Altronix ALTV248UL CCTV Power Supplies User Manual

June 10, 2024
Altronix

Altronix ALTV248UL CCTV Power Supplies

Product Information

The ALTV248UL Series CCTV Power Supplies are designed to provide 24VAC or 28VAC to power CCTV cameras, heaters, and other video accessories. These power supplies come in different models that offer various output currents and protection methods. All models have eight outputs that are either fuse or PTC protected. Some models are Class 2 rated for dry locations, while others are Class 3 rated for wet locations. The power supplies have individual output currents that should not exceed the total output current.

The ALTV248UL Series CCTV Power Supplies are UL Listed and CUL Listed, ensuring that they meet safety standards set by regulatory agencies. The power supplies are designed for indoor use only and should be installed in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI and local codes and authorities having jurisdiction.

Product Usage Instructions

Before using the ALTV248UL Series CCTV Power Supplies, make sure to read and understand the installation guide provided in the user manual.

  1. Choose a suitable location for the power supply and mount it on the wall using the top two keyholes.
  2. Connect the power supply to a 115VAC 60Hz power source.
  3. Identify the distribution module terminal, which is labeled PD4/PD4CB.
  4. Connect the CCTV cameras, heaters, and other video accessories to the eight outputs of the power supply. Make sure that the total output current does not exceed the maximum current specified for the chosen model.
  5. If the chosen model has fuse-protected outputs, make sure to use fuses with the correct rating. The main fuse and primary in-line fuse ratings are specified in the reference chart provided in the user manual.
  6. If the chosen model has PTC-protected outputs, there is no need to use fuses. The PTCs are autoresettable and provide protection against overcurrent and short circuits.
  7. The ALTV248UL Series CCTV Power Supplies are now ready to be used.

Models Include

  • ALTV248UL
    • 24VAC @ 3.5A (85VA) or 28VAC @ 3A (85VA).
    • Eight (8) Fuse Protected Outputs.
  • ALTV248175UL
    • 24VAC @ 7A (175VA) or 28VAC @ 6.25A (175VA).
    • Eight (8) Fuse Protected Outputs.
  • ALTV248300UL
    • 24VAC @ 12.5A (300VA) or 28VAC @ 10A (280VA).
    • Eight (8) Fuse Protected Outputs.
  • ALTV248300ULM
    • 24VAC @ 12.5A (300VA) or 28VAC @ 10A (280VA).
    • Eight (8) Fuse Protected Outputs.
  • ALTV248600UL
    • 24VAC @ 25A (600VA) or 28VAC @ 20A (560VA).
    • Eight (8) Fuse Protected Outputs.
  • ALTV248ULCB
    • 24VAC @ 3.5A (85VA) or 28VAC @ 3A (85VA).
    • Eight (8) PTC Protected Outputs.
  • ALTV248175ULCB
    • 24VAC @ 7A (175VA) or 28VAC @ 6.25A (175VA).
    • Eight (8) PTC Protected Outputs.
  • ALTV248300ULCB
    • 24VAC @ 12.5A (300VA) or 28VAC @ 10A (280VA).
    • Eight (8) PTC Protected Outputs.
  • ALTV248300ULCBM
    • 24VAC @ 12.5A (300VA) or 28VAC @ 10A (280VA).
    • Eight (8) PTC Protected Outputs.
  • ALTV248600ULCB
    • 24VAC @ 25A (600VA) or 28VAC @ 20A (560VA).
    • Eight (8) PTC Protected Outputs.

Overview

Altronix ALTV248UL Series CCTV Power Supplies provide 24VAC or 28VAC distributed via eight (8) fuse or PTC protected outputs for powering CCTV cameras, heaters and other video accessories.

Eight (8) Output ALTV248UL Reference Chart

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-1

Specifications

Agency Listings

  • UL Listed for Commercial CCTV Equipment (UL 2044). CUL Listed – CSA Standard C22.2 No.1-98, Audio, Video and Similar Equipment.
  • CE European Conformity.

Input:

  • * 115VAC, 50/60Hz.
  • Output:
    • Eight (8) fuse or PTC protected outputs.
    • 24VAC or 28VAC output
    • Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
    • Surge suppression.
  • Features:
    • AC power LED indicator.
    • Power ON/OFF switch (ALTV248UL, ALTV248ULCB).
    • Illuminated power disconnect circuit breaker with manual reset (all other models).Features (cont’d):
    • Unit maintains camera synchronization.
    • Ease of installation saves time and eliminates costly labor.
    • Spare fuses included (on fuse protected models).

Enclosure Dimensions (H x W x D):

  • ALTV248UL and ALTV248ULCB:
    • 8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)
  • ALTV248300ULM and ALTV248300ULCBM:
    • 8.5” x 7.5” x 3.875” (215.9mm x 191mm x 98.4mm).

ALTV248175UL, ALTV248175ULCB,

  • ALTV248300UL, and ALTV248300ULCB:
    • 12” x 7.5” x 4.5” (304.8mm x 190.5mm x 114.3mm).
  • ALTV248600UL and ALTV248600ULCB:
    • 13.5” x 13” x 3.25”
    • (342.9mm x 330.2mm x 82.6mm).

Installation Instructions

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only.

  1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, Pg. 14-16). Secure enclosure to earth ground.

  2. Set power switch on power distribution board marked [PD] to OFF position for models ALTV248UL or ALTV248ULCB (Fig. 1a, 2a, Pg. 4, 5). Set power disconnect circuit breaker to OFF position for all  other models (Fig. 3a – 10a, Pg. 6-13).

  3. All units are factory set for 24VAC operation.
    For 28VAC operation adjust unit prior to mounting and applying power as follows:
    Change the wire position so that the wire marked [28V] is connected to the terminal marked [P] and the wire marked [24V] is connected to the terminal marked [S].
    Note: ALTV248ULCB set for 28VAC operation is not Class 2 Rated, not power-limited.

  4. Connect AC power to the black and white flying leads of the transformer(s) (Fig. 1-10, Pg. 4-13), secure green lead to earth ground. Use 18 AWG or larger for all power connections.
    Keep power-limited (PTC protected outputs only) wiring separate from non power-limited wiring. Minimum 0.25” spacing must be provided. Use separate knockouts.

  5. Set power switch on power distribution board marked [PD] to ON position for models ALTV248UL or ALTV248ULCB (Fig. 1a, 2a, Pg. 4, 5). Set power disconnect circuit breaker to RESET (ON) position for all other models (Fig. 3a-10a, Pg. 6-13).

  6. Measure output voltage before connecting devices. This helps avoiding potential damage.
    Terminals marked [1P] – [8P] are of the same polarity.
    CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the output voltage.

  7. Set power switch on power distribution board marked [PD] to OFF position for models ALTV248UL or ALTV248ULCB (Fig. 1a, 2a, Pg. 4, 5). Set power disconnect circuit breaker to OFF position for all other models (Fig. 3a-10a, Pg. 6-13).

  8. Connect devices to terminals marked [1P] – [1N] through [4P] – [4N] on PD4/PD4CB board (Fig. 9, 10, Pg. 12, 13) or terminals marked [1P] – [1N] through [8P] – [8N] on PD8/PD8CB board (Fig. 1-8, Pg. 4-12), carefully observing polarity.

  9. Set power switch on power distribution board marked [PD] to ON position for models ALTV248UL or ALTV248ULCB (Fig. 1a, 2a, Pg. 4, 5). Set power disconnect circuit breaker to RESET (ON) position for all other models (Fig. 3a-10a, Pg. 6-13).

  10. Green LED will illuminate when power is present.

  11. Upon completion of wiring, secure enclosure door with screws (supplied). Installation of cam lock is optional. Caution: Equipment to be installed/serviced by authorized/trained personnel only. Shut branch circuit power before installing/servicing equipment.

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes. Use 75˚C or higher rated UL insulated wiring for connecting the unit to the mains. Replace fuses with the same type and rating (refer to Eight (8) Output ALTV248UL Reference Chart, pg. 2).

Terminal Identification

PD4/PD4CB – Distribution Module

  • 1P – 4P AC output.
  • 1N – 4N AC output.

PD8/PD8CB – Distribution Module

  • 1P – 8P AC output.
  • 1N – 8N AC output.

CAUTION: The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s WARNING: enclosure that may be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of impor-tant operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.

ALTV248U

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-2

ALTV248ULCB

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-3

Voltage Selection Configuration

ALTV248175UL

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-5

Voltage Selection Configuration

ALTV248175ULCB

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-7

Voltage Selection Configuration

ALTV248300UL

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-9

Voltage Selection Configuration

ALTV248300ULCB

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-11

Voltage Selection Configuration

ALTV248300ULM

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-13

Voltage Selection Configuration

ALTV248300ULCBM

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-15

Voltage Selection Configuration

ALTV248600UL

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-17

Voltage Selection Configuration

ALTV248600ULCB

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-19

Voltage Selection Configuration

Enclosure Dimensions (H x W x D):

  • ALTV248UL
  • ALTV248ULCB: 8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-21

  • ALTV248300ULM
  • ALTV248300ULCBM: 8.5” x 7.5” x 3.875” (215.9mm x 191mm x 98.4mm)

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-22

  • ALTV248175UL
  • ALTV248175ULCB
  • ALTV248300UL
  • ALTV248300ULCB: 12” x 7.5” x 4.5” (304.8mm x 190.5mm x 114.3mm)

Altronix-ALTV248UL-CCTV-Power-Supplies-fig-23

  • ALTV248600UL
  • ALTV248600ULCB: 13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)Altronix-ALTV248UL-CCTV-Power-Supplies-fig-24

CONTACT

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals