BC Beam Clamp Installation

1. Install BC Beam Clamp onto a Maximum Flange Thickness of 1/2″ [13 mm].
2. Tighten Beam Clamp Set Screw to 20 in.-lbs. [2.25 N-m]

WARNING:

  1. nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Instruction sheets are available at
    www.nVent.com and from your nVent customer service representative.

  2. nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.

  3. All instructions must be completely followed to ensure proper and safe installation and performance.

  4. Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property
    damage, serious bodily injury and/or death, and void your warranty.

  5. Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment.

  6. All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any
    other purpose.

NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.

The customer is responsible for:
a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified
engineer.
c. Using appropriate industry standard hardware as noted above.

SAFETY INSTRUCTIONS:

All governing codes and regulations and those required by the job site must be observed.
Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.

TECHNICAL SUPPORT:
www.nVent.com

INSTRUCTION SHEET

Conduit Clip Installation
1. Select the appropriate Latching Hole from Sizing Chart
2. Fit Conduit into Conduit Clip
For the 16M, compress the Bottom Gripping Tabs prior to
installing the 3/4″ RIGID and 1″ RIGID Conduit
3. By Hand or with Channel Lock Pliers, snap Locking Tab into
the desired Latching Hole

Global Part
Number

|

Local Part
Number

| Sizing Chart
---|---|---
Latch “A”|

Latch “A” Latch “B”

6M| 170790| 3/8″ EMT, IMC & RIGID| N/A
812M| 177130| 3/4″ EMT, IMC & RIGID|

1/2″ EMT, IMC & RIGID

16M| 170100| 1″ EMT, IMC & RIGID|

3/4″ EMT, IMC & RIGID

20M| 170110| 1-1/4″ RIGID|

1-1/4″ EMT & IMC

24M| 170120| 1-1/2″ RIGID|

1-1/2″ EMT & IMC

32M| 170130| 2″ RIGID| 2″ EMT & IMC

For Thread Impression Conduit Clip’s, select the appropriate Latching
Hole from the Sizing Chart based on the Conduit Size being used.

BC Beam Clamp

| | | |

Static Load Rating (lb [N])

| | | |
---|---|---|---|---|---|---|---|---

Global Part
Number

|

Local Part
Number

|

Figure
No.

|

Flange Thickness
(in [mm])

| Ult. Static Load Rating (lb [N])
F1| F2| F3| F4| F5| F6| F7
BC|

N/A

|

1

|

1/2″ [13] Max

|

100
[445]

|

100
[445]

|

75
[334]

|

25
[111]

|

25
[111]

|

25
[111]

|

25
[111]

BCR
EBC| 170380

beam installation

Indicated Loads are Static Load Limits or Ultimate Static Load Limits and should not be combined.

nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.

BC Beam Clamp with Bottom Mount Conduit Clip

Global Part
Number| Local Part
Number| Figure
No.| Description| Static Load
Rating (lb [N])
---|---|---|---|---
BC6M|

N/A

|

2

| 3/8″ [10]conduit to 1/2″ [13] maximum flange|

100 [445]

BC812M| 1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange
BC16M| 3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange
BC20M| 1-1/4″ [32]conduit to 1/2″ [13] maximum flange
BC24M| 1-1/2″ [38]conduit to 1/2″ [13] maximum flange
BC32M| 2″ [51]conduit to 1/2″ [13] maximum flange
EBC6M| 172580| 3/8″ [10]conduit to 1/2″ [13] maximum flange
EBC812M| 160200| 1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange
EBC16M| 172590| 3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange
EBC20M| 172600| 1-1/4″ [32]conduit to 1/2″ [13] maximum flange
EBC24M| 172610| 1-1/2″ [38]conduit to 1/2″ [13] maximum flange
EBC32M| 172620| 2″ [51]conduit to 1/2″ [13] maximum flange

BC Beam Clamp with Side Mount Conduit Clip

Global Part
Number| Local Part
Number| Figure
No.| Description| Static Load
Rating (lb [N])
---|---|---|---|---
BC812MSM|

N/A

|

3

| 1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange|

25 [111]

BC16MSM| 3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange
BC20MSM| 1-1/4″ [32]conduit to 1/2″ [13] maximum flange
BC24MSM| 1-1/2″ [38]conduit to 1/2″ [13] maximum flange
BC32MSM| 2″ [51]conduit to 1/2″ [13] maximum flange
EBC6MSM| 172650| 3/8″ [10]conduit to 1/2″ [13] maximum flange
EBC812MSM| 160180| 1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange
EBC16MSM| 172660| 3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange
EBC20MSM| 172670| 1-1/4″ [32]conduit to 1/2″ [13] maximum flange
EBC24MSM| 172680| 1-1/2″ [38]conduit to 1/2″ [13] maximum flange
EBC32MSM| 172690| 2″ [51]conduit to 1/2″ [13] maximum flange

BC Beam Clamp with Side Mount Push Clip

Global Part
Number| Local Part
Number| Figure
No.| Description| Static Load
Rating (lb [N])
---|---|---|---|---
BC8PSM|

N/A

|

4

| 1/2″ [13] EMT conduit to 1/2″ [13] maximum flange|

25 [111]

BC12PSM| 3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange
BC16PSM| 1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange
EBC8PSM| 172730| 1/2″ [13] EMT conduit to 1/2″ [13] maximum flange
EBC12PSM| 172740| 3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange
EBC16PSM| 172750| 1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange

BC Beam Clamp with Bottom Mount Push Clip

Global Part
Number| Local Part
Number| Figure
No.| Description| Static Load
Rating (lb [N])
---|---|---|---|---
BC8P|

N/A

|

5

| 1/2″ [13] EMT conduit to 1/2″ [13] maximum flange|

25 [111]

BC12P| 3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange
BC16P| 1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange
EBC8P| 172700| 1/2″ [13] EMT conduit to 1/2″ [13] maximum flange
EBC12P| 172710| 3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange
EBC16P| 172720| 1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange