320 Automatic Chlorine Bromine Feeder
User Manual AUTOMATIC CHLORINE/BROMINE* FEEDER MODEL #320
Features:
- No special venting required.
- Completely enclosed-no escaping gases.
- Positive external no-clog control valve.
- When used with timer, feeder is designed to automatically lower the water level so tablets are not soaking during off period of pump. This allows more efficient use of tablets.
Using Bromine tablets with this device is not NSF certified)
- No equipment damage. Feeds sanitizer directly to pool or spa.
- All parts replaceable.
- To prevent over chlorination during use, completely completely close the control valve and the built in check valve will prevent chemical from being fed into pool or spa.
YOUR FEEDER IS THE MOST EFFICIENT AND TROUBLE-FREE AUTOMATIC FEEDER YOU CAN
BUY, BUT IT CAN ALSO BE DANGEROUS TO YOU AND YOUR EQUIPMENT. PLEASE FOLLOW
INSTRUCTIONS EXACTLY AND HEED ALL CAUTIONS. YOUR SAFETY AND THE PROTECTION OF
YOUR EQUIPMENT IS OUR FIRST CONCERN.
It is important to read all information BEFORE proceeding with the
installation. The information will guide you in installing your feeder
properly and to avoid problems due to improper installation.
IF YOUR POOL OR SPA HAS COPPER PLUMBING … STOP!!
Never install the feeder into copper plumbing as pipe damage will occur. (See
Equipment Safety CAUTION sheet enclosed). NOTE: If heaters are used, a
Fireman’s Switch or equivalent must be Installed to prevent possible damage
and Improper operation of Check Valve and other equipment subject to heat
damage.
INSTALLATION INSTRUCTIONS MODEL #320
Note: Make sure all pumps and timer switches are in the OFF position.
WHERE TO INSTALL YOUR FEEDER
The #320 feeder is designed for permanent installation in the return line of
you new pool or spa and must always be installed after the heater, pool
cleaner, valves, etc. If your pool does not have a heater, then It must be
installed after the Alter or any other piece of equipment.
DAMAGE TO THE HEATER AND OTHER EQUIPMENT COULD RESULT IF HIGHLY CHLORINATED
WATER FLOWS THROUGH
It If your pool is equipped with a solar system it may be necessary to install
a HI FLOW KIT. This kit can be installed if your feeder is not getting
adequate flow and/or pressure through the system. Refer to information on
sheet enclosed. Your feeder may be installed in existing PVC plumbing but will
require a union and/or other fittings. The feeder comes complete for
Installation with 2″ or 1W PVC plumbing. Choose a site in the return line
where feeder can be Installed in a vertical position. Always Install as far
from any metal equipment as practical since fumes, etc. can corrode them. If
optional corrosion resistant check valve Is required refer to Installation
Instructions before next step.
BASIC PLUMBING INSTALLATION INSTRUCTIONS
2″ OR 1½’ PVC PIPE: If feeder is being installed on a pool, spa or pooVspa
combination, correct plumbing procedures must be followed to insure proper
flow through feeder. If pool or spa is plumbed with 2″ PVC pipe, be certain
the pump, filter and heater all have 2″ inlet and outlet fittings. If any part
of the equipment has less than 2″ fittings or pipe, then a minimum of 6″ x 1W
reducer bushings must be installed directly Into the Inlet side of the feeder
using the 2″ x 1 ½ reducer bushings supplied. This will build pressure
directly into the feeder Insuring proper operation. Continue with 2″ PVC pipe
on the outlet side of the feeder.
POOL/SPA COMBINATION: If plumbing and equipment is a full 2″ and the
feeder is being installed on the pool return line of the diverter valve, with
a portion of the water diverted to the spa, install a minimum section of 6″ x
1W PVC pipe directly into the inlet side of the feeder using the 2″ x 1W
reducer bushing supplied. Continue with 2″ PVC pipe on the outlet side of the
feeder. This will compensate for that portion of water being diverted to the
spa.
90° ELBOWS: Plumbing a 90° elbow directly Into the Inlet side of the
feeder may cause turbulence Inside the elbow. This will prevent water from
being scooped Into the feeder. A minimum of a 6″ length of PVC pipe should be
installed between the 90° elbow and the inlet side of the feeder.
2″ PVC : Simply glue feeder to the return line using PVC SOLVENT
CEMENT. Be sure arrows on feeder point in the direction of water flow
returning to the pool or spa. 1½” PVC: Remove (2) x 1W slip reducer
bushings packed inside the feeder and glue into 2″ slip tee on bottom of
feeder. Complete installation by gluing into 1W return fine making sure the
arrows on feeder point in the direction of water flow returning to the pool or
spa. Use only PVC SOLVENT CEMENT. Follow directions on solvent cement
label.Allow to dry. Installation in now armlets.
OPERATING INSTRUCTIONS
Before start up of feeder, your pool should be properly conditioned and the residual should be 1.0 to 1.5 ppm. The water in a newly-filled pool should be properly conditioned to insure maximum effectiveness of the feeder. Consult your local dealer for water conditioning information for your area.
- Remove cap of feeder and fill with proper size tablets. For Pools: 1″ or 3″ dia. tablets For Spas: 1″ dia. tablets in optional Spa Chamber.
- Maidng sure 0-ring Is clean, lubricated with Lifegard Silicone and is an in place, replace cap. Hand tighten only.
- Turn on pump and timer switches for a minimum of 6 to 8 hours.
- Adjust control valve according to your pool/spa size. Use a test kit to determine the chemical residual. It is recommended that the chemical residual be checked daily for the first 5 days. Remember … hot days, higher water temperature or increased pooVspa activity will cause your pooVspa to use more sanitizer. When possible, increase the feed rate a day or two in advance. Because the chlorine demand in your pool/spa varies and is dependent on many factors (sunlight, bather load, water temperature, etc) your valve setting may have to be changed from time to time to adjust to these conditions. For example, the winter setting may be #2 while the summer setting is #3. Check the chlorine residual daily to find the Ideal setting. Note: Higher numbers dispense more chemical. Small gradual changes are Imperative for control.
HOW TO RECHARGE FEEDER
- Turn control valve to the dosed position. SHUT OFF PUMP.
- Wait one minute. This will allow water and fumes to drain from feeder.
- Leave control valve closed and turn on pump. The check valve will prevent water from entering the feeder.
- Remove cap and fill with proper size tablets or sticks. (See Operating Instructions #1)
- Making sure 0-ring Is clean, lubricated with Lffegard silicone and is In place, replace cap. Hand tighten only.
- Open control valve to original setting. Inspect Inlet line below control valve each time feeder is recharged. Replace lines yearly if necessary.
SPECIAL FEATURES AND INSTRUCTIONS
If while using 3″ diameter tablets the #320 feeder does not provide enough chlorine residual, switch to 1″ tablets. The smaller tablet will erode faster producing rnore chlorine residual. If this does not correct the situation, the
320 has been fitted with an optional opening at the top of the feeder (which
Is plugged). To accommodate attachment of the valve and tubing assembly for top entry of water Into the feeder, an additional length of tubing has been included. The following procedure should only be used if the suggested change has not solved the situation. Top entry in normal situations can cause over chlorination.
- Turn off pump and timer switches.
- Remove tubing by unscrewing compression nut at each end of tubing.
- Remove plug at top of feeder directly above control valve.
- Remove control valve. If nipple stays in valve, carefully remove by using pliers at the center of nipple. There Is no need to remove the 90° tube fittings.
- Wrapplug with 2 or 3 wraps of threaded tape In opposite direction of tightening. Screw Into opening where control valve was attached. Hand tighten plus 2 or 3 turns. Do not overtighten.
- Wrap threads of nipple with threaded tape.Thread nipple into top opening. Finger tighten only. Thread valve onto nipple. After nipple starts to turn from tightening valve, 2 to 3 more toms is enough. The nipple or valve can be broken by overtightening.
- Slide compression nut over long section of tube. Slide tube over tapered part of 90″ tube fitting and tighten. Hand tighten only. Repeat for other end of tubing.
- Set control valve to #1. Turn on pump and timers. Check residual daily to determine proper setting. Small gradual changes are Imperative for control.
BELOW WATER LEVEL INSTALLATION
Feeder should be installed above water level whenever practical. If installed
below water level, a drain valve must be installed to prevent spillage and
dangerous splash back of high chlorinated water during recharging. Drill and
tap a Y.” MPT hole at the same level the control valve is located. Make sure
there is no water or tablets inside the feeder before drilling. Install
optional drain valve, Part R172060, or suitable chemical resistant drain
valve.
BELOW WATER LEVEL RECHARGING INSTRUCTIONS
- Shut off pump and timer switches.
- Shut off control valve.
- Place a clean container under drain and open drain valve.
- Exercise extreme caution when opening or servicing feeder. Do not inhale fumes. Wear protective gear. Remove cap. Water will now drain from feeder. Empty container back into pool or spa.
- Close drain valve. fill with proper size tablets or sticks.
- Making sure 0-ring is dean, lubricated with !AsgardSiliconeand In in place, replace cap.
- Turn on pump and timer switches.
- Reset control valve to original setting. Inspect Inlet and outlet line each time feeder is recharged. Replace lines yearly if necessary.
DANGER
READ CAREFULLY
This feeder is designed to use only CLEAN Trichlor-s-trizinetrione OR CLEAN
Bromine tables – slow dissolving type. Never use dirty tablets. UNDER NO
CIRCUMSTANCES MIX Trichlor or Bromine with Calcium Hypochlorite, with other
forms of concentrated chlorine or with other chemicals. Keep inside of feeder
clean of dirt and debris at all times. FIRE AND/OR EXPLOSION MAY RESULT.
NEVER use oils or grease to lubricate o-ring. Oil in contact with Trichlor OR
Bromine may result in FIRE. Lubricate o-ring with Lifegard Silicone o-ring
Lubricant ONLY, available at your dealers. If shock treatments or Algaecides
containing chemicals other than sanitizers tablets in feeder must be used,
turn off Feeder OR remove tablets until the shock or Algae treatment is
complete and all granules have dissolved. Failure to do so may result in
granules mixing in feeder causing FIRE AND/OR EXPLOSION. The shock or algae
treatment dissolved in water is safe with tablets. If you are not the original
owner of this feeder, not sure which chemicals was used, or if dirt and/or
debris inside feeder, be SAFE and flush thoroughly with fresh water. CAUTION
SHOULD BE USED WHEN REMOVING CAP. DO NOT INHALE FUMES .
CALCIUM HYPOCHLORITE IS NOT TO BE USED IN ANY FORM. Use of chemicals other
than listed by manufacturer may be hazardous.
Bromine Standpipe Installation To increase erosion of small bromine tablets,
install Bromine Standpipe as follows:
- Remove screen from bottom of chamber exposing check valve (F)
- Insert adapter (T) into check valve opening.
- Cut supplied 5/8′ black tube (Q) to 6″ length and push tube into adapter opening.
YOU MAY SUBSTITUTE BROMINE TABLETS OR STICKS FOR TRICHLOR IN THIS
FEEDER. DO NOT MIX.
CALCIUM HYPOCHLORITE IS NOT TO BE USED IN ANY FORM.
IMPORTANT OPTION.
SEE CORROSION CAUTION SHEET.
CAUTION Do not install feeder into copper plumbing. Pipe damage could
occur. Never install feeder before heater. Heater damage could occur.
NSF 50 Certified for public or residential use in Swimming Pools, Spas or Hot
Tubs using 1″Trichlor Tablets and when used with a flow indicating device such
as Model# R172276. Output rating for Bromine is not NSF 50 Certified.
Technical Support:800-831-7133
320 CHLORINE / BROMINE FEEDER PARTS BREAK, DOWN DRAWING
Item | Qty. | Part No. | Description |
---|---|---|---|
A | Optional | R172052 | Cap wrench |
B | 1 | R172008W | 3″ Threaded cap |
C | 1 | R172009 | 3″ 0-Ring |
D | 1 | R172331 | #320 Body only (new) |
E | 1 | R01052 | Lock screw |
F | 1 | R172248 | Check valve |
G | 1 | R172317 | Divertor tee |
H | 1 | R172256 | ‘/2″ x Short MPT nipple |
I | 1 | R172086 | ‘/2″ Chlorine control valve |
J | 2 | R172272 | 1/2″ NPT x tube fitting w/nu |
K | 1 | R172091 | 5 / 8 ” OD Chlorinator tube |
K1 | 1 | R171097 | Tube support spring |
*L | 2 | R172210 | 2″ x 11/2″ s x s bushing |
M | Optional | R172037 | Spa chamber |
N | 1 | R172036 | Silicone lubricant |
** O | 1 | 210396 | Screen |
P | 1 | R172134 | 1/2″ MPT PVC plug |
Q | 1 | R172253 | 5 / 8 ” OD 18″ tube (optional top feed) |
R | 1 | R172319 | Bottom 0-ring |
S | Optional | R17228 | 11/2″ Corrosion resistant check valve |
T | 1 | R172048B | Standpipe adapter |
*Not used with 2″ PVC, for Ph” PVC only. Be sure screen has not come loose in shipment—if loose: Simply snap over 4 posts in bottom of chlorinator to replace.
NOTE:** To service check valve F, Remove lockscrew E, and unscrew (counter-
clockwise) D chlorinator body from G divertor tee.
Typical Installation #320 with heater.
Typical Installation #320 without heater
HI FLO FEEDER KIT 1099 FOR MODELS #320 & #322
DIRECTIONS
- Turn off pump and timer switches.
- Loosen compression nut and remove Feeder tube and 90° elbow from the diverter tee at base of Feeder.
- Using thread seal tape as thread sealant, wrap ‘A” MPT plug threads (1) with several turns of the tape only. Install in place place of 90° elbow on diverter tee.
- Disconnect other end of Feeder tube from control valve 90° elbow, by loosening compression nut. Use the compression nuts from old tube to attach new 6′ section (2).
- Push compression nut over tubing end, then push tubing onto tapered end of elbow. Tighten nut firmly by hand.
- Connect other end of plumbing. IF POOL/SPA HAS A HEATER, INSTALL BETWEEN FILTER AND HEATER. IF YOUR POOUSPA HAS A SOLAR SYSTEM, INSTALL BEFORE SOLAR SYSTEM INLET LINE. IF NO HEATER, INSTALL BETWEEN PUMP AND FILTER. Drill 9/16″ hole in plumbing, remove burrs, and install saddle clamp assembly. (See illustration) Tighten clamp with screwdriver. Slide small stainless steel clamp #3 over tubing #2 and slide tubing over saddle tube fitting #4. Secure tubing to fitting by tightening camp with screwdriver. Make sure clamp is below rib at end of saddle tube fitting.
- To install ‘A” CHECK VALVE, cut tube approximately 6″ away from plumbing connection. Remove compression nuts from check valve. Slide nuts over both ends of tube. Insert check valve ends into both pieces of tubing and tighten compression nuts firmly by hand. Be sure arrow “FLOW” is pointing toward the Feeder.
HI FLO FEEDER KIT #R171099 PARTS BREAKDOWN DRAWING
Item | Quantity | Part No. | Description |
---|---|---|---|
1 | 1 | R172134 | Plug, W MPT |
2 | 6″ | R172093 | Tube, 1/2″ ID Chlorinator |
3 | 1 | R175013 | Clamp, S.S. Tubing |
4 | 1 | R171162 | Fitting, Saddle Tube |
5 | 1 | R172263 | Gasket, Saddle |
6 | 1 | R172264 | Clamp, Saddle |
7 | 1 | R172324 | Valve, ‘A” Tube check |
NOTE: When using this kit with a pool/spa combination (to prevent draining spa) shut off Feeder control valve when only the spa is in use.
EXTENSIONS
- Going on vacation?
- Need more chlorine?
- Filling Chlorinator/Brominator too frequently?
LIFEGARD CHLORINATOR EXTENSIONS SOLVE THE ABOVE PROBLEMS BY :
- Increasing tablet capacity.
- Larger chamber size allows more erosion of tablets. (See special instructions below)
The 10″ extension doubles and the 20″ extension triples (approximately) the
capacity and time between refills. *AVAILABLE THROUGH DEALERS ONLY
NOTE: On free standing #300 series chlorinators, the base of the
chlorinator should be secured to prevent the possibility of the chlorinator
tipping over due to increased height.
INSTALLATION INSTRUCTIONS
- Follow recharging instructions to the point of filling with tablets
- Making sure 0-Ring is clean, lubricated with silicone and in place, screw on extension tightly and secure with lock screw. (You may wish to wait until back in operation before tightening screw to insure against leaks).
- Fill with tablets and continue with normal recharging procedure.
SPECIAL INSTRUCTIONS:
The large chamber size will result in more chlorine being dispensed at the
same valve setting, therefore, once installed, several days monitoring will be
necessary to readjust chlorinator output.
*Does not apply to large capacity #300-19 or #300-29.
Parts Breakdown Drawing
Item | Quantity | Part No. | Description |
---|---|---|---|
1 | 1 | R172087 | Lockscrew (bottom collar) |
2 | 1 | R172009 | 0-Ring |
#R172288 11/2″ & 2″ SLIP SPRING CHECK VALVE
- Special corrosion resistant 1W & 2″ slip spring check valve can be used to check back flow of fluids, air, etc.
- Full free flow design
- Special Spring and Seal for corrosive applications.
- Enclosed spring insuring free operation.
- Very effective when used in conjunction with chlorinator to check back flow of chemicals to pool/spa equipment, preventing corrosion problems and damage.
- Can be mounted in any position.
Typical check valve installation
NOTE: If heaters are used, a Fireman’s Switch or other safety device must be
installed to prevent possible damage and improper operation of Check Valve and
other equipment subject to heat damage.
EQUIPMENT SAFETY
CAUTION! PLEASE READ CAREFULLY
Since most pool’s plumbing is not airtight, and a mixture of air and chlorine
is highly corrosive to metals, it is important to protect these items from
corrosion in the OFF period when no circulation is taking place. (There is no
chance for chlorine corrosion when the circulating system is in operation.)
Of course, corrosion or erosion of metal components can still occur
independently of any chlorinator installation for the following reasons:
- Water velocity too high.
- Water pH less than 7.2.
- Total alkalinity less than 100 PPM.
If your pool or spa has any of the following equipment, special plumbing procedures must be followed for safe operation:
- Brass or bronze gate, rotary or backwash valves.
- The preceding valves constructed of PVC or other plastic material with metallic shafts.
- Filters, heaters, heat exchanges or other items with metallic tanks, shafts, coils or tubes.
- NOT FOR USE IN COPPER PLUMBING.
Installation of the OPTIONAL #R172288 positive seal, corrosion resistant check
valve SHOWN ON REVERSE SIDE will prevent the backflow of corrosive liquids and
gases that can damage equipment containing metallic components. Examples
listed above.
WARNING: If your pool is equipped with a permanent built in pool-cleaning
system, damage could occur to that system if materials are not compatible with
low pH Tri-Chloro feeders. Check with manufacturer for compatibility.
13950 Mountain Ave., Chino, CA 91710
1620 Hawkins Ave., Sanford, NC 27330 •
919-566-8000
10951West Los Angeles Ave., Moorpark, CA, 93021 •
805-553-5000
All indicated Pentair trademarks and logos are property of Pentair Inc.
or its global affiliates in the U.S.A. and/or other countries.
Third party registered and unregistered trademarks and logos are the property
of their respective owners.
@ 2020 Pentair. All rights reserved.
This document is subject to change without notice.
www.pentair.com