ROBERT JULIAT 1166 300W LED Followspot
Product Information: Robert Juliat 1166/C Followspot
- Product Name: Robert Juliat 1166/C Followspot
- Model Number: REF 1166/1166C
- Version : V2
- Product Type: Standard North American Followspot
- Manufacturer: Robert Juliat S.A.S.
- Address: 32, rue de Beaumont, F 60530 Fresnoy-en-Thelle
- Phone: +33 (0)3 44 26 51 89
- Fax: +33 (0)3 44 26 90 79
- Email: info@robertjuliat.fr
- Website: www.robertjuliat.com
- Validation Date: 26/01/22
- Compliance Standards: NF EN 60598-1, NF EN 60598-2-17, Low Voltage Directive 2014/35/UE & EMC Directive 2014/30/UE
- IP Rating: IP20 (Indoor use only)
- Power Consumption: 300W LED
Product Usage Instructions:
- This product is not for residential use.
- This product should only be serviced by a qualified technician.
- Adhere to relevant health and safety requirements of the appropriate EU Directives at all times.
- This fixture is in compliance with section 17 – Lighting appliance for theatre stages, television, cinema, and photograph studios.
- This fixture is rated as IP20 and is for indoor use only.
- Ensure the fixture is correctly mounted on an appropriate support.
- Protection screens and lenses must be replaced if damaged, as these might reduce performance.
- When hung or flown, the fixture must be secured by an additional hanging accessory (such as a safety cable or bond) of suitable length.
- Safety bonds or cables must be securely attached to the back of the fixture and be as short as possible or rolled up as necessary to minimize travel distance should the fixture be dislodged.
- Movable accessories (scroller, etc.) must also be secured with a suitable safety cable or bond at the front of the fixture.
- The combined weight of both the fixture and the accessories must be considered when choosing the load-bearing capability of safety cable or bond.
- Do not open the lighting fixture when the source is on.
- Allow the fixture to cool before servicing, as LED sources become hot during use.
- Do not tamper with the design of the fixture nor any of its safety features.
- Tighten electrical mains cable connections regularly and replace with one of identical specifications if damaged.
- Use only with the correct power supply.
- Keep well away from flammable material and do not cover the fixture or permit it to get wet.
- To avoid overheating, do not obstruct air vents and ensure any cooling fans are in correct working order. If fans are not working, turn off the fixture immediately and service as necessary.
- To clean the optical parts, use a soft cloth in combination with distilled water or isopropyl alcohol recommended for coated optics. Do not touch the LED source with your fingers.
GENERAL INSTRUCTIONS
- Not for residential use.
- These fixtures must only be serviced by a qualified technician.
- In addition to the instructions indicated on this page, relevant health and safety requirements of the appropriate EU Directives must be adhered to at all times.
- This fixture is in compliance with section 17 – Lighting appliance for theatre stages, television, cinema and photograph studios. Standards NF EN 60598-1, NF EN 60598-2-17, Low Voltage Directive 2014/35/UE & EMC Directive 2014/30/UE.
- This fixture is rated as IP20, and is for indoor use only.
FIXTURE
- Ensure fixture is correctly mounted on an appropriate support.
- Protection screens and lenses must be replaced in the event of any damage, such as cracks or deep scratches, since these might reduce performance.
- When hung or flown the fixture must be secured by an additional hanging accessory (such as a safety cable or bond) of suitable length.
- Safety bonds or cables must be securely attached to the back of the fixture and be as short as possible, or rolled up as necessary, to minimise travel distance should the fixture be dislodged.
- Movable accessories (scroller, etc.) must also be secured with a suitable safety cable or bond at the front of the fixture.
- The combined weight of both the fixture and the accessories must be considered when choosing the load-bearing capability of safety cable or bond.
- Do not open lighting fixture when the source is on.
- WARNING: LED source become hot during use. Allow fixture to cool before servicing.
- Do not tamper with design of fixture nor any of its safety features.
- Tighten electrical mains cable connections regularly and replace with one of identical specification if damaged.
- Use only with correct power supply.
VENTILATION
- Keep well away from flammable material.
- Not for outdoor use. Do not cover. Do not permit fixture to get wet.
- To avoid overheating, do not obstruct air vents.
- Ensure any cooling fans are in correct working order. If fans are not working, turn fixture off immediately and service as necessary.
CLEANING
- Do not touch the LED source with your fingers.
- To clean the optical parts, use a soft cloth in combination with distilled water or isopropyl alcohol recommended for coated optics. Do not use any cleaning product that contains solvents or abrasives, as these can cause surface damage. Dry with a soft lint-free cloth.
- Regularly remove dust with a soft lint-free cloth.
- If the fixture has filters, they must be cleaned frequently.
POWER SUPPLY
- Disconnect from the mains before servicing.
- Main connection only. Do not connect to “electronic output” such as a dimmer.
- Ensure power supply circuit breakers, always remain accessible.
PLEASE NOTE
This product has been built to conform to European standards relating to
professional lighting equipment. Any modification made to our products will
void the manufacturer’s warranty.
Risk group 2
CAUTION: Possibly hazardous optical radiation is emitted from this product. Do not stare at the operating lamp. May be harmful to the eye.
Group risk 2. Luminaires should be positioned so that prolonged staring into luminaire at a distance closer than 11,4m is not expected.
Photobiological safety according to EN62471
Presentation
Functions
- Identification plate
- Data connectors (IN and OUT)
- Power connectors (IN and OUT)
- Thermal breaker
- Power switch
- Control board
- Wireless DMX antenna (option)
- Handle
- Safety cable attachment point
- Yoke
- Tilt index
- Tilt locking handle
- Gate: slots for gobo holder and/or iris
- Dimmer rotary knob
- Colour changer
- Focus adjustment
- Lens tube access
- Zoom adjustment
- Display screen
Identification label
Description
- MOD.: Model
- VERS. : Version
- U: Nominal voltage input (V)
- I: Nominal intensity (A)
- P: Maximum power input (W)
- IP: International Protection Rating
- t°a : Maximum ambient temperature (°C)
- t°c: Maximum external temperature of the unit (°C)
- Net weight (kg)
- The minimum distance between a flammable material and the lighting unit (m)
- Color temperature version :
- CW = Cool White
- WW = Warm White
- NDW = Neutral Daylight White
- Serial number
- Replace broken glass
- Class 1 product label
- Read manual first label
- European conformity label
- WEEE directive label
- EN62471 – Risk group
- CEI-TR-62778 – Do not stare at light source
Units :
- Weight = kilogram (kg).
- Intensity = Ampere (A).
- Voltage = Volt (V).
- Frequency = Hertz (Hz).
- Temperature = degree Celsius (°C).
Accessories included
Optional accessories
Set-up
Mechanics
Operating positions
Minimum distance between a flammable material and the lighting unit
Instructions for use
Lifting
- Net weight: 20 Kg (44,1 lbs).
Stand set-up
- Compatible stands: GT800 & GT1000
Please refer to the relevant user manual for further details.
Electrical information
LED source
Never touch or scratch the LED surface.
Cf. EN-19, 6.1.4 LED cleaning procedure if cleaning is necessary.
Power supply
Power cable
Power on
DATA
DATA connectors
Integrated terminal plug:
If no XLR connector is detected on DMX OUT connector, a 120Ω terminal plug is
automatically activated. Additional terminal plug on the last unit is not
necessary.
