Rofeer Breathalyzer EK918 Portable Fuel Cell Sensor Alcohol Meter User Manual
- June 10, 2024
- Rofeer
Table of Contents
- Breathalyzer EK918 Portable Fuel Cell Sensor Alcohol Meter
- Product Information
- Product Usage Instructions
- Test Results
- Testing Tips
- Concentration Unit Setting
- Contact Information
- Statement of Responsibility and Warnings
- Statement of Responsibility
- Alarm Settings
- Default Alarm Values
- Package Contents
- Device Components
- Operation
- Test Results
- Testing Tips
- Concentration Unit Setting
- Adjusting the Alarm Value
- Default Values of the Triggering Alarm
- Memory Mode
- Powering Off
- Low Battery Indication
- View Version
- Detection Range
- Alcohol Concentration Conversion Table
- Warranty Conditions
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Breathalyzer EK918 Portable Fuel Cell Sensor Alcohol Meter
Product Information
The Breathalyzer EK918 is a device that measures blood alcohol concentration (BAC) in the breath. It is equipped with alarms that sound when the BAC value exceeds a certain level. The device is calibrated by engineers and can be used right out of the box. The package includes a breathalyzer, 10 mouthpieces, a USB cable, a user manual, and a storage bag. The device has a mouthpiece, LCD screen, power button, M button, vent, buzzer, charging port, and charging indicator.
Product Usage Instructions
- To take a test, press the power button to turn on the device. The device will begin counting down from 10 and needs 10 seconds to preheat.
- When the timer expires, the screen will display START.
- Within 20 seconds of the start, the user should begin blowing into the mouthpiece. Continue blowing for at least 5 seconds.
- Do not make changes or press buttons on the device during this step. The device will take a moment to analyze and then display the result on the screen. The result will be displayed for 15 seconds, and the device will then return to the home screen.
Test Results
- Safe Level Detected: If the result value is lower than the warning value, the device will beep once to indicate a safe level was detected.
- Warning Level Detected: If the result value is between the warning value and the danger value, the device will emit a warning series of three beeps.
- Dangerous Level Detected: If the result value is higher than the danger value, the device will beep continuously for 15 seconds.
Testing Tips
- Wait 20 minutes after eating, drinking, or smoking before testing.
- Do not block the air outlet while blowing.
- The testing data from this device cannot be used in court.
- Drink responsibly.
Concentration Unit Setting
To adjust the concentration unit settings, follow the steps below:
- Press the power button to turn on the device.
- Click the M button to enter the settings page for the concentration unit.
- Click the M button repeatedly to cycle through the unit options. (The unit options are: %BAC, BAC, mg/L, g/L, mg/100mL, PROM)
Contact Information
If you have any questions or comments about the device, please contact the customer line at www.alza.co.uk/kontakt or +44 (0)203 514 4411. Keep the user manual for future reference.
Statement of Responsibility and Warnings
- The results from this product are for reference only. The manufacturer and seller are not responsible for any behaviors that break the law.
- Do not drink and drive.
- Wait at least 20 minutes after drinking, eating, or smoking before using this device. Failure to do so can cause inaccurate results or damage the sensor.
- The device is equipped with alarms that will sound if the measured value is greater than the set alarm triggering values.
- Default Alarm Values: Warning Alarm: Sounds at 0.02% BAC Danger Alarm: Sounds at 0.05% BAC.
The product user guide contains product features, how to use, and the operating procedure. Read the user manual carefully to get the best experience and avoid unnecessary damage. Keep this manual for future reference. If you have any questions or comments about the device, please contact the customer line.
- ✉ www.alza.co.uk/kontakt
- ✆ +44 (0)203 514 4411
- Importer Alza.cz a.s., Jankovcova 1522/53, Holešovice, 170 00 Praha 7, www.alza.cz
Statement of Responsibility
The results from this product are for reference only. The manufacturer and seller are not responsible for any behaviours that break the law. Do not drink and drive.
Warnings
-
Wait at least 20 minutes after drinking, eating, or smoking before using this device.
-
Failure to do so can cause inaccurate results or damage the sensor.
Note: Our engineers have already calibrated this device so that it can be used right out of the box. -
Default Unit: %BAC (American Unit)
Alarm Settings
This device is equipped with alarms that will sound if the measured value is greater than the set alarm triggering values.
Default Alarm Values
- Warning Alarm: Sounds at 0.02% BAC
- Danger Alarm: Sounds at 0.05% BAC
Package Contents
- A. Breathalyzer x 1
- B. Mouthpieces x 10
- C. USB Cable x 1
- D. User Manual x 1
- E. Storage Bag x 1
Device Components
- Mouthpiece
- LCD Screen
- Power Button
- M Button
- Vent
- Buzzer
- Charging Port
- Charging Indicator
Operation
To Take a Test
-
Press the power button to turn on the device. The device will turn on and begin counting down from 10. (The device needs 10 seconds to preheat.)
-
When the timer expires, the screen will display “START”.
-
Within 20 seconds of the start, the user should begin blowing into the mouthpiece. Continue blowing for at least 5 seconds.
-
(Do not attempt to make changes or press buttons on the device during this step.) The device will take a moment to analyse and then display the result on the screen. The result will be displayed for 15 seconds, and the device will then return to the home screen.
Test Results
-
Safe Level Detected
If the result value is lower than the warning value, the device will beep once to indicate a safe level was detected. -
Warning Level Detected
If the result value is between the warning value and the danger value, the device will emit a warning series of three beeps. -
Dangerous Level Detected
If the result value is higher than the danger value, the device will beep continuously for 15 seconds.
Testing Tips
- The user needs to blow continuously for 5 seconds to obtain accurate results
- “Err” is displayed if blowing is interrupted. In this event, the device will automatically shut off.
- If the user does not complete the test within 20 seconds of the “START” display, the device will automatically shut off.
Notes about Testing
- Wait 20 minutes after eating, drinking, or smoking before beginning to test. Not doing so can yield inaccurate results and damage the sensor.
- Make sure not to block the air outlet (located on the back of the device) while blowing.
- The testing data from this device cannot be used in court.
- Drink responsibly.
Concentration Unit Setting
To adjust the concentration unit se8ings, follow the steps blow.
- Press the power button to turn on the device.
- Then click the M button to enter the settings page for the concentration unit.
- Click the M button repeatedly to cycle through the unit options. (The unit options are: %BAC, ‰BAC, mg/L, g/L, mg/100mL, ‰PROM
- After selecting your desired unit, click the power button again to save the setting.
Adjusting the Alarm Value
Users can customize the values that will cause the device to emit alarms. It is recommended that the user adjust the values to match the legal limit in their region. To adjust the alarm value, follow these steps:
-
Press the power button to turn on the device.
-
Then double-click the M button to enter the settings page for the alarm values. The
“Warning” alarm value will be displayed on the left and the “Danger” alarm value will be displayed on the right. -
The device will default to the setting for the “Warning” alarm. Click the power button to increase the value and the M button to decrease the value.
-
Press and hold the power button to switch to adjusting the “Danger” value. Use the power and M buttons again to adjust the value (as in the previous step).
-
Double-click the M button to save the settings.
Default Values of the Triggering Alarm
Alarm | BAC (Blood Alcohol Concentration) | **** | BrAC* |
---|---|---|---|
Unit | %BAC | ‰BAC | ‰PROM |
Safe | 0 – 0,02 | 0-0,2 | 0-0,2 |
Warning | 0,02-0,05 | 0,2-0,5 | 0,2-0,5 |
Danger | ≥0,05 | ≥0,5 | ≥0,5 |
*Breath Alcohol Concentration
Memory Mode
The device will store results from the previous three tests. To access the memory of previous results, follow the steps below.
-
Press the power button to turn on the device.
-
Once the device is on, double-click the power button to display the previous test results, starting with the most recent test taken.
Note: Click the M button to display the results starting with the oldest test. -
Double-click the power button to exit.
Powering Off
Press and hold the power button to turn off the device. The device will automatically turn off if it has not been used for a period of 15 seconds.
Low Battery Indication
- When the device battery is low, a “Lo” indicator will flash in the upper right corner of the screen. Use the included USB cable connected to a power source to charge the device.
- While the device is charging, the indicator light will display red. The light will turn green when the device is fully charged.
View Version
To view what version of the operating system your device is currently running, press and hold the M button. The screen will display the device’s current operating system.
Batter | 3,7V, 1000m Ah, Li-ion |
---|---|
Blowing Time | 5 sec |
Working Current | <120 mA |
Quiescent Current | <50 μA |
Operationg Temperature | 32 °F – 104 °F (0 °C – 40 °C) |
Storage Temperature | -4 °F – 122 °F (-20 °C – 50 °C) |
Size | 5,04 x 2,40 x 0,84 inches |
Weight | 127 g |
Input | 5V DC, <780 mA |
Standby Time | 2000 hours |
Default Warning value | 0,02% BAC (adjustable) |
Default Danger Alarm Value | 0,05% BAC (adjustable) |
Detection Range
- 0.000 ~ 0.500 %BAC
- 0.000 ~ 5.000 ‰BAC
- 0.000 ` 2.5000 mg/L
- 0.000 ~ 0.500 g/L
- 0 ~ 500 mg/100 mL
- 0.000 ~ 5.000 ‰PROM
Note: If the resultant value is out of the detection range, the device will display “Hl”. Alcohol Concentration, C (%BAC)| Error
---|---
C < 0.080| ±0.004 %BAC
0,080 ≤ 1,000| ± 5 %
C ≥ 1,000| ± 20 %
Result Units Definitions
- BAC: Blood Alcohol Concentration; the percent of alcohol in a person’s blood stream
- %BAC: How many grams of alcohol are present in 100 mL of blood
- ‰BAC: How many grams of alcohol are present in 1000 mL of blood
- gL: How many grams of alcohol are present in one liter of blood
- mg/100 mL: How many milligrams of alcohol are present in 100 mL of blood
- BrAC: Breath Alcohol Concentration; the percent of alcohol in a person’s breath
- mg/L: How many milligrams of alcohol are present in one liter of blood
Warnings
- Never operate this device outside the acceptable temperature range of 32 °F – 104 °F (0°C – 400 °C).
- For better performance and longer battery life, refrain from using the device in a static environment or during extreme conditions (e.g., near an open 9ame, in a thunderstorm, in a sun-baked car, etc.).
- To clean the device, wipe the surface with a dry cloth. Do not use harsh chemicals or detergents on the device.
- To prevent accidents, injury, and damage to the device, do not attempt to disassemble, deconstruct, or repair the device in any way.
- Even if the test result yields a permissible level, if the user feels impaired, they should not drive. The manufacturer is not responsible for any accidents that may occur from intoxication.
Alcohol Concentration Conversion Table
No.| BAC
(Blood Alcohol Concentration )
| BrAC
(Breath Alcohol concentration)
---|---|---
| %| ‰| g/l| mg/100ml| mg/l| ppm
1| 0,01| 0,1| 0,1| 10| 0,05| 25
2| 0,02| 0,2| 0,2| 20| 0,10| 50
3| 0,03| 0,3| 0,3| 30| 0,15| 75
4| 0,04| 0,4| 0,4| 40| 0,20| 100
5| 0,05| 0,5| 0,5| 50| 0,25| 125
6| 0,06| 0,6| 0,6| 60| 0,30| 150
7| 0,07| 0,7| 0,7| 70| 0,35| 175
8| 0,08| 0,8| 0,8| 80| 0,40| 200
9| 0,09| 0,9| 0,9| 90| 0,45| 225
10| 0,10| 1,0| 1,0| 100| 0,50| 250
11| 0,11| 1,1| 1,1| 110| 0,55| 275
12| 0,12| 1,2| 1,2| 120| 0,60| 300
13| 0,13| 1,3| 1,3| 130| 0,65| 325
14| 0,14| 1,4| 1,4| 140| 0,70| 350
15| 0,15| 1,5| 1,5| 150| 0,75| 375
16| 0,16| 1,6| 1,6| 160| 0,80| 400
17| 0,17| 1,7| 1,7| 170| 0,85| 425
18| 0,18| 1,8| 1,8| 180| 0,90| 450
19| 0,19| 1,9| 1,9| 190| 0,95| 475
20| 0,20| 2,0| 2,0| 200| 1,00| 500
Note: %BAC is used in the USA; g/L is used in the EU; mg/L BrAC is used in Japan; mg/100 mL is used in China; ‰BAC is used in Russia; ‰PROM is used in Poland.
Warranty Conditions
- A new product purchased in the Alza.cz sales network is guaranteed for 2 years. If you need repair or other services during the warranty period, contact the product seller directly, you must provide the original proof of purchase with the date of purchase.
- The following are considered to be a conflict with the warranty conditions, for which the claimed claim may not be recognized:
- Using the product for any purpose other than that for which the product is intended or failing to follow the instructions for maintenance, operation and service of the product.
- Damage to the product by a natural disaster, the intervention of an unauthorized person or mechanically through the fault of the buyer (e.g. during transport, cleaning by inappropriate means, etc.).
- Natural wear and aging of consumables or components during use (such as batteries, etc.).
- Exposure to adverse external influences, such as sunlight and other radiation or electromagnetic fields, fluid intrusion, object intrusion, mains overvoltage, electrostatic discharge voltage (including lightning), faulty supply or input voltage and inappropriate polarity of this voltage, chemical processes such as used power supplies, etc.
- If anyone has made modifications, modifications, alterations to the design or adaptation to change or extend the functions of the product compared to the purchased design or use of non-original components.
References
- Alza.cz – rychlý a pohodlný nákup odkudkoliv | Alza.cz
- Alza | Alza.co.uk
- Alza.cz – rychlý a pohodlný nákup odkudkoliv | Alza.cz
- Alza.cz – rychlý a pohodlný nákup odkudkoliv | Alza.cz
- Alza.cz
- alza.de
- alza.hu
- alza.sk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>