Tips for First-Time Use
- Allow the unit to sit upright for at least 3-4 hours before powering on. Shipping carriers may set the unit on its side, which causes the refrigerant to pool in certain areas Standing the unit upright for 3-4 hours allows the refrigerant to move freely within the coils.
- Some parts with sharp edges may cause injury, so gloves are highly recommended for unpacking and installing.
- Run the unit continuously for 24 hours after letting the unit stand upright for 3-4 hours. This will give even the smallest and technically unavoidable air bubbles in the coolant circuit that may have been created during transport from our factory to your doorstep the opportunity to migrate to the top of the cooling circuit.
- f you have any difficulties during installation, please contact Customer Support Team via support@turbra.com for help.
- If you have any problems with your product, please send us an email before submitting a return request, as there might be a simple solution for your issue.
SAFETY INFORMATION
Please read all instructions before use and save this user manual for future reference. A digital version can be obtained from Customer Support.
Your safety and the safety of others are very important to us. We have provided many important safety messages throughout this manual and on the appliance itself. Always read and follow all posted safety messages.
To reduce the risk of fire, electric shock, injury, or death to persons using or near this appliance, please follow some basic safety precautions. These precautions include, but are not limited to, the following:
Installation and Setup
- This appliance is not intended for use by any persons (including children) with reduced or restricted physical, mental, or sensory capabilities, or lack of experience and knowledge, unless under the direct supervision of a person responsible for their safety.
- Please keep plastic bags and sheets out of the reach of children as they might be mistakenly used for play. Packaging materials can become airtight chambers and may pose a risk of suffocation if not disposed of properly.
- When installing or moving the appliance, be careful not to pinch, crush, or damage the power cord.
- Install the appliance on a sturdy, level floor capable of supporting up to 110Ibs(50kg). Installation on a weak or un-level floor can result in the risk of property damage and personal injury.
- Never attempt to operate this appliance if it visibly damaged, malfunctioning, disassembled or has missing or broken parts. This includes exposed wiring on a damaged cord or electrical plugin. All repairs and servicing must be performed by qualified service personnel. Use only authorized TURBRO factory OEM parts.
- Do not use heating equipment near the appliance.
- In the event of a gas leak (propane gas, LP gas, etc.) do not operate this or any other appliance. Open a window or door to ventilate the area immediately.
- Only use the appliance in an upright position. Make sure the angle of inclination <10°. Always place the appliance on a stable, flat, level surface to prevent the air conditioner from overturning.
Electrical Safety Warning
WARNING
Electrical Connections
Before plugging the appliance into the mains socket, check that:
- The mains power supply corresponds to the value indicated on the rating plate on the back of the appliance.
- The power socket and electrical circuit are adequate for the appliance, and have appropriate fuse protection in the fuse box of the building.
- The mains socket matches the plug. If this is not the case, have the plug replaced.
- The mains socket is adequately earthed. Failure to follow these important safety instructions absolves the manufacturer of all liability.
Important information for correct disposal of the product in accordance with
EC Directive
2012/19/EU.
At the end of its working life, the product must not be disposed of as urban
waste. It must be taken to a special local authority differentiated waste
collection center or to a dealer providing this service. Disposing of a
household appliance separately avoids possible negative consequences for the
environment and health deriving from inappropriate disposal and enables the
constituent materials to be recovered to obtain significant savings in energy
and resources. As a reminder of the need to dispose of household appliances
separately, the product is marked with a crossed-out wheeled dustbin.
- Always use the switch on the control panel or remote control to turn the unit off, and do not start or stop operation by plugging in or unplugging the power cord. It can result in the risk of electric shock.
- Do not touch the buttons on the control panel with your wet and damp fingers.
- Do not use the unit in the presence of inflammable substance or va pour such as alcohol, insecticides, gasoline, etc.
- If the appliance is making unusual sounds or is emitting smoke or an unusual odor, unplug it immediately.
- Always grasp the plug when plugging in or unplugging the appliance. Never unplug by pulling on the cord. It can result in the risk of electrical shock and damage.
According to the IEC standard
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Activate
- The appliance shall be installed in accordance with national wiring regulations.
IMPORTANT – Grounding Method
- This product is equipped with a power supply cord that has a three pronged grounded plug. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances.
- If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the
-
-
-
-
-
-
-
-
-
- customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances.
-
-
-
-
-
-
-
-
- The third ground prong should not, under any circumstances, be cut or removed. Never use the cord, the plug or the appliance when they show any sign of damage.
- Do not use your appliance with an extension cord unless it has been checked and tested by a qualified electrical supplier.
- Improper connection of the grounding plug can result in risk of fire, electric shock and/or injury to persons associated with the appliance.
- Check with a qualified service representative if in doubt that the appliance is properly grounded.
PARTS DESCRIPTION
- control Panel
- Horizontal Airflow Louver
- Handle both sides)
- Casters
- Plug Storage Socket
- Middle Condenser Drain
- Condenser Drain
- Air Intake Grille
- Air Outlet Grille
- Air Intake grille
- Power Cord
INSTALLATION INSTRUCTIONS
Installation Location
- The air conditioner should be placed on a firm floor to minimize noise and vibration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit.
- The unit must be installed near a properly rated grounded socket.
- Allow at least 19.7 inches / 50 cm of space away from the wall with the window for efficient working.
- Never place any obstacles around the air inlet or outlet of the unit.
- The hose can be compressed or extended moderately, but it is desirable to keep the length to a minimum. Also make sure the hose does not have any sharp bends or sags.
Tool Suggested
Phillips head screwdriver| Flat head
screwdriver| Saw
---|---|---
Tape measure| Scissors| Pencil
The window panel kit has been designed to fit most standard windows that open vertically or horizontally; however, it may be necessary for you to improvise/modify some aspect of the installation procedures for certain types of window.
The included window panels don’t fit for tilting or casement windows. You need to purchase a window seal pack (it’s not included). Please contact TURBRO Service team (support@turbro.com), if you need any help with the installation. Minimum and maximum window openings: 9 – 59 Inches
NOTE:
If the width of your window is smaller than 20.5 inches, please remove the
adjusting panel from the window panel and then cut the window panel to make
the width of the window panel the same width as your window.
Installing Double-Hung Sash / Sliding Casement Windows
A. Required Parts:
- Foam Seal
- Window Panel with Hole
- Adjustment Panel without Hole
- Extension Panel
- Metal Locking Screw
B. Assembly:
a. Cut the foam seal to the proper length and attach it to the window
sash.
b. Slide Adjustment Panel into the Window Panel with Hole and Extension
Panel.
NOTE:
A plastic locking pin is holding the window panel kit together during
shipment. Prior to installation, remove the plastic locking pins.
c. Place the assembled window panels on the window sash and adjust until
it fully covers the width of your window.
NOTE: If the width of your window is smaller than 20.5 inches, please
remove the adjusting panel from the window panel and then cut the window panel
to make the width of the window panel the same width as your window.
d. Use the provided metal locking screws to secure the window panel kit.
e. Close the window securely against the assembled window panel kit.
f. Cut the foam seal to an appropriate length and seal the open gap between the top window sash and outer window sash.
Installing Exhaust Hose
COOL & DEHUMIDIFY MODE: Air exhaust hose should be connected to the portable air conditioner.
FAN MODE: Air exhaust hose should be disconnected from the portable air conditioner.
A. Required Parts:
- Hose Inlet
- Exhaust Hose
- Hose Outlet
B. Assembly:
a. Align both the arrows of the Hose Inlet connector and the Exhaust
Hose, then rotate the Hose Inlet clockwise or counter-clockwise to lock into
place. (see Fig. 1)
b. Use the same way to attach the Hose Outlet and the Exhaust Hose.
c. Fig.2 is the assembled exhaust hose.
d. Install the Hose Inlet into the groove at the back of the unit and
extend the exhaust hose. (see Fig.3)
e. Affix the Hose Outlet to the window panel. **(see Fig.4)
**
NOTE: The exhaust hose can be compressed or extended moderately, but it is desirable to keep the-to a minimum. Also make sure that the hose does not have any sharp bends.
OPERATING INSTRUCTIONS
Control Panel
- Timer Button
- Fan Speed Button
- Increase Button
- Decrease Button
- Mode Button
- ON/OFF Button
The Control Panel enables you to manage all the main functions of the appliance, but to fully exploit its potential, you must use the remote control.
TURNING THE APPLIANCE ON
- Plug into the mains socket, then the appliance is in standby.
- Press the ON/OFF Button i) then the display screen will light up.
NOTE: Never turn the air conditioner off by unplugging from the mains. Always press the ON/OFF Button O : then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation.
Operating mode selection
Pressing Mode Button OD will cycle through the following modes, as shown
below:
COOL MODE
Ideal for hot muggy weather when you need to cooling and dehumidify the room.
- Press the Mode Button 4 until the ‘Cool’ indicator lights up. Also, the screen will appear 24.
- Press the sor % button to select your desired temperature 18°C -32°C (64°F -90°F).
- Press the Fan Button S to select the fan speed. The indicator light shows the selected speed.
High | To reach the desired temperature as rapidly as possible. |
---|---|
Low | To operate under low noise. |
DRY MODE
Ideal to reduce room humidity (spring and autumn, rainy periods or in damp rooms, etc)
NOTE: Before using the dry mode, please make sure the air exhaust hose attached to the appliance to allow the moisture to be discharged externally and the drain hose attached to avoid any leaking. (The Water Drainage Methods will be mentioned in the following parts)
- Press the Mode Button 4@ until the ‘Dry’ indicator lights up. Also, the screen will appear
- In this mode, the unit will run at the low speed and the fan speed cannot be adjusted.
FAN MODE
When using this mode, the unit doesn’t need to be attached with the air exhaust hose.
- Press the Mode Button 4 until the ‘Fan’ indicator lights up.
- Press the Fan Button $§ to select the fan speed.
FAN SPEED | SYMBOL |
---|---|
High | |
Low |
TIMER FUNTION
This timer can be used to delay the unit start up or shutdown, this avoids wasting electricity by optimizing operating periods.
Programming start up
- Press the ON/OFF Button () to turn on the unit and choose your desired mode, for example ‘cooling, 68 °F and high fan speed’. Then press the ON/OFF Button (d) again to turn off the unit.
- Press the Timer Button @ , the timer indicator and the screen digital will flash. Use the wa and @ keys to select the desired switch-on delay (displayed in hours) and wait for about 5 seconds. When the timer is active, the ‘Timer’ indicator will keep stay on and the screen will display ~ =
- Press the Timer Button ® again, the timer will be canceled, and the ‘Timer’ indicator will disappear.
Programming shut down
- With the unit on, please press the Timer Button (2) , the timer indicator and the screen digital will flash. Choose the required delayed shut-down time and wait for about 5 seconds. When the timer is active, the ‘Timer’ indicator will keep stay on and the screen will display ~ ~.
- Press the Timer Button (} again, the timer will be canceled, and the ‘Timer’ indicator will disappear.
TEMPERATURE SCALE CONVERSION
The device is capable of displaying temperatures in both degrees Celsius as well as degrees Fahrenheit.
With the unit on, press and hold the &% and %# button together for 3 seconds at the same time, then you can switch the unit of temperature.
For example:
- In Celsius degree, the digital displays like fig].
- In Fahrenheit degree, the digital displays like fig2.
**Operation from the Remote Control
**
NOTE: This is a universal remote control for a variety of models. If your model does not have a function listed on the remote control, there will be no changes in the operation of your unit.
Using the remote
The maximum range of the remote control is 23 feet / 7 meters away from the appliance (without obstacles between the remote control and the receiver).
The remote control must be handled with extreme care. Do not drop it or expose
it to direct sunlight or sources of heat. If the remote control do not work,
please try to take out the battery, and put it back.
Inserting or replacing the batteries
- Remove the cover on the rear of the remote control
- Insert two “AAA” 1.5V batteries in the correct position (see instructions inside the battery compartment)
NOTE:
- If the remote control unit is replaced or disposed of, the batteries must be removed and discarded in accordance with current legislation as they are harmful to the environment.
- Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries.
- Do not dispose of batteries in fire. Batteries may explode or leak
- Remove the batteries if the remote control won’t be used for a long time.
The following functions only can be active by using the remote: