- 1. PRELIMINARY EXAMINATION
- 2. SPECIFICATIONS
- 3. GENERAL DESCRIPTION & INTENDED USE
- 4. FUNCTIONAL DESCRIPTION & LCD DISPLAY
- 5. GENERAL OPERATIONS
- 6. SETUP
- 7. BLUETOOTH
- 8. HANNA LAB APPLICATION
- 9. CALIBRATION
- 10. CARE & MAINTENANCE
- 11. WARNING & ERROR MESSAGES
- 12. ABBREVIATIONS
- 13. ACCESSORIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HANNA instruments HI9810422 HALO2 Wireless pH Tester for Field Instruction Manual
Dear Customer,
Thank you for choosing a Hanna Instruments product. Please read this
instruction manual carefully before using this instrument. This manual will
provide you with the necessary information for correct use of this instrument,
as well as a precise idea of its versatility. If you need additional technical
information, do not hesitate to e-mail us at
tech@hannainst.com or view our contact list at
www.hannainst.com.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA.
1. PRELIMINARY EXAMINATION
Remove the tester and accessories from packaging and examine them carefully.
For further assistance, please contact your local Hanna Instruments office or
email us at tech@hannainst.com.
Each HI9810422 is supplied with a starter kit consisting of:
- pH 4.01 buffer solution, 20 mL sachet (2 pcs.)
- pH 7.01 buffer solution, 20 mL sachet (2 pcs.)
- Electrode cleaning solution, 20 mL sachet (2 pcs.)
- Electrode storage solution, 13 mL dropper bottle (1 pc.)
- 3V Lithium battery CR2032
- Instrument quality certificate and Instruction manual
Note: Save all packing material until you are sure that the tester works
correctly. Any damaged or defective item must be
returned in its original packing material with the supplied accessories.
2. SPECIFICATIONS
3. GENERAL DESCRIPTION & INTENDED USE
HI9810422 is a professional wireless pH tester, part of Hanna Instruments HALO2 family.
- The integrated Bluetooth module allows the tester to be connected to a compatible smart device with the Hanna Lab App.
- The tester has a compact, waterproof casing, and automatic pH calibration at up to three points, or four points when used with the Hanna Lab App.
- Automatically compensated temperature readings are displayed on a large LCD.
- Accurate and easy to use, the tester is ideal for field measurements due to its durability.
Operating Modes
The HI9810422 can be used as a stand-alone pH tester or connected to the Hanna Lab App. The Hanna Lab App turns a compatible smart device into a full- featured pH meter. Features include: electrode condition, GLP with time-stamp, live-readings, mV resolution, manual temperature compensation, stability criteria, calibration reminder, pH (mV) and temperature alarms, tester ID, and data sharing.
Probe Features
The HI9810422 features a PEI resin body that is easy to clean and resistant to
many aggressive chemicals.
The double junction design presents a silver-free electrolyte solution
interacting with the sample, making the electrode less susceptible to clogging
and guaranteeing a fast response and stable reading.
Built-in temperature sensor at the tip of the pH electrode allows for rapid
determination of the sample temperature and a high-accuracy temperature
reading.
4. FUNCTIONAL DESCRIPTION & LCD DISPLAY
Front & Back view
LCD display
- Calibration indicator
- Stability indicator
- Battery percentage indicator
- Battery icon
- Bluetooth icon
- Temperature compensation
- Second LCD line
- Temperature unit
- First LCD line
- Measurement unit
5. GENERAL OPERATIONS
Turning the Tester On & Off
- Turn the tester face down on a clean, dry surface. Rotate the battery cover on the back of the tester counter clockwise and set it aside. Remove the battery insulation film.
- Press the ON/OFF button to turn the tester on or off. Initialization screen displays all LCD segments, followed by the battery percentage. The tester enters measurement mode. Before the tester turns off, “OFF PWR” is displayed briefly.
- Press and hold the ON/OFF button to turn the tester off when connected to Bluetooth.
Battery Replacement
- Turn off the tester. Turn the tester face down and rotate the battery cover counter clockwise.
- Set the battery cover aside. Press the metallic pin to push old battery out.
- Place the new battery with positive (+) sign facing out.
- Reset the date and time in setup, or connect to the Hanna Lab App to update it automatically.
- Align the mark on the cover with the open lock icon ( ) on the case. Rotate the cover clockwise until the mark on the cover aligns with the closed lock icon ( ).
Note: Only use specified battery type. Dispose of old battery in accordance with local regulations.
6. SETUP
The Setup button is located inside the battery compartment. After Setup configuration, replace the cover. Setup Menu Navigation
- Press the Setup button to enter Setup mode and navigate menu items.
- To exit Setup mode, press the Setup button after “SEt TIME” option is displayed.
- Press the ON/OFF button to configure menu item options.
Temperature Unit
Option: °C or °F Press ON/OFF button to select desired temperature unit.
Auto-Off Interval
Option: 8, 60 min., or “—-” (disabled) Press ON/OFF button to select desired interval. To save battery life, after the selected auto-off interval has elapsed, the tester will automatically turn off.
Calibration Points
Option: 2P or 3P Press ON/OFF button to select between up to two- or up to three-point calibration.
Buffer Set
Option: 7.01 pH (Hanna) or 6.86 pH (NIST) Press ON/OFF button to select the calibration buffer set (Hanna or NIST).
pH Resolution
Option: 0.01 pH or 0.1 pH Press the ON/OFF button to select resolution.
Bluetooth Wireless Mode
Option: On, PAIr, or OFF
Press ON/OFF button to select Bluetooth option at start-up.
Bluetooth Pairing
Option: dEL PAIr Press ON/OFF button to delete saved paired device.
Date & Time
Option: SEt TIME Press ON/OFF button to set the date and time. Option: YEAR, MO, DAY, HOUR, and MIN Use the Setup button to select the option and press the ON/OFF button to change the selected option.
7. BLUETOOTH
With “PAIr BLU” or “On BLU” selected in Setup, the Bluetooth icon (&) will blink for up to 45 seconds, indicating the tester is in discoverable mode. Once connected, the icon will stop blinking. If not connected, the icon is not displayed.
- Select “On BLU”, to enable Bluetooth without bonding.
- Select “PAIr BLU”, to enable Bluetooth with bonding. A 6-digit bonding pin is displayed the first time the tester and smart device are paired. Once the devices are paired, the bonding pin is not required when reconnected.
- Select “OFF BLU”, to disable Bluetooth.
- Select “dEL PAIR”, to delete all paired devices. If PAIr BLU is enabled, a bonding pin will need to be re-entered.
8. HANNA LAB APPLICATION
- The Hanna Lab App is available on the App Store® and on Google Play.1
- Consult the Help section of the application for information on calibration, measurement, data logging, and sharing.
- When the tester is in discoverable mode, it will appear in the list of “Available Devices”.
- Within the application, tap “Connect” to pair the tester with the device. All readings are transmitted directly to the application.
Tag a Measurement
Once connected to the application, the ON/OFF button can be pressed to tag the current reading.
- Press the ON/OFF button from measurement mode. The display shows “SEt TAG”, followed by “- TAG”.
- The reading on the application will flash green and the note icon ( ) will be displayed. Tap the note icon ( ) to add an annotation.
9. CALIBRATION
Preparation & Guidelines
- Unscrew the top collar to vent the cap before removing the probe from the plastic storage tube. Save cap and collar for probe storage.
- Rinse off any storage solution or salts that may be on the body.
- Verify there is solution inside the pH bulb by shaking the probe down to restore continuity as the solution may have moved up the stem during shipping.
- For best results, use a rinse beaker and a separate calibration beaker for each buffer. Discard rinsing buffers after use.
Procedure
For most applications it is recommended to start with pH 7.01 buffer (or pH
6.86). To restore factory defaults, press and hold the ON/OFF button. “CAL
CLR” is displayed.
Note: It is recommended to calibrate the electrode with buffers at the
temperature it will be used at.
App Store is a trademark of Apple, Inc.
Google Play and the Google Play logo are trademarks of Google LLC.
Stand-Alone Tester (Up to Three-Point Calibration)
With Hanna Lab App (Up to Four-Point Calibration)
Connect the tester to the Hanna Lab App and follow the calibration procedure. See the App Help section for the calibration procedure.
10. CARE & MAINTENANCE
- Never immerse the tester over the maximum immersion level.
- Fresh buffers should be used for each calibration. Once the sachets are opened the buffer value can change over time.
- If the electrode is slow or sluggish, soak it in cleaning solution for 20 minutes. Rinse with water and hydrate the electrode in storage solution for a minimum of 30 minutes before calibrating.
- If measurements are taken successively, rinse the probe thoroughly in distilled or deionized water to eliminate cross-contamination between measurements.
Storage
To ensure a quick response, the glass tip and junction should be kept hydrated.
-
When not in use, add a few drops of storage solution to storage cap. If storage solution is not available, pH 4.01 or pH 7.01 buffer can be used.
Note: Do not store the electrode in distilled or deionized water. -
Place the probe tip into the cap and gently tighten the collar.
11. WARNING & ERROR MESSAGES
12. ABBREVIATIONS
ATC Automatic Temperature Compensation
GLP Good Laboratory Practice
MTC Manual Temperature Compensation
NIST National Institute of Standards and Technology
13. ACCESSORIES
RECOMMENDATIONS FOR USERS
Before using this product, make sure it is entirely suitable for your specific application and for the environment in which it is used. Any variation introduced by the user to the supplied equipment may degrade the tester’s performance. For your and the tester’s safety do not use or store it in hazardous environments.
WARRANTY
HI9810422 is warranted for a period of one year against defects in workmanship
and materials when used for its intended purpose and maintained according to
instructions. This warranty is limited to repair or replacement free of
charge. Damage due to accidents, misuse, tampering, or lack of prescribed
maintenance is not covered. If service is required, contact your local Hanna
Instruments office. If under warranty, report the model number, date of
purchase, serial number, and the nature of the problem. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the
tester is to be returned to Hanna Instruments, first obtain a Returned Goods
Authorization (RGA) number from the Technical Service department and then send
it with shipping costs prepaid. When shipping any product, make sure it is
shipped back in compliance with shipping regulations, thoroughly cleaned and
free of any chemicals, and is properly packaged for complete protection.
MAN9810422 10/21
Hanna Instruments reserves the right to modify the design, construction or appearance of its products without advance notice.
CERTIFICATION
All Hanna Instruments conform to the CE European Directives. Disposal of Electrical and Electronic Equipment. The product should not be treated as household waste. Instead, hand it over to the appropriate collection point for the recycling of electrical and electronic equipment, which will conserve natural resources. Disposal of waste batteries. This product contains batteries, do not dispose of them with other household waste. Hand them over to the appropriate collection point for recycling. Ensuring proper product and battery disposal prevents potential negative consequences for the environment and human health. For more information, contact your city, your local household waste disposal service, or the place of purchase.
Regulatory Notices for stand-alone, Bluetooth, low-energy modules
All modules have identical operation. All references to US FCC Rules and
Canadian RSS standards on device classification and operation, listed here
under BMD-300 Module, apply to all models noted here. Remove the battery cover
to check the installed module.
BMD-300 Module
United States (FCC) FCC ID: 2AA9B04 This device complies with FCC Rules, Part
15, Subpart C “Intentional Radiators” and Subpart B, Chapter §15.105. This
equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case, users
are required to correct the interference at their own expense.
Canada (ISED) IC: 12208A-04 This device complies with Industry
Canada license exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
World Headquarters
Hanna Instruments Inc. Highland Industrial Park 584 Park East Drive
Woonsocket, RI 02895 USA www.hannainst.com
MAN9810422
Printed in ROMANIA