PREFACE
Thank you for purchasing the new UTi320E Professional Thermal Imager. In order t o use this product safely and correctly, please read this manual thoroughly, especially the Safety Instructions part.
After reading this manual, i t is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.
LIMITED WARRANTY AND LIABILITY
Uni-Trend guarantees that the product is free from any defect in material and workmanship within one y e a r from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination and improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.
This warranty is the only compensation you can obtain. Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage o r loss caused by any reason or speculation. As some areas or countries do not allow limitations on implied warranties and incidental or subsequent damage, the above limitation of liability and stipulation may not apply to you.

Technical Specifications

Sensor Uncooled vanadium oxide
Mode Automatic gain
Temperature Range -40~400°C
Accuracy -10°C~400°C,±2°C/±2%

(Whichever is greater,at 25°C ambient temperature)
Emissivity| 0.95 (default) 0.01~1.00
Pixel size| 12um
Thermal imaging pixels| 320*240 (76800)
Visible light pixels| 2 million
Palettes| lron,Rainbow,white Hot,Red hot,Black Hot,Lava,Rainbow HC
Infrared spectrum bandwidth| 8~14um
Field of view| HFOV 56°
IFOV| 3mrad
Lens focal length| 4.0mm
Focus mode| Focus free
Sensitivity| <65mK@25`C
Frame rate| 9Hz
Digital zoom| 2x, 4x
Temperature analysis| Point, areas (large, medium and small), line
Isotherm| Auto/Manual adjustment
Temperature display| Center point temperature, high/low temperature tracking
Unit| ºC (default)/ F/K
High and low temperature alarm| √ (LED alarm or screen alarm symbol)
Image modes| Thermal, visible, blending, PIP
Image capture mode| Take photos
Image save format| JPG
Image viewing| Temperature analysis, change palettes, remarks
USB communication| Type-C USB (photo download and charging)
WiFi| √
PC screen projection| √
PC analysis software| √(real-time image, photo download and analysis)
Mobile APP| Aphoto download and analysis)
Flashlight| √
Language| Chinese/English
Certificates| CE FCC UKCA
Operating temperature| 0°C-508C (32 F-122 F)
Storage temperature| -10°C-60t (14 F-140 F)
Operating humidity| 10%~95%RH (non-condensing)
IP rating| IP54
Drop test| 2m

Product Structure

1. USB Type-C interface
2. Upper housing
3. Lower housing
4. SD card slot
5. Interface protection cover
6. LCD
7. Power
8. Flashlight button
9. Left
10. Up| 11. View images
12. Return
13. Right
14. Down
15. SET
16. Bracket screw hole
17. Infrared camera lens
18. Flashlight
19. Visual light camera lens
20. Trigger
---|---

UNI-T UTi320E Handheld Thermal Imaging Camera - FIG
1

LCD Indicators/Icons

Display size: 3.5″ IPS
Display resolution: 640« 480

UNI-T UTi320E Handheld Thermal Imaging Camera - FIG 2

Item Description Item Description
1 Markup 8 Lowest temperature spot
2 Image 9 Range bar
3 Palette 10 Upper range of palette
4 Measure 11 Battery status
5 Villa 12 Center point temperature
6 System 13 Highest temperature spot
7 Lower range of palette 14 Center point marker

Power on/off

Long press the power button for 5s to turn on/off the thermal imager (it needs 30 minutes warm-up time when the device is just turned on or not used for a long time, or the measurement environment changes). When the battery is low, a low battery indicator will show on the LCD, which means the thermal imager should be turned off and the battery should be charged. When the thermal imager is in low battery status for a long time, the device will automatically shut down.

Main Menu Configuration Options

In the main interface:

  1. Press the SET button to open the main menu.
  2. Press the left/right button to step through submenus.
  3. Press the SET button to open the selected submenu.
  4. Press the left/right button to step through setting items i n the submenu.
  5. Press the SET button to confirm the selected setting item.
  6. Press the return button to return to the previous interface and save the setting.
  7. Press the return button again to return to the main interface.

Main Menu

UNI-T UTi320E Handheld Thermal Imaging Camera - FIG 5

Submenu

UNI-T UTi320E Handheld Thermal Imaging Camera - FIG 6

Markup

In the main interface, press the SET button to open the main menu. Press the left/right button to select “Markup”. Press the SET button again to open the submenu of “Markup”.
In the submenu, press the left/right button to select a submenu option. Press the SET button to perform the selected function, and press it again to exit.
Centre: A center point marker will show on the middle of the screen.
Hi Spot: A high temperature tracking box will show on the highest temperature spot.
Lo Spot: A low temperature tracking box will show on the lowest temperature spot.
Value: The temperature of the high/low spot will show below the tracking box.

Image

In the main interface, press the SET button to open the main menu. Press the left/right button to select “Image”. Press the SET button again to open the submenu of “Image”. In the submenu, press the left/right button to select a submenu option. Press the SET button to perform the selected function.
Thermal: The image will switch to the thermal imaging mode.
Digital: The image will switch to the visual light mode.
Fusion: The image will switch to the fusion mode (press the left/right button to adjust the mix proportion, and left/right button to adjust the mix distance).
PIP: The image will switch to the PIP mode. Press the left/right button to move the position or stretch the size of PIP.
QR: Users can manually input the QR code or scan the QR code. Select “cancel” to return to the main interface.

Palette

In the main interface, press the SET button to open the main menu. Press the left/right button to select “Palette”. Press the SET button again to open the submenu of “Palette”. Press the left/right button to step through seven optional palettes: iron, Rainbow, whitehot, redhot, blackhot, lava, Rain.HC.

Measure

In the main interface, press the SET button to open the main menu. Press the left/right button to select “Measure”. Press the SET button again to open the submenu of “Measure”. In the submenu, press the left/right button to select an analysis object (Point, Line, Rect., Circle). Press the SET button to add the selected object. The submenu also includes three other functions: Choose (this function can only be used if an analysis object is added), Clear, Preset. After adding an analysis object, a submenu will appear. The optional functions in the submenu are choose, move, stretch (this function cannot be applied to point objects), diff (point objects can only be compared with point objects; the comparison information will be displayed on the right side), delete (delete the selected object). The temperature information of the added object will be displayed on the left. When a line object is selected, its temperature change graph will be displayed in the lower left corner.

Press the “SET” button to perform the “clear” function, and all the analysis objects in the current interface will be cleared. When there is an analysis object, press the “SET button” to perform the “preset” function, and a box “Save tool” will pop up. Select “OK” to save the analysis object. The preset tool can be used directly next time.
If there is no temperature measurement and analysis object on the main page, press the “SET” button to select a preset tool, and a prompt box of “Read tool” will pop up. Select Confirm, and the preset tool saved last time will be added to the main page.
When there is no analysis object in the main interface, press the “SET” button to perform the “preset” function, and a box “Read tool” will pop up. Select “OK” and the preset tool will be added to the interface.UNI-T UTi320E
Handheld Thermal Imaging Camera - FIG 13 Note: The maximum number of point objects that can be added is 5 (line: 1; Rect.: 3; circle: 3). The total number of analysis objects added cannot exceed 6. When it exceeds 6, a box “Outnumber” will pop up.

Isotherm

In the main interface, press the SET button to open the main menu. Press the left/right button to select “Isotherm”. Press the SET button again to open the submenu of “Isotherm”. The options in the submenu are: Auto, Ratio, Below, Above, Section, Manual.

Settings

Press the SET button to enter the submenu. Press the up/down button to select a setting item, and press the SET button to enter the interface of this item.
11.1 Camera Model
In the setting interface, select “camera model” and press the SET button to enter the submenu. Press the up/down button to select Single Shot/Time-lapse. In the Time-lapse mode, press the up/down button to adjust the Time-lapse interval (10s-1000s).

UNI-T UTi320E Handheld Thermal Imaging Camera - FIG 16

11.2 Units
In the setting interface, select “units” and press the SET button to enter the submenu. Press the up/down button to select temperature/distance. When selecting temperature, press the up/down button to change the units (“F 11Q°C). The distance unit cannot be changed.UNI-T UTi320E Handheld Thermal
Imaging Camera - FIG 17

11.3 Parameter
In the setting interface, select “parameter” and press the SET button to enter the submenu. Press the up/down button to select Emissivity/ObjectDistance. Press the SET button to select the parameter to be modified, and press the up/down button to adjust the parameter value. When setting the object distance, press the SET button to enter its submenu, and then press the SET button and the up/down button to modify the parameter.UNI-T UTi320E Handheld
Thermal Imaging Camera - FIG 18 11.4 HMO Alert
In the setting interface, select “HI/LO Alert” and press the SET button to enter the submenu. Press the up/down button to select HI/LO/LED alarm. When setting HI/LO, press the up/down button to select HI value/LO value, press the SET button to modify, and press the up/down button to adjust the value (-40″0-400T2).UNI-T UTi320E Handheld Thermal Imaging Camera - FIG
19When the measured temperature exceeds the HI value, a red triangle will pop up. When the measured temperature is lower than the LO value, a green inverted triangle will pop up.

UNI-T UTi320E Handheld Thermal Imaging Camera - FIG 20 11.5 QR CODE
In the setting interface, select “OR code” and press the SET button to enter the submenu. Press the up/down button to select a QR code. Press the SET button to change the code name or reset the code.UNI-T UTi320E Handheld
Thermal Imaging Camera - FIG 21 11.6 Language
In the setting interface, select “Language” and press the up/down button to select Simplified Chinese/English. 11.7 Date &Time
In the setting interface, select “Date&Time” and press the SET button to enter the submenu. Press the SET button to modify Time format/Date/Time, and press the up/down button to adjust the value.UNI-T UTi320E Handheld Thermal
Imaging Camera - FIG 23 11.8 Wi-Fi
In the setting interface, select “Wi-Fi” and press the SET button to enter the submenu. Press the SET button to turn on the Wi-Fi Hotspot, press the down button to select the ID and password, and press the SET button to confirm.

UNI-T UTi320E Handheld Thermal Imaging Camera - FIG 24

11.9 USB modo
In the setting interface, select “USB modo” and press the SET button to enter the submenu. Press the up/down button to select USB storage/USB projection, and press the SET button to confirm.UNI-T UTi320E Handheld Thermal Imaging
Camera - FIG 25 11.10 Brightness
In the setting interface, select “Brightness” and press the up/down button to adjust the brightness (1-100). 11.11 Auto power off
In the setting interface, select “Auto power off’ and press the up/down button to select 0ff/5min/10min/20min/30min/45min/60min/90min 11.12 Factory Reset
In the setting interface, select “Factory reset” and press the SET button. A box “Factory reset?” will pop up. Select “Yes”, the device will automatically shut down. After turning on again, the device will restore the factory settings.UNI-T UTi320E Handheld Thermal Imaging Camera - FIG
28 11.13 About
In the setting interface, select “About” and press the SET button to enter the submenu. The product information including product, Thermal Resolution, HWV, SYSV and SD can be viewed.

UNI-T UTi320E Handheld Thermal Imaging Camera - FIG
29Image Viewing

In the main interface, press the image viewing button to enter the “Gallery”. Press the up/down button to select All photos/other folders, and press the SET button to open the selected folder. Press the up/down/left/right button to select the image to be viewed, and press the SET button to view this image. Press the left/right button to switch between images. When viewing an image, press the SET button to open the submenu of this image. The functions in this submenu are: Info: create date, modified date, Emissivity, HVGA, Ambient Temp.,Relative Humidity, reflective distance, QR code.
Notes: The added notes will show in the photo message. Edit: markup, image, palette, measure, Isotherm. QR code: Users can add an existing OR code for image classification, or can delete the QR code of the current image or add a new QR code. Delete.
Note: In the redact Interface, after editing a photo, press the SET button and then the up button to select “restore’. Press the SET button again to restore the photo to its original state. Press the return button after editing, and a box “Exit?” will pop up. Select Exit to exit the editing Interface. Select Save and a box “Cover?’ will pop up. Select Cover, the original image will be changed and saved. Select New, the original image will not be changed and a new image will be saved.UNI-T UTi320E Handheld Thermal
Imaging Camera - FIG 30After adding the QR code, press the return button, and a prompt “Save and exit” will pop up. Choose Confirm to save the added QR coda. Choose Cancel to exit the QR code editing page without saving. The QR code added hem will not be saved to the existing OR code category. If users want to modify the existing QR code, they need to change it in the settings.

SD Card

This device supports Micro SD card to store images. To avoid affecting the operating speed of the device, please copy the backup data regularly and clean up the SD card in time. To avoid causing abnormal data on the SD card, do not insert or remove the SD card repeatedly. If the SD card is removed in the image viewing interface, a box “SD lost’ will pop up.

Maintenance

Use a wet cloth or weak soap solution to clean the outer shell of the device. Do not use abrasives, isopropyl alcohol or solvents to clean the outer shell, lens or window.

Safety Instructions

In order to ensure the accuracy, please read the instructions carefully. Please use this product in accordance with the manual; otherwise the free warranty will not be carried out if the product is damaged. Please do not use this device in flammable, explosive, steamy, humid or corrosive environments. Please do not continue to use the device when It is damaged, broken or corrected, so as to avoid incorrect test results. Please refer to the emissivity information to confirm the actual temperature, otherwise the measured temperature will be inaccurate.
Do not aim the lens at a strong or hot light source, such as the sun and other high-temperature objects, so as to avoid damage to the lens or thermal imaging detector.
Do not use the product in extremely hot, cold, dusty or high humidity environments. For detailed temperature and humidity requirements, please refer to the parameter table. The system supports USS cable to charge the machine, but in order to improve the charging efficiency, it is recommended to pull out the battery pack and charge the battery pack separately.

FCC Compliance statement

This device complies with Part 15 of the FCC Rules. Operation Is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Common Emissivity

Material Emissivity Material Emissivity
Wood 0.85 Black paper 0.86
Water 0.96 Polycarbonate 0.8
Brick 0.75 Concrete 0.97
Stainless steel 0.14 Copper oxide 0.78
Tape 0.96 Cast iron 81
Aluminum plate 0.09 Rust 0.8
Copper plate 0.06 Gypsum 0.75
Black aluminum 0.95 Paint 0.9
Human skin 0.98 Rubber 0.95
Asphalt 0.96 Soil 0.93
PVC 0.93

Contents of this manual are subject to change without prior notice.

UNI-TREND TECHNOLOGY (CHINA) CO.,LTD.
No.6, Gong Ye Bei 1st Road,
Songshan Lake National High-Tech Industrial
Development Zone, Dongguan City,
Guangdong Province, China

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals