CHARACTERISTICS

Electrical Characteristics

  • External power supply with 100/240VAC – 5A at 24V
  • Fuse protection 3.15A

Electronic Characteristics

  • Photocell to detect label presence
  • Tachometer to control the label length
  • Display with 2 lines of 16 characters

Electrical Characteristics

  • Personalization of company name
  • Photocell function control
  • Programmable quantity of labels to detach from 0 to 999
  • Continual display of the detached label quantity
  • Continual display of the number of detached label series
  • Programmable length of detached part of label
  • Three different feed types
  • Acoustic alarm sounds when the number of label series reaches the programmed quantity
  • Programmable series from 2 to 3 labels of different lengths

Mechanical Characteristics

  • Maximum dimensions
    DN01 and DN02: W=330mm (12.99”); H=240mm (9.45”); D=410mm (16.14”)
    DP02: W=320mm (12.60”); H=210mm (8.26”); D=260mm (10.24”)
    DP03: W=240mm; H=210mm (8.26”); D=260mm (10.24”)

  • Speed 120 rpm

  • Roll diameter up to 300mm (11.81”) (DN01 – DN02) or 200mm (7.87”) (DP02 – DP03)

  • Core holder from 30mm (1.18”)

  • Label width up to 70mm (2.75”) (DP03), 150mm (5.90”) (DN01 – DP02) or 210mm (8.26”) (DN02)

  • Table to write on label if required before removal

  • Mechanical regulation of the clutch

PROGRAMMING

Exiting Menu
IMPORTANT
To exit at any moment from the programming mode and implement an alarm reset, push this button.
When first switched on the panel will display the following:

D P R DN01 Label dispenser - fig

Enable First Menu
Push this button to enter into the program mode and the panel will indicate that you wish to detach one series label at a time.

D P R DN01 Label dispenser - fig 2

Push this button again if you don’t want to select the series type and set the detached label length.
By successively pushing these buttons you can change the series from 1 to 3 labels. Even if they are of different sizes but are part of a single series the panel will display it:

D P R DN01 Label dispenser - fig 3

  Having established the type of series to use, when pushing these buttons for each type of label, it is possible to modify the length of the label section that needs to be  detached for each single label. The panel will then display on the following three types of messages.

D P R DN01 Label dispenser - fig 4

Enable Second Menu
  By successfully pushing these buttons you can choose three different feed types.

D P R DN01 Label dispenser - fig 5

 Temporized feed

This option allows the user to define the detach delay time from 1 to 60 seconds between labels.
To run this option please follow the next operation.

By successively pushing this button you enter in the setting seconds menu.

   By successfully pushing these button you can select the detach delay time from 1 to 60 seconds between labels.
Example: In this case you can detach a label every 15 seconds.

Automatic feed
This function dispenses the labels automatically.

Manual feed
This function dispenses the label only if you push the ESC button or the pedal (optional accessory).

IMPORTANT
In both cases the dispenser will be stopped if the counter function is active and you reach the set number of labels.

Enable Third Menu
By successfully pushing this button you can select the counter function that presets the number of labels to detach. The panel will then display the following two types of messages.

D P R DN01 Label dispenser - fig 10

Push this button to choose between having the counter function on or off.
When selecting “ACTIVE COUNTER YES” you can define the quantity of labels to detach and the panel will display the sequential counter with the option to select from 1 to 9999 labels or a series of labels to detach.

D P R DN01 Label dispenser - fig 11

By pushing these buttons you can select the 4 digits of the counter one at a time.
Once selected, the digit to be modified can be changed between a value from 0 to 9.

IMPORTANT
To ensure that the detached labels correspond to the number selected under the active counter menu YOU MUST push this button for a few seconds to reset the counter.

IMPORTANT
With the manual function Automatic feed ON, the counter reset will display “0001” because the first label available for detachment will be displayed.

NOTE:
During operation, once the last label that was programmed detaches the dispenser will stop and emit an acoustic warning signal. To turn off the alarm and reset the counter push this button.
When selecting “ACTIVE COUNTER NO” the counter is disabled and the labels can be detached with undefined quantities.

Enable Fourth Menu
By successfully pushing this button you can enable the function that allows the customers name to appear on the display.

  By pushing these buttons you can select the 16 digits of the counter one after another in order to insert the required text.
  Having selected the digit to program with these buttons, you can change the value with letters, numbers and symbols.

Enable Fifth Menu
By successfully pushing this button you enable the control of the sensor functions for label presence. All of the digits will be on, as shown below with the functioning sensors not in use.

D P R DN01 Label dispenser - fig 16

By covering the sensor next to the panel with a finger, the digits turn off. As shown in the following which demonstrates the use of the sensors by the label.

D P R DN01 Label dispenser - fig 17

MOTOR MANUAL ADVANCE

Press this key for manual advance of the motor.

COUNTER ZERO SETTING
Press this key for 4 seconds to reset the counter to 0. When reset the dispenser will emit a sound.

ROLL LOAD ON THE DISPENSER
Load the roll of labels on the hub. Tighten the roll by attaching the plate. The tighter the plate the more tension is applied to the roll.
Note: If during standard operation more than one label is detached pls increase the pressure on the plate springs.

D P R DN01 Label dispenser - fig 18

Follow the load procedure as seen below:
Open the drag roller and pass the backing through the rollers.

D P R DN01 Label dispenser - fig 19

Block the backing with the fork on the recovery roller. Close the drag roller.

D P R DN01 Label dispenser - fig 20

Push the displayed button to roll up the backing on the recovery roll.

D P R DN01 Label dispenser - fig 21

SENSOR CALIBRATION

IMPORTANT
The device is calibrated in our lab, please do the following operations only if necessary.
Without any label between the sensors, the digits on the display must be black.

D P R DN01 Label dispenser - fig 22

Put a label away from the plate 20mm, the digits on the display should be white; if not pls unscrew the sensor 2 and move it up or down to obtain this condition then tighten the screws.

D P R DN01 Label dispenser - fig 23

Smart solutions for the labeling industry

D P R DN01 Label dispenser - fig 24

– FOR MORE INFO CONTACT YOUR RESELLER –

Documents / Resources

| D P R DN01 Label dispenser [pdf] User Manual
DN01, DN02, DP03, DP02, DN01 Label dispenser, Label dispenser, dispenser
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

D P R User Manuals

Related Manuals