Before Installation

  1. Make sure you have sufficient water supply, pressure, and flow. Connect pipes to primary water source.
  2. Install master valves, pressure regulators, and backflow preventers as needed. For system design information, refer to the Rain Bird lrrigation Design Guide. Refer to local building codes for additional requirements.
  3. Flush the system thoroughly until the water from the submain runs clear.

Connect Adapters to Valve

  1. To make a watertight seal, wrap 1 ½ to 2 turns of Teflon tape around the threads on two male x slip adapters (A) or on the male threads of the valve (B; MM and MB models)

  2. Screw the adapters into the valve water ports and hand tighten.

  3. Carefully tighten the adapters one to two additional turns past hand-tight.
    CAUTION: Do not over-tighten the adapters. You may damage the valve or block the exit ports.
    Connect Valve to Pipes

  4. Carefully apply a small amount of solvent cement to the inside of the adapter (A, threaded connector) or valve inlet port (B, slip connector). Apply a small amount of cement to the outside of the water supply pipe. Then attach the valve to the pipe. The valve solenoid MUST be on the downstream side (C). For DV-A and DVF-A models, connect the supply pipe to the bottom inlet (D).
    CAUTION: Use only a small amount of solvent cement.
    Excess cement can damage the valve internally.

  5. Cement the lateral pipe to the adapter (A, threaded connector) or valve outlet port (B, slip connector), as described in step 7.

  6. To attach an MB model valve to low-density polyethylene pipe, cut the pipe square and clean. Slip one or two clamps over the poly pipe.
    If necessary, carefully heat the poly pipe for easier installation. Slip the poly pipe completely over the barb (A). Then clamp (B) the pipe securely to the barb for a leak-proof seal.

Connect Valve Wires

  1. Select a wire gauge that meets electrical specifications. Multi-strand, direct-burial wire is recommended. Refer to local building codes for additional requirements.

  2. Use a watertight connector to connect one lead on each valve to a common wire (A). Either lead may be used. All valves on the same controller can share the same common wire.
    Use a watertight connector to connect the second lead on each valve to a power wire (B). Each power wire must be run separately to the controller.

  3. Connect the shared common wire (A) to the common terminal on the controller. Connect one power wire from each valve (B) to a station terminal on the controller.
    Operate Valve Manually

  4. To open the internal bleed, turn the solenoid handle (A) counterclockwise ¼ to ½ turn. Be sure to re-tighten the  solenoid completely. Always use the solenoid handle, which is designed to shut the valve off completely and keep it from “weeping.”

To reduce flow (DVF models only), turn the flow control stem (B) clockwise. Use your fingers or a slot-head screwdriver. To increase flow, turn the stem counterclockwise.
To open the external bleed, turn the bleed screw (C) counterclockwise two turns. Use the external bleed to flush the valve when you first start the system. Turn the screw clockwise to close it.

Operating Ranges

| 075-DV| 100-DV, 100-DVF, 100-DV-MM¹,100-DV-MB¹, 100-DVF-MB¹, 100-DV-A, 100-DVF-A, 100-DV-SS, 100-DVF-SS
---|---|---
Flow| 0.2 – 22 GPM
(0,05 – 5,0 m³/h or 0,01 – 1,39 l/s)| 0.2 – 40 GPM
(0,05 – 9,08 m³/h or 0,O1 – 2,52 I/s)
Pressure| 15 – 15O psi
(1 – 10 bar)| 15 – 15O psi
(1 – 10 bar)

  1. DV/DVF male x male (MM) and male x barb (MB) are not recommended for flows exceeding 30 GPM (6,8 m³/h or 1,9 I/s).
  2. For flows below 3 GPM (0,75 m³/h or 0,21 I/s), or any Landscape Drip application, use RBY-100-200MX filter installed upstream.

Troubleshooting

Symptom Solution

Valve won’t shut off completely.
Sprinklers “weep.”| Tighten the solenoid completely (1⁄4 turn beyond hand tight). Use the solenoid handle, which is specifically designed to shut the valve off completely and keep it from “weeping.” Also tighten the bleed screw and bonnet screws.
Use the external bleed screw to flush the valve. If performance does not improve, turn off water.
Unscrew bonnet screws and remove bonnet. Remove diaphragm and clean it in clear water.
Reinstall diaphragm and bonnet. If necessary, replace the diaphragm with kit number 210746-03.
Valve won’t open.| Check water source, controller power, and flow control to make sure they are open.
Turn off water. Unscrew bonnet screws and remove bonnet. Inspect body for debris. If filter is missing from diaphragm, replace diaphragm with kit number 210746-03.
Turn off water. Remove solenoid and replace with a known working solenoid. If the valve still won’t open, replace the solenoid.
Valve slams on/off (water hammer).| Check system water pressure. If pressure is greater than 80 psi (5,5 bar), install a pressure regulator on the line before the valve to reduce water pressure.

NOTE: During winter shutdown, drain the system to protect DV valves from freezing. Failure to properly drain lines may damage the valves. Be sure to comply with all local guidelines.

Rain Bird Corporation
6991 E. Southpoint Road
Tucson, AZ 85756 USA
Phone: 520-741-6100
Fax: 520-741-6522| Rain Bird Europe SNC
Rain Bird France SNC
900, rue Ampère, B.P. 72000
13792 Aix en Provence Cedex 3 France
Tel: +33 4 42 24 44 61
Fax: +33 4 42 24 24 72
rbe@rainbird.eu
www.rainbird.eu
rbf@rainbird.eu
www.rainbird.fr| Rain Bird Mexico S. de R. L de C.V
Calzada Juan Gil
Preciado # 2450, 15A
Parque Ind. Ecopark
Colonia El Tigre CP45100
Zapopan, Jalisco, Mexico
Tel: +52 333 364 4785
Fax: +52 333 364 4787
---|---|---
Rain Bird Corporation
970 West Sierra Madre Avenue
Azusa, CA 91702 USA
Phone: 626-812-3400
Fax: 626-812-3411| Rain Bird Deutschland GmbH
Oberjesinger Str. 53
71083 Herrenberg-Kuppingen
Deutschland
Tel.: +49 07032 99010
Fax: +49 07032 990111
rbd@rainbird.eu
www.rainbird.de| Rain Bird (Australia) Pty. Ltd
10 Mareno Rd.
TULLAMARINE VIC 3043
Australia
Tel: +61 (0)3 8336 6777
Fax: +61 (0)3 9338 1699
sales@rainbird.com.au
www.rainbird.com.au
Rain Bird International
1000 W. Sierra Madre Ave
Azusa, CA 91702 USA
Phone: 626-963-9311
Fax: 626-852-7343| Rain Bird Ibérica S.A.
Polígono Ind. Pinares Llanos
c/Carpinteros, 12, 2°C
28670 Villaviciosa de Odón, Madrid
España
Tel: +34 91 632 48 10
Fax: +34 91 632 46 45
rbib@rainbird.eu
www.rainbird.es
portugal@rainbird.eu
www.rainbird.pt| Rain Bird Brasil Ltda
Rua Piaui, 740 Marta Helena
Uberlandia, MG 38402020
Brasil
Tel: +55 34 3212 8484
Fax: +55 34 3213 5469
Rain Bird Technical Services
(800) RAINBIRD (1-800-724-6247)
(U.S. and Canada)| Rain Bird Sverige AB
Fleningevägen 315
260 35 Ödåkra
Sweden
Tel: +46 42 25 04 80
Fax: +46 42 20 40 65
rbs@rainbird.eu
www.rainbird.se| Rain Bird Trading (Shanghai) Company Limited
Rm 1008, E1
Yuan Chen Xin Bldg 12
Yumin Rd, Chaoyang District
Beijing, 100029 China
Tel: +86 10 8225 1759
Fax: +86 10 8225 1301
www.rainbird.com.cn
Specification Hotline
800-458-3005 (U.S. and Canada)
The Intelligent Use of Water™
www.rainbird.com| Rain Bird Turkey
Ístiklal Mahallesi
Alemdağ Caddesk No. 262
34760 Ümraniye, Ístanbul
Türkiye
Tel: +90 216 443 75 23
Fax: +90 216 461 74 52
rbt@rainbird.eu
www.rainbird.com.tr| Rain Bird Jebel Ali
JAFZA- LOB14- Office 318
P.O.Box: 261771- Dubai – UAE
Tel: +971 4 8819671
Fax: +971 4 8819672

® Registered trademark of Rain Bird Corporation.
© 2011 Rain Bird Corporation 7/11
P/N 231576-B

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals