HALCYON R738 KWWUD 9.5W Smart Tilt Kit Instruction Manual

June 10, 2024
HALCYON

HALCYON R738 KWWUD 9.5W Smart Tilt Kit Instruction Manual
HALCYON R738 KWWUD 9.5W Smart Tilt Kit

Installation Directions

  1. Switch off mains power supply
  2. Connect Dimmable Driver to mains voltage cable (L, N) Do not connect downlight to driver if driver is live. Inrush current from live driver will cause instant downlight failure. Do not switch secondary side.
  3. Carefully install downlight into Pre-cut 82mm hole.
  4. Turn on mains power and switch on lighting circuit.
    INSTALLATION DIRECTION

Approved Clearances
Note: 0mm required but 25mm always recommended for optimum product lifespan through effective heat dissipation.

Example 1: 0mm Approved Height Clearance. Building element abutting rear, insulation abutting sides of fitting.
CLEARANCES
Example 2: 0mm Approved Side Clearance. Building element abutting side of fitting, insulation abutting and covering fitting.
CLEARANCES

Driver is designed to be covered and abutted with IC / IC-F approved insulation.
LED DRIVER

CLASSIFICATION SHEET / IC

Manufacturer / Supplier Halcyon Lighting Ltd

Product Code R738 KSWUDL, R738 KWWUDL

Product Type LED Recessed Luminaire

Primary Voltage 220-240V-50/60Hz

Secondary Voltage                     260mA 36VDC Constant Current Wattage   9.5W

Ingress Protection Rating IP44

**Classification| IC MARK| ** IC — building insulation that can safely be continuously exposed to 90°C allowed to abut and cover the luminaire.
---|---|---

In the vicinity of the recessed luminaire, use an insulation product that:

a) Maintains its dimensions and structural integrity when exposed to a temperature of 90°C; and
b) Withstands a 30-second needle flame test carried out in accordance with AS/NZS 11.5 with the flame applied to all surfaces of the sample.

Rear of fitting may abut structural members and building elements.
Do not install through or directly into joist, beam, rafter or celling batten.

Side Clearance from heatsink to building element (e.g. timber, joist or batten)
SCB: Omm
Height Clearance from heatsink to building element (e.g. timber, joist or batten) HCB:Omm
Minimum insulation clearance to building element  MIC: Omm

Recessed luminaires and their associated equipment may pose a risk of fire or damage to property if not installed and maintained correctly. Halcyon recommends a clearance of 25mm to building elements for optimum lifespan

Halcyon IC rated luminaires are completely safe to install in sarked timber ceiling linings. Halcyon accepts no responsibility if the timber used is not treated correctly and dries out, crack or warps over time due to the constant low heat from the aforementioned “IC Rated” LED recessed lighting.

This data sheet contains information necessary to ensure compliance with the New Zealand Electrical Code of Practice for Installation and Maintenance of Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001

Cutting of holes prior to receiving goods is entirely at the risk of the installer.