Paul Neuhaus Q-CCT Remote Control Instruction Manual

June 4, 2024
Paul Neuhaus

CCT

Q®-CCT Remote Control (Q-RC)

How it works

Status LED
Flashes ten times after the battery is inserted and signals successful initialisation.

On/Off button

For switching lighting groups on and off and for confirming programming entries / changes. After being switched off via the Q-RC, the Q products are in standby mode (power consumption < 0.5 kWh/1000h).

+/– brightness buttons

To smoothly adjust brightness, hold down until the appropriate level is reached.
+ button: light gets brighter. – button: light gets darker. A short tap on the + or – button makes the Q product brighter or darker in set increments (10% steps).

5000 – 2700 Kelvin light colour wheel

Daylight / neutral light / warm white light control (CCT); smooth nuances via touch control.

W button

For resetting to neutral white light / 3500 Kelvin

1 | 2 | 3 group buttons

Via the group buttons you can assign in total up to 20 Q lights / bulbs to the three groups and have the unit store the settings. Any given light can also be assigned to more than one group.

By pressing button 1, 2 or 3, you select the relevant group and by pressing. e.g. the On/Off button the selected group’s Q products get switched on or off, by pressing the brightness button they get dimmed and via the colour circle they have their colour controlled.

P button

By repeated pressing, smoothly set light colour of 2700/3500/4000 or 5000 Kelvin.

A 5000 Kelvin /daylight
B 2700 Kelvin / warm white
C 3500 Kelvin
D 4000 Kelvin / neutral white

A | Starting to use the

1. Switch on only the Q lights / bulbs that you want to pair. Please switch off any other Q products manually.

2. Hold the Q-RC right up close to the Q product’s receiver / to the Q bulb and hold e.g. the first group button down for c. 5 seconds until the status LED starts to flash. Then wait until the Q product lights up 5 times (3 x short, 2 x long).

3. The Q product has now been paired and the brightness (+/– button) and/or light colour of 2700-5000 Kelvin can be set.
The Q product is now assigned to the first group and another Q product can be paired and assigned to the group as described.

If the Q product lights up only 3 times, please repeat the whole process. If necessary, restore the Q product to the factory setting (reset) by manually turning it on five times (on/off/on/off/on/off/on/off/on at intervals of 1-2 seconds). To assign Q- products to groups 2 and 3, proceed as described above, just now select group button 2 or 3.

B | Other functions
B.1 | Removing Q products from groups 1 | 2 | 3
  1. To remove a Q product from a group, please select the group concerned via the 1 | 2 | 3 buttons.
  2. Now manually switch off all Q lights (via wall or pull cord switches) and leave on only the Q products that are to be removed.
  3. Hold Q-RC up close to the Q products (< 30 cm) and then hold down the P button until the status LED flashes. Now the Q product flashes too and signals successful removal from the group.

Pairing the Q products to a ZigBee-compatible gateway or ZigBee-compatible wall pushbutton (e.g. Busch-Jaeger ZigBee switches) and controlling them via smart media app / Q-RC

If you want to control a Q product via an app or a ZigBee-compatible wall push-button and use the Q-RC as well, the Q-RC has to be connected to the gateway or wall push-button first. Otherwise there is a danger that upon activation using the Q-RC the selected Q product will be removed from the ZigBee network if the product had previously already been incorporated into it.

B.2 | Pairing to an app/gateway
  1. First reset the Q-RC (see C).
  2. Now in the app add the Q-RC as a ‘New device’. To do that, hold the Q-RC close (< 30 cm) to the gateway and hold the Q-RC’s On/Off button down for more than 3 seconds until the status LED is flashing permanently. The Q-RC is now connected to the gateway.
  3. Now pair the ZigBee-compatible Q product to the gateway (see the relevant app provider’s instructions). If you want to control the Q product via the Q-RC as well, it must now also be paired afresh with the Q-RC (see A ).
B.3 | Pairing to a wall push-button
  1. First reset the Q-RC (see C ).
  2. Now create a new network using the wall push-button (see Busch Jaeger controller wall push-button’s instructions). Hold the Q-RC close to the wall push-button (< 30 cm) and hold down the Q-RC’s On/Off button for more than 3 seconds until the status LED is flashing permanently. The Q-RC is now connected to the wall push-button.
  3. Now pair the ZigBee-compatible Q product to the Q-RC (see A ).
C | Resolving problems

Restore the Q-RC to factory settings (reset)
Before resetting, press the + or – button. If the status LED lights up, the Q-RC can be reset. If the status LED does not come on, the Q-RC is already reset.

If neither the status LED nor the groups LED come on, please change the batteries or contact customer service (+49 (0) 29 22-97 21 92 90).

Reset Q remote control

  1. Activate Q-RC by tapping on any button.
  2. Hold down W button until status LED flashes.
  3. Within 10 seconds, press the On/Off button and thus confirm the process. If the status LED now flashes quickly in succession, the Q-RC is reset.
Technical specifications
Wireless standard: ZigBee light link – 2,4 Ghz
Power requirements: 2 x AAA batteries, 1.5 volts
Battery life: c. 1 year with 20 activations per day
Operating temperature: -20° to +40°C
Dimensions: L 125 x W 56 mm, H 11 mm

All information subject to change or correction. This product conforms to the CE requirements and other relevant standards. This device fulfils the fundamental requirements of Directive 2014/53/ EU (Radio Equipment Directive) of the European Parliament and of the Council of the European Union dated 16.04.2014 on items of radio equipment. The complete Declaration of Conformity is available on the internet at the following address:

Neuhaus Lighting Group GmbH
Olakenweg 36 . D-59457 Werl
Telefon: + 49 (0) 29 22-97 21- 0
Telefax: + 49 (0) 29 22-97 21- 9120
E-mail: kundenservice@paul-neuhaus.de
https://scm.paul-neuhaus.de/public/conformity/

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals