Autobotlife A08 Level 2 EV Charger User Manual

June 17, 2024
Autobotlife

Autobotlife-LOGO

Autobotlife A08 Level 2 EV Charger

Specifications

  • Model Number: A08-US48A, A08-US40A
  • Rated Voltage: 208-240V
  • Rated Current: 11.5kW/48A, 9.6kW/40A
  • Standard Compliance: SAE J1772
  • Charging Connector: SAE J1772 Mode 3
  • Electrical Protection: UVP, OVP, RCD, SPD, Ground Fault Protection OCP, OTP, Control Pilot Fault Protection
  • Energy Meter: On-board Device +/- 1% Accuracy
  • User Interface: Digital Screen
  • Multi Cable Entry
  • Connectivity: 2.4G Wi-Fi, Bluetooth
  • Operating Temperature: -40°C to 60°C
  • Operating Humidity: 5% to 95% non-condensing
  • Impact/Ingress Protection Rating: Type 3R
  • Housing Material: PC with Anti-UV Treatment
  • Dimensions (mm): 87190330 (DWH)
  • Net Weight: Approximately 4.8kg

Product Usage Instructions

Unpacking
Make sure that all parts are delivered. Check the packaging for the following parts:

  • AutoBot charger
  • Electric Vehicle AC Charger User Manual
  • Screws (5 x 40 mm)
  • Wall anchors
  • Screw plug
  • RFID cards
  • Installation template

Required Tools
Tools required before installing the charger, gather the following tools:

  • Wire stripper
  • Adjustable wrench
  • Voltmeter or digital multi-meter
  • Level
  • Pencil
  • Electric drill
  • Phillips head screwdriver

Plan The Location
Before installation, check the site for appropriate mounting location and electrical capacity.

WARNING: In areas with frequent thunderstorms, add surge protection at the service panel for all circuits. Ensure all power and ground connections, especially those at the breaker and bus bar, are clean and tight.

CAUTION: Not recommended to be installed in coastal environments with high humidity or high dust.

Mount The Charger
Follow the steps below to mount the charger:

  1. Select a suitable location for mounting the charger.
  2.  Using the installation template, mark the position for mountingholes on the wall.
  3. Drill holes at the marked positions and insert wall anchors.
  4. Align the mounting holes on the charger with the wall anchors.
  5. Securely attach the charger to the wall using screws.

NEMA Plug-in Installation
If you are using a NEMA plug for installation, follow these steps:

  1. Locate the NEMA outlet near the charger installation site.
  2. Connect the NEMA plug to the charger’s AC power input.
  3. Plug the NEMA plug into the NEMA outlet.

Hardwired Installation
If you are using a hardwired installation, follow these steps:

  1. Turn off the electrical power before proceeding.
  2. Remove the knockout on the charger’s AC power input.
  3. Strip the wires on the main power distribution cable.
  4. Connect the wires to the appropriate terminals on the chargerfollowing the provided wiring diagram.
  5. Tighten the terminal screws to secure the connections.
  6. Replace the knockout cover.
  7. Turn on the electrical power.

Operate Your Charger

Power on
To power on the charger:

  1. Ensure that the charger is properly connected to a power source.
  2. Press the power button located on the charger.

Register and Connect Your Charger
To register and connect your charger:

  1. Download and install the AutoBot mobile app from your app store.
  2. Create an account or log in to your existing account.
  3. Follow the app instructions to register your charger.
  4. Connect your charger to your home Wi-Fi network using the app.

Start Charging
To start charging your electric vehicle:

  1. Ensure that your vehicle is properly connected to the charger’s charging cable.
  2. Open the AutoBot mobile app and navigate to the charging section.
  3. Select your vehicle and desired charging settings.
  4. Press the start charging button in the app.

Stop Charging
To stop charging your electric vehicle:

  1. Open the AutoBot mobile app.
  2. Navigate to the charging section.
  3. Press the stop charging button in the app.

The Digital Screen
The digital screen on the charger displays important information about the charging process, such as charging status, charging power, and charging time remaining.

Error and Warning Messages
If you encounter any error or warning messages on the charger’s digital screen, refer to the User Manual or contact technical support for assistance.

FAQ

  1. Q: How can I contact technical support? A: You can contact technical support by emailingsupport@autobotlife.com or calling (+1) 888 559 3888 from Monday through Friday, 9:00 AM to 6:00 PM EST.

