ACME XP-550 BSW LEO Hybrid Moving Head User Manual

June 10, 2024
acme

ACME XP-550 BSW LEO Hybrid Moving Head

Product Information

The product is an indoor lighting fixture that comes with effect wheels and a lamp. It has a control panel and is available in both power cord and powercon versions. The fixture produces heat when in use, which can reach up to a surface temperature of 75 degrees Celsius.

Product Usage Instructions

Please read the user manual carefully before using the product.
The following are the usage instructions:

  • Ensure that there is no transportation damage before using the unit.
  • Use safety chain when fixing the unit.
  • Handle the unit by carrying its base instead of head only.
  • The unit must be installed by a qualified operator in a location with adequate ventilation.
  • Always ensure that the unit is firmly fixed to avoid vibration and slipping off during operation.
  • Ensure that the trussing or area of installation can hold at least 10 times the weight without any deformation.
  • Always install a safety cable that can hold at least 12 times the weight of the fixture when installing.
  • Do not allow children to operate the fixture.
  • Keep flammable materials away from the fixture while operating to avoid fire hazard.
  • Make sure the power cord is not crimped or damaged; replace it immediately if damaged.
  • Avoid any flammable liquids, water or metal from entering the unit. Once it happens, cut off the mains power immediately.
  • During initial start-up some smoke or smell may arise. This is  a normal process and does not necessarily mean that the device is defective, and it will decrease gradually within 15 minutes.
  • Before operation, ensure that you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.
  • The yellow/green conductor must be grounded to earth in order to avoid electric shock.
  • Do not operate this product at a lower or higher temperature than the recommended range.
  • Do not touch the housing bare-handed during its operation.

Safety Instructions

warning: Please read the instruction carefully which includes important information about the installation, usage and maintenance.

WARNING: Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual.
Important: Damages caused by the disregard of this user manual are not subject to warranty. The dealer will not accept liability for any resulting defects or problems.

  • Unpack and check carefully to ensure that there is no transportation damage before using the unit.
  • This product is for indoor use only. Use only in a dry location.
  • DO install and operate by qualified operator.
  • DO NOT allow children to operate the fixture.
  • Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only.
  • The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.
  • Be sure that no ventilation slots is blocked, otherwise the unit will be overheated.
  • Before operation, ensure that you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.
  • It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
  • Minimum ambient temperature TA: 0℃. Maximum ambient temperature TA: 40℃. Do not operate this product at a lower or higher temperature.
  • DO NOT connect the device to any dimmer pack.
  • During initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective, and it will decrease gradually within 15 minutes.
  • Keep flammable materials away from the fixture while operating to avoid fire hazard.
  • Make sure the power cord is not crimped or damaged; replace it immediately if damaged.
  • Unit’s surface temperature may reach up to 75℃. DO NOT touch the housing bare-handed during its operation.
  • Avoid any flammable liquids, water or metal from entering the unit. Once it happens, cut off the mains power immediately.
  • DO NOT operate in a dirty or dusty environment. DO clean the fixture regularly.
  • DO NOT touch any wire during operation as there might be a hazard of electric shock.
  • Avoid entanglement of the power cord with other wires.
  • The minimum distance to objects/surface must be more than 12 meters.
  • Disconnect mains power before fuse/lamp replacement or servicing.
  • Replace fuse/lamp only with the same type.
  • In the event of serious operating problem, stop using the unit immediately.
  • Never turn on and off the unit time after time.
  • The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
  • DO NOT open the housing as there are no user serviceable parts inside.
  • DO NOT attempt to operate this unit if it becomes damaged. DO NOT attempt any repairs yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center if needed.
  • Disconnect this product from its power source before servicing.
  • DO use the original packaging if the device is to be transported.
  • Hot lamp explosion hazard. DO NOT open the unit within 15 minutes after switching off.
  • DO replace the bulb once it is damaged, deformed or life-expired.
  • Avoid direct eye exposure to the light source while the product is on.
  • Never touch bulb with bare fingers, as it is very hot after using.
  • DO NOT operate this product if you see damage on the housing, shields, or cables. Have the damaged parts replaced by an authorized technician at once.

Installation:
The fixture should be fixed on the clamp. Always ensure that the unit is firmly fixed to avoid vibration and slipping off during operation. Ensure that the trussing or area of installation must be able to hold 10 times the weight without any deformation. Always install a safety cable that can hold at least 12 times the weight of the fixture when installing. DO install and operate by qualified operator. It must be installed in a place where there is out of the reach of people.

Technical Specifications

The following are the technical specifications of the product:

  • Minimum ambient temperature TA: 0
  • Maximum ambient temperature TA: 40
  • Indoor use only
  • Use only in a dry location
  • Must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces
  • Do not connect the device to any dimmer pack

Control Panel
The control panel is where you can turn on/off the fixture, adjust the brightness, and select different effect wheels.

  • Power Voltage: 100-240V~ 50/60Hz
  • Power Consumption: 755W
  • Light Source: PHILIPS MSD Platinum 25 R
  • Color Temperature: 7800K

Zoom Range

  • Beam Mode: 2°~7°
  • Spot Mode: 5°~34°
  • Wash Mode: 8°~70°

Movement

  • Pan: 540°
  • Tilt: 270°
  • Pan/Tilt Resolution: 16 bit
  • Fixation: Tilt lock
  • Dimmer/Shutter: Smooth dimming from 0-100%; outstanding strobe effect with variable speed
  • Color Wheel: 1 x color wheel with 14 fixed colors plus open, and rainbow effect
  • Gobo Wheel: 1 x static gobo wheel with 18 gobos plus open 1 x rotating gobo wheel with 7 gobos plus open, convenient replacement Control:
  • DMX Channel: 25/18/26/19 channels
  • Control Mode: DMX512, RDM, Art-Net, sACN Firmware upgrade via DMX link or USB disk

Construction:

  • Display: LCD display
  • Battery: backup for user setup without mains connection
  • Data In/Out: 3-pin and 5-pin XLR, RJ45
  • Power In/Out: Power Cord, Power Connector in/out
  • Protection Rating : IP20

Features :

  • Motorized focus
  • Linear CMY color mixing + Variable CTO
  • 1 x animation wheel with outstanding water and flame effect, the wheel can be replaced 2x prisms: 8-facets prism+6-facets linear prism, rotatable in both directions and overlayable Independent
  • frost effect 2x fixed clamps for 50mm truss

Dimension/Weight:

  • 402x308x725mm, 30.5kgs
  • 15.8″x12.1″x28.5″in, 67.2lbs

Photometric Diagram

ACME XP-550-BSW-LEO-Hybrid-Moving-Head-fig-2

Control Panel

Power Cord Version:ACME XP-550-BSW-LEO-Hybrid-Moving-Head-
fig-3 **Powercon Version:ACME XP-550-BSW-LEO-
Hybrid-Moving-Head-fig-4**

  1. Display: To show the various menus and the selected function
  2. Button:**
    MENU| To enter into move backward or leave the menu
    ---|---
     
    UP| To go backward to move up in the menu
     
    DOWN| To go forward to move down in the menu
    ENTER**| To perform the desired functions
  3. BATTERY DISPLAY
  4. ETHERNET: Transfers fixture’s information to a main controller
  5. DMX IN: For DMX512 link, use 3-pin/5-pin XLR cable to link the unit and DMX controller
  6. DMX OUT: For DMX512 link, use 3-pin/5-pin XLR cable to link the next units
  7. POWER IN: To connect to supply power
  8. FUSE(T 15A): Protects the unit from over-voltage or short circuit
  9. FIRMWARE UPGRADE: Used to upgrade the firmware of the fixture
  10. POWER SWITCH: Turns on/off the power
  11. POWER OUT(Powercon Version): To connect to the next fixture

Effect Wheels and Lamp

Effect Wheels

ACME XP-550-BSW-LEO-Hybrid-Moving-Head-fig-5

DANGER: Install the rotating gobos with the device switched off only. Unplug from mains before changing the rotating gobos!
CAUTION: Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be opened

R-Gobos Part Number
① Gobo1 3011001165
② Gobo2 3011001053
③ Gobo3 3011001167
④ Gobo4 3011001170
⑤ Gobo5 3011001168
⑥ Gobo6 3011001166
⑦ Gobo7 3011001169

Light Source

PHILIPS MSD Platinum 25 R

  • Because of its high internal pressure, there might be a risk that the Discharge lamp would explode during operation. The lamp emits intense UV radiation which is harmful to the eyes and skin. The high luminance of the arc can cause severe damage to the retina if you take a close look at the lamp.
  • To protect the lamp, always turn off the lamp first (via control panel or DMX controller) and let the unit run at least five minutes to cool down before switching off the mains supply. Never handle the lamp or luminary when it is hot.
  • Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation.
  • The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
  • When lighting up, the lamp operates at high pressure and there is a slight risk of arc tube rupture. The risk increases with age, temperature and improper handling of the lamp. Do not use the lamp longer than its lifespan.
  • Make sure the lamp is located in the center of the reflector for the best projection.

Change The Lamp

Attention: The entire light path and lens of the luminaire must be thoroughly cleaned before changing the bulb.
Do not use this lamp more than 1500 hours, using the lamp any longer than its set life could seriously damage your unit. Periodically checking the lamp running time, when the lamp reaches the 1500 hour mark, or close to it, we strongly suggest you switch the lamp out. Clear the lamp time after you have replaced the lamp.

To replace the lamp:

  1. Ensure that the fixture is detached from power and has cooled down completely. It is a good idea to allow the fixture to run for 10 minutes after the lamp has been turned off, so that the cooling fans have time to works.

  2. Loosen the screws on the head of the fixture and open the fixture head covers.ACME XP-550-BSW-LEO-Hybrid-Moving-Head-fig-7

  3. Unplug the leads of the lamp and lift the lamp out of its recess, disconnect the lamp and connect a new lamp that must be the same type with the old one. And then place the new lamp into the lamp recess.ACME XP-550-BSW-LEO-Hybrid-Moving-Head-fig-8Finally reinstall the head cover, fastening it securely before reapplying power.
    Warning: The installing direction of lamp:

Lamp Replacement Warning

  • When the lamp reaches 1200 hours of usage, the display will flash the message “Replace The Lamp Soon” for up to 5 minutes. During this period, the fixture will still work normally.
  • When the lamp reaches 1500 hours of usage, the display will flash the message “Replace The Lamp Now” for up to 10 minutes. After 10 minutes, the fixture will return to normal operation.
  • When the lamp is continuously used overtime, the display will flash the message “Lamp Timeout Use, Replace The Lamp Now” for up to 10 minutes. After 10 minutes, the fixture will return to normal operation.

Attention: Damages caused by the failure to replace the bulb in time are not subject to warranty.

How To Set The Unit

Main Function
Turn on the unit, press the MENU button into menu mode, and press the UP/DOWN button until the required function is shown on the monitor. Select the function by pressing the ENTER button. Use the UP/DOWN button to choose the submenu, press the ENTER button to store and automatically return to the last menu. Press the MENU button or let the unit idle 30 seconds to exit menu mode.
The main functions are shown below:ACME XP-550-BSW-LEO-Hybrid-Moving-Head-
fig-10 ACME XP-550-BSW-LEO-Hybrid-Moving-Head-
fig-11

DMX Settings
To select DMX Settings, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address, DMX Channel Mode, No DMX Status, Connect Option, Network, Art-Net, sACN Settings, Artnet to DMX or View DMX Value.

DMX Address
To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the address from 001 to 488/495/487/494, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

DMX Channel Mode
To select DMX Channel Mode, press the ENTER button to confirm. Use the UP/DOWN button to select Mode1 (25), Mode2 (18), II Mode1 (26) or II Mode2 (19), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

No DMX Status
To select No DMX Status, press the ENTER button to confirm. Use the UP/DOWN button to select BlackOut(fixture blacks out if DMX signal stops), Hold(fixture continues to obey the last command it received Via DMX if DMX signal stops) or Manual(the fixture will automatically read the DMX value in the “Manual Test” menu for operation after selecting this mode), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Connect Option
To select Connect Option, press the ENTER button to confirm. Use the UP/DOWN button to select Auto, DMX, Art-Net or sACN, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Network
To select Network, press the ENTER button to confirm. Use the UP/DOWN button to select IP Address or Subnet Mask, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Art-Net
To select Art-Net, press the ENTER button to confirm. Use the UP/DOWN button to select Net, Subnet or Universe, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

sACN Settings
To select sACN Settings, press the ENTER button to confirm. Use the UP/DOWN button to select sACN Universe or sACN Priority, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Artnet to DMX
To select Artnet to DMX, press the ENTER button to confirm. Use the UP/DOWN button to select No or Yes, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

View DMX Value
To select View DMX Value, press the ENTER button to confirm. Use the UP/DOWN button to view the DMX channel value. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Fixture Settings
To select Fixture Settings, press the ENTER button to confirm, use the UP/DOWN button to select Pan Invert, Tilt Invert, P/T Feedback, Pan/Tilt Speed, Focus Compensate or Dimmer Curve.

Pan Invert
To select Pan Invert, press the ENTER button to confirm. Use the UP/DOWN button to select No (normal) or Yes (pan invert), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Tilt Invert
To select Tilt Invert, press the ENTER button to confirm. Use the UP/DOWN button to select No (normal) or Yes (tilt invert), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

P/T Feedback
To select P/T Feedback, press the ENTER button to confirm. Use the UP/DOWN button to select No (Pan or tilt’s position will not feedback while out of step) or Yes (Feedback while pan/tilt out of step), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Pan/Tilt Speed
To select Pan/Tilt Speed, press the ENTER button to confirm. Use the UP/DOWN button to select Slow or Fast, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Focus Compensate
To select Focus Compensate, press the ENTER button to confirm. Use the UP/DOWN button to select Disable, Near, Medium or Far, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Dimmer Curve
To select Dimmer Curve, press the ENTER button to confirm. Use the DOWN/UP button to select Linear, Square Law, Inv SQ Law or S Curve, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Dimmer Modes

ACME XP-550-BSW-LEO-Hybrid-Moving-Head-
fig-12

  • Optically Linear: The increase in light intensity appears to be linear as DMX value is increased. Square Law: Light intensity control is finer at low levels and coarser at high levels.
  • Inverse Square Law: Light intensity control is coarser at low levels and finger at high levels.
  • S-Curve: Light intensity control is finger at low levels and high levels and coarser at medium levels.

Lamp Settings
To select Lamp Settings, press the ENTER button to confirm, use the UP/DOWN button to select Lamp On/Off, Lamp On With Power, Lamp On via DMX or Lamp Off via DMX.

Lamp On/Off
To select Lamp On/Off, press the ENTER button to confirm. Use the UP/DOWN button to select Off(lamp off) or On(lamp on), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Lamp On With Power
To select Lamp On With Power, press the ENTER button to confirm. Use the UP/DOWN button to select Off(Lamp off while power on) or On(Lamp on while power on), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Lamp On via DMX
To select Lamp On via DMX, press the ENTER button to confirm. Use the UP/DOWN button to select Off or On, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Lamp Off via DMX
To select Lamp Off via DMX, press the ENTER button to confirm. Use the UP/DOWN button to select Off or On, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Display Settings
To select Display Settings, press the ENTER button to confirm, use the UP/DOWN button to select Display Invert, Backlight Intensity, Temperature Unit or Language.

Display Invert
Select Display Invert, press the ENTER button to confirm. Use the UP/DOWN button to select No (normal display) or Yes (invert display), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Backlight Intensity
Select Backlight Intensity, press the ENTER button to confirm. Use the UP/DOWN button to adjust backlight intensity from 1 (dark) to 10 (bright), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Temperature Unit
Select Temperature Unit, press the ENTER button to confirm. Use the UP/DOWN button to select ℃ or ℉, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Language
Select Language, press the ENTER button to confirm. Use the UP/DOWN button to select English or Chinese, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Fixture Test
To select Fixture Test, press the ENTER button to confirm, use the UP/DOWN button to select Auto Test or Manual Test

Auto Test
Select Auto Test, press the ENTER button to confirm, the unit will run built- in programs to automatically test pan, tilt, color, gobo, gobo rotation, animation, prism, prism rotation, strobe, frost, focus, zoom, etc. Press the MENU button back to the last menu or exit menu mode after auto test.

Manual Test
Select Manual Test, press the ENTER button to confirm, the present channel will show on the display, use the UP/DOWN button to select channel, press the ENTER button to confirm, then use the UP/DOWN button to adjust the value, press the ENTER button to store, the fixture will run as the channel value indicates. Press the MENU button back to the last menu or exit menu mode idling 30 seconds.
(The fixture will return to the previous DMX state after exiting Manual Test menu and the Manual Test parameters will be automatically saved after power off and restart.)

Fixture Information
To select Fixture Information, press the ENTER button to confirm, use the UP/DOWN button to select Fixture Use Hour, Lamp Use Time, Lamp Time Reset, Lamp State, Fan State, USB Upgrade File, Firmware Version, RDM UID or Error Logs.

Fixture Use Hour
Select Fixture Use Hour, press the ENTER button to confirm, fixture use hour will show on the display, press the MENU button to exit.

Lamp Use Time
Select Lamp Use Time, press the ENTER button to confirm, lamp use time will show on the display, press the MENU button to exit.

Lamp Time Reset
Select Lamp Time Reset, press the ENTER button to confirm, use the UP/DOWN button to set the password 050 to reset lamp use time, press the MENU button to exit.

Lamp State
Select Lamp State, press the ENTER button to confirm, lamp state will show on the display, press the MENU button to exit.

Fan State
Select Fan State, press the ENTER button to confirm, fan state will show on the display, press the MENU button to exit.

USB Upgrade File
Select USB Upgrade File, press the ENTER button to confirm, USB upgrade file will show on the display, press the MENU button back to exit.

Firmware Version
Select Firmware Version, press the ENTER button to confirm, firmware version will show on the display, press the MENU button back to exit.

RDM UID
Select RDM UID, press the ENTER button to confirm, RDM UID will show on the display, press the MENU button back to exit.

Error Logs
Select Error Logs, press the ENTER button to confirm. Use the UP/DOWN button to select Fixture Errors or Reset Error Log, press the ENTER button to store. Select Reset Error Log, press the ENTER button to confirm. Use the UP/DOWN button to select No or Yes, press the ENTER button to store. Select Yes, press the ENTER button to confirm. Use the UP/DOWN button to set the password 050, press the ENTER button to reset error log. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Reset Functions

To select Reset Functions, press the ENTER button to confirm, use the UP/DOWN button to select Pan/Tilt Reset, Effect Reset or All Reset.
Pan/Tilt Reset
Select Pan/Tilt Reset, press the ENTER button to confirm, use the UP/DOWN button to select No(normal) or Yes (the unit will run built-in program to reset pan and tilt to their home positions), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Effect Reset
Select Effect Reset, press the ENTER button to confirm, use the UP/DOWN button to select No(normal) or Yes (the unit will run built-in program to reset effect to their home positions), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
All Reset
Select All Reset, press the ENTER button to confirm, use the UP/DOWN button to select No(normal) or Yes (the unit will run built-in program to reset all motors to their home positions), press ENTER button to store. Press the MENU button to exit.

Special Functions

Factory Restore
Select Factory Restore, press the ENTER button to confirm, use the UP/DOWN button to select No(normal) or Yes (the fixture will reset to factory settings), press ENTER button to store. Press the MENU button to exit.

RDM FUNCTIONS

  • Select the MANUFACTURER menu to display the manufacturer of the fixture.
  • Select the SOFTWARE VERSION menu and the program version number of the fixture will be displayed.
  • Select the DMX START ADDRESS menu to change the DMX 512 address (001-512).
  • Select the DEVICE MODEL DESCRIPTION menu to display the model of the fixture.
  • Select the DEVICE LABEL menu to change the model of the fixture.
  • Select the DMX PERSONALITY menu to set the channel mode of the fixture (25/18/26/19 channel). Select the DMX PERSONALITY DESCRIPTION menu to display the current channel mode of the fixture.
  • Select the DEVICE HOURS menu to display the running time of the fixture.
  • Select the LAMP HOURS menu to display the running time of the lamp.
  • Select the LAMP STATE menu to turn on/off the lamp.
  • Select the PAN INVERT menu and the fixture will run the pan invert mode.
  • Select the TILT INVERT menu and the fixture will run the tilt invert mode.
  • Select the RESET DEVICE menu, the WARM RESET/COLD RESET option will be displayed. When WARM RESET is selected, the fixture will start a warm reset, and exit when COLD RESET is selected.

Home Position Adjustment

Press the MENU button into menu mode, then press the ENTER button for about 3 seconds into offset mode to adjust the home position. Select the function by pressing the ENTER button. Use the UP/DOWN button to choose the submenu, press the ENTER button to store and automatically return to the last menu. Press MENU button to exit.ACME XP-550-BSW-LEO-Hybrid-Moving-Head-
fig-13

Pan
Enter offset mode, Select Pan, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Tilt
Enter offset mode, Select Tilt, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Strobe
Enter offset mode, Select Strobe, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from 0 to 255, press the ENTER button to store. Press the MENU button to exit.

Cyan
Enter offset mode, Select Cyan, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Magenta
Enter offset mode, Select Magenta, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Yellow
Enter offset mode, Select Yellow, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Color
Enter offset mode, Select Color, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Rotating Gobo
Enter offset mode, Select Rotating Gobo, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

R-Gobo
Enter offset mode, Select R-Gobo, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Static Gobo
Enter offset mode, Select Static Gobo, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Animation
Enter offset mode, Select Animation, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Soften
Enter offset mode, Select Soften, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from 0 to 255, press the ENTER button to store. Press the MENU button to exit.

Prism 1
Enter offset mode, Select Prism 1, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

R-Prism 1
Enter offset mode, Select R-Prism 1, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Prism 2
Enter offset mode, Select Prism 2, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

R-Prism 2
Enter offset mode, Select R-Prism 2, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Frost
Enter offset mode, Select Frost, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from 0 to 255, press the ENTER button to store. Press the MENU button to exit.

Focus
Enter offset mode, Select Focus, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Zoom
Enter offset mode, Select Zoom, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store. Press the MENU button to exit.

Control By Universal DMX Controller

DMX512 ConnectionACME XP-550-BSW-LEO-Hybrid-Moving-Head-
fig-14

  1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
  2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the input of the next unit. The cable can only be used in series and cannot be connected in parallel. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system.
  3. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected.
  4. Each lighting unit needs to have a DMX address to receive the data by the controller. The address number is between 1-512.
  5. The end of the DMX 512 system should be terminated to reduce signal errors.
  6. 3 pin XLR connectors are more popular than 5 pins XLR.
  7. 3 pin XLR : Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
  8. 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used.

Address Setting

If you use a universal DMX controller to control the units, you have to set DMX address from 1 to 512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select DMX Settings, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address, press the ENTER button to confirm, the present address will blink in the display, use the UP/DOWN button to adjust the address from 001 to 512, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.

Please refer to the following diagram to address your DMX512 channel for the first 4 units.

Channel mode| Unit 1

Address

| Unit 2

Address

| Unit 3

Address

| Unit 4

Address

---|---|---|---|---
25 channels| 1| 26| 51| 76
18 channels| 1| 19| 37| 55
26 channels| 1| 27| 53| 79
19 channels| 1| 20| 39| 58

DMX512 Configuration

Please control the fixture by referring to the configurations below

Attentions

  1. The unit will maintain the last condition until reset if you cut-off the DMX signal.
  2. For the channel Function, keep the value for about 3 seconds, then the corresponding function will take into effect. 25 Channels (Mode 1):
CHANNEL VALUE FUNCTION
1 ****

000-255

| CYAN

0%”100%

2| ****

000-255

| MAGENTA

0%”100%

3| ****

000-255

| YELLOW

0%”100%

4| | CTO
| 000-255| 6000K”3200K
---|---|---










5

| ****

000-007

008-011

012-015

016-019

020-023

024-027

028-031

032-035

036-039

040-043

044-047

048-051

052-055

056-059

060-063

064-127

128-189

190-193

194-255

| COLOR

Open Color 1

Color 2

Color 3

Color 4

Color 5

Color 6

Color 7

Color 8

Color 9

Color 10

Color 11

Color 12

Color 13

Color 14 Index

Clockwise rotation, fast to slow Stop

Counter-Clockwise rotation, slow to fast




6

| ****

000-003

004-103

104-107

108-207

208-212

213-251

252-255

| STROBE

Close

Strobe from slow to fast Open

Pulsation from slow to fast Open

Random Strobe

Open

7| ****

000-255

| DIMMER

0%”100%

8| 000-255| DIMMER FINE







9

| ****

000-003

004-007

008-011

012-015

016-018

019-022

023-026

027-030

031-034

035-037

038-041

042-045

| STATIC GOBO

Open Gobo 1

Gobo 2

Gobo 3

Gobo 4

Gobo 5

Gobo 6

Gobo 7

Gobo 8

Gobo 9

Gobo 10

Gobo 11

| 046-049| Gobo 12
---|---|---
050-053| Gobo 13
054-056| Gobo 14
057-060| Gobo 15
061-064| Gobo 16
065-068| Gobo 17
069-071| Gobo 18
072-113| Clockwise rotation, fast to slow
114-117| Stop
118-159| Counter-Clockwise rotation, slow to fast
160-165| Gobo1 shaking, slow to fast
166-170| Gobo2 shaking, slow to fast
171-175| Gobo3 shaking, slow to fast
176-181| Gobo4 shaking, slow to fast
182-186| Gobo5 shaking, slow to fast
187-191| Gobo6 shaking, slow to fast
192-197| Gobo7 shaking, slow to fast
198-202| Gobo8 shaking, slow to fast
203-207| Gobo9 shaking, slow to fast
208-214| Gobo10 shaking, slow to fast
215-218| Gobo11 shaking, slow to fast
219-223| Gobo12 shaking, slow to fast
224-229| Gobo13 shaking, slow to fast
230-234| Gobo14 shaking, slow to fast
235-239| Gobo15 shaking, slow to fast
240-245| Gobo16 shaking, slow to fast
246-250| Gobo17 shaking, slow to fast
251-255| Gobo18 shaking, slow to fast
| | ANIMATION
| 000-007| Null
10| 008-129| Clockwise rotation, fast to slow
| 130-133| Stop
| 134-255| Counter-Clockwise rotation, slow to fast
| | ROATING GOBO
| 000-007| Open
| 008-015| Gobo 1
| 016-023| Gobo 2
| 024-031| Gobo 3
| 032-039| Gobo 4
11| 040-047

048-055

| Gobo 5

Gobo 6

| 056-063| Gobo 7
| 064-093| Clockwise rotation, fast to slow
| 094-098| Stop
| 099-129| Counter-Clockwise rotation, slow to fast
| 130-147| Gobo1 shaking, slow to fast
| 148-165| Gobo2 shaking, slow to fast
| 166-183

184-201

202-219

220-237

238-255

| Gobo3 shaking, slow to fast Gobo4 shaking, slow to fast Gobo5 shaking, slow to fast Gobo6 shaking, slow to fast Gobo7 shaking, slow to fast
---|---|---



12

| ****

000-127

128-189

190-193

194-255

| GOBO ROTATION

Index

Counter-Clockwise rotation, fast to slow Stop

Clockwise rotation, slow to fast

13| 000-255| FINE GOBO ROTATION



14

| ****

000-010

011-132

133-223

224-255

| PRISM

Close

Prism1(6-facets linear prism) Prism2(8-facets prism)

Prism1 and Prism2 Mixing Effect



15

| ****

000-127

128-189

190-193

194-255

| PRISM ROTATION

Index

Counter-Clockwise rotation, fast to slow Stop

Clockwise rotation, slow to fast


16

| ****

000-007

008-255

| FROST

Close Open

17| ****

000-255

| ZOOM

2°”70°

18| ****

000-255

| FOCUS

0%”100%

19| 000-255| FOCUS FINE
20| ****

000-255

| PAN

0%”100%

21| 000-255| PAN FINE
22| ****

000-255

| TILT

0%”100%

23| 000-255| TILT FINE
24| ****

000-255

| PAN/TILT SPEED

Fast to slow



25

| ****

000-129

130-139

140-149

150-159

160-169

| SPECIAL FUNCTION

No Function Lamp On Reset XY Reset Effect

Soft Filter Disable

| 170-179

180-199

200-209

210-229

230-239

240-255

| Soft Filter Enable No Function Reset All

No Function Lamp Off

No Function

---|---|---
| |

18 Channels (Mode 2)

CHANNEL VALUE FUNCTION
1 ****

000-255

| PAN

0%”100%

2| 000-255| PAN FINE
3| ****

000-255

| TILT

0%”100%

4| 000-255| TILT FINE
5| ****

000-255

| PAN/TILT SPEED

Fast to slow

6| ****

000-255

| CYAN

0%”100%

7| ****

000-255

| MAGENTA

0%”100%

8| ****

000-255

| YELLOW

0%”100%

9| ****

000-255

| CTO

6000k”3200k








10

| ****

000-007

008-011

012-015

016-019

020-023

024-027

028-031

032-035

036-039

040-043

044-047

048-051

052-055

056-059

060-063

| COLOR

Open Color 1

Color 2

Color 3

Color 4

Color 5

Color 6

Color 7

Color 8

Color 9

Color 10

Color 11

Color 12

Color 13

Color 14

| 064-127

128-189

190-193

194-255

| Index

Clockwise rotation, fast to slow Stop

Counter-Clockwise rotation, slow to fast

---|---|---




11

| ****

000-003

004-103

104-107

108-207

208-212

213-251

252-255

| STROBE

Close

Strobe from slow to fast Open

Pulsation from slow to fast Open

Random Strobe

Open

12| ****

000-255

| DIMMER

0%”100%

13| 000-255| DIMMER FINE


14

| ****

000-007

008-255

| FROST

Close Open

15| ****

000-255

| ZOOM

2°”70°

16| ****

000-255

| FOCUS

0%”100%

17| 000-255| FOCUS FINE






18

| ****

000-129

130-139

140-149

150-159

160-169

170-179

180-199

200-209

210-229

230-239

240-255

| SPECIAL FUNCTION

No Function Lamp On Reset XY Reset Effect

Soft Filter Disable Soft Filter Enable No Function Reset All

No Function Lamp Off

No Function

| |

26 Channels (II Mode 1)

CHANNEL VALUE FUNCTION
1 ****

000-255

| CYAN

0%”100%

2| | MAGENTA
| 000-255| 0%”100%
---|---|---
3| ****

000-255

| YELLOW

0%”100%

4| ****

000-255

| CTO

6000K”3200K










5

| ****

000-007

008-011

012-015

016-019

020-023

024-027

028-031

032-035

036-039

040-043

044-047

048-051

052-055

056-059

060-063

064-127

128-189

190-193

194-255

| COLOR

Open Color 1

Color 2

Color 3

Color 4

Color 5

Color 6

Color 7

Color 8

Color 9

Color 10

Color 11

Color 12

Color 13

Color 14 Color Index

Clockwise Rotation, Fast to Slow Stop

Counter-Clockwise Rotation, Slow to Fast




6

| ****

000-003

004-103

104-107

108-207

208-212

213-251

252-255

| STROBE

Close

Strobe from Slow to Fast Open

Pulsation from Slow to Fast Open

Random Strobe

Open

7| ****

000-255

| DIMMER

0%”100%

8| 000-255| DIMMER FINE





9

| ****

000-007

008-011

012-015

016-019

020-023

024-027

028-031

032-035

| STATIC GOBO

Open Gobo 1

Gobo 2

Gobo 3

Gobo 4

Gobo 5

Gobo 6

Gobo 7

| 036-039| Gobo 8
---|---|---
040-043| Gobo 9
044-047| Gobo 10
048-051| Gobo 11
052-055| Gobo 12
056-059| Gobo 13
060-063| Gobo 14
064-067| Gobo 15
068-071| Gobo 16
072-113| Clockwise Rotation, Fast to Slow
114-117| Stop
118-159| Counter-Clockwise Rotation, Slow to Fast
160-165| Gobo1 Shaking, Slow to Fast
166-171| Gobo2 Shaking, Slow to Fast
172-177| Gobo3 Shaking, Slow to Fast
178-183| Gobo4 Shaking, Slow to Fast
184-189| Gobo5 Shaking, Slow to Fast
190-195| Gobo6 Shaking, Slow to Fast
196-201| Gobo7 Shaking, Slow to Fast
202-207| Gobo8 Shaking, Slow to Fast
208-213| Gobo9 Shaking, Slow to Fast
214-219| Gobo10 Shaking, Slow to Fast
220-225| Gobo11 Shaking, Slow to Fast
226-231| Gobo12 Shaking, Slow to Fast
232-237| Gobo13 Shaking, Slow to Fast
238-243| Gobo14 Shaking, Slow to Fast
244-249| Gobo15 Shaking, Slow to Fast
250-255| Gobo16 Shaking, Slow to Fast
| | ANIMATION
| 000-007| Null
10| 008-129| Clockwise Rotation, Fast to Slow
| 130-133| Stop
| 134-255| Counter-Clockwise Rotation, Slow to Fast
| | ROATING GOBO
| 000-007| Open
| 008-015| Gobo 1
| 016-023| Gobo 2
| 024-031| Gobo 3
| 032-039| Gobo 4
11| 040-047

048-055

| Gobo 5

Gobo 6

| 056-063| Gobo 7
| 064-093| Clockwise Rotation, Fast to Slow
| 094-098| Stop
| 099-129| Counter-Clockwise Rotation, Slow to Fast
| 130-147| Gobo1 Shaking, Slow to Fast
| 148-165| Gobo2 Shaking, Slow to Fast
| 166-183

184-201

202-219

220-237

238-255

| Gobo3 Shaking, Slow to Fast Gobo4 Shaking, Slow to Fast Gobo5 Shaking, Slow to Fast Gobo6 Shaking, Slow to Fast Gobo7 Shaking, Slow to Fast
---|---|---



12

| ****

000-127

128-189

190-193

194-255

| GOBO ROTATION

Gobo Index

Counter-Clockwise Rotation, Fast to Slow Stop

Clockwise Rotation, Slow to Fast

13| 000-255| FINE GOBO ROTATION



14

| ****

000-010

011-132

133-223

224-255

| PRISM

Close

Prism1(6-facets linear prism) Prism2(8-facets prism)

Prism1 and Prism2 Mixing Effect



15

| ****

000-127

128-189

190-193

194-255

| PRISM ROTATION

Prism Index

Counter-Clockwise Rotation, Fast to Slow Stop

Clockwise Rotation, Slow to Fast


16

| ****

000-007

008-255

| FROST

Close Open

17| ****

000-255

| ZOOM

2°”70°

18| ****

000-255

| FOCUS

0%”100%

19| 000-255| FOCUS FINE
20| ****

000-255

| PAN

0%”100%

21| 000-255| PAN FINE
22| ****

000-255

| TILT

0%”100%

23| 000-255| TILT FINE
24| ****

000-255

| PAN/TILT SPEED

Fast to slow


25

| ****

000-007

008-255

| SOFT FILTER

Close Open


26

| ****

000-129

130-139

| SPECIAL FUNCTION

No Function Lamp On

| 140-149

150-159

160-169

170-179

180-199

200-209

210-229

230-239

240-255

| Reset XY Reset Effect No Function No Function No Function Reset All

No Function Lamp Off

No Function

---|---|---
| |

19 Channels (II Mode 2)

CHANNEL VALUE FUNCTION
1 ****

000-255

| PAN

0%”100%

2| 000-255| PAN FINE
3| ****

000-255

| TILT

0%”100%

4| 000-255| TILT FINE
5| ****

000-255

| PAN/TILT SPEED

Fast to slow

6| ****

000-255

| CYAN

0%”100%

7| ****

000-255

| MAGENTA

0%”100%

8| ****

000-255

| YELLOW

0%”100%

9| ****

000-255

| CTO

6000K”3200K






10

| ****

000-007

008-011

012-015

016-019

020-023

024-027

028-031

032-035

036-039

040-043

| COLOR

Open Color 1

Color 2

Color 3

Color 4

Color 5

Color 6

Color 7

Color 8

Color 9

| 044-047

048-051

052-055

056-059

060-063

064-127

128-189

190-193

194-255

| Color 10

Color 11

Color 12

Color 13

Color 14 Color Index

Clockwise Rotation, Fast to Slow Stop

Counter-Clockwise Rotation, Slow to Fast

---|---|---





11

| ****

000-003

004-103

104-107

108-207

208-212

213-251

252-255

| STROBE

Close

Strobe from Slow to Fast Open

Pulsation from Slow to Fast Open

Random Strobe

Open

12| ****

000-255

| DIMMER

0%”100%

13| 000-255| DIMMER FINE


14

| ****

000-007

008-255

| FROST

Close Open

15| ****

000-255

| ZOOM

2°”70°

16| ****

000-255

| FOCUS

0%”100%

17| 000-255| FOCUS FINE


18

| ****

000-007

008-255

| SOFT FILTER

Close Open






19

| ****

000-129

130-139

140-149

150-159

160-169

170-179

180-199

200-209

210-229

| SPECIAL FUNCTION

No Function Lamp On Reset XY Reset Effect No Function No Function No Function Reset All

No Function

230-239

240-255

| Lamp Off No Function
---|---

Error Information

Error codes are shown continuously in the display when the fixture fails and they will not disappear until the fixture is repaired.

  1. CPU-B/C/D/E Error
    • Check whether the 485 (DATA) leads on the PCB board are installed in place or disconnected. Check whether the related 485 (DATA) signal circuit on the PCB board is damaged.
  2. Pan Reset Error
    • Check whether the position of the pan where the magnet is installed falls off or is damaged. Check whether there are obstacles in the pan operating range.
    • Check whether the Hall element on the pan is damaged.
    • Check whether the lead connecting the Hall element on the pan and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the pan is damaged.
    • Check whether the related circuit of the motor drive board on the pan is damage.
  3. Pan Encode Error
    • Check whether the encoder on the pan is damaged.
    • Check whether the lead connecting the encoder on the pan and the PCB board is in poor contact or disconnected.
  4. Tilt Reset Error
    • Check whether the position of the tilt where the magnet is installed falls off or is damaged. Check whether there are obstacles in the tilt operating range.
    • Check whether the Hall element on the tilt is damaged.
    • Check whether the lead connecting the Hall element on the tilt and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the tilt is damaged.
    • Check whether the related circuit of the motor drive board on the tilt is damage.
  5. Tilt Encode Error
    • Check whether the encoder on the tilt is damaged.
    • Check whether the lead connecting the encoder on the tilt and the PCB board is in poor contact or disconnected.
  6. Cyan Reset Error
    • Check whether the position of the cyan color wheel where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the cyan color wheel operating range.
    • Check whether the Hall element on the cyan color wheel is damaged.
    • Check whether the lead connecting the Hall element on the cyan color wheel and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the cyan color wheel is damaged.
    • Check whether the related circuit of the motor drive board on the cyan color wheel is damage.
  7. Magenta Reset Error
    • Check whether the position of the magenta color wheel where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the magenta color wheel operating range.
    • Check whether the Hall element on the magenta color wheel is damaged.
    • Check whether the lead connecting the Hall element on the magenta color wheel and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the magenta color wheel is damaged.
    • Check whether the related circuit of the motor drive board on the magenta color wheel is damage.
  8. Yellow Reset Error
    • Check whether the position of the yellow color wheel where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the yellow color wheel operating range.
    • Check whether the Hall element on the yellow color wheel is damaged.
    • Check whether the lead connecting the Hall element on the yellow color wheel and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the yellow color wheel is damaged.
    • Check whether the related circuit of the motor drive board on the yellow color wheel is damage.
  9. Color Reset Error
  10. Check whether the position of the color wheel where the magnet is installed falls off or is damaged.
  11. Check whether there are obstacles in the color wheel operating range.
  12. Check whether the Hall element on the color wheel is damaged.
  13. Check whether the lead connecting the Hall element on the color wheel and the PCB board is in poor contact or disconnected.
  14. Check whether the motor on the color wheel is damaged.
  15. Check whether the related circuit of the motor drive board on the color wheel is damage.
  16. Rotating Gobo Error
    • Check whether the position of the rotating gobo wheel where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the rotating gobo wheel operating range.
    • Check whether the Hall element on the rotating gobo wheel is damaged.
    • Check whether the lead connecting the Hall element on the rotating gobo wheel and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the rotating gobo wheel is damaged.
    • Check whether the related circuit of the motor drive board on the rotating gobo wheel is damage.
  17. R-Gobo Reset Error
    • Check whether the position of the rotating gobo wheel where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the rotating gobo wheel operating range.
    • Check whether the Hall element on the rotating gobo wheel is damaged.
    • Check whether the lead connecting the Hall element on the rotating gobo wheel and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the rotating gobo wheel is damaged.
    • Check whether the related circuit of the motor drive board on the rotating gobo wheel is damage.
  18. Static Gobo Error
    • Check whether the position of the static gobo wheel where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the static gobo wheel operating range.
    • Check whether the Hall element on the static gobo wheel is damaged. 37E
    • Check whether the lead connecting the Hall element on the static gobo wheel and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the static gobo wheel is damaged.
    • Check whether the related circuit of the motor drive board on the static gobo wheel is damage.
  19. Prism1/2 Reset Error
    • Check whether the position of the prism1/2 where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the prism1/2 operating range.
    • Check whether the Hall element on the prism1/2 is damaged.
    • Check whether the lead connecting the Hall element on the prism1/2 and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the prism1/2 is damaged.
    • Check whether the related circuit of the motor drive board on the prism1/2 is damage.
  20. R-Prism1/2 Reset Error
    • Check whether the position of the prism1/2 where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the prism1/2 operating range.
    • Check whether the Hall element on the prism1/2 is damaged.
    • Check whether the lead connecting the Hall element on the prism1/2 and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the prism1/2 is damaged.
    • Check whether the related circuit of the motor drive board on the prism1/2 is damage.
  21. Animation Reset Error
    • Check whether the position of the animation wheel where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the animation wheel operating range.
    • Check whether the Hall element on the animation wheel is damaged.
    • Check whether the lead connecting the Hall element on the animation wheel and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the animation wheel is damaged.
    • Check whether the related circuit of the motor drive board on the animation wheel is damag
  22. Focus Reset Error
    • Check whether the position of the focus where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the focus operating range.
    • Check whether the Hall element on the focus is damaged.
    • Check whether the lead connecting the Hall element on the focus and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the focus is damaged.
    • Check whether the related circuit of the motor drive board on the focus is damage.
  23. Zoom Reset Error
    • Check whether the position of the zoom where the magnet is installed falls off or is damaged.
    • Check whether there are obstacles in the zoom operating range.
    • Check whether the Hall element on the zoom is damaged.
    • Check whether the lead connecting the Hall element on the zoom and the PCB board is in poor contact or disconnected.
    • Check whether the motor on the zoom is damaged.
    • Check whether the related circuit of the motor drive board on the zoom is damage.
  24. BaseFan1/2/3 Start Err
    • Check whether the fan is not running.
    • Check whether the fan leads are installed in place or disconnected.
    • Check whether the fan is damaged.
    • Check whether there are obstacles in the fan operating range.
  25. BaseFan1/2/3 Stop Err
    • Check whether the fan circuit on the motherboard breaks down.
    • Check whether the component is damaged.
  26. BaseFan1/2/3 Too High
    • Check whether the fan is out of order.
    • Check whether the fan circuit on the motherboard breaks down.
  27. HeadFan1/2/3/4/5/6 Start Err
    • Check whether the fan is not running.
    • Check whether the fan leads are installed in place or disconnected.
    • Check whether the fan is damaged.
    • Check whether there are obstacles in the fan operating range.
  28. HeadFan1/2/3/4/5/6 Stop Err
    • Check whether the fan circuit on the motherboard breaks down.
    • Check whether the component is damaged.
  29. HeadFan1/2/3/4/5/6 Too Low
    • Check whether the fan is out of order.
    • Check whether there are obstacles in the fan operating range.
  30. HeadFan1/2/3/4/5/6 Too High
    • Check whether the fan is out of order.
    • Check whether the fan circuit on the motherboard breaks down.
  31. G Sensor Error
    • Check whether the gravity sensor on board E is damaged .
  32. Ballast Comm Err
    • Check whether the output voltage of the ballast reaches 380V.
    • Check whether the ballast is damaged.
    • Check whether the telecommunication lines are installed in place or disconnected.
  33. Lamp Hot Power Off
    • Check whether the temperature switch of the lamp is off.
    • Check whether the fans are still running properly.
  34. Lamp On Error
    • Turn on the lamp four times. If it still fails, there could be a problem with the software.
  35. Lamp volt. too high
    • Check if the lamp is damaged.
    • Check if the lamp has reached its lifetime.
    • Check if the ballast is damaged
  36. Ballast Temp. high
    • Check whether the ambient temperature exceeds 45℃.
    • Check if the ballast fan speed is too slow.
    • Check if the ballast is damaged.

The position of each fan of the fixture

Troubleshooting

Following are a few common problems that may occur during operation. Here are some suggestions for troubleshooting:

  • A. The unit does not work, no light and the fan does not work
    • Check the connected power and main fuse.
    • Measure the voltage.
    • Check the power indicator to see whether it can be lit up or not.
  • B. Not responding to the DMX controller
    • Check whether the DMX connectors and the DMX cables are connected correctly.
    • Check whether the DMX address is correctly set.
    • If the intermittent DMX signal problem occurs, check whether the XLR socket and the signal cable are well connected.
    • Try it with another DMX controller.
    • Check whether the DMX cables run near or alongside to the high-voltage cables, which may damage or interfere with the signal circuit.
  • One of the channels is not working well
    • The stepper motor might be damaged or the cable connected to the PCB might be broken.
    • The motor’s drive IC on the PCB might be out of condition.
  • D. The lamp is cutting out intermittently
    • The lamp is not working well. Check whether the voltage is too high or too low.
    • The internal temperature may be too high. Replace the cooling fan if necessary.

Fixture Cleaning

  • It is absolutely essential that the fixture is kept clean to ensure the maximum light-output and allow the fixture to function reliably throughout its life. The fixture must be cleaned regularly to avoid dust, dirt and smoke-fluid residues building up on or within the fixture. The cleaning frequency depends on the application environment. Clean the fixture immediately if the dust enters it to avoid damage to the optical lens due to excessive dust.
    • A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should solvents be used.
    • Always dry the parts carefully.
    • Clean the external optical lens at least every 20 days and the internal optical lens every 30 days.

Declaration of Conformity

We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 2014/30/EU.

  • EN 55032: 2015;
  • EN IEC 61000-3-2: 2019;
  • EN 61000-3-3: 2013+A1: 2019;
  • EN 55035: 2017.

Harmonized Standard

  • EN 60598-1: 2015+A1: 2018;
  • EN 60598-2-17: 2018;
  • EN 62493: 2015.
  • Safety of household and similar electrical appliances
  • Part 1: General requirements and tests

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals