Miele TwoInOne Silence KMDA 7272/KM 7473 User Guide

June 11, 2024
Miele

Guide: How to change the TwoInOne Silence KMDA 7272/KM 7473
from U (recirculation) to A (vented) mode:

TwoInOne Silence KMDA 7272/KM 7473

From Plug&Play Recirculation mode to Vented mode

  1. Remove Plug&Play adapter (x)
  2. Put the activate charcoal filter aside (x)
  3. Install the KMDA with connection to exhaust air duct system – Miele Flat ducting set for vented mode can be used: DFKS-AR, mat.no 12226910. (+)
  4. Change programming P17 from C:00 to C:01 (Follow steps in user manual “Changing the programming”)

Miele TwoInOne Silence KMDA 7272 KM 7473

Miele. Immer Besser. Dept.

Documents / Resources

| Miele TwoInOne Silence KMDA 7272/KM 7473 [pdf] User Guide
KMDA 7272, KM 7473, TwoInOne Silence KMDA 7272 KM 7473, TwoInOne Silence, KMDA 7272 TwoInOne Silence, KM 7473 TwoInOne Silence, TwoInOne
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Miele User Manuals

Related Manuals