ACT AC2125 USB Charger 2 Port 30W User Manual
- June 9, 2024
- ACT
Table of Contents
ACT AC2125 USB Charger 2 Port 30W
Product Information
The product is compliant with the new standard for ERP certification (EU) 2019/1782 (sometimes referred to as Eco Design) for external power issued by the European Union, repealing Commission Regulation (EC) No 278/2009 from 1 April 2020.
- Value and precision: AC2125
- Input: 100-240V, 50/60 Hz
- Output:
- USB1: 5.0V-9.0V-12.0V, 3.0A-2.0A-1.5A
- USB2: 5.0V, 2.4A
- Total output: 30.0W
- Efficiency: 82.7%
- Standby power consumption: 0.30W
Product Usage Instructions
To use the product, follow the steps below:
- Plug the input of the power adapter into a power outlet with the voltage range of 100-240V and frequency of either 50Hz or 60Hz.
- Connect USB devices to the respective ports on the power adapter.
- The USB1 port has three voltage options, make sure to select the appropriate voltage for your device by switching the button next to the port.
- The USB1 port also has three current options, make sure to select the appropriate current for your device. The USB2 port has a fixed current of 2.4A.
- The total combined output of the power adapter is 30.0W.
THE PRODUCT MENTIONED BELOW IS COMPLIANT WITH THE NEW STANDARD FOR ERP CERTIFICATION (EU) 2019/1782 (SOMETIMES REFERRED TO AS ECO DESIGN) OF EXTERNAL POWER ISSUED BY THE EUROPEAN UNION, REPEALING COMMISSION REGULATION(EC) NO 278/2009 FROM 1 APRIL 2020.
SIGNED FOR AND ON BEHALF OF
Manufacturer’s name| ACT
Koolhovenstraat 1E 3772 MT Barneveld
The Netherlands
---|---
Commercial registration| K.v.K. 09068548
Place and date of issue: Barneveld, 10 January 2022
| ****
Signature:
| ****
Name, function:
Marc Swolfs, Managing director
COMPLETE GUIDELINES
- Input voltage: Supply voltage. X. Needs only for the decimal point as unit V
- Input frequency: Power supply frequency. X. Needs only for the decimal point as unit Hz
- Max output voltage: max output voltage. X,X. One decimal place as unit V
- Max output current: max output current. X,X. One decimal place as unit A
- Average active efficiency: Average active efficiency. X,X. One decimal place as unit %.
Efficiency at low load (10%). Efficiency at low load (10 %) X,X. One decimal place as unit %. No load power consumption. Energy consumption in no-load condition. X,XX One decimal place as unit %
FOR PUBLICATION CONVERT RED TEXT TO BLACK!!!!!!
ACT, Koolhovenstraat 1E, 3772 MT Barneveld, The Netherlands
www.act-connectivity.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>