Inditech TFT 170X900 Parallel COP Touch User Manual

June 9, 2024
Inditech

Inditech TFT 170X900 Parallel COP Touch User Manual

Inditech TFT 170X900 Parallel COP Touch User Manual

1. TYPE OF MODEL:

  • PARALLEL COP TOUCH TFT 170X900- 12/24V
  • PARALLEL COP TOUCH TFT 200X1000- 12/24V

Inditech TFT 170X900 Parallel COP Touch User Manual - Types of
model

2. PRODUCT DESCRIPTION:

This product is Inditch’ s own design based upon high precision touch technology. It offers smooth operations to the user with best touch experience along with beautiful and attractive looks and aesthetics. It has Slim design with SS frame and stunning shiny acrylic fascia.

Note: This document is common for various models. Kindly verify the model you procured. Read the document as per the model you procured.

3. FEATURES/ SPECIFICATIONS:

  • Mount Type- Wall Mount
  • Fascia- Black/White Color
  • Input Supply- 12/24V
  • Parallel Interface
  • Support- Up to G+7 Floors
  • Display Type- 5”/ 7” TFT
  • Buttons – Capacitive Touch
  • Size (WHT)- 170x900x18MM / 200x1000x18MM
  • Reliable
  • Easy to use
  • Durable

4. INSTALLATION STEPS:

Note: Installation and Commissioning of the COP is to be done by Authorized, Trained technician of Elevator Company.

Following are the steps to be taken for the installation of this panel.

  1. Remove the back plate of COP
  2. Mount the back plate of COP on the wall as per POINT NO. 5 Mounting details below.
  3. Do the connections as per POINT NO.6 Connection Diagram below.
  4. Fix the COP on back plate with CSK M3X5MM screw.
  5. Do the calibration as per POINT NO.7 Calibration process below.

5. MOUNTING DETAILS:

Inditech TFT 170X900 Parallel COP Touch User Manual - MOUNTING
DETAILS

6. CONNECTION DIAGRAM WITH DETAILS:

Inditech TFT 170X900 Parallel COP Touch User Manual - CONNECTION DIAGRAM
WITH DETAILS

Note: For connection details refer below page .

A DISPLAY AND SWITCH CONNECTION DETAILS:

Inditech TFT 170X900 Parallel COP Touch User Manual - DISPLAY AND SWITCH
CONNECTION DETAILS

B SPECIAL INPUTS CONNECTION DETAILS:

Inditech TFT 170X900 Parallel COP Touch User Manual - SPECIAL INPUTS
CONNECTION DETAILS

B 4-PIN RELIMATE ENCODER CONNECTION:

Inditech TFT 170X900 Parallel COP Touch User Manual - 4-PIN RELIMATE ENCODER
CONNECTION

7. CALIBRATION PROCESS:

  • CALIBRATION SET PROCESS:
    • Give segment which is set to for floor.
    • Press S1 and S2 both keys then display shows ‘- – ‘then release both the keys.
    • When’- -‘ symbol stop blinking, press S1 and S2 for increment & decrement.
    • After pressing S1 & S2 keys for increment and decrement it shows digits Which we have to set.
    • After showing display which is we have to set, then release the key after sometime.
    • Display will blink and shows – – means calibration is saved & it will display Saved floor.
    • Repeat same procedure for next floor calibration.
  • CALIBRATION RESET PROCESS:
    • If we want to display only normal 7 segment, then no need to calibrate.
    • Short the pin No. 1 & 2 of J4 berg strip for 10 second.
    • After completion of 10 second display is shows ‘FR’ it means process is Completed and program is in normal 7 segment mode.
    • Give 7 segments to the connector J1, display will show floor.