GE-DP 7330 L Dirty Water Pump
Instruction Manual GE-DP 7330 LL
GE-DP 5220 LL
Original operating instructions
Dirty Water Pump
Art.-Nr.: 41.707.90
Art.-Nr.: 41.707.80
I.-Nr.: 11013
I.-Nr.: 11013
GE-DP 7330 L Dirty Water Pump
Telefon: 09951 / 95 920 00 ·Telefax: 09951/95 917 00
E-Mail: info@einhell.de · Internet: www.isc-
gmbh.info
iSC GmbH · Eschenstraße 6 · 94405 Landau/Isar (Deutschland)
Danger! – Read the operating instructions to reduce the risk of inquiry
This equipment can be used by children of 8 years and older and by people with
limited physical, sensory or mental capacities or those with no experience and
knowledge if they are supervised or have received instruction in how to use
the equipment safely and understand the dangers which result from such use.
Children are not allowed to play with the equipment. Unless supervised,
children are not allowed to clean the equipment and carry out user-level
maintenance work.
If the power cable for this equipment is damaged, it must be replaced by the
manufacturer or its after-sales service or similarly trained personnel to
avoid danger.
Danger!
When using the equipment, a few safety precautions must be observed to avoid
injuries and damage. Please read the complete operating instructions and
safety regulations with due care. Keep this manual in a safe place, so that
the information is available at all times. If you give the equipment to any
other person, hand over these operating instructions and safety regulations as
well. We cannot accept any liability for damage or accidents which arise due
to a failure to follow these instructions and the safety instructions.
Safety regulations
Danger!
Read all safety regulations and instructions.
Any errors made in following the safety regulations and instructions may
result in an electric shock, fire and/or serious injury.
Keep all safety regulations and instructions in a safe place for future use.
Danger!
The pump must be powered via an earth-leakage circuit breaker (RCD) with a
rated fault current of no more than 30 mA (according to VDE 0100 Part 702 and
738).
The equipment is not designed for use in swimming pools and paddling pools of
any kind or other bodies of water in which people or animals may be present
during operation.
It is prohibited to operate the equipment if a person or animal is in the
danger area. Ask your electrician!
- Before you put the equipment into operation, arrange for a specialist to check that the earthing, protective multiple earthing or residual-current operated circuit-breaker circuit comply with the safety regu lations of the power supply company and work correctly.
- The electrical plug-in connections must be protected from wet conditions.
- If there is a risk of flooding, place the plug-in connections in an area which is safe from flooding.
- Strictly avoid pumping aggressive liquids and abrasive substances.
- Protect the equipment from frost.
- Protect the equipment from dry running.
- Take suitable measures to keep the equipment out of the reach of children.
- There is a risk of the liquid becoming contaminated by escaping lubricant.
Layout and items supplied
2.1 Layout (Fig. 1/2)
- Universal hose connection
- Floating switch
- Screw for height adjustment
- Intake cage
- Handle
- Suspension eye
2.2 Items supplied
Please check that the article is complete as specified in the scope of
delivery. If parts are missing, please contact our service center or the sales
outlet where you made your purchase at the latest within 5 working days after
purchasing the product and upon presentation of a valid bill of purchase.
Also, refer to the warranty table in the service information at the end of the
operating instructions.
- Open the packaging and take out the equipment with care.
- Remove the packaging material and any packaging and/or transportation braces (if available).
- Check to see if all items are supplied.
- Inspect the equipment and accessories for transport damage.
- If possible, please keep the packaging until the end of the guarantee period.
Danger!
The equipment and packaging material are not toys. Do not let children play
with plastic bags, foils or small parts. There is a danger of swallowing or
suffocating!
- Dirty water pump
- Universal hose connection
- Original operating instructions
Proper use
The equipment you have purchased is designed to pump water with a maximum
temperature of 35 °C. This equipment must never be used for other liquids,
especially not for engine fuels, cleaning agents and other chemically-based
products!
Before you use the pump, clarify any possible special conditions which need to
be fulfi lled for the installation!
For example, additional safety measures may be needed if damage to property
could result from a power failure, soiling or a defective gasket.
Examples of such safety measures:
Pumps running in parallel on a separately protected power circuit, moisture
sensors for switching off the pumps, and similar safety arrangements. Be sure
to consult a professional plumber if you have any doubt.
The equipment can be used wherever you want to move water, e.g. in the house,
in the garden, and for many other applications. It must not be used to operate
swimming pools!
If you want to use the equipment in bodies of water with a natural, muddy
bottom, place the equipment in a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous operation, e.g. as a circulating
pump in a pond. In this case the equipment’s anticipated life will be greatly
shortened because the equipment was not designed for continuous loading.
The equipment is to be used only for its prescribed purpose. Any other use is
deemed to be a case of misuse. The user / operator and not the manufacturer
will be liable for any damage or injuries of any kind caused as a result of
this. Please note that our equipment has not been designed for use in
commercial, trade or industrial applications. Our
warranty will be voided if the machine is used in commercial, trade or
industrial businesses or for equivalent purposes.
The water may be contaminated by escaping lubricating oil/lubricant.
Technical data
GE-DP 7330 LL
Mains connection ……………………. 230 V ~ 50 Hz
Power consumption ……………………………. 730 W
Max. pumping rate …………………………..16500 l/h
Max. delivery head ………………………………. 8.5 m
Max. immersion depth …………………………….. 8 m
Max. water temperature ………………………… 35°C
Hose connection: .. approx. 47.8 mm (G 1½ ) AG
Max. size of foreign bodies: ……………….Ø 30 mm
Switching point height: ON ….max. approx. 60 cm
Switching point height: OFF …..min. approx. 5 cm
Suction height: ……………………………… min. 1 mm
Protection ……………………………………………..IPX8
GE-DP 5220 LL
Mains connection ……………………. 230 V ~ 50 Hz
Power consumption ……………………………. 520 W
Max. pumping rate …………………………..13500 l/h
Max. delivery head ………………………………. 7.5 m
Max. immersion depth …………………………….. 8 m
Max. water temperature ………………………… 35°C
Hose connection: .. approx. 47.8 mm (G 1½ ) AG
Max. size of foreign bodies: ……………….Ø 20 mm
Switching point height: ON ….max. approx. 60 cm
Switching point height: OFF …..min. approx. 5 cm
Suction height: ……………………………… min. 1 mm
Protection ……………………………………………..IPX8
Before starting the equipment
Before you connect the equipment to the mains supply make sure that the data
on the rating plate are identical to the mains data.
5.1 Installation
The equipment can be installed either:
-
Stationary with a rigid pipe line
or -
Stationary with a flexible hose line
The equipment must be fastened to the suspension eyelet with a rope (Fig.
2/Item 6).
The maximum pumping rate is possible only with the largest possible line
diameter; if smaller hoses or pipes are connected, the pumping rate will be
reduced. If the universal hose connection (Fig. 1/ Item 1) is used, it should
be shortened (as shown in Fig. 9) to the connection actually used in order not
to reduce the pumping rate unnecessarily.
Flexible hoses must be fastened to the universal hose connection with a hose
clip (not included in the scope of supply).
Note!
When installing, never hang the equipment by the discharge line or by the
power cable. The equipment must be hung up by the provided carry handle or
suspension eyelet, or it must rest on the bottom of the shaft. To ensure that
the equipment works properly, the bottom of the shaft always must be free of
sludge and other accumulations of dirt. If the water level is too low, the
sludge in the shaft can quickly dry out and hinder the equipment from
starting. It is necessary therefore to check the equipment regularly (carry
out trial start-ups).
The pump shaft should measure at least 50 x 50 x 50 cm so that the fl oating
switch can move freely.
5.2 Mains connection
Danger!
The equipment you have purchased comes with an earthing-pin plug. The
equipment is designed for connection to a socket outlet with earthing contact
for 230 V ~ 50 Hz. Make sure that the socket-outlet is suffi ciently fused (at
least 6 A) and in good working order. Insert the power plug in the socket-
outlet and the equipment is ready for operation.
Danger!
To rule out danger, this work must be left strictly to a specialist
electrician or Customer Service.
Operation
You can put the equipment into operation after you have thoroughly read the installation and operating instructions. Pay attention to the following points:
- Make sure that the equipment is set up securely.
- Check that the discharge line is fitted correctly.
- Make sure that the electrical connection is 230 V ~ 50 Hz.
- Check that the electrical socket-outlet is in good working order.
- Make sure that no moisture or water can ever reach the power connection.
- Make sure that the equipment does not run dry.
- To switch off the equipment, pull the power plug out of the socket outlet.
Setting the On/Off switching point:
The ON/OFF switching point can be infi nitely adjusted with the height
adjustment facility. For this purpose you must first slacken the screw (Fig. 3,
Item 3). The switching differential can be infi nitely adjusted by extending or
shortening the float cable (Fig. 3).
-
The floating switch must be fitted so that the switching point height: ON and the switch point height: OFF can be reached easily and with little force. Check this by placing the equipment in a container filled with water and carefully raising and lowering the floating switch with your hand. You can then see whether the equipment switches on and
off. -
Make sure that the distance between the floating switch head and the cable holder is not too smaller than 10 cm (Fig. 3). If the distance is too small, there is no guarantee that the equipment will work correctly.
-
When adjusting the floating switch, make sure that the floating switch does not touch the bottom before the equipment is switched off. Important! Risk of dry running.
Manual operation:
Mount the floating switch as illustrated in Fig. 1. The equipment will then run
continuously. To prevent dry running, this operating mode is allowed only
under supervision.
The equipment must be switched off (pull out the power plug) as soon as no more
water is emitted from the discharge line.
Dirty water mode (Fig. 4/5):
- Turn the equipment counter-clockwise up as far as the stop (Fig. 4/5).
Shallow suction mode (Fig. 5):
- Turn the equipment clockwise down as far as the stop (Fig. 5).
- In shallow suction mode, water can be sucked up down to a level of 1 mm.
- Only clean water can be sucked up in shallow suction mode.
Please note:
For the equipment to suck up water in shallow suction mode there must be a
minimum depth of 10 mm of water.
Replacing the power cable
Danger!
If the power cable for this equipment is damaged, it must be replaced by the
manufacturer or its after-sales service or similarly trained personnel to
avoid danger.
Cleaning, maintenance and ordering of spare parts
Danger!
Always pull out the mains power plug before starting any cleaning work.
8.1 Cleaning
- Keep all safety devices, air vents and the motor housing free of dirt and dust as far as possible. Wipe the equipment with a clean cloth or blow it with compressed air at low pressure.
- We recommend that you clean the device immediately each time you have finished using it.
- Clean the equipment regularly with a moist cloth and some soft soap. Do not use cleaning agents or solvents; these could attack the plastic parts of the equipment. Ensure that no water can seep into the device. The ingress of water into an electric tool increases the risk of an electric shock.
8.2 Cleaning the intake cage and pump housing (Fig. 5/6/7/8):
- Screw out the three screws (Fig. 6/Item B) counter-clockwise.
- Turn the equipment up as far as the stop (Fig. 5). Note the position of the lug (Fig. 5/Item A) and remove the intake cage (Fig.7/Item 4).
- Clean the intake cage (Fig. 7/Item 4) and the pump impeller housing (Fig.7/Item C) with clean water.
- Assemble in reverse order.
- When assembled, the lug must be in the correct position (Fig. 8/Item A).
8.3 Maintenance
There are no parts inside the equipment which require additional maintenance.
8.4 Ordering replacement parts:
Please quote the following data when ordering replacement parts:
- Type of machine
- Article number of the machine
- Identification number of the machine
- Replacement part number of the part required
For our latest prices and information please go to www.isc- gmbh.info
Disposal and recycling
The equipment is supplied in packaging to prevent it from being damaged in transit. The raw materials in this packaging can be reused or recycled. The equipment and its accessories are made of various types of material, such as metal and plastic. Never place defective equipment in your household refuse. The equipment should be taken to a suitable collection center for proper disposal. If you do not know the whereabouts of such a collection point, you should ask in your local council offices.
Storage
Store the equipment and accessories in a dark and dry place at above freezing temperature. The ideal storage temperature is between 5 and 30 °C. Store the electric tool in its original packaging.
Troubleshooting guide
Faults | Cause | Remedy |
---|---|---|
The equipment does not start | – Power supply not connected – Floating switch | |
does trigger | – Check power supply |
– Raise position of floating switch
The equipment
does not pump| – Intake sieve clogged
– Discharge hose kinked| – Clean intake sieve with water jet
– Unkink the hose
The equipment does not cut out| – Floating switch cannot sink| – Place
equipment correctly on shaft bottom
Insufficient pumping rate| – Intake sieve clogged
– Performance reduced due to heavily contaminated and abrasive water
impurities| – Clean intake sieve
– Clean equipment and replace wear parts
The equipment swit- ches off after briefly running| – Motor circuit-breaker
switches the equipment off due to excessive water contamination
– Water temperature too high; motor circuit-breaker switches the equip- ment
off| – Unplug power plug and clean equipment and shaft
– Ensure that maximum permissible water temperature (35 °C) is not exceeded
For EU countries only
Never place any electric power tools in your household refuse.
To comply with European Directive 2012/19/EC concerning old electric and
electronic equipment and its implementation in national laws, old electric
power tools have to be separated from other waste and disposed of in an
environment-friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the return request:
As an alternative to returning the equipment to the manufacturer, the owner of
the electrical equipment must make sure that the equipment is properly
disposed of if he no longer wants to keep the equipment.
The old equipment can be returned to a suitable collection point that will
dispose of the equipment in accordance with the national recycling and waste
disposal regulations. This does not apply to any accessories or aids without
electrical components supplied with the old equipment.
The reprinting or reproduction by any other means, in whole or in part, of
documentation and papers accompanying products is permitted only with the
express consent of the iSC GmbH.
Subject to technical changes
Service information
We have competent service partners in all countries named on the guarantee
certifi cate whose contact details can also be found on the guarantee certifi
cate. These partners will help you with all service requests such as repairs,
spare and wearing part orders or the purchase of consumables.
Please note that the following parts of this product are subject to normal or
natural wear and that the following parts are therefore also required for use
as consumables.
Category | Example |
---|---|
Wear parts* | Impeller |
Consumables* | |
Missing parts |
-
Not necessarily included in the scope of delivery!
In the eff ect of defects or faults, please register the problem on the internet at www.isc-gmbh.info. Please ensure that you provide a precise description of the problem and
answer the following questions in all cases:- Did the equipment work at all or was it defective from the beginning?
- Did you notice anything (symptom or defect) prior to the failure?
- What malfunction does the equipment have in your opinion (main symptom)? Describe this malfunction.
Warranty certificate
Dear Customer,
All of our products undergo strict quality checks to ensure that they reach
you in perfect condition. In the unlikely event that your device develops a
fault, please contact our service department at the address shown on this
guarantee card. You can also contact us by telephone using the service number
shown.
Please note the following terms under which guarantee claims can be made:
-
These guarantee conditions regulate additional guarantee services. Your statutory guarantee claims are not aff ected by this guarantee. Our guarantee is free of charge to you.
-
Our guarantee only covers defects suff ered by the device which have been verifi ably caused by a material or manufacturing fault and is limited to the rectifi cation of such defects or the replacement of the device at our discretion. Please note that our devices are not designed for use in commercial, trade or professional applications. A guarantee contract will not be created if the device has been used by commercial, trade or industrial business or has been exposed to similar stresses during the guarantee period.
-
The following are not covered by our guarantee:
– Damage to the device caused by a failure to follow the assembly instructions or due to incorrect installation, a failure to follow the operating instructions (for example connecting it to an incorrect mains voltage or current type) or a failure to follow the maintenance and safety instructions or by exposing the device to abnormal
environmental conditions or by lack of care and maintenance.
– Damage to the device caused by abuse or incorrect use (for example overloading the device or the use or unapproved tools or accessories), ingress of foreign bodies into the device (such as sand, stones or dust, transport damage), the use of force or damage caused by external forces (for example by dropping it).
– Damage to the device or parts of the device caused by normal or natural wear or tear or by normal use of the device. -
The guarantee is valid for a period of 24 months starting from the purchase date of the device. Guarantee claims should be submitted before the end of the guarantee period within two weeks of the defect being noticed. No guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains applicable to the device even if repairs are carried out or parts are replaced. In such cases, the work performed or parts fitted will not result in an extension of the guarantee period, and no new guarantee will become active for the work performed or parts fitted. This also applies if an on-site service is used.
-
Please report the defective device on the following internet address to register your guarantee claim: www.isc-gmbh.info. If the defect is covered by our guarantee, then the item in question will either be repaired immediately and returned to you or we will send you a new replacement device.
Of course, we are also happy off er a chargeable repair service for any defects
which are not covered by the scope of this guarantee or for units which are no
longer covered. To take advantage of this service, please send the device to
our service address.
Also refer to the restrictions of this warranty concerning wear parts,
consumables and missing parts as set out in the service information in these
operating instructions.
ISC GmbH · Eschenstraße 6 · D-94405 Landau/Isar
**** explains the following conformity according to EU directives and norms
for the following product