  2. Q: What are the overall warnings and cautions for installing the charger?
    A: The overall warnings and cautions include disconnecting electrical power prior to installation, reviewing the User Manual and local building and electrical codes, and having the charger installed by a qualified technician according to safety regulations.

  3. Q: What daily maintenance is required for the charger?
    A: Daily maintenance includes avoiding placing the charger near hot objects or in high-temperature locations, and keeping it away from dangerous substances such as flammable gases and corrosive materials.

GET FREE TECH SUPPORT
support@autobotlife.com (+1) 888 559 3888
(Monday through Friday from 9:00 AM to 6:00 PM EST)

Important Safety Instructions

Overall Warnings & Cautions

WARNING: To avoid fire, injury or death, carefully read and follow the instructions during installation, operation and maintenance.

  • DO NOT put fingers into the electric vehicle connector.
  • DO NOT use this product if the flexible power cord or EV cable is frayed, insulation-broken, or any other signs of damage.
  • DO NOT use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage.
  • DO NOT remove cover or attempt to open the enclosure because of risk of electric shock.
  • DO NOT leave metals such as bolts, gaskets inside the device.
  • WARNING: This device should be supervised when used around children.
  • WARNING: This device must be grounded.
  • WARNING: To avoid a risk of fire or electric shock, do not use this device with an extension cord.
  • WARNING: Switch off the circuit breaker of the electrical outlet before installing this device.

Installation Requirements

WARNING:

  • Disconnect electrical power prior to installing the charger.
  • Be sure to preview the User Manual and ensure local building and electrical codes are reviewed before installing the charger.
  • The charger should be installed by a qualified technician according to the User Manual and local safety regulations.

CAUTION: Use appropriate protection when connecting to the main power distribution cable.

  • Type A, B, C or D breaker with the rating current for table should be installed in the upstream AC distribution box.
  • The device shall be mounted at height between 600 mm and 1500 mm from ground.
  • Install this device on a surface that can support its weight. Failure to do so can result in death, personal injury, or property damage.
  • Please keep the charger in a clean area with low humidity. Not recommended to be installed in coastal environments with high humidity or high dust.
  • Avoid moisture or water in the charger. If there is water or moisture ingress in the charger, it is necessary to immediately power off to avoid immediate danger, and notify the professionals to carry out maintenance before next use.
  • Please use the charger properly. Do not hit or press hard on the enclosure.
  • If it is damaged, please contact a professional technician.
  • Avoid placing the charger near hot objects and at high temperature locations and away from dangerous substances such as flammable gases and corrosive materials.
  • Do not put heavy objects on the charger to avoid danger.

FCC Information

This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to part 15 of the FCC Rules. These limits are designed to providereasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur inaparticular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off andon, theuser is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Information

Caution: Any changes or modifications to this device not explicitly approved by the manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Product Introduction

CAUTION: Avoid placing the charger near hot objects and at high- temperature locations and away from dangerous substances such as flammable gases and corrosive materials.

Basic Interface

Autobotlife-A08-Level-2-EV-Charger-FIG- \(1\)

Dimensions

Autobotlife-A08-Level-2-EV-Charger-FIG- \(2\)

Specifications

TECHNICAL

Model Number| A08-US48A, A08-US40A
Rated Voltage| 208-240V
Rated Current| 11.5kW/48A, 9.6kW/40A
Standard Compliance| SAE J1772
Charging Connector| 25 Feet Tethered SAE J1772
Charging Mode| Mode 3


Electrical Protection

| UVP, OVP, RCD, SPD, Ground Fault Protection OCP, OTP, Control Pilot Fault Protection
Energy Meter| On-board Device +/- 1% Accuracy
FEATURES
User Interface| Digital Screen
Multi Cable Entry| Bottom Side
NETWORK
Connectivity| 2.4G Wi-Fi, Bluetooth
ENVIRONMENT
Operating Temperature| -22°F – 122°F (-30°C – 50°C)
Operating Humidity| Up to RH 95%, non-condensing
Impact/ Ingress Protection Rating| ****

Type 3R

PHYSICAL
Housing Material| PC with Anti-UV Treatment
Dimensions (mm)| 87190330 (DWH)
Net Weight| c. 4.8kg

Unpacking

Components
Make sure that all parts are delivered. Check the packaging for the following parts:

Autobotlife-A08-Level-2-EV-Charger-FIG- \(3\)

Required Tools
Tools required before installing the charger, gather the following tools:

Autobotlife-A08-Level-2-EV-Charger-FIG- \(4\)

Plan The Location

WARNING: In areas with frequent thunderstorms, add surge protection at the service panel for all circuits. Ensure all power and ground connections, especially those at the breaker and bus bar, are clean and tight.

CAUTION: Not recommended to be installed in coastal environments with high humidity or high dust.

Before installation, check the site for appropriate mounting location and electrical capacity.

  1. Choose a mounting location that allows the charging cable to reach the car’s charging port while still providing slack.
  2. The device must be anchored into mounting such as 80mm x 130mm stud or a solid wall.
  3. The device shall be mounted at height between 600 mm and 1500 mm from ground.
  4. Ensure there is Wi-Fi signal available if you want to use the app.
  5. Determine the desired charging amperage and whether the desired circuit rating requires a hardwired circuit. Choose based on the electrical capacity in the panel, the desired speed of charging, and whether the user prefers a hardwired or plug-in installation.

Circuit Rating

|

Max Load

| Estimated Range Per Hour (based on 16kW/100 km)|

Plug- in

|

Hardwire

---|---|---|---|---
60 A| 48 A| Up to 45 miles/72 km| No| Yes
50 A| 40 A| Up to 38 miles/61 km| Yes| Yes
40 A| 32 A| Up to 30 miles/48 km| Yes| Yes
6. Ensure the electrical panel supports a 240V dedicated circuit with a new, dedicated, and non-GFCI two-pole circuit breaker, in accordance with local codes and ordinances. 7. The recommended installation height is between 51 and 59 inches (130 – 150 cm). Note that the minimum installation height must be at least 19 inches (50 cm), measured from the bottom of your charger.

For plug-in installations, the NEMA outlet should be located 43 and 51 inches (110 – 130 cm) from the ground adjacent to the stud where the charging station will be mounted.

Autobotlife-A08-Level-2-EV-Charger-FIG- \(6\)

Mount The Charger

WARNING:

  • This device must be grounded. Disconnect electrical power prior to installing the charger.
  •  Improper connection of the equipment-grounding conductor would result in a risk of electric shock. Check with a qualified electrician or serviceman if you are not sure whether the product is properly grounded. Do not modify the plug provided with the product – if it doesn’t fit the outlet, have a proper outlet installed by a qualified electrician.

CAUTION: Use appropriate protection when connecting to the main power distribution cable.

NEMA Plug-in Installation

If you already have a NEMA outlet, ensure that:

  • It complies with local electrical codes.
  • It has a designated circuit breaker and electrical wiring that are dimensioned appropriately.

When installing a NEMA outlet, be sure the ground pin is facing up as shown in the diagram.

Important Recommendations

  • Ensure you have the correct permits for this electrical installation.
  • Keep in mind that the power supply cable length is about 19 inches (50 cm).
  • Ensure the electrical panel supports a 240V dedicated circuit with a new, dedicated two pole circuit breaker.
  1. Remove the faceplate and the wire cover from the

  2. Hold the included installation template to the wall. Mark the location of the holes. Ensure that the placement of the NEMA outlet and your charger will allow for an adequate connection of the 19” (50 cm) NEMA cable.

  3. Drill 2 holes with a diameter of 12 mm and a depth of 57 mm.

  4. Insert 2 wall anchors into the mounting holes. Then drill one screw into the top-most mounting hole, leaving a 5 mm gap to hang the charger on.

  5. Position the charger to align with the holes and hang it on the protruding screw using the notch on the back of the charger.

  6. Drive the remaining screw into the mounting hole to secure the charger.
    Do not over-tighten the screw.

  7. Attach the screw plug to cover the bottom screw.

  8. Place the wire cover over the exposed wiring.

  9. Insert the four corner screws to secure your charger cover.

  10. Snap the faceplate onto the charger.

Hardwired Installation

  1. Remove the faceplate and the wire cover from the
  2. Hold the included installation template to the wall. Mark the location of the holes. Ensure that the placement of the NEMA outlet and your charger will allow for an adequate connection of the 19” (50 cm) NEMA cable.
  3. Drill 2 holes with a diameter of 12 mm and a depth of 57 mm.
  4. Insert 2 wall anchors into the mounting holes. Then drill one screw into the top-most mounting hole, leaving a 5 mm gap to hang the charger on.
  5. Position the charger to align with the holes and hang it on the protruding screw using the notch on the back of the charger.
  6. Drive the remaining screw into the mounting hole to secure the charger. Do not over-tighten the screw.
  7. Attach the screw plug to cover the bottom screw.
  8. Feed the power supply wires through the bottom port with enough length to easily connect the wires to the terminals.
  9. Use copper conductors with the maximum wire size of 6 AWG (16 mm²).
  10. Strip the wires to 1/2″ (12 mm), insert the wires per the diagram and tighten each connector screw to 2.4 N.m. using a torque screwdriver.
  11. Place the wire cover over the exposed wiring.
  12. Insert the four corner screws to secure your charger cover.
  13. Snap the faceplate onto the charger.

Operate Your Charger

WARNING: This device should be supervised when used around children.

CAUTION:

  • Please use the charger properly. Do not hit or press hard on the enclosure. If the case is damaged, please contact a professional technician.
  • Do not put heavy objects on the charger to avoid danger.

With your charger powered and connected to your EV, you can charge your EV with the provided RFID cards. If you want to fully access your charger functions and control your charger remotely, however, you will need to download the AutoBot EV app.

Power On

Once all electrical connections have been safely made, switch on the power to the circuit from the circuit breaker. If you have installed a NEMA plug-in model, insert the NEMA plug in the receptacle.

The charger LED screen should light up.

Register and Connect Your Charger

  1. Download the AutoBot EV app to your mobile device from the Google Play or Apple App Store.
  2. Open the app, sign in or create an account with your email. You will need to verify your account with a valid email address.
  3. At the top right corner of the home screen, tap +.
  4. Choose the serial number (SN) for your charger. This information can be found on the side of the charger.

Start Charging

CAUTION: Please keep your RFID cards properly to avoid unnecessary loss.

  1. Plug the connector into your EV charging port
  2. If you are using the app, tap “Start Charging” on the app or swipe the RFID card on the RFID reader.
    If you’ve selected the Plug & Charge Mode, charging starts automatically.

Stop Charging

  1. If you are using the app, tap Pause Charging on the app or swipe the RFID card on the RFID reader once more.
  2. Carefully remove the connector from EV.

The Digital Screen

Display Status Description
**** Available * Plug & Charge mode
  • Not connected to EV

***| App mode or RFID Card mode

  • Not connected to EV

| Charging| * Charging in progress

  • Display voltage, current, and charging energy (kWh) in turn

***| Charging ended| Charging ended

*Display charging energy (kWh)

Error and Warning Messages

Error Code Status Description
0001 Off Ground Auto Recover
0002 RCD Abnormal Auto Recover
0004 Over Current Protection Auto Recover
0008 Over Voltage Protection Auto Recover
0016 Under Voltage Protection Auto Recover
0032 Energy Meter Fault Contact Customer Service
0128 Control Pilot Fault Auto Recover
0256 Over Temperature Protection Auto Recover
0512 Ground Fault Auto Recover
1024 Ground Self-Test Auto Recover

Warranty And Maintenance

  • The warranty period for this charger is one year.
  • During the warranty period for any malfunction under normal use according to the User Manual and Service Instructions (to be determined by certified maintenance technicians of sellers), the product shall be repaired free of charge. Except for the following situations, the charger shall be subject to the above warranty terms:
    1. The warranty certificate cannot be provided or the contents of the warranty certificate are modified or inconsistent with the label indication of the repaired product.
    2. Those who are unable to provide valid proof of purchase.
    3. Those who exceed the manufacturer’s specified warranty period.
    4. Those who damage the product due to not following the product service instruction for use, maintenance and storage.
    5. Damage or malfunction caused by external object entering.
    6. Unauthorized repair, disassembly or modification.
    7. Damage caused by force majeure (such as lightning, excessive voltage, earthquake, fire, flood, etc.).
    8. Malfunction and damage caused by other unavoidable external factors. Malfunction and damage caused by improper use of equipment, such as water or other solutions entering into the equipment.

Malfunction and damage caused by the grid power supply and voltage which is not specified for use with the charger equipment.
The above guarantees shall be made solely, and no other express or implied warranties shall be made (including the implied warranties of merchant ability, particular and applicable reasonableness and adaptability, etc.) whether in the contract, civil negligence, or other aspects, the Company shall not be responsible for any special, incidental or consequential damages.

Support
Need technical support? Contact AutoBot customer service (Monday through Friday from 9:00 AM to 6:00 PM EST) :

Tel: (+1) 888 559 3888
Email: support@autobotlife.com
Website: https://autobotlife.com/pages/support

www.autobotlife.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals