SIEMENS OOH740 Cerberus PRO Cerberus FIT Automatic Fire Detectors
Product Information
The CerberusTM PRO / CerberusTM FIT automatic fire detectors, models OOH740
and OOHC740, are designed to be resistant to
environmental and interfering influences such as dust, fibers, insects,
moisture, extreme temperatures, electromagnetic interference, corrosive
vapors, vibration, artificial aerosols, and atypical fire phenomena. They are
shock-resistant and offer protection against sabotage. These detectors feature
signal processing with ASA technology (Advanced Signal Analysis), time and
process-dependent detection behavior, and a high degree of immunity to faults
in power electronics. They also have protected electronics and high-quality
components, sophisticated sensors and electronic monitoring, and an integrated
line separator that locates the defective part on the detector bus of the
recess-mounted supply lines. The OOH740 model can also be used on a collective
detector line or a conventional detector line. These detectors are
environmentally friendly, with reusable materials, and electronic parts and
synthetic materials that can be easily separated.
Product Usage Instructions
The OOH740 multi-sensor fire detector is designed for early detection of
flaming fires of solid and liquid substances, as well as smoldering fires. It
can also be used for early and reliable fire detection in an environment with
deceptive phenomena. The detector can be set as a multi-sensor smoke detector,
smoke detector, or heat detector by the software. Its selectable detection
behavior is thanks to application-specific ASA parameter sets. This detector
can be used on an addressed detector line, a collective detector line, or a
conventional detector line.|
The OOHC740 fire and CO detector is also a multi-sensor fire detector with an
additional CO sensor that increases the point detector’s response behavior and
immunity to deceptive phenomena.
It functions using an electro-chemical CO cell and sends a technical message
if the temperature or CO concentration exceeds/falls below the preset limits.
The CO concentration alarm is transmitted to an independent technical CO alarm
channel, and the detector has independent processing of the CO signal for the
CO alarm channel and CO signal for fire detection. The detector’s selectable
detection behavior of the CO alarm channel is regardless of ASA parameter sets
for fire detection.
AS technology™. For the automatically addressed detector bus C-NET collective
/ conventional (OOH740 only)
- Signal processing with ASAtechnology
- Event-controlled detection behavior
- Evaluation of the criteria heat, warmth for OOH740, and gas for OOHC740
- Quick response to all fires that generate carbon monoxide (CO) for OOHC740
- Separate detection of toxic CO for OOHC740
- Highly developed immunity to deceptive phenomena
- Prepared for future requirements thanks to its programmability
- Address automatically issued during commissioning
- Supports disturbance-free function testing with DFTtechnology™ (Disturbance-Free Test) (OOH740)
Properties
Design
Resistant to environmental and interfering influences such as dust, fibers, insects, moisture, extreme temperatures, electromagnetic interference, corrosive vapors, vibration, artificial aerosols, and atypical fire phenomena
Features
- Shock resistant, protection against sabotage
- Signal processing with AS technology (Advanced Signal Analysis)
- Time and process-dependent detection behavior
- High degree of immunity to faults in power electronics
- Protected electronics, high-quality components
- Sophisticated sensors and electronic monitoring
- The integrated line separator that locates the defective part on the detector bus of the control panel and isolates between two detectors
- Supports automatic detector test with DFTtechnology™ (OOH740)
- Integrated alarm indicator (AI), 360° visibility
- Up to two external alarm indicators can be connected per detector
- Address automatically issued during commissioning
- Same detector base can be used for every detector type, for surface-mounted and recess-mounted supply lines
- OOH740 only: Can also be used on a collective detector line or a conventional detector line
Eco-friendly
- Environmentally friendly processing
- Reusable materials
- Electronic parts and synthetic materials can be easily separated
Use
OOH740 multi-sensor fire detector, neural ASA
| Multi-sensor fire detector consisting of:
- Point detector
- Detector dust cap to protect the point detector during the construction phase
Function:
- Functions according to the scattered light principle with two sensors, optical forward and backward scattering
- Opto-electronic measuring chamber that obstructs disruptive extraneous light but provides excellent detection of both light and dark smoke particles
- Two additional heat sensors increase the point detector’s immunity to deceptive phenomena
- Can be set as a multi-sensor smoke detector, smoke detector, or heat detector by the software
- Selectable detection behavior thanks to application-specific ASA parameter sets
Use :
- For early detection of flaming fires of solid and liquid substances, as well as of smoldering fires
- For early and reliable fire detection in an environment with deceptive phenomena
- Can be used on an addressed detector line, a collective detector line, or a conventional detector line
OOHC740 fire and CO detector, neural ASA
| Multi-sensor fire detector consisting of:
- Point detector
- Detector dust cap to protect the point detector during the construction phase
Function:
- Functions according to the scattered light principle with two sensors, optical forward and backward scattering
- Opto-electronic measuring chamber that obstructs disruptive extraneous light but provides excellent detection of both light and dark smoke particles
- Two additional heat sensors and an additional CO sensor increase the point detector’s response behavior and immunity to deceptive phenomena
- Technical message, ambient supervision: Technical message if the temperature or CO concentration exceeds/falls below the preset limits
- Functions using an electro-chemical CO cell
- CO concentration alarm is transmitted to an independent technical CO alarm channel
- Independent processing of the CO signal for the CO alarm channel and CO signal for fire detection
- Selectable detection behavior of the CO alarm channel, regardless of ASA parameter sets for fire detection
- Selectable detection behavior thanks to application-specific ASA parameter sets
Use :
- For early detection of smoldering fires that generate CO (e.g., mattress fires in homes)
- Areas with increased CO exposure, e.g., heating rooms, combustion plants, fermentation plants, garages, automotive workshops, animal stalls, chemical laboratories, or production sites
- For reliable fire detection in an environment with deceptive phenomena
- Can be used addressed
Detector base DB721
| Function:
- Universal base for all point detectors of the Cerberus™ PRO FD720 series
Use :
- For recess-mounted supply lines
- For surface-mounted supply lines with cables up to max. Ø 8 mm
The detector base DB721 has a loop contact. When using the DB721, the detector line is also not interrupted when there is no point detector mounted in the detector base.
Detector base DB721D
| Function:
- Collective mode
- Universal base for the point detector OOH740 in collective mode (with BS 5839-1)
- Addressed mode
- Universal base for the point detector OOH740 of the Cerberus™ PRO FD720 series
- When used in the addressed mode, the diode must be removed
Use :
- For recess-mounted supply lines
- For surface-mounted supply lines with cables up to max. Ø 8 mm
The detector base DB721D has a loop contact. When using the DB721D, the detector line is also not interrupted when there is no point detector mounted in the detector base.
Detector base DB722
| Function:
- Universal base with base seal for point detectors OH720 and OP720 of the Cerberus™ PRO FD720 series
Use :
- For recess-mounted supply lines
- For surface-mounted supply lines with cables up to max. Ø 8 mm
The detector base DB722 has a loop contact. When using the DB722, the detector line is also not interrupted when there is no point detector mounted in the detector base.
Detector base DB110 (parameter set 1)
| Function:
- Universal base for all point detectors of the 110 and OOH740 series
- Selects parameter set 1 within the point detector
Use :
- For recess-mounted supply lines
- For surface-mounted supply lines with cables up to max. Ø 8 mm
Sounder base DBS720
| Function:
- Addressable sounder base for the acoustic alarm
- Compatible with all point detectors from the Cerberus™ PRO FD720 series You will find more information on the sounder base DBS720 in document A6V10218037.
Intended Use
The automatic fire detectors OOH740 and OOHC740 may only be used on a C-NET
detector line in a fire detection system FS720 or FC360.
The automatic fire detector OOH740 may also be used on a collective detector
line or a conventional detector line.
Type Overview
Type | Designation | Order number | Weight [kg] |
---|---|---|---|
OOH740 | Multi-sensor fire detector, ASA | S54320-F7-A3 | 0.124 |
OOHC740 | Fire and CO detector, ASA | S54320-F8-A3 | 0.128 |
DB721 | Detector base with loop contact | S54319-F11-A1 | 0.052 |
DB721D | Detector base with loop contact | S54319-F15-A1 | 0.054 |
DB722 | Detector base | S54319-F19-A1 | 0.052 |
DB110 | Detector base (collective) | S54372-F5-A1 | 0.052 |
DBS720 | Sounder base | S54319-F5-A1 | 0.090 |
Accessories
BA720| Base attachment| S54319-F20-A1| 0.051
BA721| Base attachment wet| S54319-F29-A1| 0.272
FDBZ291| Designation plate| A5Q00002621| 0.002
DBZ1193A| Designation plate| BPZ:4864330001| 0.076
RS720| Detector base seal| S54319-F8-A1| 0.012
LP720| Detector locking device| S54319-F9-A1| 0.001
FDBH291| Detector heating unit| A5Q00004439| 0.015
DBZ1194| Protective cage| BPZ:4677110001| 0.138
DBZ1190-AA| Micro terminal 0.28…0.5 mm²| BPZ:4677080001| 0.001
DBZ1190-AB| Connection terminals 0.5…2.5 mm²| BPZ:4942340001| 0.001
PSR720-1| Parameter set resistor 33k| S54319-F16-A1| 0.001
PSR720-2| Parameter set resistor 68k| S54319-F17-A1| 0.001
Accessories
Base attachment BA720
| Function:
- For routing surface-mounted ducts (max. 20 mm) and cable ducts (max. 25 x 15 mm)
- Detector base mounted quickly: The detector base clicks into place in base attachment BA720.
Base attachment wet BA721
****|
- Base attachment wet with additional integrated rubber seal for mounting in wet or humid environments
- For achieving a higher protection category
- For mounting in wet or humid environments
- Required when using detector heating unit FDBH291
- Required when using protective cage DBZ1194
- Mounted between detector base and ceiling
- Detector base mounted quickly: The detector base simply clicks into place in base attachment wet BA721.
Protective cage DBZ1194
|
- To protect the point detector from damage
- Can only be mounted in combination with base attachment wet BA721
Detector heating unit FDBH291
|
- For operating point detectors in critical ambient conditions during icy conditions or when there is a danger of moisture condensation. Examples of application: Cold stores, attics, loading ramps, cheese cellars
- Optimum function is only guaranteed in conjunction with base attachment wet BA721.
- The point detector temperature increases by approximately 2 °C over the operating temperature and thus avoids moisture condensation on the detector.
- Mounted quickly: The detector heating unit clicks into place in the detector base.
Designation plate FDBZ291
|
- For labeling with the location address
- Can only be used without detector base seal FDBZ295
Designation plate DBZ1193A
|
- For labeling with the location address
- Can only be used with base attachment wet BA721
Detector base seal RS720
|
- For achieving a higher IP protection category
- Mounted between detector base and ceiling
Detector locking device LP720
|
- For protection against theft of the point detector
- Set screw M3 x 12 mm prevents the point detector being unscrewed from the detector base
- Point detector can only be removed with the appropriate Allen key
Parameter set resistor 33k PSR720-1
| Function:
- Prefabricated resistor with flat plugs for use in DB110 and DB721D. Brings the OOH740 in parameter set 1.
Parameter set resistor 68k PSR720-2
| Function:
- Prefabricated resistor with flat plugs for use in DB110 and DB721D. Brings the OOH740 in parameter set 2.
DBZ1190-AA micro terminal and DBZ1190-AB connection terminal
|
- Micro terminal DBZ1190-AA
- Cable cross section up to max. 0.5 mm²
- Connection terminal DBZ1190-AB
- Cable cross section up to max. 2.5 mm²
- For connecting two external alarm indicators or the cable shielding
Product documentation
Document ID | Title |
---|---|
008115 | Installation Detector heating FDBH291 |
A6V10200373 | Installation Detector base with loop contact DB721, DB722, |
detector base DB720, sounder base DBS720, detector base seal RS720, detector
locking device LP720, base attachment BA720
A6V10203222| Data Sheet Testequipment and accessories FDUL221, DX791, RE6,
RE7T, RE8ST, RE8STCO, FDUM29x, LE3, StabexHF
A6V10218037| Technical Manual Sounder base DBS720
A6V10229261| List of compatibility (for ‘Cerberus™ PRO’ product line)
A6V10305793| Technical Manual Automatic fire detectors OOH740, OOHC740
A6V10393192| List of compatibility (for ‘Cerberus™ FIT’ product line)
A6V10406006| Installation Base attachment wet BA721, Detector designation
plate DBZ1193A, Protective cage DBZ1194, EMC-protective cage FDBZ294
A6V10882301| List of compatibility (for ‘FC360’ product line)
Notes
Installation
Easy mounting
-
Universal detector base
-
Two break-out points for surface-mounted cable entry at the side.
Max. cable diameter: 8 mm. -
Extra-large opening for single recess-mounted cable entry.
-
-
Extra-long mounting slits allow existing drill holes from other systems to be reused.
-
Screw terminals for conductors up to max. 1.6 mm²
-
Space for auxiliary terminals:
- 2x micro terminals DBZ1190-AA and
- 2x connection terminals DBZ1190-AB
The detector can be screwed into the base easily either manually or using the
detector exchanger DX791 and the corresponding adapter FDUD491.
The internal alarm indicator is centered in the detector, which makes
alignment of the point detector superfluous.
1 | Detector base | 5 | Mounting slits |
---|---|---|---|
2 | Auxiliary terminals DBZ1190‑AA, DBZ1190‑AB | 6 | Point detector |
3 | Screw terminals for detector line and external alarm indicator | 7 | Internal |
alarm indicator
4| Opening for cable entry| |
Disposal
The device is considered an electronic device for disposal in accordance with European Directive and may not be disposed of as domestic waste.
- Use only designated channels for disposing the devices.
- Comply with all local and currently applicable laws and regulations.
- Dispose of empty batteries at designated collection points.
Technical data
| OOH740| OOHC740
---|---|---
Operating voltage (modulated)| DC 12…33 V| DC 12…33 V
Operating current (quiescent)| ~170…250 µA| ~300…380 µA
Max. number of external alarm indicators that can be connected| 2| 2
Operating temperature| -25…+55 °C| -10…+50 °C
Storage temperature| -30…+70 °C| -20…+55 °C
Air humidity (short-term moisture condensation permitted)| ≤95 % rel.| ≤95 %
rel.
Communication protocol| C-NET, collective or conventional| C-NET
Color| ~RAL 9010 pure white| ~RAL 9010 pure white
Weight| 0.100 kg| 0.100 kg
Protection category (IEC 60529)| IP40| IP40
Protection category (IEC 60529) with detector base seal RS720/BA721| IP44|
IP44
Standards| EN 54‑5, EN 54‑7, EN 54‑17,| EN 54-5, EN 54-7, EN 54-17,
| EN 54‑29| EN 54-29
| | Fulfills the requirements
| | according to EN 54-31
Approvals| |
VdS| G211070| G211047
LPCB| 126bv/04| 126bv/08
FM| 3051081| –
DNV GL (marine)| MEDB00003UK| –
Permissible wind speed| Max. 5 m/s| Max. 5 m/s
C-NET system compatibility| FC720, FC360
Collective system compatibility| FC10/FC120| –
Dimensional drawings
- OOH740
- OOHC740
- OOH740 with base DB72x or DB110
- OOHC740 with base DB72x
Issued by
Siemens Switzerland Ltd
Smart Infrastructure
Global Headquarters
Theilerstrasse 1a
CH-6300 Zug
+41 58 724 2424
www.siemens.com/buildingtechnologies
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>