The PCE-LCM 50 Digital Microscope is a high-performance microscope that can be used for various applications. It comes with a range of features that make it easy to use and highly effective. Below are some of the key specifications of the microscope:

Product Specifications

  • Optical lens
  • Barlow lens
  • Optical zoom
  • Digital zoom
  • Fixed working distance
  • Image sensor
  • White balance
  • Display resolution
  • Frame rate
  • Pixel size
  • Signal-to-noise ratio
  • Interface
  • Power supply mains adapter
  • Illumination incident light
  • Illumination transmitted light
  • Environmental conditions
  • Dimensions
  • Weight

Product Delivery Scope

  • Digital microscope PCE-LCM 50
  • USB mouse
  • Micro-SD card
  • Protective cover
  • Contrast disc black/white
  • Translucent lens
  • Mains adapter
  • Protective film
  • User manual

Product Usage Instructions

Please read the user manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty. The microscope has several user interfaces. These can be opened by moving the mouse to the left or bottom edge of the screen. Below are the instructions for the key features:

Lighting

The microscope has an incident and a transmitted light function.The illumination can be adjusted separately in 5 brightness levels. To adjust the illumination, press the INC key for incident light and TRA for transmitted light. The keys are located on the microscope table.

  • Click to take a picture. The screen displays a message with the file name. Hint: Dimension lines and drawing elements are not included in the image.
  • Click to start and stop a video recording. After the recording has started, a time indication starts in the upper right corner of the display indicating the recording time.
  • File overview Shows the existing image and video files in a side view. The navigation through the file overview is explained in chapter 6.1.1.
  • Drawing menu In the drawing menu, you will find shapes and operations for measuring the image, explained in chapter 6.1.2, and the calibration menu, explained in chapter 6.1.3.
  • Please refer to the user manual for detailed instructions on using each of these functions.

Safety notes

Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty.

  • The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
  • The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
  • Do not expose the device to shocks or strong vibrations.
  • The case should only be opened by qualified PCE Instruments personnel.
  • Never use the instrument when your hands are wet.
  • You must not make any technical changes to the device.
  • The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
  • The device must only be used with accessories from PCE Instruments or equivalent.
  • Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
  • Do not use the instrument in explosive atmospheres.
  • The measurement range as stated in the specifications must not be exceeded under any circumstances.
  • Non-observance of the safety notes can cause damage to the device and injuries to the user.
  • Do not touch the lenses.
  • When the microscope is not in use, use the dust cover.
  • We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business.

Delivery scope

  • 1 x digital microscope PCE-LCM 50
  • 1 x USB mouse
  • 1 x micro-SD card
  • 1 x protective cover
  • 1 x contrast disc black / white
  • 1 x translucent lens
  • 1 x mains adaptor
  • 1 x protective film
  • 1 x user manual

Specifications

Optical lens 1 … 4 x
Barlow lens 0.3 x
Optical zoom 8.1………… x
Digital zoom 1 … 10 x
Fixed working distance 90.5 mm
Image sensor 1/3″, 3MP
White balance automatically or by pressing a key
Display resolution 1024 x 600 pixels
Frame rate 30 fps
Pixel size 2.75 x 2.75 µm
Signal-to-noise ratio >65 db
Interface USB 2.0
Power supply mains adaptor primary: 100 … 240 V

secondary: 12 V, 1 A

Illumination incident light| ring with 21 x 20 mA LEDs, adjustable in 5 steps
Illumination transmitted light| 7 x 20 mA LEDs, adjustable in 5 steps
Environmental conditions| -5 … 40 °C / 23 … 104 °F, 45 … 85 % RH
Dimensions| 300 x 225 x 270 mm / 11.8 x 8.9 x 10.6 in
Weight| approx. 2.3 kg / 5.1 lbs

Device description

PCE-Instruments-PCE-LCM-50-Digital-Microscope-fig-2

1. 9″ display
2. Micro-SD card slot
3. On/off switch for the display (standby)
4. USB 3.0 interface
5. Focusing wheel
6. Setting the lighting
7. Connection for power supply (on the back)
8. Display on/off switch
9. Illumination for transmitted light microscopy
10. Stage
11. LED ring
12. Mechanically adjustable zoom

Lighting

The microscope has an incident and a transmitted light function. The illumination can be adjusted separately in 5 brightness levels. To adjust the illumination, press the “INC” key for incident light and “TRA” for transmitted light. The keys are located on the microscope table.

Description of user interfaces

The microscope has several user interfaces. These can be opened by moving the mouse to the left or bottom edge of the screen.

Menu screen left

  • Click to take a picture. The screen displays a message with the file name.

Hint

  • Dimension lines and drawing elements are not included in the image.
  • Click to start and stop a video recording. After the recording has started, a time indication starts in the upper right corner of the display indicating the recording time.

File overview

  • Shows the existing image and video files in a side view.
  • The navigation through the file overview is explained in chapter 6.1.1.

Drawing menu

  • In the drawing menu, you will find shapes and operations for measuring the image, explained in chapter 6.1.2, and the calibration menu, explained in chapter 6.1.3.

Settings menu

  • Options for the image settings and other system settings such as date and time settings.
File overview
  • The file overview shows images and videos recorded on the SD card.
  • You can switch to the large view of the images with a double click.

Navigation bar

Back button

  • Exit the file overview or the large view.

Forward / back button

  • Navigate through the file overview and the large view.

Delete button

  • Delete the displayed item.
  • In the file overview, an entry must be selected by a mouse click.
Drawing menu

_ Note: _Some characters are placed to indicate distances or areas and are generated based on the stored calibration. The calibration of the PCE-LCM 50 is explained in chapter 6.1.3.

Point

  • Click to place a point at the current cursor position.

Circle from radius

  • Select the centre point by a click, then move the cursor to the desired distance for the radius.

Circle from 2 points

  • Create 2 reference points that lie on the edge of the created circle.

Circle from 3 points

  • Create 3 reference points. The circle is created so that all 3 reference points are on the circumference.

Distance between two circles

  • The function measures a distance between two circles which can be created by various sub-functions.

Concentric circles

  • Create a circle using the circle-from-radius function. Here you can create one or more circles with the same centre point.

Distance between line and circle

  • Create a circle using the circle-from-radius function. Then select 2 points to create a straight line. The measured distance “LD-X” describes the distance between the straight line and the centre of the circle.

Polygon

  • Create a polygon with any number of reference points. To finish the polygon, press the right mouse button.

Crosshairs

  • With one click, you create a reference point with coordinates.

Rectangle

  • Creates a rectangle from 2 reference points.

Line from several points

  • Creates a line from several reference points.

Arc from 3 points

  • Creates an arc from 3 reference points.

Freehand line

  • Creates a line from cursor movements.

Line

  • Creates a line from 2 reference points.

Perpendicular lines

  • First, a line is created.
  • Subsequently, another reference point is used to create a line that is perpendicular to the first line.

Parallel lines

  • First, a line is created. Then, with another click, you create the first reference point for the parralel line.
  • The start of this is oriented towards the cursor position.
  • With another click, you can finish the line.

Angle measurement

  • First, a line is created.
  • Then create another line from the end point. The smallest angle between the new line and the original line is measured.

Text

  • A text field is created. After this, a virtual keyboard is displayed to enter a text. Finish the entry by clicking on the “Confirm” button.

Sheet export

  • With this function, you can export the automatically determined dimensions of the drawing elements as a CSV file. This file is saved to the SD card with the corresponding time.

Mouse

  • Switch to the mouse to make further settings.

Select and delete

  • Use the option to select a drawing element on the display to delete it.

Delete all

  • Deletes all drawing elements on the screen.

Screenshot

  • This function saves the image with the created points and graphics to the SD card. These images are not listed in the file overview.
Calibration
  • “Add “: Creates a new calibration
  • “Delete”: Deletes the selected calibration
  • “Edit “: Edit the calibration
    • Adjusting the name, length and length unit

Place a dimensioned object under the microscope, for example a ruler. Open the drawing menu, click on “Add” in the lower area. Select 2 points to set a distance on the display. To open the menu again, move the mouse to the left edge of the screen. Click on “Length” and enter the actual length between the two points. To complete the calibration, click on “Done”.

  • Note that a calibration is only valid for a certain focus.
  • If the focus changes, a new calibration is required.

Light settings

  • Automatic exposure
    • Adjusts the exposure if the resulting image is overexposed or underexposed.
  • Reset
    • Resets the light settings.
  • Target brightness
    • Setting for automatic exposure.
  • Exposure
    • Controls the light that comes from the LED ring.
  • White balance
  • Red
  • Green
  • Blue
    • Describes the red/green / blue portion of the image.
    • Adjustable to perform color correction.
  • Colour temperature
    • Adjusts the red, green and blue portions to create a “cold” or “warm” colour impression.
  • Antiflicker
    • Counteracts flickering effects of electric light sources.
  • Contrast
    • Sets the difference in the brightness of the light and dark parts of the image.
  • Saturation
    • Allows you to create a colourful/achromatic presentation.
  • Brightness
    • Adjustment of the light produced by the LED ring.
  • Sharpness
    • Controls the difference of details and how much they differ from each other.
  • Noise suppression
    • Setting to avoid interfering signals in the video transmission.
  • Language
    • Available languages: English / German / French / Chinese / Korean
  • Date settingPCE-Instruments-PCE-LCM-50-Digital-Microscope-fig-52
  • Time settingPCE-Instruments-PCE-LCM-50-Digital-Microscope-fig-53
  • Storage optionPCE-Instruments-PCE-LCM-50-Digital-Microscope-fig-54
    • Selects the storage location for new files and offers the option to format the data media (the included micro-SD card or a USB pen drive).
    • Version

Menu at the bottom

  • Zoom in
    • Enlarges the image by a factor of 0.1, up to a maximum of 10.
  • Zoom out
    • Reduces the image by a factor of 0.1. The image size cannot become smaller than 1.
  • Mirror vertical
    • Mirrors the image on the vertical axis.
  • Mirror horizontal
    • Mirrors the image on the horizontal axis.
  • Quick saturation
    • Corrects the saturation of the settings menu.
  • HDR
    • Function to compensate for shadows or overexposure.
  • Freeze
    • Freezes the image.
  • Grid options
    • Settings to show or hide scale bars / a grid.
  • Line options
    • Compare to saved image
    • Opens the file overview, shows the selected image on the right side of the screen.
  • Quarter camera image
    • Quarter the current view.

Attention: The calibration is not scaled. You must adjust your calibration if you work with dimensions.

Troubleshooting

Error Reason Solution
The field of vision is dirty Your sample is contaminated Clean your sample.
The lenses are contaminated. Clean the lenses.
No clear picture The lenses are contaminated. Clean the lenses.
Illumination does not work when the supply voltage is connected No power
supply Check the mains adaptor.
Lighting defective Get in touch with PCE Instruments.
Dark image Brightness setting is too low Increase the brightness setting.
White balance is inefficient Adjust the white balance manually.

The angle between the display and the microscope

is large

| Adjust the angle.
No image on the screen| No power supply| Check the mains adaptor and      the connection

method.

Screen switch is off| Switch on the display using the display switch.

Contact

If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.

Disposal

For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.

PCE Instruments contact information

Germany

United Kingdom

The Netherlands

Italy

United States of America

Spain

Denmark

  • PCE Instruments Denmark ApS
  • Birk Centerpark 40 7400 Herning Denmark

© PCE Instruments

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

PCE Instruments User Manuals

Related Manuals