Altronix ALTV2416UL3 Series CCTV Power Supplies Instruction Manual
- June 10, 2024
- Altronix
Table of Contents
ALTV2416UL3 Series CCTV Power Supplies
Product Information
The ALTV2416UL3 Series CCTV Power Supplies are designed to provide 24VAC or 28VAC power distributed via sixteen (16) fuse or PTC protected outputs for powering CCTV cameras, heaters, and other video accessories. The models vary in output voltage, total output current (power), number of outputs, PTC or fuse protection, individual output current, and fuse ratings. The product is intended for indoor use only and should be installed in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI and with all local codes and authorities having jurisdiction. The product comes with a terminal identification PD8/PD8CB – Distribution Module for AC output and PD16W/PD16WCB – Distribution Module for AC output.
Product Usage Instructions
- Mount the unit in the desired location using the top two keyholes.
- Connect the AC input voltage to the primary in-line fuse ratings (115VAC 60Hz input current) using proper wiring methods according to the National Electrical Code/NFPA 70/NFPA 72/ANSI and with all local codes and authorities having jurisdiction.
- Use the terminal identification PD8/PD8CB or PD16W/PD16WCB for AC output connection.
- Refer to the ALTV2416UL3 Reference Chart to determine the appropriate model for your system.
- Connect your CCTV cameras, heaters, and other video accessories to the sixteen (16) fuse or PTC protected outputs provided by the product.
- Ensure that the individual output current does not exceed the total output current specified for your model.
- In case of overload or short circuit, the PTC or fuse protection will automatically reset or require a manual reset depending on the model.
Models Include:
- ALTV2416ULX3
- 24VAC @ 7A (170VA) or 28VAC @ 6A (170VA).
- Sixteen (16) Fuse Protected Outputs.
- ALTV2416300UL3
- 24VAC @ 7A (175VA) or 28VAC @ 6.25A (175VA).
- Eight (8) Fuse Protected Outputs.
- ALTV2416300ULM3
- 24VAC @ 12.5A (300VA) or 28VAC @ 10A (280VA).
- Sixteen (16) Fuse Protected Outputs.
- ALTV2416600UL3
- 24VAC @ 25A (600VA)or 28VAC @ 20A (560VA).
- Sixteen (16) Fuse Protected Outputs.
- ALTV2416ULCBX3
- 24VAC @ 7A (170VA) or 28VAC @ 6A (1705VA).
- Sixteen (16) PTC Protected Outputs.
- ALTV2416300ULCB3
- 24VAC @ 12.5A (300VA) or 28VAC @ 10A (280VA).
- Sixteen (16) PTC Protected Outputs.
- ALTV2416300ULCBM3
- 24VAC @ 12.5A (300VA) or 28VAC @ 10A (280VA).
- Sixteen (16) PTC Protected Outputs.
- ALTV2416600ULCB3
- 24VAC @ 25A (600VA) or 28VAC @ 20A (560VA).
- Sixteen (16) PTC Protected Outputs.
Overview
Altronix ALTV2416UL3 Series CCTV Power Supplies provide 24VAC or 28VAC distributed via sixteen (16) fuse or PTC protected outputs for powering CCTV cameras, heaters and other video accessories.
Sixteen (16) Output ALTV2416UL3 Reference Chart:
Specifications
Agency Listings:
- UL Listed for Commercial CCTV Equipment (UL 2044). CUL Listed – CSA Standard C22.2 No.1-98, Audio, Video and Similar Equipment.
- CE European Conformity.
Input:
- 115VAC, 50/60Hz.
Output:
- Sixteen (16) fuse or PTC protected outputs.
- 24VAC or 28VAC output
- Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
- Surge suppression.
Features:
- Unit maintains camera synchronization.
- AC power LED indicator.
Features (cont’d):
- Power ON/OFF switch
- (ALTV2416ULX3, ALTV2416ULXCB3).
- Illuminated power disconnect circuit breaker with manual reset (all other models).
- Ease of installation saves time and eliminates costly labor.
- Spare fuses included (on fuse protected models).
- Factory installed 3-wire line cord.
Enclosure Dimensions (H x W x D):
- ALTV2416300ULM3, ALTV2416300ULCBM3: 8.5” x 7.5” x 3.875” (215.9mm x 191mm x 98.4mm).
- ALTV2416ULX3, ALTV2416ULCBX3,
- ALTV2416300UL3, ALTV2416300ULCB3,
- ALTV2416600UL3 and ALTV2416600ULCB3:
- 13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm).
Installation Instructions
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only.
-
Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 11 – 12). Secure enclosure to earth ground.
-
Set power switch on power distribution board marked [PD] to OFF position for models ALTV2416ULX3 or ALTV2416ULCBX3 (Fig. 1, 2, pg. 4, 5). Set power disconnect circuit breaker to OFF position for all other models (Fig. 3a – 8a, pg. 6 – 10).
-
All units are factory set for 24VAC operation. For 28VAC operation, adjust unit prior to mounting and applying power as follows:
-
Change the wire position so that the wire marked [28V] is connected to the terminal marked [P] and the wire marked [24V] is connected to the terminal marked [S].
Note: ALTV2416ULCBX3 set for 28VAC operation is not Class 2 Rated, not power-limited. -
Plug-in 3-wire line cord (Fig. 1 – 8, pg. 4 – 10). Keep power-limited (PTC protected outputs only) wiring separate from non power-limited wiring. Minimum 0.25” spacing must be provided. Use separate knockouts.
-
Set power switch on power distribution board marked [PD] to ON position for models ALTV2416ULX3 or ALTV2416ULCBX3 (Fig. 1, 2, pg. 4, 5). Set power disconnect circuit breaker to RESET (ON) position for all other models (Fig. 3a – 8a, pg. 6 – 10).
-
Measure output voltage before connecting devices. This helps avoiding potential damage. Terminals marked [1P – 16P] are of the same polarity.
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the output voltage. -
Set power switch on power distribution board marked [PD] to OFF position for models ALTV2416ULX3 or ALTV2416ULCBX3 (Fig. 1, 2, pg. 4, 5). Set power disconnect circuit breaker to OFF position for all other models (Fig. 3a – 8a, pg. 6 – 10).
-
Connect devices to terminals marked [1P – 1N] through [8P – 8N] on PD8 board (Fig. 1 – 4, pg. 4 – 7, Fig. 7 – 8, pg. 9 – 10), or terminals marked [1P – 1N] through [16P – 16N] on PD16W/
PD16WCB board (Fig. 5 – 6, pg. 8), carefully observing polarity. -
Set power switch on power distribution board marked [PD] to ON position for models ALTV2416ULX3 or ALTV2416ULCBX3 (Fig. 1, 2, pg. 4, 5). Set power disconnect circuit breaker to RESET (ON) position for all other models (Fig. 3a – 8a, pg. 6 – 10).
-
Green LED will illuminate when power is present.
-
Upon completion of the wiring, secure enclosure door with screws (supplied). Installation of cam lock is optional.
Caution: Equipment to be installed/serviced by authorized/trained personnel only. Shut branch circuit power before installing/servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes. Use 75˚C or higher rated UL insulated wiring for connecting the unit to the mains. Replace fuses with the same type and rating (refer to Sixteen (16) Output ALTV2416UL3 Reference Chart, pg. 2).
Terminal Identification
PD8/PD8CB – Distribution Module PD16W/PD16WCB – Distribution Module
- Fig. 1 – ALTV2416ULX3
- Fig. 2 – ALTV2416ULCBX3
- Fig. 3 – ALTV2416300UL3
- Fig. 4 – ALTV2416300ULCB3
- Fig. 5 – ALTV2416300ULM3
- Fig. 6 – ALTV2416300ULCBM3
- Fig. 7 – ALTV2416600UL3
- Fig. 8 – ALTV2416600ULCB3
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of impor-tant operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.
Enclosure Dimensions (H x W x D):
- ALTV2416300ULM3
- ALTV2416300ULCBM3
- 8.5” x 7.5” x 3.875” (215.9mm x 191mm x 98.4mm)
Enclosure Dimensions (H x W x D) for:
- ALTV2416ULX3
- ALTV2416ULCBX3
- ALTV2416300UL3
- ALTV2416300ULCB3
- ALTV2416600UL3
- ALTV2416600ULCB3
- 13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn,
New York 11220 USA
phone: 718-567-8181
fax: 718-567-9056
website: www.altronix.com
e-mail: info@altronix.com
Lifetime Warranty IIALTV2416UL3 Series L02U
Rev. 040506 More than just power.TM