General information
Dear Customer.
Please read and comply with these original operating instructions and the
enclosed safety instructions. Proceed accordingly. Keep both booklets for
future reference or subsequent owners.
Proper use
This appliance has been designed for use in private households and is not
intended for commercial use.
The manufacturer is not responsible for any damages that may occur on account
of improper use or wrong operations. The device is meant for use as house
water tank. This unit is only to be used indoors.
Note The pump is not suited for increasing the existing line
pressure.
Approved fluids
- Used water
- Well water
- Water source
- Rain water
- Water from swimming pool (provided the dosing of additives is proper)
Environmental protection
The packaging material can be recycled.
Please do not place the packaging into the ordinary refuse for
disposal, but arrange for the proper recycling.
Old appliances contain valuable materials that can be recycled. Please
arrange for the proper recycling of old appliances. Please dispose your old
appliances using appropriate collection systems.
Notes about the ingredients (REACH) You will find current information about
the ingredients at: www.kaercher.com/REACH
Warranty
The warranty terms published by the relevant sales company are applicable in
each country. We will repair potential failures of your appliance within the
warranty period free of charge, provided that such failure is caused by faulty
material or defects in manufacturing. In the event of a warranty claim please
contact your dealer or the nearest authorized Customer Service centre. Please
submit the proof of purchase.
Operation
Description of the Appliance Illustration
- Backflow valve
- Connection adapter for pumps G1
- Stopper
- Connection G1(33.3mm) Suction pipe
- Filling nozzle
- Connection G1(33.3mm) Pressure pipe
- Carrying handle*
- Power switch*
- Air valve (Schrader valve) with cap
- Base with slotted hole for bolted connection
- Pressure display
- Drain screw
- Power cord with plug
-
only for BP 3 Home
Preparing the Appliance-
Check max. air pressure in the storage tank prior to commissioning. If necessary, refill up to 2.0 bar with a commercially available air pump with the system switched off / zero-pressure state.
-
Secure device against slipping off (fix it with screws, if needed).
-
Remove the plug.
-
Screw the connection adapter in the suction connection of the pump (inlet). Tighten manually.
-
Screw check valve onto connector adapter at the suction connection. Tighten manually.
-
Connect the vacuum-proof suction hose with integrated backflow stop on the suction side. (available as optional accessory)
-
Screw the connection adapter in the delivery connection of the pump (outlet). Tighten manually.
-
Connect delivery line. Illustration
-
Unscrew the lid of the filling nozzle and fill in water till it overflows.
-
Screw on the lid on the filling nozzle.
-
Open existing shutoff valves in the pressure pipe.
Note Even the smallest of leakage leads to malfunctioning. -
In case of leaks, seal all connections with a suitable sealant (e.g. Teflon tape) to prevent malfunction due to leakage or air intake.
-
Permanent installation
With a permanent installation the pump can be screwed onto a suitable surface.
- Use suitable screws to screw the bases onto a level surface. In case of a permanent installation the installation of a flexible component such as a flexible pressure compensating hose (see optional accessories) on the pressure side is recommended. This has the following benefits:
- More flexibility during set-up and installation.
- Noise reduction, since no vibrations are transferred to pipes.
- In case of small leaks, the pump does not switch as often.
Note To facilitate subsequent emptying and pressure release of the
system, we recommend the installation of a stopcock between pump and pressure
line. (not included in delivery) By closing the shut-off valve when emptying
the pump you can prevent water from escaping from the pressure line.
Operation
BP 3 Home:
- Insert the mains plug into the socket.
- Switch the appliance on at the appliance switch.
BP 5 Home:
- Insert the mains plug into the socket.
Note Pump starts running immediately.
Wait till the pump sucks in and pumps uniformly, then shut the gate valve in
the pressure pipe. The pressure switch deactivates the motor when the shut-off
pressure is reached. The storage boiler is now full; the domestic water supply
system is ready for operation.
If there is a lack of supplied water, the switch-off pres- sure is not
reached; the pressure switch cannot shut off the appliance. The water in the
pump head will then heat up. In case of overheating, the power supply is
interrupted by a thermal switch, to avoid damage to the pump from overheating.
The supply of power is switched back on after the appliance has cooled off.
Note The cooling down time until the motor starts up again can be up to
150 min. We recommend installing a dry run protection unit to regulate the
lack of water situation (see special accessories).
CAUTION System is under pressure! (For pressure details see chapter on
technical specifications)
Finish operation
BP 3 Home:
-
Switch the appliance off at the power switch.
-
Disconnect the main plug from the socket.
BP 5 Home: -
Disconnect the main plug from the socket.
Maintenance and Care
DANGER Turn off the appliance and remove the mains plug prior to any care and maintenance works. Care Open the connected shutoff valves to relief pressure and reclose them. The system is free of pressure.
- Rinse the pump after every use if you use to transport water with additives.
Maintenance
- Check the pressure of the air filling in the storage boiler every six months. If necessary, refill up to 2.0 bar in switched off / zero-pressure state (disconnect device, open the water cock). Illustration The air valve is located under the cover. Turn in anticlockwise direction to unscrew the cover.
Transport
CAUTION
In order to prevent accidents or injuries, keep in mind the weight of the
appliance during transport (see Specifications).
When transporting in vehicles
- Secure the appliance against shifting and tipping over.
Storage
CAUTION
In order to prevent accidents or injuries, keep in mind the weight of the
appliance when selecting a storage location for it (see Specifications).
Storing the Appliance
- Fully drain the appliance prior to storing it.
- Store the appliance in a frost free area.
Special accessories
The figures of the following special accessories can be found on page 4 of these instructions.
6.997-343.0| Pump pre-fitter, small (flow rate up to 4000 Vh)| Pump pre-filter
for all common pumps without integrated fitters. To protect the pump against
coarse dirt particles or sand. The fine filter can be washed. For pumps with
G1 (33.3 mm) connection thread.
---|---|---
6.997-344.0| Pump pre-filter, large (flow rate up to 6,000 I/h)| Pump pre-
filter for all common pumps without integrated fitters. To protect the pump
against coarse dirt particles or sand. The fine filter can be washed. For
pumps with G1 (33.3 mm) connection thread.
6.997-350.0| Suction assembly 3.5 m, 3/4″| Completely ready for connection,
vacuum-proof spiral hose with sucbon filter and backflow stop. Can also be
used as an extension for the suction hose. For pumps with G1 (33.3 mm)
connection thread.
6.997-349.0| Suction assembly 7.0 m, 3/4″
6.997-348.0| Suction hose 3.5 m, 3/4″| Completely ready for connection,
vacuum-proof spiral hose for direct connection to the pump. To extend the
suction assembly or for use with suction filters. For pumps with G1 (33.3 mm)
connection thread.
6.997-359.0| Pump connection G1 (33.3 mm) incl. Check valve| Vacuum-resistant
connection of the hoses to the pump.
For pumps with G1 (33.3 mm) connection thread and 3/4″ as well as 1″ hoses,
including union nut, hose clamp, flat packing and check valve.
ATTENTION
4 Do not install the check valve included in the set!
6.997-347.0| Vacuum-proof spiral hose, yard goods, 25 m, 3/4″| Vacuum-proof
spiral hose. Yard goods for cutting hoses to individual lengths. When combined
with the Karcher connection pieces and the Karcher suction filters, it can be
used as an individual suction assembly.
6.997-346.0| Vacuum-proof spiral hose, yard goods, 25 m, 1″
6.997-345.0| Suction fitter Basic 3/4″(19 mm)| To be connected to the suction
hose yard goods. The backflow stop prevents the return flow of the delivered
water and thus reduces the time required for suction to start again. Including
hose clamp.
6.997-342.0| Suction fitter with backflow stop, basic, 1″
6.997-341.0| Suction fitter with backflow stop, premium| To be connected to
the suction hose meter length. The backflow stop prevents the return flow of
the transported water and thus shortens the re-suction time.
Durable metal/plastic construction. Suitable for 3/4″ (19 mm) and 1″ (25.4 mm)
hoses.
Including hose clamp.
6.997-360.0| Suction hose for pipes 0.5 m, 3/4″| Vacuum-tight hose to reduce
noise with fixed installations. 1″(25.4 mm) hose with threaded connection
G1(33.3 mm) on both ends. Caution: The suction hose may not be used as a
pressure hose.
6.997-340.0| Connection kit Premium| For the connection of 3/4″ (19 mm) water
hoses to pumps with G1 (33.3 mm) connection threads. For increased water flow.
6.997-417.0| Pressure compensating hose 3/4″ (19mm), lm| Connecting hose for
the pressure compensation in the domestic water supply system. To connect the
pump to rigid pipe line systems. Furthermore, the internal storage volume in
the hose prevents frequent switching on and off of the pump.
G1 (33.3 mm) connection thread.
6.997-355.0| Dry run fuse| If no more water flows through the pump, the dry
run fuse will protect the pump from damage and automatically turn it off. With
G1″ (33.3 mm) threaded connection.
6.997-546.0| Dry run fuse
Type E (CEE7/5)
Country version BE, CZ, ES, FR, PL SK
Troubleshooting
**Danger**
To avoid risks, all repairs and replacement of spare parts may only be carried
out by authorized customer service personnel.
First pull out the plug from the mains before carrying out any tasks on the
machine.
Fault | Cause | Remedy |
---|---|---|
Pump runs but does not transport | Air in the pump | see chapter “Preparing the |
Appliance”
Air does not come out on the pressure side| Open tap on pressure side
No water available.| Check the water reservoir.
Pump does not run or suddenly comes to a standstill during oper- ations| Power
supply interrupted| Check fuses and electrical connections
Thermal protection switch in the motor has switched off the pump as it was
over- heated.| Pull out the mains plug, let the pump cool down, clean the
suction area, prevent dry running Note
The cooling down time until the motor starts up again can be up to 150 min.
Pump switches itself off and back on| Thermal protection fuse has switched the
pump off to protect from overheating or turned it back on after it has cooled
off.| In order to prevent a repetition, the system should be checked for leaks
and sealed.
Motor starts up immediately after switch off| Pressure is not retained in the
system| Check connections including sealings and control the water outlet.
The smallest of leakages can affect the operation adversely.
Air pressure in the storage boiler is too low.| Fill storage boiler with 2.0
bar. See chapter “Main-tenance”
Backflow valve does not close properly| Check backflow valve on suction side.
Membrane in pressure tank is defective| Replace membrane
Pump transports is reducing or transported quantity is too low| Suction filter
or check valve (special accessories) contaminated| Clean suction filter or
check valve (special accessories)
The quantity transported by the pump de- pends on the transport height and the
connected periphery| Keep max. flow height, see technical data. If necessary,
select a different hose diameter or hose length.
Vibrating sound while taking out water| Membrane in pressure tank vibrates|
Noise caused by operations and the noise can be reduced by reducing the
pressure in the air filling of the storage tank.
Our Kircher branch will be pleased to help you further in the case of questions or faults. See address on the reverse.
Technical specifications
| | | BP 3 Home| | BP 5 Home
---|---|---|---|---|---
Voltage| V| | 230| | 230|
Frequency| Hz| | 50| | 50|
Output P„,,,,| W| | 800| | 1100|
Max. flow rate| lih| | 3000| | 4500|
Max. Suction height| m| | 7| | 8|
Max. pump pressure| MPa (bar)| | 0,36 (3,6)| | 0,5 (5,0)|
Working pressure| MPa (bar)| 0,17| – 0,28 (1,7 – 2,8)| 0,19| – 0,3 (1,9| –
3,0)
Max. air pressure in the storage tank| MPa (bar)| 0,18| – 0,2 (1,8 – 2,0)|
0,18| – 0,2 (1,8| – 2,0)
Max. permissible internal pressure in the storage tank| MPa (bar)| | 0,50
(5,0)| | 0,50 (5,0)|
Weight| kg| | 11,5| | 14,7|
Subject to technical modifications!
Operating pressure and transported quantity depends on the suction height and
the connected periphery!The possible delivery rate is even larger:
- the lower the suction and flow heights
- the larger the diameter of the hoses used,
- the shorter the hoses used are
- the lower the pressure loss caused by the connected accessories
http://www.kaercher.com/dealersearch
Alfred Kärcher GmbH & Co. KG
Alfred-Kärcher-Str. 28 – 40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212 http://kaer.ch/er/?l=TwSoJtl9IUOwZyAe1rHDyw