SIEMENS FDOOT441 Series Intelligent Smoke Detector Owner’s Manual
- June 9, 2024
- SIEMENS
Table of Contents
- SIEMENS FDOOT441 Series Intelligent Smoke Detector
- Desigo® Fire Safety:
- From detectors to panels – complete protection
- Intelligent technology for enhanced detection
- S-LINE – setting new standards with ASAtechnologyTM
- C-LINE – for standard applications
- Detectors at a glance
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SIEMENS FDOOT441 Series Intelligent Smoke Detector
Desigo® Fire Safety:
innovation based on trusted experience from Siemens
Desigo® Fire Safety is a comprehensive fire safety system for fast, reliable
fire detection, as well as alarm signaling and control. It is designed to
protect lives and assets and to prevent production losses, thereby
safeguarding your company’s buildings and survival. Desigo Fire Safety not
only defines the technological state of the art, but also offers a high level
of flexibility and scalability, as well as compatibility with existing and
future products.
From detectors to panels – complete protection
A complete fire protection solution from one source
Safety is a deep-rooted, fundamental need. That’s why solutions that reliably
protect people, assets, and processes against fire, smoke, and carbon monoxide
play such a crucial role. Desigo Fire Safety comprises everything needed for
comprehensive fire protection:
- Fire detectors with excellent reliability prevent false alarms and meet the requirements of the fire safety and carbon monoxide codes NFPA 72 and NFPA 720.
- Control panels, fire terminals, remote terminals, and displays provide full system view and are easy to operate, even in the case of an event.
- Complete range of peripherals, ranging from notification devices to manual alarm stations.
Safe, precise, and reliable
Reliable detection, fast notification, quick response – Desigo Fire Safety
sets the standard in all three areas, including:
- Redundant sensors that increase the reliability of the fire detectors.
- Forward and backward light scattering technology that ensures enhanced sensitivity to actual fires and practically eliminates false alarms.
- All detectors with ASAtechnology™ come with a No False Alarm Guarantee.
A special carbon monoxide (CO) detector detects CO, whether generated by or independent from fire. Fast, fault-tolerant communication between FDnet devices and the control panels increases system reliability. The control panels allow simple, intuitive operation, plain text displays, and clear instructions, which allow security personnel to focus on the event.
Meeting every need from “standard” to “special”
Desigo Fire Safety is a homogeneous family of fire detectors and control
panels whose models are all compatible. From standard to special situations,
it’s easy to realize the benefits of this comprehensive system:
ASAtechnology™ detectors from the S-LINE range are excellent for sophisticated
applications with deceptive phenomena. They offer more than
20 detection profiles for different environments including data centers, power
generation, utility rooms, warehouses, manufacturing, parking garages, and
ducts. This means you can cover all applications with one detector.
The C-LINE detector portfolio is a cost-effective option for standard
applications.
The different control panels increase flexibility in system planning and keep
your system scalable for the future.
Highlights
- Quick, reliable detection of fire, smoke, and carbon monoxide
- Simple panel operation with easy access to all functions
- Systems custom built according to your safety and budget needs
- Reliable detection confirmed by the S-LINE detector’s No False Alarm Guarantee
Siemens owns one of the largest fire test laboratories in the world. We conduct live fire behavior tests in eight test labs. Our database contains more than 5,000 tests. We factor all of this information into the development of our Desigo fire detectors.
Intelligent technology for enhanced detection
One family to cover virtually any application
Desigo fire detectors answer virtually any application need, from standard to
sophis-ticated and from clean to dirty. The C-LINE detectors are an
economical, reliable solu-tion for standard applications. The S-LINE detectors
are the best choice for more demanding applications with deceptive phenomena,
when extremely fast response time and the highest level of prevention of false
alarms is needed. Detectors from both lines can be used together in a single
network. In short, Desigo allows you to manage diverse detection requirements
with one detector family and one system.
Unique sensor technology
In multiple environmental conditions, Desigo detectors reliably detect any
sign of fire as early as possible. Their unique sensor system utilizes state-
of-the-art forward and backward light scattering technology. This technology
provides advanced optical analysis of light and dark smoke particles. As a
result, it improves the detection capabilities of the detectors and makes them
virtually immune to false alarms. Desigo detectors comply with NFPA 76
(Telecommunication Standard) and are classified as Very Early Warning Fire
Detectors (VEWFD). This means that they are extremely sensitive and provide
very early detection.
A smart choice for the environment
The detectors are RoHS compliant, meeting the standards regarding the
Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment. S-LINE detectors also provide enhanced detection
capability equivalent to ioniza-tion detectors due to their forward and
backward light scattering technology. This makes them a great “green”
solution.
Redundant sensors increase reliability
S-LINE detectors have two thermal and two optical sensors. This redundancy
heightens their immunity to deceptive phenomena and increases their detection
capability and reliability. Should one sensor fail, the detec- tors will still
provide fail-safe operation.
Highlights
-
One detector portfolio to cover most application areas, from clean to dirty
-
Reliable detection that eliminates false alarms due to unique forward and backward light scattering technology
Compliant with NFPA 76 (Telecommunication Standard) and classified as a VEWFD -
RoHS compliant, with detection capability equivalent to ionization detectors due to forward and backward light scattering technology
-
Increased reliability and fail-safe operation thanks to redundant sensors
Legend
- Two IR light sources
- The rays of the two IR light sources are scattered by smoke particles in the sampling chamber and strike the light receiver.
- IR receiver: the special position of the two IR light sources helps to distinguish between light and dark smoke particles due to forward and backward light dispersion.
- The patented labyrinth absorbs light emitted by the light sources, thus preventing random reflection. It also captures small fibers and dust particles so that they do not enter the sampling chamber.
- Redundant temperature sensors (two) measure the temperature.
- The monitored CO sensor measures the CO concentration.
S-LINE – setting new standards with ASAtechnologyTM
U nsurpassed reliability
Preventing downtime and costs caused by false alarms are central
considerations for any company. ASAtechnology™
(Advanced Signal Analysis) offers extreme detection reliability with the
immunity to deceptive phenomena. Therefore, we offer a No False Alarm
Guarantee with this detector.
Sophisticated applications require exceptional technology
S-LINE detectors feature our unique ASAtechnology™. This makes them highly
reliable in preventing false alarms caused by deceptive on-site phenomena,
such as machine exhaust gases, dust, or steam. This provides excellent
protection and extremely reliable detection in critical applications, ranging
from very clean environments like data centers and tele-communications centers
to dirty industrial applications like warehouse facilities.
Highest life safety
The multi-criteria fire/CO detector FDOOTC441 combines ASAtechnology™ with
carbon monoxide (CO) detection for maximum life safety. It responds very
quickly and reliably to fire or the presence of CO. With two optical and two
thermal sensors and one additional electrochemical CO sensor, FDOOTC441
analyzes fire criteria: smoke, heat, and CO. The addi-tional CO sensor ensures
earliest detection of CO-generating fires and detects CO independently from
fire. FDOOTC441 complies with the requirements of the fire safety and carbon
monoxide codes and standards UL 2075 and NFPA 720.
Meeting changing needs
S-LINE fire detectors offer more than 20 application-specific detection
profiles that let you adjust the detectors to the expected environmental
condition. Should the conditions change, you simply modify the detector by
adjusting the detection profile. This provides for reliable and early fire
detection even under changing environmental conditions.
Highlights
- Unique detection reliability and No False Alarm Guarantee provided by ASAtechnologyTM
- Fast, reliable detection of smoke, heat, and carbon monoxide
- Earliest detection of CO- generating fumes, also independently from fire, with the CO detector
- Enhanced life safety provided by selectable fire detection profiles
- Adjustable detection profiles guarantee quick, cost-efficient adaptation to environmental conditions
C-LINE – for standard applications
Reliable in operation
Backed by many years of field experience and proven under numerous operating
conditions, the Desigo C-LINE fire detectors provide comprehensive safety.
This makes C-LINE detectors a great choice in standard environmental
conditions where only occasional deceptive pheno-mena occur, in typical
commercial applications such as:
- Retail stores
- Restaurants
- Offices
Modern, cost-effective technology for investment protection
The addressable technology in the line network FDnet (Field Device network)
permits fast, fault-tolerant communication between fire detectors and the
control panel. All existing wiring can continue to be used. The C-LINE
detectors’ integrated algorithms can easily be adjusted if the room or
building usage changes in the future. This makes C-LINE detectors a cost-
efficient solution and long-term investment.
All-around safety
The installation of the detectors on the FDnet circuit increases safety. In
the event of malfunction, alarms are simply redirected the other way to the
control panel.
Highlights
- State-of-the-art detection algorithms
- Continued use of existing wiring
- Reliable and efficient fire detection
- Protection of your investment thanks to the system’s flexibility and the ability to respond to changing needs
- Cost-effective range of detectors for standard applications
Detectors at a glance
Siemens Industry, Inc.
Building Technologies Division
8 Fernwood Road
Florham Park, NJ 07932
Tel 973-593-2600
Fax 973-593-6670
The information in this document contains general descriptions of technical
options available, which do not always have to be present in individual cases.
The required features should therefore be specified in each individual case at
the time of closing the contract.
All rights reserved. Printed in USA 153-FIS-108
©2015 Siemens Industry, Inc.
www.usa.siemens.com/desigo-fire-safety
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>