HALCYON R947 LED Recessed Luminaire Installation Guide
- June 10, 2024
- HALCYON
Table of Contents
HALCYON R947 LED Recessed Luminaire
INSTALLATION INSTRUCTION
- RISK OF FIRE – Required clearance from structural members and building elements
- Side Clearance to building element (eg timber, joist, or Batten) (SCB): Omm
- Height Clearance to building element (eg timber, joist, or Batten) (HCB): Omm
- Minimum Insulation Clearance to building element (MIC): Omm
Approved clearances
- Note: Omm is required but 25mm is always recommended for optimum product lifespan through effective heat dissipation.
- DO NOT INSTALL THROUGH JOIST, BEAM, RAFTER, OR CEILING BATTEN
- Note: Side/Height Clearance is measured from the heat sink.
Recessed Luminaire Classification:
- IC-F- building insulation that can safely be continuously exposed to 90°C allowed to abut and cover the luminaire.
- For indoor use.
- Luminaire must be installed by a Registered Electrician.
CONSTANT CURRENT WIRE IN SERIES
- CHECK THE MINIMUM LOAD OF THE DRIVER.
- Switch off the mains power supply
- These fittings have been designed to be installed at approximately 300mm above the finished floor level, it is recommended to trial the install height to get the desired effect on the floor before cutting the holes. Cut out 35mm. Cutting holes prior to receiving goods is entirely at the risk of the installer.
- Connect driver to the mains voltage cable (L, N). Do not connect the light to the driver if the driver is live. Inrush Current from the live driver will cause instant light failure. Do not switch the secondary side.
- Halcyon UID drivers can be utilized and are able to be installed under insulation if using a standard driver install above insulation.
- NOTE: if using one driver per R947 we do have a range of mini drivers available that are designed to fit through the cutout. Their codes begin with DRMACC or DRDMACC, please refer to our website for options.
- Carefully install the light into a pre-cut 35mm hole.
- Turn on the mains power and switch on the lighting circuit.
CLASSIFICATION SHEET I IG-F
Classification| ****| IC-F – building insulation that can safely be
continuously exposed to 90°C allowed to abut and cover the luminaire.
---|---|---
- In the vicinity of the recessed luminaire, use an insulation product that:
- (a) Maintains its dimensions and structural integrity when exposed to a temperature of 90°C; and
- (b) Withstands a 30-second needle flame test carried out in accordance with AS/NZS 60695.11.5 with the flame applied to all surfaces of the sample.
Rear fitting may abut structural members and building elements.
- Do not install through or directly into the joist, beam, rafter, or ceiling batten.
- Recessed luminaires and their associated equipment may pose a risk of fire or damage to property if not installed and maintained correctly. Halcyon recommends a clearance of 25mm to building elements for optimum lifespan.
- Halcyon IC-rated luminaires is completely safe to install in sarked timber ceiling linings.
- Halcyon accepts no responsibility if the timber used is not treated correctly and dries out, cracks,s or warps over time due to the constant low heat from the aforementioned “IC Rated” LED recessed lighting.
- This data sheet contains the information necessary to ensure compliance with the New Zealand Electrical Code of Practice for Installation and Maintenance of Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001
- 10 Basalt Place, East Tamaki, Auckland, PO Box 58-501, Botany, Manukau 2163, Auckland, New Zealand Ph (0064 9) 273-9177 Fax (0064 9) 273 9155
- Email:sales@halcyon.co.nz
- Web:www.halcyonlights.co.nz