Midea MKO 41-12 MS BK Oven Installation Guide
- June 10, 2024
- Midea
Table of Contents
Midea MKO 41-12 MS BK Oven
Product Information
The product is an appliance that is constantly upgrading. The thickness of the cabinet board is 20 mm. If the power socket is installed on the back of the appliance, the depth of the cabinet opening shall be increased from a minimum of 590 mm to 620 mm. The dimensions in the figures are in mm. There are two types of cabinets that can be used with the appliance, standing and ground cabinet. The minimum bottom ventilation area required is 250 mm2. If the appliance is installed under the hob, the minimum thickness of the worktop will depend on the type of hob installed.
Product Usage Instructions
When installing the appliance, ensure that the thickness of the cabinet board
is 20 mm and the depth of the cabinet opening is increased to 620 mm if the
power socket is installed on the back of the appliance. The minimum bottom
ventilation area required is 250 mm2 and should be provided accordingly.
If using a standing cabinet, ensure that there is a minimum of 590 mm opening
and refer to the cabinet diagram for further details on the reserve
measurements for the door panel. If using a ground cabinet, there should be a
minimum opening of 570*560+8 mm and refer to the cabinet diagram for further
details on the reserve measurements for the door panel.
If installing a hob with the appliance, refer to the table provided in the
product information section to determine the minimum thickness of worktop
required for each type of hob.
INSTALLATION
- As the appliance is constantly upgrading, the actual appliance shall prevail if the picture is different from the actual appliance.
- The thickness of the cabinet board is 20 mm.
- If the power socket is installed on the back of the appliance, the depth of the cabinet opening shall be increased from a minimum of 590 mm to 620 mm.
- The dimensions in the figures are in mm.
Cabinet Diagram
Standing Cabinet
- Reserve 5 mm for the door panel at the top and bottom respectively.
- Reserve 20 mm for the door panel on the left and right respectively.
- Reserve 20 mm for the door panel in thickness.
Ground Cabinet
- Reserve 5 mm for the door panel at the top and bottom respectively.
- Reserve 20 mm for the door panel on the left and right respectively.
- Reserve 20 mm for the door panel in thickness.
Without hob
With hob
If the appliance is installed under the hob, the minimum thickness of worktop A is shown below: