UNI-T UDP6700-DC Digital Control Power Supply User Manual
- June 9, 2024
- UNI-T
Table of Contents
- UDP6700-DC Digital Control Power Supply
- Limited Warranty and Liability
- Safety Information
- Product Series
- Basic Performance
- Specifications
- Packing List
- Operating Environment
- Memory Group Voltage/Current Setup
- Troubleshooting
- List Mode (Time Function) and Delayer Mode
- Parameter Setting of List Mode
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UDP6730 Series Digital Control
Power Supply
User’s Manual
UDP6700-DC Digital Control Power Supply
Perface
Thank you for purchasing this brand new product digital control power
supply. In order to use this product safely and correctly, please read this
manual thoroughly, especially the safety notes.
Copyright Information
Copyright is owned by Uni-Trend Technology (China) Co., Ltd.
UNI-T products are protected by patent rights in China and other countries,
including issued and pending patents.
Uni- Trend reserves the rights to any product specification and pricing
changes.
Uni-Trend Technology (China) Co., Ltd. all rights reserved. Trend reserves all
rights. Information in this manual supersedes all previously published
versions. No part of this manual may be copied, extracted or translated by any
means without the prior permission of Uni Trend.
UNI-T is the registered trademark of Uni Trend Technology (China) Co., Ltd.
Warranty Service
The instrument has a warranty period of one year from the date of purchase.
If the instrument is damaged due to improper operation by the user during the
warranty period, the maintenance fee and the costs caused by the maintenance
shall be borne by the user, and the instrument shall be maintained by the
company for life.
If the original purchaser sells or transfers the product to a third party
within one year from the date of purchase of the product, the warranty period
of one year shall be from the date of the original purchase from UNI-T or an
authorized UNl-T distributor. Power cords, accessories and fuses, etc. are not
included in this warranty.
If the product is proved to be defective within the warranty period, UNI-T
reserves the rights to either repair the defective product without charging of
parts and labor, or exchange the defected product to a working equivalent
product (determined by UNI-T). Replacement parts, modules and products may be
brand new, or perform at the same
specifications as brand new products. All original parts, modules, or products
which were defective become the property of UNI-T.
The “customer” refers to the individual or entity that is declared in the
guarantee. In order to obtain the warranty service, “customer “must inform the
defects within the applicable warranty period to UNI-T, and perform
appropriate arrangements for the warranty service.
The customer shall be responsible for packing and shipping the defective
products to the individual or entity that is declared in the guarantee. In
order obtain the warranty service, customer must inform the defects within the
applicable warranty period to UNI-T, and perform appropriate arrangements for
the warranty service. The customer shall be responsible for packing and
shipping the defective products to the designated maintenance center of UNIT,
pay the shipping cost, and provide a copy of the purchase receipt of the
original purchaser. If the products is shipped domestically to the purchase
receipt of the original purchaser. If the product is shipped to the location
of the UNI-T service center, UNI-T shall pay the return shipping fee. If the
product is sent to any other location, the customer shall be responsible for
all shipping, duties, taxes, and any other expenses.
Limited Warranty and Liability
The warranty is inapplicable to any defects, failures or damages caused by
accident, normal wear of components, use beyond specified scope or improper
use of product, or improper or insufficient maintenance. UNI-T is not obliged
to provide the services below as prescribed by the warranty:
a) Repair damage caused by installation, repair or maintenance of personnel
other than service representatives of UNI-T;
b) Repair damage caused by improper use or connection to incompatible
equipment;
c) Repair any damages or failures caused by using power source not provided by
UNI-T;
d) Repair products that have been changed or integrated with other products
(if such change or integration increases time or difficulty of repair).
The warranty is formulated by UNI-T for this product, replacing any other
express or implied warranties. UNI-T and its distributors refuse to give any
implied warranty for marketability or applicability for special purpose. For
violation of the warranty, repair or replacement of defective products is the
only and all remedial measure UNI-T provides for customers.
No matter whether UNI-T and its distributors are informed of any possible
indirect, special, occasional or inevitable damage in advance, they assume no
responsibility for such damage.
Safety Information
Warning Caution:
To avoid possible electric shock and personal safety problem, please follow
the instructions below.
