EVERISE WSX-E5 Plastic Scoop Stretcher User Manual

June 9, 2024
EVERISE

EVERISE WSX-E5 Plastic Scoop Stretcher

EVERISE-WSX-E5-Plastic-Scoop-Stretcher-PRODUCT

Description

  • The WSX-E5 is an emergency patient –handling scoop stretcher. The stretcher is designed to aid the moving of a patient when space is limited or when the patient requires moving with the minimum amount of movement to the body.
  • The stretcher should be operated in accordance to the protocols of the country where it is used.
  • The stretcher is for professional use after adequate training has been taken and should be lifted with a minimum of 2 operators.
  • The stretcher is constructed in two halves which uncouple, after uncoupling slide the two parts under the patient then re-connect ready for lifting.
  • The length of the stretcher can be adjusted according to the length of the patient’s body.
  • The foot-end is designed as a narrow-frame structure for the stretcher’s use in confined places.
  • The stretcher is supplied with a set of three patient restraint straps
  • The length can be adjusted in 4 positions
  • The stretcher is Radiolucent, it is available in X-ray &CT-scan procedure

Storing the Stretcher

  • The stretcher can be folded for storage, unlock the locking pins on both sides of the stretcher. Fully extend the foot section by pulling it out until the hinges are visible. Lift the foot section and fold it over.

Parameters

  • Load weight: 159kg
  • Net weight: 7 .5 kg
  • Folding size: 118 0mm × 4 50 mm × 85 mm
  • Unfolded size: 16 40 mm × 4 45 mm × 6 5 mm

Diagram

Scoop stretcher profile

  • ,1 Short hand rail
  • ,2 Companding bar
  • ,3 Block protection pipe sleeve
  • ,4 Stock locater block
  • ,5 Stock locater insert
  • ,6 Joint elements

Instructions

  1. Separation
    Rotary lever to flip the level of short-form; the telescopic rod into the retaining plate and pipe kit, adjust to the right length ,press the stock locater block, put the stock locater pip insert the stock hole, press the join elements at the ends of the stretcher, then the stretcher can be separate to left & right part. Move the patient to the hip underground.
    Step:

    • Reverse the short handrailing
    • Forward the compading bar
    • Press the stock locater block
    • Press the join element, separate the stretcherEVERISE-WSX-E5-Plastic-Scoop-Stretcher-FIG-2
  2. Folding operation Put the stock locater block upward;push the companding bar to the longest;long folding(also fold after separate to left and right part)enable to make it meet the need of packing.
    Step:

    • Upward the stock locater block
    • Push the companding to outward to the longest
    • Long foldingEVERISE-WSX-E5-Plastic-Scoop-Stretcher-FIG-3

Attention: Before lifting the stretcher fasten the restrain

Maintaining

Filling the lube oil in the place of fold, elements regularly, to make sure it can always fold smoothly.

Attention: Prohibit regulation and rough operation, unable to use it over the load capacity, in case of the damage under the improper use.
We declare that the device complies with MDR 745/2017 “Medical Devices It is necessary to report any serious accident occurring in relation to the DM to the Manufacturer and the competent authorities

  • Add: 1001Chengyang Road, Jiangyin City, Jiangsu Province,China.
  • Tel: 86-510-86900900
  • Fax: 86-510-86900111
  • Code: 214423
  • Website : www.EVERISEmedical.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals