Specification

  • One addressable Signaling Line Circuit (SLC) which can be configured as one Class A Style 6 or 7 or two Class B style 4
  • 50 addressable point capacity system
  • Powerful, easy-to-use programming capabilities
  • Fully Field Programmable Via Windows Laptop Computer or by the FACP directly
  • 160×64 dots LCD display
  • Extremely User-friendly system interface
  • Universal AC power input – 120/240VAC, 50/60Hz
  • 6.5 amps of system power
  • Numerous Relays – alarm, trouble, supervisory, programmable…
  • Polarity insensitive detection circuits(Patented)
  • Support one Class A or two Class B SLC
  • Supports FirePrint application specific detection
  • Detector Sensitivity Readout/Printout per NFPA 72
  • 32 Character Custom messages
  • Multiple Command Stations
  • 1000 Event History Logging with On Line & Off Line Reports
  • Multiple Levels of Password Protection
  • Alarm verification by Device or Zone
  • Silence inhibit timer
  • Auto silence timer supported
  • Logic Controlled Output Functions
  • City Tie/Leased Line
  • Built-in DACT (digital alarm communicator transmitter)
  • Support two Notification Appliance Circuits (NACs) rated at 2.5 amps with up to 2.5 amps (24VDC) per NAC
  • Two NAC can be configured as style Y(class B) or style Z (class A)
  • Built-in strobe synchronization protocol
  • Supports Pre-signal and PAS
  • Supports Single Person Quick Test
  • USB interface for local upload/download

Introduction

The FC901 is a compact but powerful standalone fire alarm control panel. It features advanced addressable fire detection, keypad and offline programming, notification circuits, a 160 by 64 dots LCD display and event history retention capability. Its typical configuration includes a power supply, a signaling addressable device circuit, two notification appliance circuits (NAC), Digital Alarm Communication Transmitter (DACT), four system status relays and a USB programming port.All the components of the FC2005 control panel are mounted in an 18.1″ x 16.5″ enclosure.

FC901 main board

The FC901 has only one electronic main board which integrates most functional parts together (the CPU board is mounted to main board before delivery), including DACT, System Display, signaling line circuit, NAC, serial interface circuits, system status relays, programming port and battery charging circuit. The main board is mounted on the supporting frame, and it provides the connections for external field wiring. An optional city tie module can be mounted on the backside of the main board. The power supply is located under the main board and supporting frame.

Power Supply (FP2011-U1)

A 26V (nominal) power supply provides all operating power to the control panel for both standby and alarm conditions. Sufficient battery charging capability is available to charge 12-18 AH sealed lead-acid batteries within code requirements for up to 24 hours of normal standby operation plus 5 minutes of alarm operation. The battery will be automatically disconnected at low battery voltage to prevent deep discharge and battery damage.

Enclosure

All the components of the FC901 control panel are mounted in an 18.1″ x 16.5″ enclosure. FC901 supports surface mounting and semi-flush mounting. Semi-flush mounting kits are available for the enclosure. The enclosures must be fastened securely to a clean, dry, shock-free, and vibration-free surface in a protected environment.

City Tie Module
The city tie module provides local energy and polarity reversal connections. The polarity reversal connections provide a trouble circuit and an alarm circuit with optional trouble output. The city tie board mounts onto the main board.

Order Information

Type Description Part No.
FCM901-U3 FCM901-U3 Cerberus main board S54433-B101-A1
FH901-U3 FH901-U3 Cerberus housing (black) S54433-B103-A3
FH901-R3 FH901-R3 Cerberus housing (red) S54433-B103-A4
FX901-U3 FX901-U3 Cerberus configuration kit S54433-S105-A1
FXA901-A1 FXA901-A1 Configuration cable S54433-K108-A1
FHA902-U1 FHA902-U1 Housing trim kit (black) S54433-B106-A1
FHA902-R1 FHA902-R1 Housing trim kit (red) S54433-B106-A2
FHA901-U1 FHA901-U1 Battery bracket S54433-B107-A1

Beijing Siemens Cerberus Electronics Limited
No.1,Fengzhidonglu, Xibeiwang, HaiDian District,
Beijing, 100094, China
Tel: +10 6476 8806
Fax: +10 6476 8899

firealarmresources.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals