units.
All warranty repairs and retrofits must be performed at Biamp facilities or at
an Authorized Service Center at no cost for the purchaser. Warranty exclusion:
Biamp’s warranty does not cover product malfunctioning or failure caused by:
misuse, abuse, repair work or alterations performed by non-authorized
personnel, incorrect connections, exposure to harsh weather conditions,
corrosive environments, mechanical damages (including shipping accidents), and
normal wear and tear. Biamp will perform warranty services provided that the
product is not damaged during transportation.
Return of Goods
Goods can be returned to Biamp only after they have been granted a Return
Merchandise Authorization (RMA) number to be attached to the external
packaging. Biamp (or its Authorized Service Center) has the right to refuse
any returned good without a RMA number.
Repair or Replacement
Biamp reserves the right to repair or replace any defective goods covered
under the product warranty at its sole discretion and as it deems best.
Cost and Responsibility of Transport
The purchaser (or end user/customer) is solely responsible for all
transportation costs and risks associated with sending warranty covered goods
to Biamp or its Authorized Service Center. Biamp will assume full
responsibility and cover all costs incurred to send the goods back to the
purchaser (or end user/customer
Warranty
Assistance
All servicing and repairs for Biamp ALCs is handled by Powersoft Worldwide,
but processing of warranty claims must be submitted to Biamp first. Please
follow the instructions below in case of any difficulties.
There are no user-serviceable parts in the ALC unit. Refer to qualified
technical personnel for servicing. If your ALC needs repair, contact Biamp’s
Technical Service Department.
- Take a note of each serial number of the units to be returned.
- Completely fill out the defect report form for each unit to be returned. Send the completed defect report form to support@biamp.com.
After having applied the aforementioned procedure, the Biamp service manager
will work with Powersoft to determine the appropriate Service Center to which
the ALCs must be shipped and the product’s warranty status. Biamp will also
provide RMA numbers for each unit.
Do not contact Powersoft directly for Biamp ALC servicing or repairs. All
claims must be processed by Biamp.
Note: The ALCs and Community branded loudspeakers are part of the Biamp family of products. Please contact Biamp support with any questions or concerns.
In-Warranty Repairs
The service repair will be free of charge for the customer.
Out of Warranty Issues
- The service costs are calculated on the local rate applied from the service center and supervised by Biamp.
- The repair time has been set by Biamp and it’s equally applied in all the authorized service center
- The unit will be evaluated by a technician, and the service center will provide the customer with the estimated costs.
- The repair will only take place once the customer has approved the estimated costs.
- The customer will pay the shipping charges once the repair has been completed, depending on the countries’ standard procedures.
For any inquiries please email Biamp’s Technical Service Department at support@biamp.com and include “ALC Inquiry” in the subject line.
Shipping the product for factory service
- Record each serial number of the units to be returned.
- Fill out completely the defect report form for each unit to be returned.
- Send the completed defect report form to the following email address: support@biamp.com.
After having applied the aforementioned procedure, you will receive an email from Biamp containing the Return Merchandise Authorization (RMA form) for each unit returned and a Service Center shipping address. All ALCs must be shipped to the specific Service Center address provided by Biamp, units shipped to any other location will be rejected.
Phone Support Hours
Monday – Friday 8.30 AM to 5.00 PM Eastern Time Zone ph: +1 610 876-3400
Important Note: Mark or write the RMA# on the outside of the box in a
prominent place. If the RMA# is not displayed on the outside of the box, the
shipment will be rejected and sent back to the customer.
Dead on Arrival (D.O.A.) Procedure
In case of a “dead on arrival” D.O.A. product, we ask the customer to contact
the Biamp Service Department, mentioning the serial number of the faulty unit.
The D.O.A. unit will be replaced completely without any additional charges!
Important Note: To avoid any warranty issue, do NOT tamper with, or
operate the D.O.A. unit in any way. Biamp declines any D.O.A. product warranty
service if the returned unit has been tampered with or misused by the
customer.
Dante® is a registered trademark of Audinate.
CONTACT US
Email: support@biamp.com
Web: support.biamp.com
Warranty: biamp.com/legal/warranty-information
Compliance: compliance@biamp.com
A: 9300 Gemini Drive, Beaverton, OR 97008
W: www.biamp.com