HOSHIZAKI IM-240NE Self Contained Cuber Machine Instruction Manual
- June 10, 2024
- HOSHIZAKI
Table of Contents
IM-240NE Self Contained Cuber Machine
Instruction Manual
IM-21CNE IM-30CNE IM-30CWNE IM-45CNE IM-45NE
IM-45WNE IM-65NE IM-65WNE IM-100CNE IM-100NE
IM-100WNE IM-130NE IM-130WNE IM-240NE IM-240WNE
Telford 70 Stafford Park 7, Telford, Shropshire TF3 3BQ UK
IMPORTANT SAFETY INFORMATION
Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit.
WARNING| Indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
---|---
CAUTION| Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE| Indicates a hazardous situation which, if not avoided, could
result in damage to the unit.
HYGIENE| Indicates important precautions for hygiene and food safety.
IMPORTANT| Indicates important information about the use and care of the
unit.
IMPORTANT
This booklet is an integral and essential part of the product and should be
kept and preserved by the user.
Please read carefully the guidelines and warnings contained herein as they are
intended to provide the installer/user with essential information for the
proper installation and the continued safe use and maintenance of the
product.
Please preserve this booklet for any further consultation that may be
necessary.
WARNING
This is a commercial icemaker, and should be destined only to be used for the
purpose for which it has been expressly designed.
Any other use should be considered improper and therefore dangerous. The
manufacturer will not be held liable or responsible for any damage caused by
improper, incorrect and unreasonable use.
The installation, and relocation if necessary, must be carried out by
qualified personnel, in accordance with current regulations, according to the
manufacturer’s instructions.
Keep ventilation openings, in the appliance enclosure or in the built-in
structure, clear of obstruction.
The use of any electrical appliance involves the observance of some fundamental rules. In particular:
- Instances of high humidity and moisture increase the risk of electrical short circuits and potential electrical shocks. If in doubt, disconnect the icemaker.
- Do not damage the power cord or pull it in order to disconnect the icemaker from the electrical supply network.
- If the supply cord is damaged, it must be replaced by a replacement cord available from Hoshizaki Parts/Service Centers.
- Do not touch the electrical parts or operate the switches with damp hands.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, it can however be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge providing they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
- Do not attempt to modify the icemaker. Only qualified personnel may disassemble or repair the appliance.
INSTALLATION INSTRUCTIONS
CONSTRUCTION
ACCESSORIES
| IM-21CNE| IM-30CNE IM-45CNE/NE
IM-65NE IM-100NE IM-130NE
IM-240NE| IM-30CWNE IM-45WNE IM-65WNE IM-100WNE IM-130WNE IM-240WNE| IM-100CNE
---|---|---|---|---
CD| 1| 1| 1| 1
Scoop| 1| 1| 1| 1
Inlet Hose| 1| 1| 2| 1
Outlet Hose| 1| 1| 2| 1
1/2-3/4 Nipple| –| –| 2| –
Leg| –| 4| 4| 5
Connector Cover| 1| 1| 1| 1
3/4-3/4 Nipple| –| –| –| 1
UNPACKING
WARNING
Children should not be allowed in reach of the packaging elements (plastic
bags and expanded polystyrene) as they are potential sources of danger.
CAUTION
Do not lift or maneuver the carton by using the shipping bands.
When moving the unit by hand, hold the unit bottom.
Always wear protective gloves when carrying the unit.
When handling the carton or the unpacked unit, work in pairs to prevent
injury.
NOTICE
Remove shipping carton, tape(s) and packing. If packing material is left in
the icemaker, it will not work properly.
- After removing the packaging, make sure that the icemaker is in good condition. If in doubt, please do not use the icemaker but apply to professionally qualified personnel.
- Remove the shipping tape holding the door and front panel.
- Remove the protective plastic film from the exterior. If the icemaker is exposed to the sun or to heat, remove the film after the icemaker cools.
- Remove the package of accessories. Check the contents according to “2. ACCESSORIES”.
- Remove the shipping tape holding the bin control switch by opening the bin door and reaching in.
LOCATION
WARNING
This icemaker is not intended for outdoor use.
The icemaker should not be located next to ovens, grills or other high heat
producing equipment.
This appliance is not suitable for installation in an area where a water jet
could be used.
CAUTION
The location should provide a firm and level foundation for the icemaker.
NOTICE
Do not place anything on top of the icemaker or in front of the louver.
IMPORTANT
Normal operating ambient temperature should be within 1°C to 40°C. Water
connection is cold water only. Operation of the icemaker, for extended
periods, outside of these normal temperature ranges may affect production
capacity.
Allow the clearance specified below for proper air circulation and ease of
maintenance and/or service should they be required.
[IM-45NE/WNE, 65NE/WNE, 100CNE/NE/WNE, 130NE/WNE]
In some high humidity environments, condensation may form inside the machine and drip onto the floor. Do not install where the floor can be affected by water.
INSTALLATION
CAUTION
Incorrect installation can cause harm to people, animals or other items, for
which the manufacturer cannot be held responsible.
- Place the icemaker in the selected permanent site.
[Except IM-21CNE] - When attaching the adjustable legs (accessory), level the unit in both the left-to-right and front-to-rear directions.
ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the national and local electrical
code requirements.
To prevent possible severe electrical shock to individuals or extensive damage
to the unit, install a proper earth wire to the icemaker.
Disconnect the main power supply before any maintenance, repairs or cleaning
is undertaken.
- This appliance requires a separate 220 – 240VAC, 10A [IM-21CNE, 30CNE/CWNE, 45CNE, 45NE/WNE, 65NE/WNE, 100CNE/NE/WNE, 130NE/WNE] / 13A [IM-240NE/WNE] supply. The electrical supply must be protected by a suitable circuit breaker.
- The main control box fuse is rated at 5A and should only be replaced by a qualified service engineer.
- Usually an electrical permit and services of a licensed electrician are required.
[IM-240NE/WNE]
- In accordance with the requirement of the IEC standard, the maximum permissible system impedance (Amax) at the interface point of the power supply to be connected with this icemaker must be 0.23+j0.23 ohm. Determine in consultation with the supply authority, if necessary, that the icemaker is connected only to a supply of 0.23+j0.23 ohm or less.
For the U.K. and the Republic of Ireland only
- The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colour of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured Green-and-Yellow must be connected to the terminal in the plug which is marked with the letter E or by the symbol or coloured Green or Green- and-Yellow. The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black. The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red. - Should the socket outlets in the installation site not be suitable for the plug supplied with your product, the plug must be removed (cut off if it is molded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power supply cord, it must be disposed of. There should be no attempt to reuse it. Inserting such a plug into a socket elsewhere presents a serious risk of electrical shock. - The non-rewirable plug must never be used without a fuse cover being fitted.
The correct replacement for the detachable fuse cover is identifiable from the manufacturer’s reference number stamped on the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki Parts/Service Centers.
Fuses should be rated at 13A and approved to BS 1362.
WATER SUPPLY AND DRAIN CONNECTIONS
WARNING
Connect to potable cold water supply only.
-
The connections to the mains water supply must be made in accordance with the countries’ current requirements of the Water Supply or Water Fittings Regulations.
-
Icemaking water must be potable water. Where scaling can be caused by water quality:
– Installation of an external filter or softener is recommended. Contact your local water treatment professional or Hoshizaki service agent.
– Change to the “full drain flush” mode is recommended. Contact your local Hoshizaki service agent. -
Water supply pressure should be minimum 0.07 MP (0.7 bar) and maximum 0.78 MPa (8 bar). If the pressure exceeds 0.78 MPa (8 bar), use a proper pressure reducing valve. Do NOT throttle back the supply tap.
-
A plumbing permit and services of a licensed plumber may be required in some areas.
-
The icemaker drain is gravity flow, so ensure drain hose has an adequate pitch or fall.
-
Drain lines should not be installed directly to the sewer system. A vertical air gap of a minimum of 5 cm should be between the end of the drain hoses from the icemaker and the floor drain.
-
To prevent a backflow into the storage bin, the outlet hose must be laid as shown.
-
On water-cooled model, a back flow preventer may be required in the cooling water circuit.
-
Be sure to use the new hose-sets supplied with the appliance. Do not reuse any old hose-sets.
[Air-Cooled Model]
- Attach the angled end of flexible inlet hose (accessory) to the G3/4 fitting on the rear of the icemaker as indicated, ensuring rubber sealing washer is correctly positioned. Hand tighten sufficiently to provide leak free joint.
- Attach the other end of inlet hose to the water tap, noting washer is correctly positioned before hand tightening as above. It is a wise precaution to have a stop valve within easy reach.
- [Except IM-100CNE] Hand tighten grey flexible outlet hose (accessory) onto the R3/4 fitting on the rear of the icemaker as indicated, ensuring rubber washer is correctly positioned to obtain a leak free joint. The hose can be cut to length as necessary to suit position of main drain.
[IM-100CNE]
By means of a suitable spanner or wrench, tighten the 3/4-3/4 nipple
(accessory) into the Rc3/4fitting on the bottom of the icemaker as
indicated.P.T.F.E. tape and/or a suitable sealing compound should be used to
obtain a leak free joint.
Note: Jointing compounds should be approved and suitable for potable
water use.
Hand tighten grey flexible outlet hose (accessory) onto the 3/4-3/4 nipple as
indicated, ensuring rubber washer is correctly positioned to obtain a leak
free joint. The hose can be cut to length as necessary to suit position of
main drain.
[Water-Cooled Model]
- Hoshizaki recommends that the water-cooled condenser should be connected to a closed circuit recirculating type cooling system utilizing a tower, water chiller or similar. Water make up should be via a ball valve/break tank arrangement.
- Whilst connecting a water-cooled condenser to a mains water (potable) supply will not affect the performance of the machine, it will most certainly cause a high use/waste of a valuable resource and is not recommended.
- The services of a licensed or coded plumber should be used to ensure a correct installation.
- The connections should be made properly in compliance with the applicable national or local regulations.
[a] Standard connections according to WRAS regulations in U.K.
- When selecting a cooling tower, refer to the following peak values of heat flow in the condenser:
Model
IM-30CW/45W: | 295 – 760W |
---|---|
IM-65W: | 875W |
IM-100/130W: | 1165W |
IM-240W: | 5235W |
- Pipes between the cooling tower and the icemaker should be at least 20 mm DIA to reduce pressure loss, even though the icemaker fittings are 13 mm DIA.
- Pressure loss in the water circuit inside the unit will be 5 to 6 m when the cooling water flows at the ratio of 4 to 5 lit/min.
- Select a circulating pump referring to the above values of heat flow.
- Do not use a cascade pump, or the water regulator will vary the flow and stop it during the defrost cycle.
[Icemaker Connections]
-
Attach the angled end of flexible inlet hose (accessory) to the G3/4 fitting on the rear of the icemaker as indicated, ensuring rubber sealing washer is correctly positioned. Hand tighten sufficiently to provide leak free joint.
-
Attach the other end of inlet hose to the water tap, noting washer is correctly positioned before hand tightening as above.
Note: If filtration or treatment is used, ensure icemaker section only is on treated water supply, not the condenser. -
Attach grey flexible outlet hose (accessory) to the R3/4 fitting on the rear of the icemaker as indicated, confirming fitment of rubber washer before finally hand tightening the joint. The hose can be cut to length as necessary to suit position of main drain.
-
By means of a suitable spanner or wrench, tighten the 1/2-3/4 nipples (accessory) into the Rc1/2 fittings on the rear of the icemaker as indicated. P.T.F.E. tape and/or a suitable sealing compound should be used to obtain a leak free joint.
Note: Jointing compounds should be approved and suitable for potable water use. -
Connect the condenser cooling circuit to the free end of 1/2-3/4 nipples as indicated using a suitable rigid type pipe.
[b] Connections according to regulations other than WRAS by utilizing accessory hoses
- Follow the instructions from 1) to 4) in [a] above.
- For condenser connections, use supplied accessory hoses and make the same connections as 1) to 3) in [a] above to the free end of 1/2-3/4 nipples as indicated.
OPERATING INSTRUCTIONS
CAUTION
Do not put your hands into the back of the storage bin or the ice chute on top
of the storage bin. Ice may drop off the icemaker, a hard block of ice may
suddenly break down, or the icemaking mechanism may suddenly move, resulting
in injury.
NOTICE
All parts are factory-adjusted. Improper adjustments may result in failure.
If the unit is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
HYGIENE
This icemaker is designed to produce edible ice. To keep the icemaker
hygienic:
- Wash your hands before removing ice. Use the plastic scoop provided (accessory).
- The storage bin is for ice use only. Do not store anything else in the bin nor use other electrical appliances in the bin.
- Clean the storage bin before use (see “III. 1. CLEANING”).
- Keep the scoop clean. Clean it by using a neutral cleaner and rinse thoroughly.
- Close the door after removing ice to prevent entrance of dirt, dust or insects into the storage bin.
START UP
The installer will normally commission the icemaker to start the automatic icemaking process. To ensure continuous operation, make sure that:
- The water supply tap is on, and
- The icemaker is connected to the power supply.
PREPARING THE ICEMAKER FOR LONG STORAGE
NOTICE
This icemaker will not work at subfreezing temperatures. To prevent damage to
the water supply line, drain the icemaker when air temperature is below zero.
HYGIENE
When shutting down the icemaker for two or more days, drain the icemaker to
prevent contamination in the water circuit.
- Unplug the icemaker or disconnect the power supply.
- Close the water supply tap, and remove the inlet hose.
- Remove all ice from the storage bin, and clean the bin.
- Ask for draining of the icemaker by professional qualified personnel.
MAINTENANCE
CLEANING
WARNING
Before carrying out any cleaning or maintenance operations, unplug the
icemaker from the electrical supply network.
This appliance must not be cleaned by use of a water jet.
CAUTION
When using a neutral cleaner or sodium hypochlorite, thoroughly read and
understand the instructions provided to prevent potential health problems.
NOTICE
Ask a trained service person to clean and sanities the icemaker water system
at least twice a year and to check and clean the condenser at least once a
year.
To prevent possible damage, do not clean the plastic parts with water above
40°C or in a dishwasher.
[a] Machine and Bin Exterior
Wipe the exterior at least once per week with a clean, soft cloth. Use a damp
cloth containing a neutral cleaner to wipe off grease or dirt.
[b] Scoop and Storage Bin Handle Cleaning/Sanitisation (Daily)
-
Either mix 1 litter of water with 4 ml of 5.25% sodium hypochlorite solution in a suitable container, or the recommended Hoshizaki sanitiser as directed.
-
Soak the scoop in the solution for more than 3 minutes. Rinse thoroughly, and shake to remove surplus liquid.
Note: Using a cloth to dry may re-contaminate. -
Use a neutral cleaner to wash the storage bin handle. Rinse thoroughly.
-
Soak a clean cloth with the sanitizing solution, and wipe the handle. Use fresh water and a clean cloth to rinse/dry.
[c] Storage Bin Interior Cleaning/Sanitization (Weekly)
-
Open the storage bin door, and remove all ice.
-
Wash the bin liner with a neutral non-abrasive cleaner. Rinse thoroughly.
-
Soak a clean cloth with the neutral cleaner, and wipe both sides of the slope and the door inner surface. Wipe off the cleaner with a clean damp cloth.
-
Either mix 5 liters of water with 18 ml of 5.25% sodium hypochlorite solution in a suitable container, or the recommended
Hoshizaki sanitizer as directed. -
Soak a clean sponge or cloth with the solution, and wipe the bin liner, bin door and slope.
-
The remaining solution can be used to sanities utensils.
Note: Do not wipe dry or rinse after sanitising, but allow to air dry.
[d] Air Filter (Air-Cooled Model Only)
Plastic mesh air filters remove dirt or dust from the air, and keep the
condenser from getting clogged. If the filters get clogged, the icemaker’s
performance will be reduced. Remove and clean the air filter(s) at least
twice per month:
- Slide the air filter off the filter guide [IM-21CNE/30CNE] or the louver [IM-45CNE/45NE/65NE/100CNE/100NE/130NE/240NE].
- Clean the air filter by using a vacuum cleaner. When severely clogged, use warm water and a neutral cleaner to wash the air filter.
- Rinse and dry the air filter thoroughly.
NOTICE
After cleaning, be sure to place the air filter back in position.
BEFORE CALLING FOR SERVICE
WARNING
Do not damage the refrigerant circuit.
[a] Error Code Indication
If the error code “E” is indicated on the display, before calling for service,
check the following.
Code | Remedy |
---|---|
E1 | Freeze error. Unplug unit and plug it back in after 3 minutes. Clean |
air filter (air-cooled model). Lower ambient temperature or ensure adequate
clearance around unit (see “I. 4. LOCATION”). If error persists, call for
service.
E2| Defrost error. Unplug unit and plug it back in after 3 minutes. If
error persists, call for service.
EE| Other error. Unplug unit and plug it back in after 3 minutes. Clean
air filter (air-cooled model). Check for water failure or closed water supply
tap. Lower ambient temperature or ensure adequate clearance around unit (see
“I. 4. LOCATION”). If error persists, call for service.
[b] No Error Code Indication
If the icemaker does not work properly or does not work at all and no error
code is indicated on the display, before calling for service, check that:
- The power is supplied to the unit.
- The water is turned on.
- The air filter is clean (air-cooled model).
- The cooling water circuit has a proper flow (water-cooled model).
For further assistance or advice, contact your local Hoshizaki service agent.
DISPOSAL
Comply with local regulations regarding disposal of this appliance and its
refrigerant gas. Before you scrap the appliance, take off the door to prevent
children becoming trapped.
Correct disposal of this product:
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, use the return and collection systems or contact the
retailer where the product was purchased. They can take this product for
environmental safe recycling.
WARRANTY
Hoshizaki warrants to the original owner/user that all Hoshizaki branded
products shall be free of defects in material and/or workmanship for the
duration of the “warranty period”. The warranty shall be effective for two
years from the date of installation.
Hoshizaki’s liability under the terms of the warranty are limited and shall
exclude routine servicing, cleaning, essential maintenance and/or repairs
occasioned by misuse and installations not in accordance with Hoshizaki
guidelines.
Warranty repairs should be completed by an approved Hoshizaki dealer or
service agency using genuine Hoshizaki components.
To obtain full details of your warranty and approved service agency, please
contact your dealer/supplier, or the nearest Hoshizaki Service office:
Europe, Middle East, Africa
Hoshizaki UK – UK, Ireland
TEL: +44 845 456 0585
FAX: +44 132 283 8331
uksales@hoshizaki.uk| Hoshizaki Middle East
– Middle East
TEL: +971 48 876 612
FAX: +971 48 876 613
sales@hoshizaki.ae
---|---
Hoshizaki Deutschland – Germany, Switzerland, Austria,
Poland, Czech Republic, Slovakia
TEL: +49 5121 697370
FAX: +49 5121 6973719
vertrieb@hoshizaki.de| Hoshizaki Benelux –
Netherlands, Belgium, Luxembourg
Tel: +31 85 018 83 70
info@hoshizaki.nl
Hoshizaki Benelux – Netherlands, Belgium, Luxembourg
Tel: +31 85 018 83 70
info@hoshizaki.nl| Hoshizaki Italia – Italy
TEL: +39 344 0616467
TEL: +39 348 3022156
info@hoshizaki.it
Hoshizaki Iberia – Spain, Portugal
TEL: +34 93 478 09 52
FAX: +34 93 478 08 00
info@hoshizaki.es| Hoshizaki Europe B.V. – all
other countries within Europe and Africa
TEL: +31 20 6918499
FAX: +31 20 6918768
sales@hoshizaki.nl
Asia, Oceania
Hoshizaki Singapore
TEL: +65 6225 2612
FAX: +65 6225 3219
sales@hoshizaki.com.sg (Sales)
serviceadmin@hoshizaki.com.sg
(Technical support)| Hoshizaki Hong Kong
TEL: +852 2866-2108
FAX: +852 2866-2109
Hoshizaki Taiwan
TEL: +886 2 2706 8818
FAX: +886 2 2708 7999
SPECIFICATIONS
Model | IM-21CNE | IM-30CNE | IM-30CWNE |
---|---|---|---|
Type | Air-cooled, cube ice | Air-cooled, cube ice | Water-cooled, cube ice |
Power Supply | 1 phase 220 – 240V 50Hz | 1 phase 220 – 240V 50Hz | 1 phase 220 – |
240V 50Hz
Electric Consumption| 240W| 270W| 245W
Ice Production per 24h| 20kg (5mm) / 22kg (15mm) (ambient 10°C, water 10°C)|
23kg (5mm) / 28kg (15mm) (ambient 10°C, water 10°C)| 28kg (5mm) / 32kg (15mm)
(ambient 10°C, water 10°C)
Dimensions| 398mm(W) x 451mm(D) x 695mm(H)| 398mm(W) x 451mm(D) x 695mm(H)|
398mm(W) x 451mm(D) x 695mm(H)
Refrigerant| R134a, 0.11kg (GWP: 1430, CO2: 0.157t)| R134a, 0.13kg (GWP: 1430,
CO2: 0.186t)| R134a, 0.18kg (GWP: 1430, CO2: 0.257t)
Insulation Foam Blowing Agent| HFC-free| HFC-free| HFC-free
Weight| Net: 34kg (Gross: 38kg)| Net: 34kg (Gross: 38kg)| Net: 35kg (Gross:
39kg)
Ambient Temp| 1 – 40°C| 1 – 40°C| 1 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.07 – 0.78 MPa (0.7 – 8 bar)| 0.07 – 0.78 MPa (0.7 – 8
bar)| 0.07 – 0.78 MPa (0.7 – 8 bar)
Voltage Range| Rated voltage ± 6%| Rated voltage ± 6%| Rated voltage ± 6%
Model| IM-45CNE| IM-45NE| IM-45WNE
---|---|---|---
Type| Air-cooled, cube ice| Air-cooled, cube ice| Water-cooled, cube ice
Power Supply| 1 phase 220 – 240V 50Hz| 1 phase 220 – 240V 50Hz| 1 phase 220 –
240V 50Hz
Electric Consumption| 320W| 330W| 295W
Ice Production per 24h| 36kg (5mm) / 44kg (15mm) (ambient 10°C, water 10°C)|
36kg (5mm) / 44kg (15mm) (ambient 10°C, water 10°C)| 45kg (5mm) / 47kg (15mm)
(ambient 10°C, water 10°C)
Dimensions| 633mm(W) x 511mm(D) x 690mm(H)| 503mm(W) x 456mm(D) x 840mm(H)|
503mm(W) x 456mm(D) x 840mm(H)
Refrigerant| R134a, 0.16kg
(GWP: 1430, CO2: 0.229t)| R134a, 0.16kg
(GWP: 1430, CO2: 0.229t)| R134a, 0.21kg
(GWP: 1430, CO2: 0.300t)
Insulation Foam Blowing Agent| HFC-free| HFC-free| HFC-free
Weight| Net: 48kg (Gross: 55kg)| Net: 46kg (Gross: 51kg)| Net: 47kg (Gross:
52kg)
Ambient Temp| 1 – 40°C| 1 – 40°C| 1 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.07 – 0.78 MPa (0.7 – 8 bar)| 0.07 – 0.78 MPa (0.7 – 8
bar)| 0.07 – 0.78 MPa (0.7 – 8 bar)
Voltage Range| Rated voltage ± 6%| Rated voltage ± 6%| Rated voltage ± 6%
Model| IM-65NE| IM-65WNE
---|---|---
Type| Air-cooled, cube ice| Water-cooled, cube ice
Power Supply| 1 phase 220 – 240V 50Hz| 1 phase 220 – 240V 50Hz
Electric Consumption| 400W| 370W
Ice Production per 24h| 50kg (5mm) / 63kg (15mm) (ambient 10°C, water 10°C)|
50kg (5mm) / 63kg (15mm) (ambient 10°C, water 10°C)
Dimensions| 633mm(W) x 506mm(D) x 840mm(H)| 633mm(W) x 506mm(D) x 840mm(H)
Refrigerant| R134a, 0.25kg
(GWP: 1430, CO2: 0.358t)| R134a, 0.25kg
(GWP: 1430, CO2: 0.358t)
Insulation Foam Blowing Agent| HFC-free| HFC-free
Weight| Net: 53kg (Gross: 60kg)| Net: 54kg (Gross: 61kg)
Ambient Temp| 1 – 40°C| 1 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.07 – 0.78 MPa (0.7 – 8 bar)| 0.07 – 0.78 MPa (0.7 – 8
bar)
Voltage Range| Rated voltage ± 6%| Rated voltage ± 6%
Model| IM-100CNE| IM-100NE| IM-100WNE
---|---|---|---
Type| Air-cooled, cube ice| Air-cooled, cube ice| Water-cooled, cube ice
Power Supply| 1 phase 220 – 240V 50Hz| 1 phase 220 – 240V 50Hz| 1 phase 220 –
240V 50Hz
Electric Consumption| 630W| 630W| 540W
Ice Production per 24h| 85kg (5mm) / 95kg (15mm) (ambient 10°C, water 10°C)|
85kg (5mm) / 95kg (15mm) (ambient 10°C, water 10°C)| 90kg (5mm) / 97kg (15mm)
(ambient 10°C, water 10°C)
Dimensions| 1004mm(W) x 600mm(D) x 800mm(H)| 704mm(W) x 506mm(D) x 1200mm(H)|
704mm(W) x 506mm(D) x 1200mm(H)
Refrigerant| R134a, 0.29kg
(GWP: 1430, CO2: 0.415t)| R134a, 0.29kg
(GWP: 1430, CO2: 0.415t)| R134a, 0.38kg
(GWP: 1430, CO2: 0.543t)
Insulation Foam Blowing Agent| HFC-free| HFC-free| HFC-free
Weight| Net: 77kg (Gross: 88kg)| Net: 76kg (Gross: 84kg)| Net: 74kg (Gross:
82kg)
Ambient Temp| 1 – 40°C| 1 – 40°C| 1 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.07 – 0.78 MPa (0.7 – 8 bar)| 0.07 – 0.78 MPa (0.7 – 8
bar)| 0.07 – 0.78 MPa (0.7 – 8 bar)
Voltage Range| Rated voltage ± 6%| Rated voltage ± 6%| Rated voltage ± 6%
Model| IM-130NE| IM-130WNE
---|---|---
Type| Air-cooled, cube ice| Water-cooled, cube ice
Power Supply| 1 phase 220 – 240V 50Hz| 1 phase 220 – 240V 50Hz
Electric Consumption| 700W| 640W
Ice Production per 24h| 100kg (5mm) / 120kg (15mm) (ambient 10°C, water 10°C)|
110kg (5mm) / 127kg (15mm) (ambient 10°C, water 10°C)
Dimensions| 704mm(W) x 506mm(D) x 1200mm(H)| 704mm(W) x 506mm(D) x 1200mm(H)
Refrigerant| R404A, 0.38kg
(GWP: 3920, CO2: 1.490t)| R404A, 0.45kg
(GWP: 3920, CO2: 1.764t)
Insulation Foam Blowing Agent| HFC-free| HFC-free
Weight| Net: 76kg (Gross: 84kg)| Net: 74kg (Gross: 82kg)
Ambient Temp| 1 – 40°C| 1 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.07 – 0.78 MPa (0.7 – 8 bar)| 0.07 – 0.78 MPa (0.7 – 8
bar)
Voltage Range| Rated voltage ± 6%| Rated voltage ± 6%
Model| IM-240NE| IM-240WNE
---|---|---
Type| Air-cooled, cube ice| Water-cooled, cube ice
Power Supply| 1 phase 220 – 240V 50Hz| 1 phase 220 – 240V 50Hz
Electric Consumption| 1320W| 1300W
Ice Production per 24h| 220kg (5mm) / 240kg (15mm) (ambient 10°C, water 10°C)|
230kg (5mm) / 240kg (15mm) (ambient 10°C, water 10°C)
Dimensions| 704mm(W) x 665mm(D) x 1510mm(H)| 704mm(W) x 665mm(D) x 1510mm(H)
Refrigerant| R404A, 0.50kg
(GWP: 3920, CO2: 1.960t)| R404A, 0.47kg
(GWP: 3920, CO2: 1.842t)
Insulation Foam Blowing Agent| HFC-free| HFC-free
Weight| Net: 111kg (Gross: 122kg)| Net: 120kg (Gross: 131kg)
Ambient Temp| 1 – 40°C| 1 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.07 – 0.78 MPa (0.7 – 8 bar)| 0.07 – 0.78 MPa (0.7 – 8
bar)
Voltage Range| Rated voltage ± 6%| Rated voltage ± 6%
Model| IM-30CNE| IM-30CWNE
---|---|---
Type| Air-cooled, cube ice| Water-cooled, cube ice
Power Supply| 1 phase 220 – 230V 60Hz| 1 phase 220 – 230V 60Hz
Electric Consumption| 270W| 245W
Ice Production per 24h| 24kg (5mm) / 27kg (15mm) (ambient 10°C, water 10°C)|
24kg (5mm) / 27kg (15mm) (ambient 10°C, water 10°C)
Dimensions| 398mm(W) x 451mm(D) x 695mm(H)| 398mm(W) x 451mm(D) x 695mm(H)
Refrigerant| R134a, 0.14kg
(GWP: 1430, CO2: 0.200t)| R134a, 0.18kg
(GWP: 1430, CO2: 0.257t)
Insulation Foam Blowing Agent| HFC-free| HFC-free
Weight| Net: 34kg (Gross: 38kg)| Net: 35kg (Gross: 39kg)
Ambient Temp| 1 – 40°C| 1 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.07 – 0.78 MPa (0.7 – 8 bar)| 0.07 – 0.78 MPa (0.7 – 8
bar)
Voltage Range| Rated voltage ± 10%| Rated voltage ± 10%
Model| IM-45CNE| IM-45NE| IM-45WNE
---|---|---|---
Type| Air-cooled, cube ice| Air-cooled, cube ice| Water-cooled, cube ice
Power Supply| 1 phase 220 – 230V 60Hz| 1 phase 220 – 230V 60Hz| 1 phase 220 –
230V 60Hz
Electric Consumption| 360W| 360W| 310W
Ice Production per 24h| 41kg (5mm) / 46kg (15mm) (ambient 10°C, water 10°C)|
41kg (5mm) / 46kg (15mm) (ambient 10°C, water 10°C)| 45kg (5mm) / 50kg (15mm)
(ambient 10°C, water 10°C)
Dimensions| 633mm(W) x 511mm(D) x 690mm(H)| 503mm(W) x 456mm(D) x 840mm(H)|
503mm(W) x 456mm(D) x 840mm(H)
Refrigerant| R134a, 0.16kg
(GWP: 1430, CO2: 0.229t)| R134a, 0.16kg
(GWP: 1430, CO2: 0.229t)| R134a, 0.21kg
(GWP: 1430, CO2: 0.300t)
Insulation Foam Blowing Agent| HFC-free| HFC-free| HFC-free
Weight| Net: 48kg (Gross: 55kg)| Net: 46kg (Gross: 51kg)| Net: 47kg (Gross:
52kg)
Ambient Temp| 1 – 40°C| 1 – 40°C| 1 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.07 – 0.78 MPa (0.7 – 8 bar)| 0.07 – 0.78 MPa (0.7 – 8
bar)| 0.07 – 0.78 MPa (0.7 – 8 bar)
Voltage Range| Rated voltage ± 10%| Rated voltage ± 10%| Rated voltage ± 10%
Model| IM-65NE| IM-65WNE
---|---|---
Type| Air-cooled, cube ice| Water-cooled, cube ice
Power Supply| 1 phase 220 – 230V 60Hz| 1 phase 220 – 230V 60Hz
Electric Consumption| 370W| 310W
Ice Production per 24h| 55kg (5mm) / 62kg (15mm) (ambient 10°C, water 10°C)|
57kg (5mm) / 65kg (15mm) (ambient 10°C, water 10°C)
Dimensions| 633mm(W) x 506mm(D) x 840mm(H)| 633mm(W) x 506mm(D) x 840mm(H)
Refrigerant| R134a, 0.22kg
(GWP: 1430, CO2: 0.315t)| R134a, 0.25kg
(GWP: 1430, CO2: 0.358t)
Insulation Foam Blowing Agent| HFC-free| HFC-free
Weight| Net: 53kg (Gross: 60kg)| Net: 54kg (Gross: 61kg)
Ambient Temp| 1 – 40°C| 1 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.07 – 0.78 MPa (0.7 – 8 bar)| 0.07 – 0.78 MPa (0.7 – 8
bar)
Voltage Range| Rated voltage ± 10%| Rated voltage ± 10%
Model| IM-100CNE| IM-100NE| IM-100WNE
---|---|---|---
Type| Air-cooled, cube ice| Air-cooled, cube ice| Water-cooled, cube ice
Power Supply| 1 phase 220 – 230V 60Hz| 1 phase 220 – 230V 60Hz| 1 phase 220 –
230V 60Hz
Electric Consumption| 650W| 650W| 600W
Ice Production per 24h| 88kg (5mm) / 98kg (15mm) (ambient 10°C, water 10°C)|
88kg (5mm) / 98kg (15mm) (ambient 10°C, water 10°C)| 95kg (5mm) / 104kg (15mm)
(ambient 10°C, water 10°C)
Dimensions| 1004mm(W) x 600mm(D) x 800mm(H)| 704mm(W) x 506mm(D) x 1200mm(H)|
704mm(W) x 506mm(D) x 1200mm(H)
Refrigerant| R134a, 0.29kg
(GWP: 1430, CO2: 0.415t)| R134a, 0.28kg
(GWP: 1430, CO2: 0.400t)| R134a, 0.38kg
(GWP: 1430, CO2: 0.543t)
Insulation Foam Blowing Agent| HFC-free| HFC-free| HFC-free
Weight| Net: 77kg (Gross: 88kg)| Net: 76kg (Gross: 84kg)| Net: 74kg (Gross:
82kg)
Ambient Temp| 1 – 40°C| 1 – 40°C| 1 – 40°C
Water Supply Temp| 5 – 35°C| 5 – 35°C| 5 – 35°C
Water Supply Pressure| 0.07 – 0.78 MPa (0.7 – 8 bar)| 0.07 – 0.78 MPa (0.7 – 8
bar)| 0.07 – 0.78 MPa (0.7 – 8 bar)
Voltage Range| Rated voltage ± 10%| Rated voltage ± 10%| Rated voltage ± 10%
Note: The above specifications are for the representative models.
This product includes a hermetically sealed refrigeration system that contains
fluorinated greenhouse gases.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>