CONNECTION DETAILS:

INDITECH-PARALLEL-COP-170x900-DOT TOUCH-BLACK FACIA-12V G+4
-01

Note: For connection details refer below page.

DISPLAY AND SWITCH CONNECTION DETAILS:

Sr. No.| Wire Color| Connection Details (J1) (12 Pin

Relimate Connector)

---|---|---
1| BLACK| 24V
2| BROWN| GND
3| RED| A
4| ORANGE| B
5| YELLOW| C
6| GREEN| D
7| BLUE| E
8| VIOLET| F
9| GRAY| G
10| WHITE| UP (ARROW)
11| BLACK| DOWN (ARROW)
12| BROWN| NC (No Connection)

Sr. No. Wire Color Connection Details (J3) (4 Pin Relimate Connector)
1 BLACK IN1 (To Display digits 10 to 19)
2 BROWN IN2 (To Display digits 20 to 23)
3 RED OL (For Overload)
4 ORANGE M (For Maintenance)

Sr. No.| Wire Color| Connection Details Touch Button (4 Pin Relimate Connector)
---|---|---
1| BLACK| L+                            12V
2| BROWN| L-                           G, 1, 2, 3, 4

SW+

3| RED|
4| ORANGE| SW-                         GND

Connection Details:INDITECH-PARALLEL-COP-170x900-DOT TOUCH-BLACK FACIA-
12V G+4 -02 Mounting Details: INDITECH-PARALLEL-COP-170x900-DOT TOUCH-BLACK FACIA-12V G+4
-03

Features:

  • We can provide logo as per customer demand.
  • Available for G+4 floors.
  • Facia- Black color
  • Display Type- Dot Matrix
  • Buttons – TOUCH
  • Reliable
  • Easy to use
  • Durable
  • Reliable

Specifications

  • Input Supply- 24V
  • COP size-170×900
  • Thickness-18MM
  • Mount Type- Wall mount

Calibration process:

  • Give segment which is set to for floor.
  • Press S1 and S2 both keys then display shows ‘- – ‘then release both the keys.
  • When’- -‘ symbol stop blinking, press S1 and S2 for increment & decrement.
  • After pressing S1 & S2 keys for increment and decrement it shows digits Which we have to set.
  • After showing display which is we have to set, then release the key after sometime.
  • Display will blink and shows – – means calibration is saved & it will display Saved floor.
  • Repeat same procedure for next floor calibration.

Calibration reset process:

  • If we want to display only normal 7 segment then no need to calibrate.
  • Short the pin No. 1 & 2 of J4 berg strip for 10 second.
  • After completion of 10 second display is shows FR it means process is Completed and program is in normal 7 segment mode.
  • Give 7 segments to the connector J1, display will show floor.