Wireless DMX option
Accessories
Iris
Gobo holder
Colour changer unit – push-pull
Operations
Light intensity
Range
Control
HTP mode (Highest Takes Precedence):
Light output is the highest value of DMX512 command or local control
Focus mode: when standby screen displayed,
- Push Exit → Light output = 100% for 1 minute
- 2x times Exit → Light output = 0%
- Local control → via rotary knob
Parameters
Resolution (MODE):
Curve (LIGHT CURVE): Linear / Square
Smoothing (SMOOTHING) :
Master mode (MASTER CONTROL):
In order to supervise the operator from the console, a 3rd DMX channel is
used: Master control. This channel limits the maximum value of the dimmer
shutter. By using this function, it’s possible to obtain synchronized fades
with several spots or to give intensity limits (minimum and maximum) to the
operator . Master is only active when DMX is detected.
Mode required when simultaneous remote and local control are necessary (example: follow spot)
Beam size adjustment
Range
Control
Strobe
Range
Control
Pan / Tilt
Range
Control
Iris
Range
- Irising
Control
Gobo
Range
Color
- Fixed color: place dark colors towards the rear end.
Range
DMX Controls
Control board
Display and Controls
Menus and parameters
Please scan this QR-Code for the software menu or go to :
www.robertjuliat.com/productSearch.html
to find the latest version.
DMX chart
Reset
- Reset to default settings:
Menu: Fixture Reset → press Select → Yes & press Select to validate
Feedback information
- DMX and system LED feedback (see display & controls 7 , Cf. EN-15):
- ⇒ Green= DMX512 frame detected
- ⇒ Red = Problem on DMX512 frame and/or system default – details available in the fixture status
- If DMX512 data lost, the following message is displayed:
- “Push select to reset DMX values”
- The last received DMX values are stored but it is possible to inactivate the current values by pressing the Select key (as well as the Master function) in order to get a total control of the fixture locally. When a DMX signal is detected, the DMX control is active again.
- ¥ signal indicates a wireless DMX:
Service
Preventive maintenance
Frequency
General maintenance should be performed at least once a year or more
frequently if the equipment is operated in adverse conditions (smoke, heat,
humidity, touring, etc.).
General cleaning
Remove dust from the unit (air vents, printed circuit boards, etc.).
During cleaning:
- LED is protected by a safety glass to avoid any contact. DO NOT spray directly onto the glass.
- Fan blades must be locked.
General visual check
- No trace of heat.
- No loose contacts.
- No missing parts.
- Tighten mechanical assemblies (screws, bolts and nuts, ground connections, etc.).
LED source
- Do not touch the surface of the LED source (no contact with your hands or any tools).
- Do not put compressed air directly on the source.
- Contact a certified RJ distributor in case of residuals or other objects located on the surface of the LED source.
Optics
The cleaning of optical parts (lenses) shall be carried out with solutions
containing alcohol.
Analysis
If there is still a problem after the troubleshooting procedures (Cf. section
7), contact RJ distributor with the following information:
- Model, version and serial number of the product.
- Software version (available in menu Fixture Status → Version)
- Description of the problem.
LED reaction according to LED temperature
LED intensity dims to zero output (overheating protection). DMX and system LED feedback (7) is red and temperature is available in Fixture Status menu.
Thermal protection
In case of thermal protection start :
- Remove the LED compartment (Cf. 6.1.4 ).
- Control possible overheating indications.
- Reassemble the LED compartment.
- Reset the thermal protection by pressing the button.
Adjusting the maximum light output level
The maximum intensity level of the LED source can be adjusted through the
fixture setup in order to have a consistent fixture fleet. The dimming level
is then recalculated depending on the limitation.
Troubleshooting
General information
Exploded view / Spare parts list
- Available on www.robertjuliat.com
- Or on request through the Robert Juliat Service department info@robertjuliat.fr
References
- ROBERT JULIAT - Robert Juliat is a leading specialist in the manufacture of high-quality PC, Fresnel and profile spots, followspots, and cyclorama and foot-lighting for theatres, opera houses, TV, architecture and more. Made in France since 1919.
- Robert Juliat - Product Search
- ROBERT JULIAT - Le site officiel
- Robert Juliat - Recherche d'un produit
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>