HALCYON LED501 W46 LED Batten Light Instruction Manual
- June 10, 2024
- HALCYON
Table of Contents
HALCYON LED501 W46 LED Batten Light
INSTALLATION INSTRUCTIONS
Product Name: LED IP65 Batten Light
Model #: LED501 W46XPMS, LED502 W46XPMS
Description: 36 Watt LED, Non-dimmable, IP65, 4000K I 6000K 45 Watt LED,
Non-dimmable, IP65, 4000K I 6000K
Rated Voltage: 220-240V~, 50/60Hz
- Switch off power.
- Install the bracket.
- Knock out the hole, fix the waterproof gland.
- Connect the power cords as show on the picture.
- Fasten the clips and drive the 2pcs screws.
- Tighten the waterproof gland.
- Install the fixture on ceiling.
- Switch luminaire on to test luminaire functions correctly and is electrically safe.
Installation note: Do not install on the same circuits as Metal halide,
Fluorescent and other “Low power factor” devices.
When installed on the same circuit it can cause flickering and/or premature
failure of the “high power factor” electronic drivers. The harmonic distortion
from low power factor devices alters the Waveform of the AC supply which can
cause componentry in high power factor electronic drivers to resonate, run
over temperature and fail after prolonged exposure.
REMOTE CONTROL SETTINGS
Remote Control Settings
Button : Keys Introduction
ON/OFF “ON/OFF” key only fully.
AUTO MODE Press “Auto Mode” button, the sensor starts to work and all
settings remain the same before the light gets switched on/off.
RESET Press “Reset” button to reset to factory settings. Default sensor
factory settings: 100% detection area. Hold time: 5 minutes. Daylight
Threshold: Disable.
To adjust brightness 10-100% in on/off mode .To adjust highest brightness
60-100% in sensor mode.
Start Press “Start” to customize scene, users can change detection range,
daylight threshold, hold time, standby dimming level and standby period.
Memory Press “Memory” to save all the settings.
The settings remained as the last time if not get resettled values.
Apply Press “Apply” to deliver the saved setting.
Press “Apply” without “memory “will make all the setting one-time operation.
Settings should be done within 30S, otherwise it exits memory mode.
Detection area Detection area (Press to define detection area 100%/75% /50% /
25%.)
Hold time Hold time (Press to define hold time
5s/30s/1min/3min/5min/10min/20min/30min.)
Stand-by dimming level (Press to define stand-by dimming level
10%/20%/30%/50%.)
Stand-by period (Press to define stand-by period
0s/10s/30s/1min/5min/10min/30min/+00.) Note: “Os” means no standby period;
“+00” means unlimited standby period.
Daylight threshold (Press to define daylight level
2Lux/10Lux/30Lux/50Lux/80Lux /120Lux.Disable.) Example:
Disable means light will be turned on when sensor detects movement, regardless
of the ambient lux. Example: 50 Lux means light will be turned on when sensor
detects movement, if the ambient lux is less than 50.
The button “Test (2s)” is for testing purpose after commissioning. Pressing
this button, the sensor goes to test mode (hold time is only 2s).
APPLICATION
Detection coverage
Typical installation height 2.5-6m.
This figure indicates the maximum distance at the highest mounting height with
100% sensitivity.
Ceiling Mounted
Documents / Resources
|
HALCYON LED501 W46 LED Batten
Light
[pdf] Instruction Manual
LED501 W46 LED Batten Light, LED501 W46, LED Batten Light, Batten Light
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>