Disclaimer| Please read the following safety information carefully before
starting to use the instrument. Uni-Trend will not be responsible for the
personal safety and property damage caused by the user’s failure to comply
with the following terms.
---|---
Instrument Grounding| To prevent the risk of electric shock, please connect
the power ground wire.
Operating voltage| Please make sure operating voltage under rated range of
10%, to avoid damage the instrument.
Input voltage| Please use AC 110V~220V 50/60Hz AC power supply, use national
approved power cord and make sure insulating layer is in good condition.
Inspecting the wire of the instrument| Inspecting the condition of the
insulating layer of the wire, check if it is broken, bareness or workable. If
the wire is damaged, please replace it before connect with the instrument.
Fuse wire of the instrument| Only allowed use the dictated specification fuse
wire.
Over-voltage protection| Please make sure the instrument is not over-
voltage(such as the voltage caused by thunder. To prevent operating personnel
away from electric shock.
Do Not
open the cover when the instrument is in operating| Please do not operating
the instrument when open the cover and do not change the internal circuit.
Do Not
touch live part| When the instrument is in operating, do not touch the bare
connect wire, spare input terminal and the circuit is in testing. When the
instrument is over DC 60V or AC 30V, be careful electric shock.
Do Not
use the instrument in an explosive atmosphere| Do not use the instrument in
flammable and explosive gas, steam or dusty environment.
The use of any electronic equipment in such an environment is a risk to
personal safety.
Safety Mark
| Grounding| | On (Power)
---|---|---|---
| Protective Grounding| | Off (Power)
| Signal Ground| | Connect with Cabinet or Case
| Dangerous Mark| |
Environment-friendly Use Period
EFUP is the period of time before any of the RoHS substances are likely to
leak out, causing possible harm to health and the environment. EFUP of this
instrument is 40 years, it should be recycling system when exceed 40 years.
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC
Must not be discarded in the trash can.
Product Series
UDP6730 Series Digital Control Power has two models, UDP6730 and UDP6731.
Output range as follows,
Model | Output Range |
---|---|
UDP6730 | 0-40V,0-30A, 0-360W |
UDP6731 | 0-80V,0-15A, 0-360W |
Characteristics
- Fully digital control
- High resolution 10mV/1mA
- Low ripple and noise
- Software calibration
- Smallest outline
- High-definition LCD display
- Remote Sense compensaton
- Support RS-232 communication
- Intelligent fan regulation
- Rated voltage and current output·
- High-reliability: OVP(over voltage protection)/OCP(over current protection)/OTP(over temperature protection)
- Output on/off control
- High performance-price ratio
- Storage for 3×200 preset voltage and current output
Basic Performance
UDP6730/UDP6731 digital control power supply with widest voltage and current
range, it can applied in many fields.
Take UDP6730 for example, with max power 360W and output adjustable in
40V/30A, auto control voltage and current slew rate, power rate up to three
times rapid than other similar products. One instrument can replace three
models (40V×9A/24V×15A/12V×30A), save your repeat investment.
Example
Take UDP6730 for example,set output voltage as 40V, because the max power of
UDP6730 is 360W, so the max output current is 360W/40V=9A. When output voltage
down to 20V, the max output current turns to 360W/20V=18A. The max output
current of UDP6730 is 30A, if the output voltage continue decrease , the max
output current of UDP6730 still as 30A.
Specifications
Specification | UDP6730 | UDP6731 | |
---|---|---|---|
Output Range | Voltage | 0-40V | 0-80V |
Current | 0-30A | 0-15A | |
Power | 360W | 360W | |
Load Regulation | Voltage | <0.03%+15mV | <0.03%+30mV |
Current | <0.03%+30mA | <0.03%+15mA | |
Power Supply Regulation | Voltage | <0.03%+15mV | <0.03%+30mV |
Current | <0.1%+15mA | <0.1%+10mA | |
Programming Accuracy | Voltage | <0.1%+30mV | <0.1%+10mV |
Current | <0.3%+2mA | <0.3%+10mA | |
Read-back Accuracy | Voltage | <0.1%+10mV | <0.1%+10mV |
Current | <0.3%+30mA | <0.3%+10mA | |
Ripple and Noise | Voltage | <12.0mV rms | <12.0mV rms |
Current | <72.0mA rms | <27.0mA rms | |
Dimension | wxHxD | 87x174x255(mm) | 87x174x255(mm) |
Weight | Net | <2.5Kg | <2.5Kg |
Front Panel Rear Panel
Packing List
Before use the instrument, please,
- Check whether the appearance is damaged, scratched or has other defects;
- Check with packing list to confirm that accessories has no loss.
If there have any problem, please contact with Uni-Trend Instrument Sale Department or the distributor.
Components | Quantity | Remarks |
---|---|---|
The instrument | 1 | The model is subject to the actual order |
3C power line | 1 | |
250V/5A spare fuse | 2 | Only For 220Vac input. |
Alligator pics with parallel wire | 1 | |
User’s Manual /Upper computer software | 1 | Electronic file,download from the |
official website
Requirements of Power Supply
UDP6730 series digital control power supply can only use under the power
supply terms as the table below.
Parameter | Requirements |
---|---|
Voltage | AC110/ 220(± 10%)V |
Frequency | 50/60Hz |
Fuse | AC220V input voltage: 250V/5A |
Fuse | AC110V input voltage: 250V/8A |
- Factory supply three-core power cable, please make sure power cable of three phase socket is connect with ground before use.
- This instrument 220V is select fuse of 250V/5A , the specification is 5×20mm. There is one more 250V/5A fuse in fuse box before the product leave the factory.
- Please remove the external power cable before replace the fuse, open the fuse socket slot under the power supply plug, take out the old fuse and replace the new fuse into it, after that the instrument can be used normally.
Warning: Do not use power cable with any signs of damage to avoid danger!
Operating Environment
UDP6730 series digital control power supply can only use in normal temperature and low condensing zone. The general environmental requirements of the instruments is listed as the below table.
Operating Environment | Environmental Requirements |
---|---|
Temperature | 0℃~45℃ |
Humidity | 20%~80%(non- condensation) |
Storage temperature | -20℃~70℃ |
Altitude | ≤2000 meter |
Pollution degree | 2 |
Explanation: In order to guarantee the accuracy of measurement, it is
suggested that turn on the instrument half an hour before operating.
Cleaning
To prevent from the risk of electric shock, please pull out power line before
cleaning.
Please use a clean cloth dipped in clean water to clean the cover and panel.
Do not clean the inside of the instrument.
Caution: Do not use solvents (alcohol or gasoline etc.) to clean the
instrument.
Quick Start
Appearance Inspection
- Check out the instrument is in a good condition during the delivery. If there have any problem, please contact with Uni-Trend Instrument Sale Department or the distributor.
- Confirm whether the AC input voltage of UDP6730/UDP6731 comply with the standards of your country or region.
Notice: Use 110V/220V switch on the rear panel to select input voltage.
After confirming the above matters, power on the instrument.
Voltage Setup
- Push key to set voltage value;
- Push or to select the specific numeric field;
- Rotating to enter the defined voltage parameter.
Current Setup
- Push key to set current value;
- Push or to select the specific numeric field;
- Rotating to enter the defined current parameter.
Enable Output
- Push to enable power output function and the indicator light will be green. In the mean time, C.V/C.C indicator light will be green or red light according to the different output mode;
- OUTPUT key indicator light will be off when OUTPUT function is disable. C.V/C.C indicator light will also be off.
Keyboard Lock
Lock keyboard function is prevent unauthorized worker or operating personnel
form making accident operation. To avoid damage the device under test.
- Push Lock key to enable lock keyboard function and the indicator light will be green. Lock symbol will shown on the top of screen.
- In lock status, long push Lock key to unlock the function and indicator light will be off. Lock symbol will also disappear on the screen.
OVP Function
- Long push key to set OVP function;
- Push or to select the specific numeric field and enter OVP parameters;
- Push or to enable OVP function;
- When the OVP function set successfully, ☑ mark will shown beside OVP parameters.
OCP Function
- Long push key to set OVP function;
- Push or to select the specific numeric field and enter OCP parameters;
- Push or to enable OCP function;
- When the OCP function set successfully, ☑ mark will shown beside OCP parameters.
Beep Switch
- Push to enter the setup interface, rotate to adjusting buzzer mode;
- When the buzzer function is enable, keyboard sound is also turn on; when the buzzer function is disable, keyboard sound will be silent. Buzzer status will shown on the top screen.
- Push to exit the setup page.
Brightness Setup
- Push to enter the setup interface;
- Push or to select Brightness field;
- Rotate to set the brightness, adjusting range 0~100%;
- Push to exit the setup page.
Memory Group Setup
- Push to enter setup interface;
- Push or to select Memory option;
- Rotate to set memory group, the maximum range is 200;
- Push to exit the setup page.
Memory Group Voltage/Current Setup
Set the specific output voltage/current point and select memory key M1~M3,
push it to save the current setting.
When user need to call the stored output voltage/current, enter the setup
interface to select the specific memory group and then push memory key M1~M3
to call the specific stored output voltage/current.
When user call the stored output voltage/current, the corresponding memory key
will indicate green light. Output Mode Setup
- Push to enter setup interface;
- Push or to select the output status bar;
- Rotate to select Out State;
- Output status symbol will shown on the top screen when output is finished;
- Push to exit the setup page.
Notice: When output function is operating, power supply should remain enable status. That is, should keep operating status when turn off the power supply. Language Setup
- Push to enter setup interface;
- Push or to select language field;
- Rotate to select Language type (English/Chinese);
- Push to exit the setup page.
Display Interface Information
- Push to enter the setup interface;
- Use left, right arrow key to select the IO Information option;
- RS232 configuration information will shown on the right side of the screen.
About
- Push to enter the setup interface;
- Push or to select About field;
- The device information product’s model and the current version number will shown on the right side of the screen.
Remote Sense Compensation
Setup
Before use Remote Sense compensation function, take off short connect terminal
on the Remote Sense compensation terminal, connect load voltage positive
terminal to compensation terminal S+ and load voltage negative terminal
connect to compensation terminal S-. And then enable power output to turn on
Remote Sense compensation function. That is, the output voltage of the DC
power supply is the voltage of the load terminal.
Notice: Remote Sense compensation voltage should less than 0.9V. CV/CC
Operating Mode of Power Supply
Power supply can automatic transfer constant voltage/current function. Power
supply can ongoing switch the constant voltage/current function dependent on
load fluctuation.
If the current load is on the constant voltage mode, power supply provide a
controlled output and voltage. As the load resistance value decreases, the
output voltage remains constant until the output current increases to greater
than the preset current value, which it will convert operating mode. If the
power supply turn into constant current output, the output voltage will
decrease proportionally according to resistance value of the load. When the
current value less than the set value, power supply will back to the constant
voltage mode.
Troubleshooting
Power supply is no output
- Check the set value of voltage and current is zero or not. If it is, reset the voltage and current value.
- OUTPUT indicator light is light on or not. If it is, push OUTPUT key to enable the output function.
- Check OVP,OCP,OTP function is activated or not. If it is, reset the value of OVP, OCP and wait the power supply remain stable to turn the output function.
- If Remote Sense compensation function has been enabled, check the line loss of output cable is excepted the limit value or not. If it is, replace the output cable or decrease the output current, and then try to enable the power supply again.
The keyboard is not work
Check Lock indicator light is light on or not. If it is, please refer to Lock
section to reset again.
Remote Communication
The instalment and startup configuration file
- Download the instalment file from official website;
- Turn on power supply;
- Connect the control line of RS232 to control power supply;
- Activate the remote controlling application program;
- Click Shipments List, and double-click the power supply symbol of UDP6730 or UDP6731 to enter the remote communication interface.
Remote Control Interface & Operating Instructions
List Mode (Time Function) and Delayer Mode
List Mode
List mode can setup multiple testing program, it can set 48 groups of
independent ant voltage, current and parameter of output duration time.
Delayer Mode
Delayer mode can setup multiple testing program to control output status,
which is set count to control output status is on or off, and the time
interval of switch can also set by point to point. Delayer mode can set 48
output status groups to control parameter.
Output parameter of list/delayer mode can all store in internal storage. It
has power down function. Storage space for each group is 48
Operating Steps
-
Push power supply switch to turn on the instrument;
-
Turn on list mode/ delayer mode: Push arrow key or to enter setup interface of list/delayer mode. It can be circular switch.
Notice:
a. List/delayer mode and channel output function can’t use at the same time, it can only choose either-or;
b. When List mode status is pause, delayer mode can’t set parameter. It should enter setup interface of list mode to switch to , and the status is pause and then to set parameter; -
Connect with load;
-
Set parameter of list/delayer mode;
Please refer to section Parameter Setting of List Mode and Parameter setting of Delayer Mode. -
Enable timing/delayer output;
In timing/delayer interface, rotate rotary knob to and push to enable timing/delayer output function. Symbol turn to and status bar will also change to “stop” to “run”; -
Disable timing/delayer output;
In timing/delayer interface, rotate rotary knob to and push to disable timing/delayer output function. Symbol turn to and status bar will also change to “run” to “stop”;
Another shortcut to disable output function, push key to turn off timing/delayer function in any interface.
Parameter Setting of List Mode
Menu introduction of list mode
Cycle index:It divide into maximum inf and 1-999. A cycle period is start form
setup origin point to end point. Push rotary knob to adjusting parameters.
Count: It can set “001” – “048”, which is excite group from origin point to
end point. Push rotary knob to adjusting point. Notice: each voltage, current
and time is a point.
Origin point: It can adjust “000”-“047”, which is start from origin point to
run. (“origin point” value + “count” value ≤ 048)
Mode: It divide into three mode stop, run and pasue, it can not be set;
Pause presents power supply is not output at the current;
Run presents power supply is operating;
Pause presents power supply is paused;
Notice: In pause and run mode, interface can not be adjust; pause only
shown when indicator is off and only shown on interface. This curve figure can direct present the setting parameter of
list mode. Table setting: serial
number of each group is corresponding to voltage, current and time value, push
rotary knob to set parameter;
Voltage: adjust the actual output voltage value;
Current: adjust the current value;
Time: duration output time value in this serial number; , : operating
status at the current, push rotary knob to switch mode;
Save: save the setting parameter for power down function, push rotary
knob to save the current setting;
: clear parameter values in the table all to zero (voltage 00.00, current
00.00, time 00.00), push rotary knob to eliminate the setting parameter values
in the table;
Notice: clear select function is eliminate the corresponding group of
origin point to count.
Parameter Setting of Delayer Mode
It presents power output status and delayer time of user configuration,it’s
convenient to view the data. Protection setting:this function can set
protection value of voltage, current and power, push rotary knob select “√”to
turn on protection function;
Cycle index:It divide into maximum inf and 1-999. A cycle period is start form
setup origin point to end point;
Count:It can set “001” – “048”, which is excute group from origin point to end
point. Push rotary knob to adjusting parameter;
Origin point: It can adjust “000”-“047”, which is start from origin point to
run. Push rotary knob to adjusting parameter (“origin point” value + “count”
value ≤ 048) Mode: It divide into three mode stop, run and pasue, it can not
set;
Stop presents power supply is not output at the current;
Run presents power supply is operating;
Pause presents power supply is paused;
Notice: In pause and run mode, interface can not be adjust; pause only
shown when protection function is enabled. Table setting:serial number of each group is corresponding to
output status and delay time, push rotary knob to set parameter
Mode:ON presents output function is enabled, OFF presents output function is
disabled
Time:set the delay time of the main interface;
, : operating status at the current, push rotary knob to switch mode;
Save: save the setting parameter for power down function, push rotary knob to
save the current setting;
: clear parameter values in the table all to zero (voltage 00.00, current
00.00, time 00.00), push rotary knob to eliminate the setting parameter values
in the table;
Notice: clear select function is eliminate the corresponding group of
origin point to count.
UNI-TREND TECHNOLOGY (CHINA) CO.,
LTD.
No.6, Gong Ye Bei 1st Road,
Songshan Lake National High-Tech Industrial
Development Zone, Dongguan City,
Guangdong Province, Chinatruments.uni-trend.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>